1.Clinical Efficacy of Real-Time Artificial Intelligence-Assisted Colonoscopy in Colorectal Polyp Detection: A Prospective Multicenter Randomized Controlled Trial
Han Jo JEON ; Bora KEUM ; Eui Sun JEONG ; Seong-Eun KIM ; Chang Mo MOON ; Bomee LEE ; Sanghyun KIM ; Hyuk Soon CHOI ; Jae Min LEE ; Eun Sun KIM ; Yoon Tae JEEN
Gut and Liver 2026;20(1):97-106
Background/Aims:
Early detection and removal of colon polyps are critical for preventing colorectal cancer. Computer-aided detection (CADe) systems have been introduced to increase the polyp detection rate (PDR) during colonoscopy, potentially enhancing its effectiveness. This study aimed to evaluate the efficacy of a CADe system in colorectal neoplasm detection.
Methods:
This prospective, randomized controlled trial was conducted at two tertiary centers (May 2023 to April 2025). Patients were randomly assigned to CADe or conventional colonoscopy and underwent screening, surveillance, or diagnostic colonoscopy. The primary endpoint was the adenoma detection rate (ADR), while the secondary endpoints were the PDR, relative risk (RR) of polyp detection, adenomas per colonoscopy (APC), and factors influencing adenoma detection.
Results:
Of 1,004 enrolled patients, 998 were randomly allocated into CADe and conventional colonoscopy groups (497 CADe system and 501 conventional colonoscopy). The CADe group had greater polyp counts (2.2 per colonoscopy vs 1.4 per colonoscopy; p<0.001) and APC values (1.2 vs 0.8; p<0.001). The CADe group showed significantly higher PDRs (72.2% vs 54.5%;p<0.001; RR, 2.173; 95% confidence interval [CI], 1.669 to 2.828) and ADRs (52.3% vs 36.1%;p<0.001; RR, 1.940; 95% CI, 1.505 to 2.499). CADe also significantly increased the detection rate of hyperplastic polyps (p=0.007; RR, 1.474; 95% CI, 1.113 to 1.952) and increased the detection rates across all sizes and locations. In multivariable analysis, CADe use was the strongest independent predictor of adenoma detection (odds ratio, 1.914; 95% CI, 1.467 to 2.496), outweighing male sex, older age, diagnostic indication, and withdrawal time.
Conclusions
Real-time CADe-assisted colonoscopy significantly increased PDR and ADR and proved to be a strong independent predictor of adenoma detection (cris.nih.go.kr, KCT0009664).
2.Asparaginase-Associated Pancreatitis and Pancreatic Pseudocyst Managed with Endoscopic Cystogastrostomy in Adult Acute Lymphoblastic Leukemia
Gyewon PARK ; Eun Sun KIM ; Hyuk Soon CHOI ; Bora KEUM ; Yoon Tae JEEN ; Hoon Jai CHUN ; Hong Sik LEE ; Jae Min LEE
Korean Journal of Pancreas and Biliary Tract 2025;30(1):31-35
Anticancer treatment for acute lymphocytic leukemia is based on drugs such as methotrexate, 6-mercaptopurine, vincristine, and asparaginase. Asparaginase-related pancreatitis is known to have an incidence of up to 18%, and is a major cause of discontinuation of anticancer treatment for leukemia due to acute onset and chronic complications. There were various cases of treatment of peripancreatic fluid retention caused by anticancer drugs in leukemia patients. Use of lumen-apposing metal stents (LAMS) for walled-off necrosis (WON) drainage has recently increased. The electrocautery-enhanced delivery system allowed simpler and faster stent placement, streamlining the overall procedure and potentially reducing procedure time. Therefore, favorable outcomes have been reported with the use of LAMS for endoscopic drainage of various conditions. In this paper, we discuss a case in which hot-system LAMS was performed to treat L-asparaginase-induced acute pancreatitis and pancreatic pseudocyst in an adult patient with acute lymphoblastic leukemia.
3.Asparaginase-Associated Pancreatitis and Pancreatic Pseudocyst Managed with Endoscopic Cystogastrostomy in Adult Acute Lymphoblastic Leukemia
Gyewon PARK ; Eun Sun KIM ; Hyuk Soon CHOI ; Bora KEUM ; Yoon Tae JEEN ; Hoon Jai CHUN ; Hong Sik LEE ; Jae Min LEE
Korean Journal of Pancreas and Biliary Tract 2025;30(1):31-35
Anticancer treatment for acute lymphocytic leukemia is based on drugs such as methotrexate, 6-mercaptopurine, vincristine, and asparaginase. Asparaginase-related pancreatitis is known to have an incidence of up to 18%, and is a major cause of discontinuation of anticancer treatment for leukemia due to acute onset and chronic complications. There were various cases of treatment of peripancreatic fluid retention caused by anticancer drugs in leukemia patients. Use of lumen-apposing metal stents (LAMS) for walled-off necrosis (WON) drainage has recently increased. The electrocautery-enhanced delivery system allowed simpler and faster stent placement, streamlining the overall procedure and potentially reducing procedure time. Therefore, favorable outcomes have been reported with the use of LAMS for endoscopic drainage of various conditions. In this paper, we discuss a case in which hot-system LAMS was performed to treat L-asparaginase-induced acute pancreatitis and pancreatic pseudocyst in an adult patient with acute lymphoblastic leukemia.
4.Asparaginase-Associated Pancreatitis and Pancreatic Pseudocyst Managed with Endoscopic Cystogastrostomy in Adult Acute Lymphoblastic Leukemia
Gyewon PARK ; Eun Sun KIM ; Hyuk Soon CHOI ; Bora KEUM ; Yoon Tae JEEN ; Hoon Jai CHUN ; Hong Sik LEE ; Jae Min LEE
Korean Journal of Pancreas and Biliary Tract 2025;30(1):31-35
Anticancer treatment for acute lymphocytic leukemia is based on drugs such as methotrexate, 6-mercaptopurine, vincristine, and asparaginase. Asparaginase-related pancreatitis is known to have an incidence of up to 18%, and is a major cause of discontinuation of anticancer treatment for leukemia due to acute onset and chronic complications. There were various cases of treatment of peripancreatic fluid retention caused by anticancer drugs in leukemia patients. Use of lumen-apposing metal stents (LAMS) for walled-off necrosis (WON) drainage has recently increased. The electrocautery-enhanced delivery system allowed simpler and faster stent placement, streamlining the overall procedure and potentially reducing procedure time. Therefore, favorable outcomes have been reported with the use of LAMS for endoscopic drainage of various conditions. In this paper, we discuss a case in which hot-system LAMS was performed to treat L-asparaginase-induced acute pancreatitis and pancreatic pseudocyst in an adult patient with acute lymphoblastic leukemia.
5.Asparaginase-Associated Pancreatitis and Pancreatic Pseudocyst Managed with Endoscopic Cystogastrostomy in Adult Acute Lymphoblastic Leukemia
Gyewon PARK ; Eun Sun KIM ; Hyuk Soon CHOI ; Bora KEUM ; Yoon Tae JEEN ; Hoon Jai CHUN ; Hong Sik LEE ; Jae Min LEE
Korean Journal of Pancreas and Biliary Tract 2025;30(1):31-35
Anticancer treatment for acute lymphocytic leukemia is based on drugs such as methotrexate, 6-mercaptopurine, vincristine, and asparaginase. Asparaginase-related pancreatitis is known to have an incidence of up to 18%, and is a major cause of discontinuation of anticancer treatment for leukemia due to acute onset and chronic complications. There were various cases of treatment of peripancreatic fluid retention caused by anticancer drugs in leukemia patients. Use of lumen-apposing metal stents (LAMS) for walled-off necrosis (WON) drainage has recently increased. The electrocautery-enhanced delivery system allowed simpler and faster stent placement, streamlining the overall procedure and potentially reducing procedure time. Therefore, favorable outcomes have been reported with the use of LAMS for endoscopic drainage of various conditions. In this paper, we discuss a case in which hot-system LAMS was performed to treat L-asparaginase-induced acute pancreatitis and pancreatic pseudocyst in an adult patient with acute lymphoblastic leukemia.
6.Asparaginase-Associated Pancreatitis and Pancreatic Pseudocyst Managed with Endoscopic Cystogastrostomy in Adult Acute Lymphoblastic Leukemia
Gyewon PARK ; Eun Sun KIM ; Hyuk Soon CHOI ; Bora KEUM ; Yoon Tae JEEN ; Hoon Jai CHUN ; Hong Sik LEE ; Jae Min LEE
Korean Journal of Pancreas and Biliary Tract 2025;30(1):31-35
Anticancer treatment for acute lymphocytic leukemia is based on drugs such as methotrexate, 6-mercaptopurine, vincristine, and asparaginase. Asparaginase-related pancreatitis is known to have an incidence of up to 18%, and is a major cause of discontinuation of anticancer treatment for leukemia due to acute onset and chronic complications. There were various cases of treatment of peripancreatic fluid retention caused by anticancer drugs in leukemia patients. Use of lumen-apposing metal stents (LAMS) for walled-off necrosis (WON) drainage has recently increased. The electrocautery-enhanced delivery system allowed simpler and faster stent placement, streamlining the overall procedure and potentially reducing procedure time. Therefore, favorable outcomes have been reported with the use of LAMS for endoscopic drainage of various conditions. In this paper, we discuss a case in which hot-system LAMS was performed to treat L-asparaginase-induced acute pancreatitis and pancreatic pseudocyst in an adult patient with acute lymphoblastic leukemia.
7.Clinical guidelines for the diagnosis, evaluation, and management of hypertension for Korean children and adolescents: the Korean Working Group of Pediatric Hypertension
Se Jin PARK ; Hyo Soon AN ; Sung Hye KIM ; Seong Heon KIM ; Hee Yeon CHO ; Jae Hyun KIM ; Anna CHO ; Ji Hee KWAK ; Jae IL SHIN ; Keum Hwa LEE ; Jin-Hee OH ; Jung Won LEE ; Hae Soon KIM ; Hye-Jung SHIN ; Mi Young HAN ; Myung Chul HYUN ; Tae Sun HA ; Young Hwan SONG ;
Kidney Research and Clinical Practice 2025;44(1):20-48
Pediatric hypertension (HTN) is a significant, growing health concern worldwide and also in Korea. Diagnosis, evaluation, and treatment of HTN in Korean children and adolescents are uncertain due to limitations in using the current international guidelines, since the recommendations by the American Academy of Pediatrics (AAP) and European Society of Hypertension (ESH) guidelines differ. Furthermore, these are guidelines for Western youth, who are racially and ethnically different from Koreans. In addition, reference blood pressure values for all pediatric age groups, which are essential for the diagnosis of HTN according to these two guidelines, are absent in Korea. Therefore, HTN guidelines for Korean children and adolescents should be established. The Korean Working Group of Pediatric Hypertension established clinical guidelines for the diagnosis, evaluation, and management of HTN in Korean children and adolescents. These guidelines were based on reported clinical evidence, expert recommendations, and AAP and ESH guidelines. The characteristics of Korean youth and the Korean medical and insurance system were considered during the establishment of the guidelines. By providing recommendations suitable for Korean youth, these guidelines will help in the prevention and management of childhood HTN, thus relieving the burden of cardiovascular disease in adulthood in Korea.
10.A Novel Retractable Robotic Device for Colorectal Endoscopic Submucosal Dissection
Sang Hyun KIM ; Chanwoo KIM ; Bora KEUM ; Junghyun IM ; Seonghyeon WON ; Byung Gon KIM ; Kyungnam KIM ; Taebin KWON ; Daehie HONG ; Han Jo JEON ; Hyuk Soon CHOI ; Eun Sun KIM ; Yoon Tae JEEN ; Hoon Jai CHUN ; Joo Ha HWANG
Gut and Liver 2024;18(4):377-385
Background/Aims:
Appropriate tissue tension and clear visibility of the dissection area using traction are essential for effective and safe endoscopic submucosal dissection (ESD). In this study, we developed a retractable robot-assisted traction device and evaluated its performance in colorectal ESD.
Methods:
An experienced endoscopist performed ESD 18 times on an ex vivo porcine colon using the robot and 18 times using the conventional method. The outcome measures were procedure time, dissection speed, procedure-related adverse events, and blind dissection rate.
Results:
Thirty-six colonic lesions were resected from ex vivo porcine colon samples. The total procedure time was significantly shorter in robot-assisted ESD (RESD) than in conventional ESD (CESD) (20.1±4.1 minutes vs 34.3±8.3 minutes, p<0.05). The submucosal dissection speed was significantly faster in the RESD group than in the CESD group (36.8±9.2 mm 2 /min vs 18.1±4.7 mm 2 /min, p<0.05). The blind dissection rate was also significantly lower in the RESD group (12.8%±3.4% vs 35.1%±3.9%, p<0.05). In an in vivo porcine feasibility study, the robotic device was attached to a colonoscope and successfully inserted into the proximal colon without damaging the colonic wall, and ESD was successfully performed.
Conclusions
The dissection speed and safety profile improved significantly with the retractable RESD. Thus, our robotic device has the potential to provide simple, effective, and safe multidirectional traction during colonic ESD.

Result Analysis
Print
Save
E-mail