1.Single mini-incision combined with honeycomb titanium plate in treatment of acute acromioclavicular joint disloca-tion
Yu-Chen WANG ; Wei-Zhong YU ; Yun-Feng LI ; Wen-Ke ZHU ; Chuan JIA ; Jun-Qi WU ; Hua GAO ; Lin JI
China Journal of Orthopaedics and Traumatology 2024;37(6):576-582
Objective To explore clinical effect of single small incision with honeycomb titanium plate in treating acute acromioclavicular dislocation.Methods The clinical data of 40 patients with acute acromioclavicular dislocation admitted from December 2019 to December 2021 were retrospectively analyzed and divided into two groups according to different surgical methods.Among them,20 patients were fixed with single small incision with honeycomb titanium plate(titanium plate group),including 11 males and 9 females,aged from 23 to 65 years old with an average of(47.40±12.58)years old;12 patients on the left side,8 patients on the right side;11 patients with type Ⅲ,3 patients with type Ⅳ,and 6 patients with type Ⅴ according to Rockwood classification.Twenty patients were fixed with clavicular hook plate(clavicular hook group),including 8 males and 12 females,aged from 24 to 65 years old with an average of(48.40±12.08)years old;12 patients on the left side,8 patients on the right side;10 patients with type Ⅲ,2 patients with type Ⅳ,and 8 patients with type V according to Rockwood classifica-tion.Operative time,incision length,intraoperative blood loss,hospital stay,visual analogue scale(VAS)and Constant-Murley score of shoulder joint function were compared between two groups.Anteroposterior radiographs of the affected shoulder joint were recorded before,immediately and 6 months after surgery,and the coracoclavicular distance was measured and compared.Results Both groups of patients were successfully completed operation without serious complications.All patients were fol-lowed up for 6 to 15 months with an average of(11.9±4.8)months.There were no incisional infection,internal plant fracture or failure,bone tunnel fracture and other complications occurred.The incision length of titanium plate group(35.90±3.14)mm was significantly shorter than that of clavicular hook group(49.30±3.79)mm(P<0.05).There were no significant difference in operative time,intraoperative blood loss and hospital stay between two groups(P>0.05).At 1 and 3 months after operation,VAS of titanium plate group was lower than that of clavicular hook group(P<0.05).Connstant-Murley scores in titanium plate group at 1,3 and 6 months after operation were(86.80±1.36),(91.60±2.32)and(94.90±2.22),respectively;and in clavicular hook group were(78.45±5.47),(85.55±2.01)and(90.25±1.92),which were higher than that of clavicular hook group(P<0.05).There was no significant difference in coracoclavicular distance between two groups immediately and 6 months after op-eration(P>0.05).Conclusion For the treatment of acute acromioclavicular joint dislocation,single small incision combined with honeycomb titanium plate have advantages of shorter incision,fast recovery of shoulder joint function without the second operation,and has good satisfaction of patient.
2.A case of emergency transcatheter aortic valve replacement treatment for aortic stenosis complicated with acute heart failure shock in primary hospital
Huan GUO ; Yu-Dong LI ; Nian-Guo DONG ; Xiao-Ke SHANG ; Yu-Cheng ZHONG ; Chang-Dong ZHANG ; Ling-Bo ZHANG
Chinese Journal of Interventional Cardiology 2024;32(5):291-294
Aortic valve stenosis,as a common heart valve disease,progresses rapidly and has a poor clinical prognosis.In the case of combined acute heart failure,the pumping function of the heart is severely impaired,which may lead to a significant decrease in cardiac output,resulting in a state of shock.Transcatheter aortic valve replacement(TAVR)has become a first-line treatment for elderly patients with aortic valve stenosis since its first successful case in 2002.In China,with the advancement of technology and the strengthening of physician training,the capacity of grassroots hospitals in TAVR treatment is increasing.This case reports a patient with severe aortic valve stenosis accompanied by acute heart failure and shock status who received emergency TAVR treatment at a grassroots hospital.Due to limitations in conditions,TAVR was urgently implemented without extracorporeal circulation and extracorporeal membrane oxygenation support.The patient's blood pressure immediately rose to 105/65 mmHg after valve dilation during surgery,and the postoperative symptoms were significantly relieved.Follow up color Doppler ultrasound showed that the stenosis was relieved and the heart function was significantly improved.The success of this surgery provides a reference for emergency TAVR treatment in patients with severe aortic valve stenosis and heart failure in grassroots hospitals.
3.D-shant atrial shunt device implantable in patients with severe pulmonary hypertension and right heart failure:one case report and literature review
Shu-Na XIAO ; Wen-Jie GAO ; Xiao-Ke SHANG ; Chang-Dong ZHANG ; Yu-Cheng ZHONG ; Ying ZHI ; Lin-Li QIU ; Yan-Fei DONG ; Yan HE ; Wei TIAN ; Wen-Wen TANG
Chinese Journal of Interventional Cardiology 2024;32(8):472-477
To evaluate the effectiveness and safety of implantable D-shant atrial shunt device in patients with severe pulmonary arterial hypertension(PAH)and right heart failure.A 53-year-old female patient diagnosed with severe idiopathic PAH and right heart failure,her WHO FC grade was Ⅳ.The right heart catheter and implantation of D-shant atrial shunt device were performed under local anesthesia on November 30,2021.A 6 mm×4 cm peripheral artery balloon was selected to dilate the atrial septum and a D-shant atrial shunt device with a fixed 4 mm diameter orifice was implanted into the heart.The clinical symptoms and hemodynamics of the patient was improved after the intervention.Implantation of atrial shunt device as a palliative therapy to established a right to left shunt is another strategy for treating patients with severe PAH in late period,which has good effectiveness and safety.It could be the last replacement therapy to improve symptoms and prolonged lives to drug resistant and severe PAH patients.
4.Application of 18F-AlF-P16-093 PET combined with multiparametric MRI in the diagnosis of primary prostate cancer lesions: a head-to-head comparative study based on needle biopsy pathology
Miao KE ; Jinhui LIU ; Shaonan ZHONG ; Jing ZHANG ; Mingzhao LI ; Di GU ; Ruiyue ZHAO ; Xinlu WANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2024;44(9):533-538
Objective:To evaluate the diagnostic efficacy of the novel prostate specific membrane antigen (PSMA)-targeted PET imaging agent 18F-AlF-P16-093 in combination with multiparametric MRI (mpMRI) for prostate cancer (PCa), and to explore its application in guiding transperineal puncture biopsy. Methods:A retrospective analysis was conducted on the clinical and pathological data of 36 patients diagnosed as PCa (age: 68-76 years) who underwent 18F-AlF-P16-093 PET/CT and mpMRI examinations at the First Affiliated Hospital of Guangzhou Medical University from August 2023 to March 2024. The entire prostate was divided into 12 regions based on biopsy localization. Imaging evaluations were performed using PET/CT and mpMRI at the lesion level, with biopsy pathology as the gold standard. The correlations between mpMRI scores, PET/CT scores and pathological diagnosis results were evaluated by Phi coefficient analysis. Diagnostic efficacy was assessed by ROC curve analysis. Logistic regression was used to determine the impact of bleeding on image interpretation. Results:18F-AlF-P16-093 PET/CT showed a moderate positive correlation with pathological diagnosis result ( Phi=0.415, P<0.001), which was superior to mpMRI ( Phi=0.338, P<0.001). The diagnostic efficacy of PET single-modality model was superior to mpMRI in all indicators. The combination of 18F-AlF-P16-093 PET/CT with mpMRI significantly improved diagnostic specificity and positive predictive value, with the diagnostic specificity of the PET+ T 2 weighted imaging (WI)+ diffusion WI (DWI) and PET+ T 2WI+ DWI+ apparent diffusion coefficient (ADC) combinations exceeding 90%, and the positive predictive value exceeding 80%. Bleeding did not significantly affect the diagnosis of PCa by mpMRI and PET/CT (odds ratio ( OR): 0.463-0.785, all P>0.05). Conclusion:18F-AlF-P16-093 PET/CT is superior to mpMRI in the detection and diagnostic efficacy of PCa lesions, and the combination of 18F-AlF-P16-093 PET with mpMRI can further improve diagnostic specificity and positive predictive value, which is of guiding significance for targeted prostate biopsy.
5.Advances in the study of the human microbiome in renal cell carcinoma
Kangli MA ; Yaorong LI ; Weiguang ZHAO ; Zhixian YAO ; Zhong ZHENG ; Junyao XU ; Junhua ZHENG ; Ke WU
Chinese Journal of Urology 2024;45(9):718-721
Renal cell carcinoma is one of the significant diseases endangering human health. Recent findings have shown that the human microbiome plays an important role in the occurrence and development of renal cell carcinoma, influencing its regression and treatment outcome. At present, microecological research on renal cell carcinoma are still in their initial stages, and their regulatory roles and specific mechanisms still need to be further explored. This article reviews the relationship between the human microbiome and renal cell carcinoma occurrence and development, as well as its role in diagnosis and therapies.
6.Design and implementation of high precision ear pulse wave physiological signal detection device for human centrifuge training
Ke JIANG ; Ming-Hao YANG ; Hai-Xia WANG ; Bao-Hui LI ; Jing-Hui YANG ; Xiao-Xue ZHANG ; Zhong-Zheng GUO ; Xiao-Yang WEI
Chinese Medical Equipment Journal 2024;45(9):35-40
Objective To design and implement a high-precision ear pulse wave physiological signal detection device for human centrifuge training to solve the problems in measurement and calibration of pilot ear pulse wave signal during human centrifuge training.Methods The high-precision ear pulse wave physiological signal detection device was composed of an ear pulse wave acquisition sensor,a signal acquisition and control unit and a host signal processing module.The ear pulse wave acquisition sensor had an ear-clip-like shape and consisted of an outer shell,an inner shell and an elastic steel plate;the signal acquisition and control unit was made up of an power supply module,a constant voltage module for the light source,a signal acquisition module,a master control module and a data transmission module,which had its software developed with an embedded system;the host signal processing module divided the signal processing into 2 phases of signal pre-processing and pulse wave signal monitoring and display.The detection performance of the device was verified by using a physiological electrical signal calibrator to test the ear pulse wave signals detected with the device;the effectiveness and stability of the device were validated by implementing human centrifuge training experiments with different loads.Results The voltage measurement error,amplitude-frequency characteristics and common mode rejection ratio detected by this device were all within the permitted ranges of JJG 760-2003 Verification Regulation for Electro Cardiac Monitor and JJG 954-2019 Verification Regulation of Digital Electroencephalographs;the device was capable of detecting the ear pulse wave signals of pilot during human centrifuge training in real time with little interference from motion and stable signal quality.Conclusion The device can accurately clarify the changes in the amplitude of the pilot's ear pulse wave during human centrifuge training and effectively reflect the changes in the pilot's cerebral blood flow under positive acceleration.[Chinese Medical Equipment Journal,2024,45(9):35-40]
7.Evaluation of Mechanical Properties of a Novel Sacroiliac Lag Screw
Cheng LIANG ; Chuanchuan ZHUO ; Guan WANG ; Wen LI ; Ke DUAN ; Zhong LI ; Xiaobo LU ; Naiqiang ZHUO
Journal of Medical Biomechanics 2024;39(2):265-271
Objective To investigate the biomechanical properties of a novel sacroiliac lag screw with a spiral blade.Methods Percutaneous sacroiliac lag screws were used as the controls.Polyurethane material was used to simulate the trabecular bone,and the pullout resistance performance was tested on an Instron mechanical testing machine.Subsequently,pelvic specimens were utilized to analyze the static stiffness and dynamic stability of the novel sacroiliac lag screw in repairing sacroiliac joint injuries under normal standing conditions,with normal pelvis,single-sided sacroiliac joint injury pelvis,percutaneous sacroiliac lag screw-single screw repair,and percutaneous sacroiliac lag screw-double screw repair as controls.Results The damage to the polyurethane material after screw extraction was smaller in the novel sacroiliac lag screw group.The average effective holding displacement of the novel sacroiliac lag screw was significantly greater than that of the percutaneous sacroiliac lag screw(P<0.05).However,the maximum resistance to the pullout force for the percutaneous sacroiliac lag screw was significantly higher than that for the novel sacroiliac lag screw(P<0.05).The stiffness after repair of sacroiliac joint injuries was significantly higher when using a single sacroiliac lag screw than when using two percutaneous sacroiliac lag screws(P<0.05).The displacement amplitude was the highest in the sacroiliac joint injury group,followed by that in the normal group.The displacement amplitudes in the other groups were similar;however,the differences were statistically significant(P<0.05).The dynamic stability of the sacroiliac lag screw repair group was the best,slightly better than that of the percutaneous sacroiliac lag screw-double screw repair group,and the dynamic stability of the sacroiliac joint injury group was the worst.The novel sacroiliac lag screw effectively repaired the sacroiliac joint injuries.Conclusions The novel sacroiliac lag screw can effectively hold the trabecular bone and has practical clinical utility.
8.Catheter-related bloodstream infection caused by Staphylococcus pas-teuri:one case report
Chong-Zhen WANG ; Shan ZHONG ; Li-Xia XU ; Li-Cheng WANG ; Xiao-Ying FU ; Huan LI ; Yuan-Li LI ; Xiong ZHU ; Hai CHEN ; Dong-Ke CHEN
Chinese Journal of Infection Control 2024;23(8):1040-1043
One patient was admitted to a hospital due to"sepsis,chronic kidney disease,type 2 diabetes,shock,and cerebral infarction".Patient's blood specimen was taken for clinical examination.Aerobic and anaerobic culture results of catheter blood and venous blood were both positive.The pathogen was identified as Staphylococcus pas-teuri by VITEK MS,and the patient was diagnosed as catheter-related bloodstream infection caused by Staphylo-coccus pasteuri.Clinical empirical use of piperacillin for anti-infection treatment was ineffective,and vancomycin was eventually used for treatment based on in vitro antimicrobial susceptibility testing.Patient's condition improved after removing the venous catheter.There are currently no reported cases of Staphylococcus pasteuri in China.Ear-ly identification of pathogen and adjustment of treatment plans based on antimicrobial susceptibility testing results are crucial for effective treatment of this case.
9.Mechanism of Inducing Ferroptosis in Hepatocellular Carcinoma Cells by Shugan Quyu Jiedu Prescription Based on p53/SLC7A11/GPX4 Pathway
Xiaojun CAI ; Renyi YANG ; Zhibin WANG ; Yilin GONG ; Ke WANG ; Lizhu LIN ; Chong ZHONG ; Jing LI
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(8):74-82
ObjectiveTo investigate the effect of Shugan Quyu Jiedu prescription (SGQYJDF) on inducing ferroptosis in hepatocellular carcinoma cells based on the tumor protein 53 (p53)/solute carrier family 7 member 11 (SLC7A11)/glutathione peroxidase 4 (GPX4) pathway. MethodMHCC97H cells were divided into the blank serum group (10% blank serum medium), SGQYJDF-containing serum low concentration group (5% SGQYJDF-containing serum and 5% blank serum medium), SGQYJDF-containing serum medium concentration group (7.5% SGQYJDF-containing serum and 2.5% blank serum medium), SGQYJDF-containing serum high concentration group (10% SGQYJDF-containing serum medium) and sorafenib group (sorafenib concentration of 10 μmol·L-1 in 10% blank serum medium). After 24 hours of intervention, the cell survival rate was detected by cell counting kit-8 (CCK-8) assay. The cell proliferation ability was detected by 5-ethynyl-2′-deoxyuridine (EdU) staining. The intracellular ferrous ion (Fe2+) level was detected by ferrous ion fluorescent probe (FerroOrange) staining. The intracellular malondialdehyde (MDA) and glutathione (GSH) levels were detected by colorimetric assays. The ultrastructure of mitochondria was observed by transmission electron microscopy. The expression levels of ferroptosis-related proteins p53, SLC7A11 and GPX4 were detected by Western blot. ResultIn terms of cell viability, compared with the blank serum group, the SGQYJDF group showed a dose-dependent decrease in the survival rate of MHCC97H cells. Effect of the medium and high concentrations of SGQYJDF on the survival rate of MHCC97H cells were significantly decreased (P<0.01). Additionally, the results of the EdU assay showed that both the medium and high concentrations of SGQYJDF were able to inhibit the proliferation ability of MHCC97H cells (P<0.05, P<0.01). Regarding the biochemical indicators of ferroptosis, compared to the blank serum group, the medium and high concentrations of SGQYJDF were able to dose-dependently increase the intracellular Fe2+ level (P<0.01). The low, medium, and high concentrations of SGQYJDF were able to dose-dependently decrease the level of GSH in MHCC97H cells (P<0.01) and increase the level of MDA in the cells (P<0.05, P<0.01). In terms of pathway-related protein expression, compared to the blank serum group, the medium and high concentrations of SGQYJDF could significantly increase the expression of p53 (P<0.01). The low, medium, and high concentrations of SGQYJDF could significantly decrease the expression of GPX4 (P<0.01). The high concentration of SGQYJDF could decrease the expression of SLC7A11 (P<0.01). In terms of the cell morphology of ferroptosis, compared with the blank serum group, transmission electron microscopy revealed that the low concentration of SGQYJDF caused mitochondrial deformation, while the medium and high concentrations of SGQYJDF resulted in reduced mitochondrial volume, increased double-layer membrane density, and decreased mitochondrial cristae. These features were similar to those of sorafenib-induced ferroptosis. Furthermore, compared with the sorafenib group, the high concentration of SGQYJDF showed no statistically significant differences in cell survival rate, proliferation ability, Fe2+ level, MDA level, and GSH level. ConclusionThe results suggest that SGQYJDF may induce ferroptosis and inhibit proliferation in hepatocellular carcinoma MHCC97H cells by upregulating the expression of p53, suppressing the expressions of GPX4 and SLC7A11, downregulating the level of GSH, and leading to the accumulation of intracellular Fe2+ and MDA.
10.Finite element simulation and experimental test of normal coracoclavicular ligament and flexible reconstruction
Guizhu JI ; Qiu ZHENG ; Wuxiang WANG ; Guan WANG ; Wen LI ; Xiaobo LU ; Ke DUAN ; Zhong LI ; Hongbin YANG ; Cheng LIANG
Chinese Journal of Tissue Engineering Research 2024;28(5):706-711
BACKGROUND:For dislocation of acromioclavicular joint induced by coracoclavicular ligament fracture,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are common repair methods.Further study on the stress distribution and fracture risk of the two repair methods is of great significance. OBJECTIVE:To study the biomechanical properties of the coracoclavicular ligament,and compare the fixation effect,stress distribution and failure mode of single and double EndoButton Plates reconstruction. METHODS:(1)Finite element simulation analysis:Mimics,Wrap and SolidWorks were used to establish normal coracoclavicular ligament,single EndoButton Plate reconstruction and double EndoButton Plates reconstruction.Ansys software was used to analyze the stress and deformation of the scapula and clavicle of each model under vertical load.(2)Sample experiment:Fifteen intact scapular-clavicle specimens were randomly grouped into five groups,with three specimens in each group.In group A,the acromioclavicular ligament was severed and the coracoclavicular ligament remained intact.In group B,acromioclavicular ligaments and trapeoid ligaments were severed,leaving intact conical ligaments.In group C,acromioclavicular ligaments and conical ligaments were cut off,and the intact traprex ligaments were retained.In group D,acromioclavicular and coracoclavicular ligaments were severed,and coracoclavicular ligaments were repaired by single EndoButton Plate reconstruction.In group E,acromioclavicular and coracoclavicular ligaments were severed,and the coracoclavicular ligaments were repaired by double EndoButton Plates reconstruction.The mechanical experiment was carried out by a mechanical testing machine to analyze the biomechanical status,stress distribution and failure patterns of the scapular-clavicle and clavicle. RESULTS AND CONCLUSION:(1)Finite element simulation analysis:The average stress of coracoclavicular ligament attached specimens was the lowest,and the risk of coracoclavicular fracture was less than that of single and double EndoButton Plates reconstruction.The mean stress of the coracoid process was similar in single and double EndoButton Plates reconstruction,and the fracture risk was similar.(2)Sample experiment:In groups A,B,C,D and E,the stiffness of specimens was(26.4±3.5),(19.8±2.8),(21.3±3.2),(57.7±4.1),and(46.2±2.8)N/mm,respectively;the ultimate loads were(545.5±53.7),(360.1±42.1),(250.9±44.4),(643.5±39.1),and(511.9±31.7)N,respectively;global stiffness in groups D and E was higher than that in group A(P=0.000 06,0.000 3);ultimate load in group D was higher than that in group A(P<0.05);the ultimate load was not significantly different between the group E and group A(P>0.05).Ligament fracture was observed in groups A,B and C and coracoid process fracture was found in groups D and E.(3)These results suggest that from the biomechanical analysis,Single EndoButton Plate reconstruction and double EndoButton Plates reconstruction are effective treatment techniques for coracoclavicular ligament fracture in acromioclavicular joint dislocation,but increase the risk of fracture.The double EndoButton Plates reconstruction dispersed the stress of the steel plate and reduced the contact force between the steel plate and bone,but slightly reduced the ultimate bearing capacity.Single and double EndoButton Plates reconstruction should be selected according to the actual clinical situation.

Result Analysis
Print
Save
E-mail