1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Antimicrobial resistance and molecular epidemiological characteristics of Campylobacter in children in Guangdong Province from 2020 to 2022
Jia-Jun LIU ; Dong-Mei HE ; Jing XU ; Qi CHENG ; Ya-Hui SHI ; Fang-Zhu OUYANG ; Bi-Xia KE
Chinese Journal of Zoonoses 2024;40(10):950-958
This study was aimed at understanding the detection rate,drug resistance characteristics,virulence characteris-tics,multi-locus sequence typing,and other molecular epidemic and pathogenic characteristics of Campylobacter jejuni and Campylobacter coli in children in Guangdong Province from 2020 to 2022.Anal swabs or stool samples of suspected infection cases in children from 2020 to 2022 were collected from two hospitals in Guangzhou,Guangdong Province.Campylobacter was isolated and cultured through the filtration method,and identified with a microbial mass spectrometry system;antibiotic resist-ance was analyzed with the agar dilution method;bacterial genome nucleic acids were extracted,and whole-genome sequencing was conducted;and drug resistance genes,virulence genes,multi-locus sequence typing,and phylogenetic analysis based on whole-genome single nucleotide polymorphisms were analyzed from whole-genome sequencing results.First,53 strains of Campy-lobacter were detected through continuous routine monitoring in this study,with a positive detection rate of 2.94%.Among them,Campylobacter jejuni accounted for 81.13%(43/53)and Campylobacter coli accounted for 18.87%(10/53).In addition,16 strains of Campylobacter were screened through multi-pathogen surveillance,including 11 strains of Campylobacter jejuni and 5 strains of Campylobacter coli.Drug resistance ex-periments and whole genome sequencing were conducted on 46 Campylobacter isolates,including 33 isolates of Campylobacter jejuni and 13 isolates of Campylobacter coli.The resistance rate of Campylobacter to erythromycin,a widely used clinical treatment,was21.73%(10/46);that to tetracycline was 80.43%(37/46);those to the quinolone antibiotics nalidixic acid and ciprofloxacin were 76.08%(35/46)and 71.73%(33/46)respectively;and that to chloramphenicol was lowest,at 2.17%(1/46).The drug resistance rate was generally higher for Campylobacter coli than Campylobacter jejuni,and the differences in the indicators of erythromycin,gentamicin,streptomycin,telithromycin,and clindamycin were statistically significant.A total of 30 isolates of multidrug-resistant Campylobacter were detected,including nine multidrug-resistant phenotypes.Whole-ge-nome sequence analysis indicated that 46 Campylobacter isolates carried antibiotic resistance genes for antibiotics such as quino-lones,tetracyclines,β-lactams,and aminoglycosides,and carried 128 virulence factor genes in five categories.All 46 isolates of Campylobacter were identified as 35 ST type through MLST typing,and phylogenetic analysis indicated no obvious dominant ST type.Campylobacter coli had more SNPs than Campylobacter jejuni.In conclusion,the positive detection rate of Campy-lobacter in Guangzhou City,Guangdong Province stabilized from 2020 to 2022,and the detection rate of Campylobacter jejuni was higher than that of Campylobacter coli.Campylobacter isolates were resistant to tetracyclines and quinolone,and showed a wide spectrum of multi-drug resistance,which was relatively severe among Campylobacter coli.Resistance genes and drug-resistant phenotypes were correlated and had predictive significance.The virulence genes of Campylobacter jejuni were more a-bundant than those of Campylobacter coli,possibly because of the higher detection rate and pathogenicity of Campylobacter jejuni.The phylogenetic tree showed clear branches with high genetic diversity and no clearly dominant clonal group.
7.Association of Triglyceride Glucose-Derived Indices with Recurrent Events Following Atherosclerotic Cardiovascular Disease
Sha LI ; Hui-Hui LIU ; Yan ZHANG ; Meng ZHANG ; Hui-Wen ZHANG ; Cheng-Gang ZHU ; Yuan-Lin GUO ; Na-Qiong WU ; Rui-Xia XU ; Qian DONG ; Ke-Fei DOU ; Jie QIAN ; Jian-Jun LI
Journal of Obesity & Metabolic Syndrome 2024;33(2):133-142
Background:
Triglyceride glucose (TyG) and TyG-body mass index (TyG-BMI) are reliable surrogate indices of insulin resistance and used for risk stratification and outcome prediction in patients with atherosclerotic cardiovascular disease (ASCVD). Here, we inserted estimated average glucose (eAG) into the TyG (TyAG) and TyG-BMI (TyAG-BMI) as derived parameters and explored their clinical significance in cardiovascular risk prediction.
Methods:
This was a population-based cohort study of 9,944 Chinese patients with ASCVD. The baseline admission fasting glucose and A1C-derived eAG values were recorded. Cardiovascular events (CVEs) that occurred during an average of 38.5 months of follow-up were recorded. We stratified the patients into four groups by quartiles of the parameters. Baseline data and outcomes were analyzed.
Results:
Distribution of the TyAG and TyAG-BMI indices shifted slightly toward higher values (the right side) compared with TyG and TyG-BMI, respectively. The baseline levels of cardiovascular risk factors and coronary severity increased with quartile of TyG, TyAG, TyG-BMI, and TyAG-BMI (all P<0.001). The multivariate-adjusted hazard ratios for CVEs when the highest and lowest quartiles were compared from low to high were 1.02 (95% confidence interval [CI], 0.77 to 1.36; TyG), 1.29 (95% CI, 0.97 to 1.73; TyAG), 1.59 (95% CI, 1.01 to 2.58; TyG-BMI), and 1.91 (95% CI, 1.16 to 3.15; TyAG-BMI). The latter two showed statistical significance.
Conclusion
This study suggests that TyAG and TyAG-BMI exhibit more information than TyG and TyG-BMI in disease progression among patients with ASCVD. The TyAG-BMI index provided better predictive performance for CVEs than other parameters.
8.Metagenomic next-generation sequencing for the diagnosis of Pneumocystis jirovecii pneumonia after allogeneic hematopoietic stem cell transplantation
Rong FU ; Ren LIN ; Zhiping FAN ; Fen HUANG ; Na XU ; Li XUAN ; Yifei HUANG ; Hui LIU ; Ke ZHAO ; Zhixiang WANG ; Ling JIANG ; Min DAI ; Jing SUN ; Qifa LIU
Chinese Journal of Hematology 2024;45(1):62-67
Objectives:To investigate the value of metagenomic next-generation sequencing (mNGS) in the diagnosis of Pneumocystis jirovecii pneumonia (PJP) in patients undergoing allogeneic hematopoietic stem cell transplantation (allo-HSCT) .Methods:The data of 98 patients with suspected pulmonary infection after allo-HSCT who underwent pathogen detection from bronchoalveolar lavage fluid between June 2016 and August 2023 at Nanfang Hospital were analyzed. The diagnostic performance of mNGS, conventional methods, and real-time quantitative polymerase chain reaction (qPCR) for PJP were compared.Results:A total of 12 patients were diagnosed with PJP, including 11 with a proven diagnosis and 1 with a probable diagnosis. Among the patients with a proven diagnosis, 1 was positive by both conventional methods and qPCR, and 10 were positive by qPCR only. Pneumocystis jirovecii was detected by mNGS in all 12 patients. The diagnostic sensitivity of mNGS for PJP was 100%, which was greater than that of conventional methods (8.3%, P=0.001) and similar to that of qPCR (91.6%, P=1.000) . A total of 75% of the patients developed mixed pulmonary infections, and cytomegalovirus and Epstein-Barr virus were the most common pathogens. Mixed infection was detected in eight patients by mNGS and in five patients by qPCR, but not by conventional methods ( P=0.008) . Conclusions:mNGS had good sensitivity for diagnosing PJP after allo-HSCT and was advantageous for detecting mixed infectious pathogens; therefore, mNGS might be an effective supplement to regular detection methods and qPCR.
9.Design,numerical simulation and experimental study of novel oxygenator
Ming-Hao YUE ; Shi-Yao ZHANG ; Ji-Nian LI ; Hui-Chao LIU ; Zi-Hua SU ; Ya-Wei WANG ; Zeng-Sheng CHEN ; Shi-Hang LIN ; Jin-Yu LI ; Ya-Ke CHENG ; Yong-Fei HU ; Cun-Ding JIA ; Ming-Zhou XU
Chinese Medical Equipment Journal 2024;45(3):23-28
Objective To design a novel oxygenator to solve the existing problems of extracorporeal membrane oxygenation(ECMO)machine in high transmembrane pressure difference,low efficiency of blood oxygen exchange and susceptibility to thrombosis.Methods The main body of the oxygenator vascular access flow field was gifted with a flat cylindrical shape.The topology of the vascular access was modeled in three dimensions,and the whole flow field was cut into a blood inlet section,an inlet buffer,a heat exchange zone,a blood oxygen exchange zone,an outlet buffer and a blood outlet section.The oxygenator was compared with Quadrox oxygenator by means of ANSYS FLUENT-based simulation and prototype experiments.Results Simulation calculations showed the oxygenator designed was comparable to the clinically used ones in general,and gained advantages in transmembrane pressure difference,blood oxygen exchange and flow uniformity.Experimental results indicated that the oxygenator behaved better than Quadrox oxygenator in transmembrane pressure difference and blood oxygen exchange.Conclusion The oxygenator has advantages in transmem-brane pressure difference,temperature change,blood oxygen ex-change and low probability of thrombosis.[Chinese Medical Equipment Journal,2024,45(3):23-28]
10.Modal testing study of three-axis manned centrifuge under elastic boundary conditions
Hai-Xia WANG ; Ke JIANG ; Zhao JIN ; Yi WANG ; Li-Hui ZHANG ; Yan XU ; Cong WANG ; Ming-Hao YANG ; Jing-Hui YANG ; Xiao-Xue ZHANG ; Yuan-Jing ZHENG ; Bao-Hui LI
Chinese Medical Equipment Journal 2024;45(8):38-43
Objective To explore the modal testing method for the three-axis manned centrifuge under elastic boundary conditions with considerations on its complicated structure and high rotational inertia.Methods Modal testing was carried out with a three-axis manned centrifuge under elastic boundary conditions as the subject and a force hammer as the excitation source according to GJB 2706A-2008 Modal tests method for spacecraft and GB/T 11349.3-1992 Experimental determination of mechnical mobility measurements using impact excitation.Four times of hammering were carried out at each excitation position,and the data of the four times of hammering underwent linear average computation.Data acquisition was implemented with a three-axis accelerometer and a 64-channel data collector,and the modal data were analyzed using a frequency response function based on the Test.Lab modal test and analysis software.Results The coherence coefficient of the excitation signal was not lower than 0.8 in the 30 Hz band;the first three orders of the system's intrinsic vibrations were all torsional vibrations,with the frequencies of 9.15,15.66 and 19.22 Hz,respectively;the first order frequency of the system was about 9.15 Hz for both Z18 and Z21 excitation positions,and each of the second and third order frequencies similar situations were observed for also had a roughly equal value for the two excitation positions.Conclusion The force hammer testing method is applicable for the modal testing of the three-axis manned centrifuge,ensuring equipment safety and subject comfort.Referen-ces are provided for the following structural optimization design.[Chinese Medical Equipment Journal,2024,45(8):38-43]