2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Prevalence of chronic diarrhea and its association with obesity in a Chinese community-based population.
Ke HAN ; Xiangyao WANG ; Yan WANG ; Xiaotong NIU ; Jingyuan XIANG ; Nan RU ; Chunxu JIA ; Hongyi SUN ; Zhengting HE ; Yujie FENG ; Enqiang LINGHU
Chinese Medical Journal 2025;138(13):1587-1594
BACKGROUND:
Epidemiological data on chronic diarrhea in the Chinese population are lacking, and the association between obesity and chronic diarrhea in East Asian populations remains inconclusive. This study aimed to investigate the prevalence of chronic diarrhea and its association with obesity in a representative community-dwelling Chinese population.
METHODS:
This cross-sectional study was based on a multistage, randomized cluster sampling involving 3503 residents aged 20-69 years from representative urban and rural communities in Beijing. Chronic diarrhea was assessed using the Bristol Stool Form Scale (BSFS), and obesity was determined based on body mass index (BMI). Logistic regression analysis and restricted cubic splines were used to evaluate the relationship between obesity and chronic diarrhea.
RESULTS:
The standardized prevalence of chronic diarrhea in the study population was 12.88%. The average BMI was 24.67 kg/m 2 . Of all the participants, 35.17% (1232/3503) of participants were classified as overweight and 16.13% (565/3503) as obese. After adjustment for potential confounders, individuals with obesity had an increased risk of chronic diarrhea as compared to normal weight individuals (odds ratio = 1.58, 95% confidence interval: 1.20-2.06). A nonlinear association between BMI and the risk of chronic diarrhea was observed in community residents of males and the overall participant group ( P = 0.026 and 0.017, respectively).
CONCLUSIONS
This study presents initial findings on the prevalence of chronic diarrhea among residents of Chinese communities while offering substantiated evidence regarding the significant association between obesity and chronic diarrhea. These findings offer a novel perspective on gastrointestinal health management.
Adult
;
Aged
;
Female
;
Humans
;
Male
;
Middle Aged
;
Young Adult
;
Body Mass Index
;
China/epidemiology*
;
Chronic Disease/epidemiology*
;
Cross-Sectional Studies
;
Diarrhea/epidemiology*
;
Obesity/complications*
;
Prevalence
;
East Asian People/statistics & numerical data*
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Association of Genetically Predicted Obesity and Stool Frequency: Evidence From an Observational and Mendelian Randomization Study
Ke HAN ; Xiangyao WANG ; Shimin CHEN ; Xiaotong NIU ; Yan WANG ; Jingyuan XIANG ; Nan RU ; Miao LIU ; Ningli CHAI ; Enqiang LINGHU
Journal of Neurogastroenterology and Motility 2025;31(2):267-275
Background/Aims:
Obesity is associated with several gastrointestinal (GI) disorders and has been identified as a potential risk factor for various GI symptoms. Bowel frequency is an important indicator of bowel function. However, the causal link between obesity and gastrointestinal motility remains uncertain. This study aims to determine the causal effect of overall and central obesity on stool frequency.
Methods:
Four obesity-related anthropometric indicators–body mass index, body fat percentage, waist circumference (WC), and waist-tohip ratio (WHR)–were investigated. Individual-level baseline information from the UK Biobank was used to explore observational associations between obesity and stool frequency. Additionally, summary-level data from published genome-wide association studies were subjected to two-sample Mendelian randomization (MR) analyses to examine causal associations.
Results:
For all 4 indicators of obesity, higher levels of obesity were associated with more frequent bowel movements after adjusting for demographic characteristics, lifestyle, and dietary factors. After rigorous screening, 482 body mass index single nucleotide polymorphisms (SNPs), 7 body fat percentage SNPs, 48 WC SNPs, and 287 WHR SNPs were identified as instrument variables for MR analysis. The MR results were generally consistent with observational findings, proving that the associations observed in the overall obesity indicators were causal. For central obesity, the association between WHR and stool frequency remained consistent in both analysis phases, whereas WC showed a multidirectional association.
Conclusions
Obesity-related anthropometric indicators were causally associated with increased stool frequency in the overall and central obesity groups. Weight loss could be a potential approach to improve gastrointestinal regularity in individuals with obesity.
7.Association of Genetically Predicted Obesity and Stool Frequency: Evidence From an Observational and Mendelian Randomization Study
Ke HAN ; Xiangyao WANG ; Shimin CHEN ; Xiaotong NIU ; Yan WANG ; Jingyuan XIANG ; Nan RU ; Miao LIU ; Ningli CHAI ; Enqiang LINGHU
Journal of Neurogastroenterology and Motility 2025;31(2):267-275
Background/Aims:
Obesity is associated with several gastrointestinal (GI) disorders and has been identified as a potential risk factor for various GI symptoms. Bowel frequency is an important indicator of bowel function. However, the causal link between obesity and gastrointestinal motility remains uncertain. This study aims to determine the causal effect of overall and central obesity on stool frequency.
Methods:
Four obesity-related anthropometric indicators–body mass index, body fat percentage, waist circumference (WC), and waist-tohip ratio (WHR)–were investigated. Individual-level baseline information from the UK Biobank was used to explore observational associations between obesity and stool frequency. Additionally, summary-level data from published genome-wide association studies were subjected to two-sample Mendelian randomization (MR) analyses to examine causal associations.
Results:
For all 4 indicators of obesity, higher levels of obesity were associated with more frequent bowel movements after adjusting for demographic characteristics, lifestyle, and dietary factors. After rigorous screening, 482 body mass index single nucleotide polymorphisms (SNPs), 7 body fat percentage SNPs, 48 WC SNPs, and 287 WHR SNPs were identified as instrument variables for MR analysis. The MR results were generally consistent with observational findings, proving that the associations observed in the overall obesity indicators were causal. For central obesity, the association between WHR and stool frequency remained consistent in both analysis phases, whereas WC showed a multidirectional association.
Conclusions
Obesity-related anthropometric indicators were causally associated with increased stool frequency in the overall and central obesity groups. Weight loss could be a potential approach to improve gastrointestinal regularity in individuals with obesity.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Association of Genetically Predicted Obesity and Stool Frequency: Evidence From an Observational and Mendelian Randomization Study
Ke HAN ; Xiangyao WANG ; Shimin CHEN ; Xiaotong NIU ; Yan WANG ; Jingyuan XIANG ; Nan RU ; Miao LIU ; Ningli CHAI ; Enqiang LINGHU
Journal of Neurogastroenterology and Motility 2025;31(2):267-275
Background/Aims:
Obesity is associated with several gastrointestinal (GI) disorders and has been identified as a potential risk factor for various GI symptoms. Bowel frequency is an important indicator of bowel function. However, the causal link between obesity and gastrointestinal motility remains uncertain. This study aims to determine the causal effect of overall and central obesity on stool frequency.
Methods:
Four obesity-related anthropometric indicators–body mass index, body fat percentage, waist circumference (WC), and waist-tohip ratio (WHR)–were investigated. Individual-level baseline information from the UK Biobank was used to explore observational associations between obesity and stool frequency. Additionally, summary-level data from published genome-wide association studies were subjected to two-sample Mendelian randomization (MR) analyses to examine causal associations.
Results:
For all 4 indicators of obesity, higher levels of obesity were associated with more frequent bowel movements after adjusting for demographic characteristics, lifestyle, and dietary factors. After rigorous screening, 482 body mass index single nucleotide polymorphisms (SNPs), 7 body fat percentage SNPs, 48 WC SNPs, and 287 WHR SNPs were identified as instrument variables for MR analysis. The MR results were generally consistent with observational findings, proving that the associations observed in the overall obesity indicators were causal. For central obesity, the association between WHR and stool frequency remained consistent in both analysis phases, whereas WC showed a multidirectional association.
Conclusions
Obesity-related anthropometric indicators were causally associated with increased stool frequency in the overall and central obesity groups. Weight loss could be a potential approach to improve gastrointestinal regularity in individuals with obesity.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail