1.The application strategies of non-uniform sampling in the structure elucidation of small molecule compounds—an instantiation using fuziline
Li-li ZHANG ; Ke ZHANG ; Jie LIU ; Chun-wang MENG ; Rui FENG ; Liang XIONG
Acta Pharmaceutica Sinica 2025;60(1):218-224
Two-dimensional nuclear magnetic resonance (2D NMR) is a widely used technique for structural analysis of small molecular compounds. It can obtain information about the hydrogen-hydrogen correlation, hydrogen-carbon single bond correlation, hydrogen-carbon remote correlation, and hydrogen-hydrogen spatial arrangement of compounds. Thus, 2D NMR has an irreplaceable role in the structure elucidation of small molecular products. However, the sample amount of trace components in phytochemical research is very low, and the traditional sampling method (uniform sampling) has problems of poor spectral quality and too long measure time. Increasing the number of scans results in several hours of the acquisition time for a single two-dimensional spectrum, which in turn causes strain on the NMR machine. The non-uniform sampling (NUS) technique can shorten the acquisition time to a large extent and not affect the quality of 2D NMR data, which greatly improves the efficiency of 2D NMR acquisition. In this paper, fuziline, a small molecular compound in the lateral roots of
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent cloud platform follow-up model improves joint range of motion and reduces follow-up costs after total knee arthroplasty:A retrospective cohort study
Shangwei YU ; Ke ZENG ; Ran XIONG ; Liming LIU ; Lin GUO
Journal of Army Medical University 2025;47(22):2763-2773
Objective To determine whether an intelligerct cloud platform follow-up model demonstrates superiority over conventional methods in enhancing follow-up quality,reducing costs,and improving functional recovery following total knee arthroplasty(TKA).Methods A retrospective cohort study was conducted on 260 patients undergoing TKA at our hospital from October 2022 to September 2023.According to the different postoperative follow-up methods,they were divided int a cloud platform group(n=130)and a traditional group(n=130).The baseline data,pre-and postoperative knee function scores,and follow-up costs were collected and compared between the 2 groups.Results The cloud platform group exhibited significantly higher rate of follow-up satisfaction,reduced resource utilization,shorter per-follow-up duration,fewer accompanying persons per visit,lower total follow-up expenditures,and decreased cumulative follow-up time when compared with the traditional group(P<0.05).At 6 weeks,3,6,and 12 months postoperatively,better range of motion(ROM)was observed in the cloud-based group than the traditional group(P<0.05),but no intergroup differences were seen in other knee function scores.Conclusion Cloud platform follow-up enhances early postoperative ROM(6 weeks to 12 months)and demonstrates marked cost-effectiveness when compared to the conventional mode.It represents a viable alternative for post-TKA rehabilitation surveillance.
5.Observation on the Therapeutic Effect of Internal and External Application of Osteoking in Treating Knee Osteoarthritis of Cold-Damp Blockage Type
Yixiao XIONG ; Qindai LIU ; Linhan BAI ; Sheng HUA ; Zuyu TANG ; Ke LIU ; Liang OU ; Jianjun KUANG
Journal of Guangzhou University of Traditional Chinese Medicine 2025;42(2):298-308
Objective To observe the clinical efficacy of oral use combined with targeted transdermal delivery of Osteoking in treating knee osteoarthritis(KOA)of cold-damp blockage type.Methods A total of 120 patients with KOA of cold-damp blockage type who admitted to Hunan Provincial Hospital of Integrated Traditional Chinese And West Medicine from September 2022 to September 2023 were randomly divided into the control group,oral use group,transdermal delivery group and combination group according to the random number table method,with 30 cases in each group.The control group was treated with Celecoxib Capsule orally,the oral use group was treated with Osteoking orally,the transdermal delivery group was treated with Osteoking by targeted transdermal delivery,and the combination group was treated with oral use combined with targeted transdermal delivery of Osteoking.One course of treatment covered 12 days,and all of the four groups were treated for two continuous courses.Before and after treatment,the scores of traditional Chinese medicine(TCM)syndrome,Visual Analogue Scale(VAS)for pain,Western Ontario and McMaster Universities Osteoarthritis Index(WOMAC)for joint function,36-Item Short Form Health Survey(SF-36)for quality of life(QOL),as well as the levels of serum interleukin 1β(IL-1β),interleukin 6(IL-6),and tumor necrosis factor α(TNF-α)were observed in the patients of each group.After treatment,the clinical efficacy and safety of patients in each group were evaluated.Results(1)After two courses of treatment,the total effective rate of the combination group was 96.67%(29/30),which was higher than those of the control group[73.33%(22/30)],oral use group and transdermal delivery group[both being 70.00%(21/30)],and the difference was statistically significant(P<0.05).However,no statistically significant difference of the total effective rate was presented among the control group,oral use group,and transdermal delivery group(P>0.05).(2)After treatment,the scores of TCM syndrome,VAS for pain and WOMAC for joint function in the four groups were decreased compared with those before treatment(P<0.01).The intergroup comparison showed that the scores of TCM syndrome,VAS for pain and WOMAC in the combination group were lower than those in the other three groups(P<0.05),while no statistically significant difference of the scores of TCM syndrome,VAS for pain and WOMAC were presented among the control group,oral use group,and transdermal delivery group(P>0.05).(3)After treatment,the QOL scores of the eight dimensions of SF-36 such as physical functioning(PF),bodily pain(BP),general health(GH),vitality(VT),role-physical(RP),social functioning(SF),role-emotional(RE),and mental health(MH)in the four groups were significantly increased compared with those before treatment(P<0.01).The intergroup comparison showed that the scores of each dimension of SF-36 in the combination group were significantly higher than those in the other three groups(P<0.05),while no statistically significant difference of the dimension score of SF-36 was presented among the control group,oral use group,and transdermal delivery group(P>0.05).(4)After treatment,the levels of serum inflammatory factors of IL-1β,IL-6,and TNF-α in the four groups were decreased compared with those before treatment(P<0.01).The intergroup comparison showed that the decrease of serum levels of inflammatory factors in the combination group were significantly superior to those in the other three groups(P<0.05),and the decrease in the control group and oral use group were all superior to those in the transdermal delivery group(P<0.05),while the difference between the control group and oral use group was not statistically significant(P>0.05).(5)During the trial,no serious adverse reactions were found in the patients of four groups,which is of high safety.Conclusion Oral use combined with targeted transdermal delivery of Osteoking is effective on improving the joint pain,joint function and QOL of patients with KOA of cold-damp blockage type,and can speed up the rehabilitation of patients.Its therapeutic mechanism may be related to the decrease of the expression level of inflammatory factors.
6.Study on Reentry Strategy and Results of Blood Donors with Single Reagent Reactivity in Wuhan Area.
Ting-Ting XU ; Qin YU ; Song-Qing KE ; Yan CAI ; Song-Li XIE ; Jing XIONG ; Lei ZHAO
Journal of Experimental Hematology 2025;33(2):530-537
OBJECTIVE:
To study the results, re-donation situation and characteristics of single-reagent reactive blood donors who were put into the reentry strategy in Wuhan area, explore the rationality and effectiveness of the current reentry strategy, and provide data support for the improvement of the reentry process of blood donors.
METHODS:
From January 2020 to December 2023, blood donors who conform the reentry criteria and voluntarily applied for returning to Wuhan Blood Center were tested and the results were analyzed. According to the reentry strategy, serological testing and nucleic acid testing were carried out in parallel, serological testing was performed by ELISA with reagents from two different manufacturers, and the primary reactive samples were tested by double-well retest, and HBV/HCV/HIV nucleic acid detection was performed by RT-PCR with an individual donor test mode. Supplementary HBcAb testing was applied for HBV single reagent reactivity by chemiluminescence method. Supplementary TP-WB testing was applied for returning blood donors with repeated TP single reagent reactivity. If returning blood donors with HIV single reagent reactivity were repeated single reagent reactivity, the samples were sent to local CDC for confirmatory test.
RESULTS:
7 098 blood donors were qualified for reentry, 716 donors voluntarily applied for reentry, 436 donors successfully reentry, 251 donors entered the next round, 29 donors could not reentry. The reentry rates for the past four years were 66.67%(42/63), 54.73%(81/148), 60.71%(136/224) and 62.99%(177/281), respectively. Up to December 31, 2023, 275 donors donated blood again, and the donation rates for past four years were 76.19%(32/42), 72.84%(59/81), 61.76%(84/136) and 56.50%(100/177), respectively. After donating blood, 31 donors were disqualified again by blood screening and subjected to permanent deferral. The results of returning to the team had statistical differences in reentry items, educational level, age, and marriage(P < 0.05).
CONCLUSION
The current reentry strategy adopted by the blood donation and supply institution can effectively retain part of blood donors, reduce the negative emotions of blood donors and increase blood resources.
Humans
;
Blood Donors
;
China
;
Hepatitis B
;
Enzyme-Linked Immunosorbent Assay
;
Hepatitis C
;
Male
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.From pioneering to innovation: A comprehensive review of acupuncture anesthesia in cardiothoracic surgeries.
Xin-di WU ; Xu-Qiang WEI ; Tong-Yu CHEN ; Wen-Xiong ZHOU ; Ke WANG ; Jia ZHOU
Journal of Integrative Medicine 2025;23(6):623-629
The evolution of acupuncture anesthesia (AA) has spanned six decades. Cardiothoracic surgery serves as a representative case study to illustrate this evolution. Reflecting on its historical development, the use of AA in cardiothoracic surgery has advanced from basic AA procedures in the 1960s to combined acupuncture and drug anesthesia techniques in the early 1980s. Since 2005, the innovative use of non-intubation AA combined anesthesia has been implemented extensively in cardiothoracic surgery. As the medical industry continues to evolve, the techniques applied in AA have expanded to encompass the entire perioperative period in cardiothoracic surgery, leading to the introduction of the concept of modern AA. The use of AA in cardiothoracic surgery exemplifies the ongoing advances and integration of traditional Chinese and Western medicine. Moving forward, it is imperative to enhance the theoretical framework of AA through the execution of rigorous multicenter clinical trials, to further strengthen the body of evidence supporting evidence-based medicine, and to finally explore the underlying mechanisms of AA. Please cite this article as: Wu XD, Wei XQ, Chen TY, Zhou WX, Wang K, Zhou J. From pioneering to innovation: A comprehensive review of acupuncture anesthesia in cardiothoracic surgeries. J Integr Med. 2025; 23(6):623-629.
Humans
;
Acupuncture Analgesia/methods*
;
Acupuncture Therapy/methods*
;
Cardiac Surgical Procedures
;
Anesthesia/methods*
;
Thoracic Surgical Procedures

Result Analysis
Print
Save
E-mail