1.The Diversity of Filamentous Morphologies and Magnetic Sensitivity Modulated by Diverse MagR Expression in Bacteria
Ya-Fei CHANG ; Jing ZHANG ; Peng ZHANG ; Xiu-Juan ZHOU ; Meng-Ke WEI ; Tian-Tian CAI ; Pei-Qi HE ; Jun-Feng WANG ; Can XIE
Progress in Biochemistry and Biophysics 2026;53(5):1439-1456
Objective Magnetoreception, the remarkable ability of diverse animals to sense and utilize the geomagnetic field for orientation and navigation, remains a molecularly unresolved mystery in sensory biology. The putative magnetoreceptor (MagR, previously known as IscA1) is a highly conserved iron-sulfur protein implicated in both magnetoreception and iron metabolism; however, the functional diversity among its cross-species homologs remains poorly understood. Cellular morphology is a key genetically determined trait that can be altered through genetic or environmental modifications—a process known as cell morphology engineering. Constructing engineered cells with specific morphological features and magnetic sensitivity to achieve remote, non-invasive magnetic modulation represents a crucial goal in this field with significant application potential. Therefore, this study aims to systematically investigate the effects of MagR heterologous expression on bacterial morphology and magnetic sensing capabilities, screen for MagR-based magnetically sensitive morphology engineering pathways, and reveal the underlying molecular mechanisms. Methods We systematically screened 28 MagR homologous genes from diverse prokaryotic and animal taxa to evaluate their expression and corresponding phenotypic effects in Escherichia coli (E. coli). To compare the differential magnetic responses among bacteria expressing various recombinant MagR proteins, we utilized high-throughput automated bright-field microscopic imaging and scanning electron microscopy (SEM). Furthermore, comprehensive biochemical and biophysical characterizations of iron and iron-sulfur cluster binding were performed using Ferrozine colorimetric assays, electron paramagnetic resonance (EPR) spectroscopy, ultraviolet-visible (UV-Vis) absorption, and circular dichroism (CD) spectroscopy. Additionally, 100 mT static magnetic field (SMF) exposure experiments were conducted to assess magnetically tunable phenotypes, while the intrinsic magnetic properties of purified MagR proteins were directly measured using a superconducting quantum interference device (SQUID) magnetometer. Results Our results demonstrated that the heterologous expression of MagR homologs induced varying degrees of bacterial filamentation. From this comprehensive screen, two distinct morphological patterns were identified: hydra (Hydra vulgaris) MagR (hyMagR) promoted uniform cell elongation and filamentation, exhibiting robust magnetic sensitivity manifested as significantly enhanced filamentation under the 100 mT SMF. In contrast, pigeon (Columba livia) MagR (clMagR) induced only low-frequency, extreme filamentation (sporadically exceeding 80 μm) with a relatively weaker magnetic morphological response. Mechanistically, our data unambiguously proved that these phenotypic differences are primarily driven by distinct iron redox preferences rather than total cellular iron accumulation. Specifically, hyMagR preferentially binds ferrous iron (Fe2+), whereas clMagR favors ferric iron (Fe3+) and forms more stable iron-sulfur clusters. Intriguingly, although SQUID magnetometry showed that purified clMagR exhibited approximately five-fold higher mass magnetic susceptibility than hyMagR, its cellular magnetic response was weaker. We hypothesize that the Fe2+-preferred intracellular environment associated with hyMagR overexpression primes the cell for enhanced generation of reactive oxygen species (ROS) via the Fenton reaction. Exposure to an SMF synergizes with this primed redox state, triggering the bacterial SOS response and upregulating cell division inhibitors to efficiently induce uniform filamentation. Conclusion Our findings identify the Fe2+/Fe3+ redox state as a critical determinant of MagR-mediated morphological remodeling and magnetic responsiveness. This discovery suggests a potential strategy for engineering magnetically responsive cellular systems for synthetic biology applications, and provides a plausible framework, which potentially combines intrinsic protein magnetism with redox-state modulation, for further investigating the evolutionary mechanisms of MagR-mediated magnetoreception.
2.The Diversity of Filamentous Morphologies and Magnetic Sensitivity Modulated by Diverse MagR Expression in Bacteria
Ya-Fei CHANG ; Jing ZHANG ; Peng ZHANG ; Xiu-Juan ZHOU ; Meng-Ke WEI ; Tian-Tian CAI ; Pei-Qi HE ; Jun-Feng WANG ; Can XIE
Progress in Biochemistry and Biophysics 2026;53(5):1439-1456
Objective Magnetoreception, the remarkable ability of diverse animals to sense and utilize the geomagnetic field for orientation and navigation, remains a molecularly unresolved mystery in sensory biology. The putative magnetoreceptor (MagR, previously known as IscA1) is a highly conserved iron-sulfur protein implicated in both magnetoreception and iron metabolism; however, the functional diversity among its cross-species homologs remains poorly understood. Cellular morphology is a key genetically determined trait that can be altered through genetic or environmental modifications—a process known as cell morphology engineering. Constructing engineered cells with specific morphological features and magnetic sensitivity to achieve remote, non-invasive magnetic modulation represents a crucial goal in this field with significant application potential. Therefore, this study aims to systematically investigate the effects of MagR heterologous expression on bacterial morphology and magnetic sensing capabilities, screen for MagR-based magnetically sensitive morphology engineering pathways, and reveal the underlying molecular mechanisms. Methods We systematically screened 28 MagR homologous genes from diverse prokaryotic and animal taxa to evaluate their expression and corresponding phenotypic effects in Escherichia coli (E. coli). To compare the differential magnetic responses among bacteria expressing various recombinant MagR proteins, we utilized high-throughput automated bright-field microscopic imaging and scanning electron microscopy (SEM). Furthermore, comprehensive biochemical and biophysical characterizations of iron and iron-sulfur cluster binding were performed using Ferrozine colorimetric assays, electron paramagnetic resonance (EPR) spectroscopy, ultraviolet-visible (UV-Vis) absorption, and circular dichroism (CD) spectroscopy. Additionally, 100 mT static magnetic field (SMF) exposure experiments were conducted to assess magnetically tunable phenotypes, while the intrinsic magnetic properties of purified MagR proteins were directly measured using a superconducting quantum interference device (SQUID) magnetometer. Results Our results demonstrated that the heterologous expression of MagR homologs induced varying degrees of bacterial filamentation. From this comprehensive screen, two distinct morphological patterns were identified: hydra (Hydra vulgaris) MagR (hyMagR) promoted uniform cell elongation and filamentation, exhibiting robust magnetic sensitivity manifested as significantly enhanced filamentation under the 100 mT SMF. In contrast, pigeon (Columba livia) MagR (clMagR) induced only low-frequency, extreme filamentation (sporadically exceeding 80 μm) with a relatively weaker magnetic morphological response. Mechanistically, our data unambiguously proved that these phenotypic differences are primarily driven by distinct iron redox preferences rather than total cellular iron accumulation. Specifically, hyMagR preferentially binds ferrous iron (Fe2+), whereas clMagR favors ferric iron (Fe3+) and forms more stable iron-sulfur clusters. Intriguingly, although SQUID magnetometry showed that purified clMagR exhibited approximately five-fold higher mass magnetic susceptibility than hyMagR, its cellular magnetic response was weaker. We hypothesize that the Fe2+-preferred intracellular environment associated with hyMagR overexpression primes the cell for enhanced generation of reactive oxygen species (ROS) via the Fenton reaction. Exposure to an SMF synergizes with this primed redox state, triggering the bacterial SOS response and upregulating cell division inhibitors to efficiently induce uniform filamentation. Conclusion Our findings identify the Fe2+/Fe3+ redox state as a critical determinant of MagR-mediated morphological remodeling and magnetic responsiveness. This discovery suggests a potential strategy for engineering magnetically responsive cellular systems for synthetic biology applications, and provides a plausible framework, which potentially combines intrinsic protein magnetism with redox-state modulation, for further investigating the evolutionary mechanisms of MagR-mediated magnetoreception.
3.Exploring behavioral patterns and hippocampal neurogenesis in autism spectrum disorder mice
Xiao-Jie NIU ; Jiao LIU ; Xin-Wei ZHANG ; Ze-Tao WANG ; Ke-Qi YAN ; Qi-Yuan LIU ; Wan-Yun HAO ; Pei-Jun ZHANG
Acta Anatomica Sinica 2025;56(2):171-179
Objective To explore the behavioral patterns and hippocampal neurogenesis of CHD8+mice,and to provide behavioral and morphological basis for improving autism like behavior and neurogenesis.Methods Genotype of wild type(WT)and CHD8+/-mice was identified.Weight measurement was conducted on both male and female mice of the WT and CHD8+/-strains.Subsequently,a battery of behavioral tests was administered,which included three-chamber test,self-grooming test,nesting test,Y-maze spontaneous alternation test,food burial test,open-field test and light-dark transition test.Afterwards,the mice were administered 2%pentobarbital sodium(2 ml/kg)to induce anesthesia.Their brains were frozen with 4%paraformaldehyde,removed for photography and analysis to identify any alterations in brain size.Western blotting and immunofluorescent labeling were used to detect changes in the process of hippocampus neurogenesis.Results Western blotting analysis demonstrated a decrease in the amounts of chromodomain helicase DNA binding protein 8(CHD8)protein in both male and female mice with CHD8+genotype,as compared to WT mice.There were no notable disparities in body weight between male and female WT and CHD8+mice,as well as in brain size.The three-chamber social behavior test revealed that both male and female CHD8+/-mice had social deficiencies(P<0.05).During the open field test,there was no significant difference in the total distance moved by male and female WT and CHD8+/-mice.However,the amount of time spent in the central region was considerably lower in CHD8+/-mice compared to the WT mice(P<0.01).Furthermore,the light-dark transition test revealed that both male and female CHD8+/-mice spent considerably less time investigating the white box compared to the WT mice(P<0.05).Nevertheless,there were no notable alterations found in self-grooming,nesting,spontaneous alternation of Y-maze,and food burial experiments.In addition,Western blotting result demonstrated a significant drop in doublecortin(DCX)expression(P<0.001),and immunofluorescent staining revealed a notable reduction in the number of DCX+cells(P<0.01)in the hippocampus of CHD8+/-mice.Conclusion CHD8+/-mice exhibit social disorders and anxiety-like behaviors,with a decrease in the number of newly generated neurons in the hippocampus and neurogenesis disorders.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Effects of rice wine type and wine processing method on chemical constituents and anti-coagulation effect of Angelicae sinensis Radix
Ying WANG ; Ya-yi DENG ; Xue-qi GE ; Hui ZHU ; Yu DUAN ; Xiao-ning YAN ; Hao CAI ; Ke PEI
Chinese Traditional Patent Medicine 2025;47(5):1443-1448
AIM To investigate the effects of rice wine type and wine processing method on chemical constituents and anti-coagulation effect of Angelicae sinensis Radix.METHODS Wine-washed products and wine-stir-fried products were prepared by different types and ages of rice wine,respectively,after which HPLC was adopted in the content determination of tryptophan,chlorogenic acid,vanillic acid,phthalic acid,ferulic acid,senkyunolide I,senkyunolide H,coniferyl ferulate and ligustilide,and PT,APTT,TT were detected in rabbit plasma.RESULTS Phenolic acids and volatile constituents demonstrated lower contents in the wine-stir-fried products than those in the raw product(P<0.05),while those in the wine-washed products displayed no obvious changes(except for senkyunolide I)(P>0.05).The contents of volatile constituents in the wine-washed products were higher than those in the wine-stir-fried products(P<0.05).After being processed with dry rice wine,various constituents exhibited increased contents as compared with those after being processed with sweet rice wine(P<0.05).Compared with the raw product,prolonged PT,APTT and TT were observable in the processed products prepared by 3-year semi-dry rice wine(P<0.05).CONCLUSION The optimal rice wine type is determined to be 3-year semi-dry.Wine-washed Angelicae sinensis Radix shows high contents of ferulic acid and volatile constituents,whose activating blood and resolving stasis effect may be stronger.
6.Effects of honey-processed Astragalus on energy metabolism and polarization of RAW264.7 cells
Hong-chang LI ; Ke PEI ; Wang-yang XIE ; Xiang-long MENG ; Zi-han YU ; Wen-ling LI ; Hao CAI
Acta Pharmaceutica Sinica 2025;60(2):459-470
In this study, RAW264.7 cells were employed to investigate the effects of honey-processed
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail