1.Planning evaluation of stereotactic magnetic resonance–guided online adaptive radiosurgery for kidney tumors close to the organ at risk: is it valuable to wait for good timing to perform stereotactic radiosurgery?
Takaya YAMAMOTO ; Shohei TANAKA ; Noriyoshi TAKAHASHI ; Rei UMEZAWA ; Yu SUZUKI ; Keita KISHIDA ; So OMATA ; Kazuya TAKEDA ; Hinako HARADA ; Kiyokazu SATO ; Yoshiyuki KATSUTA ; Noriyuki KADOYA ; Keiichi JINGU
Radiation Oncology Journal 2025;43(1):40-48
Purpose:
This study aimed to investigate changes in target coverage using magnetic resonance–guided online adaptive radiotherapy (MRgoART) for kidney tumors and to evaluate the suitable timing of treatment.
Materials and Methods:
Among patients treated with 3-fraction MRgoART for kidney cancer, 18 tumors located within 1 cm of the gastrointestinal tract were selected. Stereotactic radiosurgery planning with a prescription dose of 26 Gy was performed using pretreatment simulation and three MRgoART timings with an adapt-to-shape method. The best MRgoART plan was defined as the plan achieving the highest percentage of planning target volume (PTV) coverage of 26 Gy. In clinical scenario simulation, MRgoART plans were evaluated in the order of actual treatment. Waiting for the next timing was done when the PTV coverage of 26 Gy did not achieve 95%–99% or did not increase by 5% or more compared to the pretreatment plan.
Results:
The median percentages of PTV receiving 26 Gy in pretreatment and the first, second, and third MRgoART were 82% (range, 19%), 63% (range, 7% to 99%), 88% (range, 31% to 99%), and 95% (range, 3% to 99%), respectively. Comparing pretreatment simulation plans with the best MRgoART plans showed a significant difference (p = 0.025). In the clinical scenario simulation, 16 of the 18 planning series, including nine plans with 95%–99% PTV coverage of 26 Gy and seven plans with increased PTV coverage by 5% or more, would be irradiated at a good timing.
Conclusion
MRgoART revealed dose coverage differences at each MRgoART timing. Waiting for optimal irradiation timing could be an option in case of suboptimal timing.
2.Changes in Sleep Quality after Hormone Replacement Therapy with Micronized Progesterone in Japanese Menopausal Women: A Pilot Study
Mariko OGAWA ; Kazuya MAKITA ; Kiyoshi TAKAMATSU ; Toshifumi TAKAHASHI
Journal of Menopausal Medicine 2025;31(1):45-50
Sleep disturbances are common among women during menopause. Hormone replacement therapy (HRT) using micronized progesterone (MP) may improve sleep, owing to its neurosteroid effects. Studies on the impact of oral MP on sleep quality in Japanese women are limited, given the recent introduction of MP in Japan. We conducted a single-arm, open-label study to examine the effects of HRT with estradiol (E2) and oral MP on sleep quality in 15 peri- and postmenopausal Japanese women who chose HRT to address their menopausal symptoms. The participants completed the Pittsburgh Sleep Quality Index (PSQI) and menopausal symptoms questionnaires at baseline, 1 month, and 3 months after HRT. The changes in PSQI scores were evaluated. Responders were defined as those with a ≥ 25% reduction in the PSQI global score at 1 month. The PSQI components and menopausal symptoms at baseline were compared between responders and non-responders. Initially, 86.7% of the participants were categorized as poor sleepers. The PSQI global score and sleep quality significantly improved at 1 and 3 months after HRT (baseline to 3rd month mean scores: from 7.8 to 6.1 to 6.5 and from 1.7 to 1.0 to 1.2, respectively). Responders (n = 5) exhibited poorer habitual sleep efficiency before treatment than the non-responders.However, menopausal symptoms did not differ significantly between the groups at baseline. The results indicate that HRT with E2 and MP is a promising treatment option for peri- and postmenopausal Japanese women experiencing sleep disturbances, especially those with poor sleep efficiency.
3.Planning evaluation of stereotactic magnetic resonance–guided online adaptive radiosurgery for kidney tumors close to the organ at risk: is it valuable to wait for good timing to perform stereotactic radiosurgery?
Takaya YAMAMOTO ; Shohei TANAKA ; Noriyoshi TAKAHASHI ; Rei UMEZAWA ; Yu SUZUKI ; Keita KISHIDA ; So OMATA ; Kazuya TAKEDA ; Hinako HARADA ; Kiyokazu SATO ; Yoshiyuki KATSUTA ; Noriyuki KADOYA ; Keiichi JINGU
Radiation Oncology Journal 2025;43(1):40-48
Purpose:
This study aimed to investigate changes in target coverage using magnetic resonance–guided online adaptive radiotherapy (MRgoART) for kidney tumors and to evaluate the suitable timing of treatment.
Materials and Methods:
Among patients treated with 3-fraction MRgoART for kidney cancer, 18 tumors located within 1 cm of the gastrointestinal tract were selected. Stereotactic radiosurgery planning with a prescription dose of 26 Gy was performed using pretreatment simulation and three MRgoART timings with an adapt-to-shape method. The best MRgoART plan was defined as the plan achieving the highest percentage of planning target volume (PTV) coverage of 26 Gy. In clinical scenario simulation, MRgoART plans were evaluated in the order of actual treatment. Waiting for the next timing was done when the PTV coverage of 26 Gy did not achieve 95%–99% or did not increase by 5% or more compared to the pretreatment plan.
Results:
The median percentages of PTV receiving 26 Gy in pretreatment and the first, second, and third MRgoART were 82% (range, 19%), 63% (range, 7% to 99%), 88% (range, 31% to 99%), and 95% (range, 3% to 99%), respectively. Comparing pretreatment simulation plans with the best MRgoART plans showed a significant difference (p = 0.025). In the clinical scenario simulation, 16 of the 18 planning series, including nine plans with 95%–99% PTV coverage of 26 Gy and seven plans with increased PTV coverage by 5% or more, would be irradiated at a good timing.
Conclusion
MRgoART revealed dose coverage differences at each MRgoART timing. Waiting for optimal irradiation timing could be an option in case of suboptimal timing.
4.Planning evaluation of stereotactic magnetic resonance–guided online adaptive radiosurgery for kidney tumors close to the organ at risk: is it valuable to wait for good timing to perform stereotactic radiosurgery?
Takaya YAMAMOTO ; Shohei TANAKA ; Noriyoshi TAKAHASHI ; Rei UMEZAWA ; Yu SUZUKI ; Keita KISHIDA ; So OMATA ; Kazuya TAKEDA ; Hinako HARADA ; Kiyokazu SATO ; Yoshiyuki KATSUTA ; Noriyuki KADOYA ; Keiichi JINGU
Radiation Oncology Journal 2025;43(1):40-48
Purpose:
This study aimed to investigate changes in target coverage using magnetic resonance–guided online adaptive radiotherapy (MRgoART) for kidney tumors and to evaluate the suitable timing of treatment.
Materials and Methods:
Among patients treated with 3-fraction MRgoART for kidney cancer, 18 tumors located within 1 cm of the gastrointestinal tract were selected. Stereotactic radiosurgery planning with a prescription dose of 26 Gy was performed using pretreatment simulation and three MRgoART timings with an adapt-to-shape method. The best MRgoART plan was defined as the plan achieving the highest percentage of planning target volume (PTV) coverage of 26 Gy. In clinical scenario simulation, MRgoART plans were evaluated in the order of actual treatment. Waiting for the next timing was done when the PTV coverage of 26 Gy did not achieve 95%–99% or did not increase by 5% or more compared to the pretreatment plan.
Results:
The median percentages of PTV receiving 26 Gy in pretreatment and the first, second, and third MRgoART were 82% (range, 19%), 63% (range, 7% to 99%), 88% (range, 31% to 99%), and 95% (range, 3% to 99%), respectively. Comparing pretreatment simulation plans with the best MRgoART plans showed a significant difference (p = 0.025). In the clinical scenario simulation, 16 of the 18 planning series, including nine plans with 95%–99% PTV coverage of 26 Gy and seven plans with increased PTV coverage by 5% or more, would be irradiated at a good timing.
Conclusion
MRgoART revealed dose coverage differences at each MRgoART timing. Waiting for optimal irradiation timing could be an option in case of suboptimal timing.
5.Changes in Sleep Quality after Hormone Replacement Therapy with Micronized Progesterone in Japanese Menopausal Women: A Pilot Study
Mariko OGAWA ; Kazuya MAKITA ; Kiyoshi TAKAMATSU ; Toshifumi TAKAHASHI
Journal of Menopausal Medicine 2025;31(1):45-50
Sleep disturbances are common among women during menopause. Hormone replacement therapy (HRT) using micronized progesterone (MP) may improve sleep, owing to its neurosteroid effects. Studies on the impact of oral MP on sleep quality in Japanese women are limited, given the recent introduction of MP in Japan. We conducted a single-arm, open-label study to examine the effects of HRT with estradiol (E2) and oral MP on sleep quality in 15 peri- and postmenopausal Japanese women who chose HRT to address their menopausal symptoms. The participants completed the Pittsburgh Sleep Quality Index (PSQI) and menopausal symptoms questionnaires at baseline, 1 month, and 3 months after HRT. The changes in PSQI scores were evaluated. Responders were defined as those with a ≥ 25% reduction in the PSQI global score at 1 month. The PSQI components and menopausal symptoms at baseline were compared between responders and non-responders. Initially, 86.7% of the participants were categorized as poor sleepers. The PSQI global score and sleep quality significantly improved at 1 and 3 months after HRT (baseline to 3rd month mean scores: from 7.8 to 6.1 to 6.5 and from 1.7 to 1.0 to 1.2, respectively). Responders (n = 5) exhibited poorer habitual sleep efficiency before treatment than the non-responders.However, menopausal symptoms did not differ significantly between the groups at baseline. The results indicate that HRT with E2 and MP is a promising treatment option for peri- and postmenopausal Japanese women experiencing sleep disturbances, especially those with poor sleep efficiency.
6.Planning evaluation of stereotactic magnetic resonance–guided online adaptive radiosurgery for kidney tumors close to the organ at risk: is it valuable to wait for good timing to perform stereotactic radiosurgery?
Takaya YAMAMOTO ; Shohei TANAKA ; Noriyoshi TAKAHASHI ; Rei UMEZAWA ; Yu SUZUKI ; Keita KISHIDA ; So OMATA ; Kazuya TAKEDA ; Hinako HARADA ; Kiyokazu SATO ; Yoshiyuki KATSUTA ; Noriyuki KADOYA ; Keiichi JINGU
Radiation Oncology Journal 2025;43(1):40-48
Purpose:
This study aimed to investigate changes in target coverage using magnetic resonance–guided online adaptive radiotherapy (MRgoART) for kidney tumors and to evaluate the suitable timing of treatment.
Materials and Methods:
Among patients treated with 3-fraction MRgoART for kidney cancer, 18 tumors located within 1 cm of the gastrointestinal tract were selected. Stereotactic radiosurgery planning with a prescription dose of 26 Gy was performed using pretreatment simulation and three MRgoART timings with an adapt-to-shape method. The best MRgoART plan was defined as the plan achieving the highest percentage of planning target volume (PTV) coverage of 26 Gy. In clinical scenario simulation, MRgoART plans were evaluated in the order of actual treatment. Waiting for the next timing was done when the PTV coverage of 26 Gy did not achieve 95%–99% or did not increase by 5% or more compared to the pretreatment plan.
Results:
The median percentages of PTV receiving 26 Gy in pretreatment and the first, second, and third MRgoART were 82% (range, 19%), 63% (range, 7% to 99%), 88% (range, 31% to 99%), and 95% (range, 3% to 99%), respectively. Comparing pretreatment simulation plans with the best MRgoART plans showed a significant difference (p = 0.025). In the clinical scenario simulation, 16 of the 18 planning series, including nine plans with 95%–99% PTV coverage of 26 Gy and seven plans with increased PTV coverage by 5% or more, would be irradiated at a good timing.
Conclusion
MRgoART revealed dose coverage differences at each MRgoART timing. Waiting for optimal irradiation timing could be an option in case of suboptimal timing.
7.Changes in Sleep Quality after Hormone Replacement Therapy with Micronized Progesterone in Japanese Menopausal Women: A Pilot Study
Mariko OGAWA ; Kazuya MAKITA ; Kiyoshi TAKAMATSU ; Toshifumi TAKAHASHI
Journal of Menopausal Medicine 2025;31(1):45-50
Sleep disturbances are common among women during menopause. Hormone replacement therapy (HRT) using micronized progesterone (MP) may improve sleep, owing to its neurosteroid effects. Studies on the impact of oral MP on sleep quality in Japanese women are limited, given the recent introduction of MP in Japan. We conducted a single-arm, open-label study to examine the effects of HRT with estradiol (E2) and oral MP on sleep quality in 15 peri- and postmenopausal Japanese women who chose HRT to address their menopausal symptoms. The participants completed the Pittsburgh Sleep Quality Index (PSQI) and menopausal symptoms questionnaires at baseline, 1 month, and 3 months after HRT. The changes in PSQI scores were evaluated. Responders were defined as those with a ≥ 25% reduction in the PSQI global score at 1 month. The PSQI components and menopausal symptoms at baseline were compared between responders and non-responders. Initially, 86.7% of the participants were categorized as poor sleepers. The PSQI global score and sleep quality significantly improved at 1 and 3 months after HRT (baseline to 3rd month mean scores: from 7.8 to 6.1 to 6.5 and from 1.7 to 1.0 to 1.2, respectively). Responders (n = 5) exhibited poorer habitual sleep efficiency before treatment than the non-responders.However, menopausal symptoms did not differ significantly between the groups at baseline. The results indicate that HRT with E2 and MP is a promising treatment option for peri- and postmenopausal Japanese women experiencing sleep disturbances, especially those with poor sleep efficiency.
8.Planning evaluation of stereotactic magnetic resonance–guided online adaptive radiosurgery for kidney tumors close to the organ at risk: is it valuable to wait for good timing to perform stereotactic radiosurgery?
Takaya YAMAMOTO ; Shohei TANAKA ; Noriyoshi TAKAHASHI ; Rei UMEZAWA ; Yu SUZUKI ; Keita KISHIDA ; So OMATA ; Kazuya TAKEDA ; Hinako HARADA ; Kiyokazu SATO ; Yoshiyuki KATSUTA ; Noriyuki KADOYA ; Keiichi JINGU
Radiation Oncology Journal 2025;43(1):40-48
Purpose:
This study aimed to investigate changes in target coverage using magnetic resonance–guided online adaptive radiotherapy (MRgoART) for kidney tumors and to evaluate the suitable timing of treatment.
Materials and Methods:
Among patients treated with 3-fraction MRgoART for kidney cancer, 18 tumors located within 1 cm of the gastrointestinal tract were selected. Stereotactic radiosurgery planning with a prescription dose of 26 Gy was performed using pretreatment simulation and three MRgoART timings with an adapt-to-shape method. The best MRgoART plan was defined as the plan achieving the highest percentage of planning target volume (PTV) coverage of 26 Gy. In clinical scenario simulation, MRgoART plans were evaluated in the order of actual treatment. Waiting for the next timing was done when the PTV coverage of 26 Gy did not achieve 95%–99% or did not increase by 5% or more compared to the pretreatment plan.
Results:
The median percentages of PTV receiving 26 Gy in pretreatment and the first, second, and third MRgoART were 82% (range, 19%), 63% (range, 7% to 99%), 88% (range, 31% to 99%), and 95% (range, 3% to 99%), respectively. Comparing pretreatment simulation plans with the best MRgoART plans showed a significant difference (p = 0.025). In the clinical scenario simulation, 16 of the 18 planning series, including nine plans with 95%–99% PTV coverage of 26 Gy and seven plans with increased PTV coverage by 5% or more, would be irradiated at a good timing.
Conclusion
MRgoART revealed dose coverage differences at each MRgoART timing. Waiting for optimal irradiation timing could be an option in case of suboptimal timing.
9.Dynamic Cervical Spinal Canal Stenosis: Identifying Imaging Risk Factors in Extended Positions
Shogo MATSUMOTO ; Ryoma AOYAMA ; Junichi YAMANE ; Ken NINOMIYA ; Yuichiro TAKAHASHI ; Kazuya KITAMURA ; Satoshi NORI ; Satoshi SUZUKI ; Ukei ANAZAWA ; Tateru SHIRAISHI
Asian Spine Journal 2024;18(2):227-235
Methods:
This study analyzed 143 patients who underwent decompression surgery between 2012 and 2014, who had symptomatic cervical disorders and MRI evidence of spinal cord or nerve compression but had no history of cervical spine surgery. Patient demographics, disease type, Japanese Orthopedic Association score, and follow-up periods were recorded. Spinal surgeons conducted radiological evaluations to determine stenosis levels using computed tomography myelography or MRI in neutral and extended positions. Measurements such as dural tube and spinal cord diameters, cervical alignment, range of motion, and various angles and distances were also analyzed. The residual space available for the spinal cord (SAC) was also calculated.
Results:
During extension, new stenosis frequently appeared caudal to the stenosis site in a neutral position, particularly at C5/C6 and C6/C7. A low SAC was identified as a significant risk factor for the development of new stenosis in both the upper and lower adjacent disc levels. Each 1-mm decrease in SAC resulted in an 8.9- and 2.7-fold increased risk of new stenosis development in the upper and lower adjacent disc levels, respectively. A practical SAC cutoff of 1.0 mm was established as the threshold for new stenosis development.
Conclusions
The study identified SAC narrowing as the primary risk factor for new stenosis, with a clinically relevant cutoff of 1 mm. This study highlights the importance of local factors in stenosis development, advocating for further research to improve outcomes in patient with cervical spine disorders.
10.The Effect of Pharmacists’ Explanation on Young Patients Switching to Generic Drugs Usage
Hideaki HIRAGA ; Kumi KAWASHIMA ; Sayaka KOUNO ; Susumu OKU ; Kenichi TAKAHASHI ; Kazuya SAITO
Japanese Journal of Drug Informatics 2023;25(2):67-75
Objective: To keep medical costs down, it is important to promote the use of generic drugs at pharmacies, where prescription volumes are high. However, many parents do not opt for generic drugs. This study examines the effectiveness of pharmacists’ explanations to parents, with the aim of promoting the use of generic drugs among young patients under the age of 20.Method: A questionnaire-based survey was conducted from November 25 to December 1, 2019, at 129 pharmacies.Results: During the survey period, 91 pharmacies received 4,491 prescriptions from young patients. The percentage of generic drugs dispensed per prescription was lower for the young patients than for adult patients (65.4% vs. 70.4%; p < 0.001). Statistically, the percentage of prescriptions dispensed using generic drugs was higher in pharmacies that explained costs, equivalence of quality and efficacy, safety, side effects, and the trial system (divided dispensing), compared to pharmacies that did not use these explanations. Conversely, the percentage of prescriptions dispensed using generic drugs was lower at pharmacies that explained dosage form and ease of swallowing. Many pharmacies explained the equivalence of quality and efficacy (85.7%), with many questions from parents (82.4%). However, only a few pharmacies explained the trial system (divided dispensing) (1.1%), with no questions raised by parents (0.0%).Conclusion: This study found that pharmacists’ explanations are effective in promoting the use generic drugs for young patients. However, there is a lack of awareness among parents about the trial system (divided dispensing), and public institutions and pharmacists are not responding appropriately. To promote generic drug usage among young patients, it is important to develop educational tools regarding the trial system (divided dispensing), create awareness campaigns for parents, and revise medical fee. Furthermore, to ensure safe drug therapy, pharmacists should also provide information on the appearance and taste of generic drugs.


Result Analysis
Print
Save
E-mail