1.Assessment of colorectal polyp detection along the short-axis direction of the intestinal lumen during colonoscopic observation: a retrospective study in Japan
Daichi MORI ; Atsushi KATAGIRI ; Yoshinao ONISHI ; Yuta YAMAZAKI ; Kensuke HIGUCHI ; Norihiro SUZUKI ; Kazuo KIKUCHI ; Shinya NAKATANI ; Takahisa FUJIWARA ; Kazuya INOKI ; Kenichi KONDA ; Masayuki TOJO ; Fuyuhiko YAMAMURA ; Hitoshi YOSHIDA
Clinical Endoscopy 2026;59(1):96-105
Background/Aims:
Colorectal polyp detection during colonoscopy is influenced by the lesion location, size, morphology, and histology. However, no studies have systematically assessed the difficulty of detection along the short axis of the intestinal lumen. This study aimed to evaluate the colorectal polyp detection rates on this axis during colonoscopy.
Methods:
This retrospective study analyzed 1,169 polyps in 513 patients who underwent colonoscopy at Showa University Hospital between November 2022 and February 2023. The short-axis lumen was divided into: upper right, lower right, lower left, and upper left. Each polyp detected was assigned to a quadrant. Detection rates were compared across quadrants and analyzed for associations with clinicopathological factors including lesion size, location, macroscopic type, and examiner experience.
Results:
The lesion detection rates varied significantly by quadrant. The upper left quadrant had the lowest detection rate (17.5%) compared with the expected 25.0% per quadrant. Subgroup analyses consistently confirmed the lower detection rates in this quadrant across most lesion types and patient groups, except for lesions in the cecum and rectum.
Conclusions
The lower detection rate in the upper left quadrant suggests that this orientation poses a challenge and may increase the number of missed lesions. Enhanced examination of this area may improve detection; however, further prospective studies are required.
2.Reduced Intravenous Fluorescein Dose for Upper and Lower Gastrointestinal Tract Probe-Based Confocal Laser Endomicroscopy
Kazuya INOKI ; Seiichiro ABE ; Yusaku TANAKA ; Koji YAMAMOTO ; Daisuke HIHARA ; Ryoji ICHIJIMA ; Yukihiro NAKATANI ; HsinYu CHEN ; Hiroyuki TAKAMARU ; Masau SEKIGUCHI ; Masayoshi YAMADA ; Taku SAKAMOTO ; Satoru NONAKA ; Haruhisa SUZUKI ; Shigetaka YOSHINAGA ; Ichiro ODA ; Takahisa MATSUDA ; Yutaka SAITO
Clinical Endoscopy 2021;54(3):363-370
Background/Aims:
Probe-based confocal laser endomicroscopy (pCLE) requires the administration of intravenous (IV) fluorescein. This study aimed to determine the optimal dose of IV fluorescein for both upper and lower gastrointestinal (GI) tract pCLE.
Methods:
Patients 20 to 79 years old with gastric high-grade dysplasia (HGD) or colorectal neoplasms (CRNs) were enrolled in the study. The dose de-escalation method was employed with five levels. The primary endpoint of the study was the determination of the optimal dose of IV fluorescein for pCLE of the GI tract. The reduced dose was determined based on off-line reviews by three endoscopists. An insufficient dose of fluorescein was defined as the dose of fluorescein with which the pCLE images were not deemed to be visible. If all three endoscopists determined that the tissue structure was visible, the doses were de-escalated.
Results:
A total of 12 patients with gastric HGD and 12 patients with CRNs were enrolled in the study. Doses were de-escalated to 0.5 mg/kg of fluorescein for both non-neoplastic duodenal and colorectal mucosa. All gastric HGD or CRNs were visible with pCLE with IV fluorescein at 0.5 mg/kg.
Conclusions
In the present study, pCLE with IV fluorescein 0.5 mg/kg was adequate to visualize the magnified structure of both the upper and lower GI tract.
3.Reduced Intravenous Fluorescein Dose for Upper and Lower Gastrointestinal Tract Probe-Based Confocal Laser Endomicroscopy
Kazuya INOKI ; Seiichiro ABE ; Yusaku TANAKA ; Koji YAMAMOTO ; Daisuke HIHARA ; Ryoji ICHIJIMA ; Yukihiro NAKATANI ; HsinYu CHEN ; Hiroyuki TAKAMARU ; Masau SEKIGUCHI ; Masayoshi YAMADA ; Taku SAKAMOTO ; Satoru NONAKA ; Haruhisa SUZUKI ; Shigetaka YOSHINAGA ; Ichiro ODA ; Takahisa MATSUDA ; Yutaka SAITO
Clinical Endoscopy 2021;54(3):363-370
Background/Aims:
Probe-based confocal laser endomicroscopy (pCLE) requires the administration of intravenous (IV) fluorescein. This study aimed to determine the optimal dose of IV fluorescein for both upper and lower gastrointestinal (GI) tract pCLE.
Methods:
Patients 20 to 79 years old with gastric high-grade dysplasia (HGD) or colorectal neoplasms (CRNs) were enrolled in the study. The dose de-escalation method was employed with five levels. The primary endpoint of the study was the determination of the optimal dose of IV fluorescein for pCLE of the GI tract. The reduced dose was determined based on off-line reviews by three endoscopists. An insufficient dose of fluorescein was defined as the dose of fluorescein with which the pCLE images were not deemed to be visible. If all three endoscopists determined that the tissue structure was visible, the doses were de-escalated.
Results:
A total of 12 patients with gastric HGD and 12 patients with CRNs were enrolled in the study. Doses were de-escalated to 0.5 mg/kg of fluorescein for both non-neoplastic duodenal and colorectal mucosa. All gastric HGD or CRNs were visible with pCLE with IV fluorescein at 0.5 mg/kg.
Conclusions
In the present study, pCLE with IV fluorescein 0.5 mg/kg was adequate to visualize the magnified structure of both the upper and lower GI tract.

Result Analysis
Print
Save
E-mail