1.Expert consensus on clinical application of parenteral direct thrombin inhibitors in perioperative period
Mingyu JIANG ; Yuan BIAN ; Lizhu HAN ; Qinan YIN ; Fengjiao KANG ; Anhua WEI ; Danjie ZHAO ; Lin WANG ; Ying SHAO ; Li TANG ; Yi WANG ; Shuhong LIANG ; Huijuan LIU ; Guirong XIAO ; Yue LI
China Pharmacy 2026;37(6):689-699
OBJECTIVE To form an expert consensus on the clinical application of parenteral direct thrombin inhibitors (DTIs) in patients during the perioperative period. METHODS Led by Sichuan Academy of Medical Sciences & Sichuan Provincial People’s Hospital (the Affiliated Hospital of UESTC), a multidisciplinary working group was established. Through literature review and the Delphi method, clinical questions related to the rational perioperative use of parenteral DTIs were identified. A structured design was adopted using the “Population-Intervention-Comparison-Outcome” framework; systematic searches were conducted in CNKI, Medline, Embase and other databases. Relevant evidence from randomized controlled trials and cohort studies was included and synthesized. Evidence quality was assessed using the Grades of Recommendations Assessment,Development and Evaluation (GRADE) approach, and recommendations were formulated through multiple rounds of Delphi surveys and expert consensus meetings. RESULTS &CONCLUSIONS Seven recommendations (each with an expert consensus rate exceeding 90%) on the use of parenteral DTIs in perioperative patients were developed. These recommendations specify drug selection, dosing ranges, key monitoring points, and safety management strategies for parenteral DTIs in various scenarios, including the perioperative period of ventricular assist device implantation, the perioperative period of cardiac surgery, perioperative patients with lower-extremity atherosclerotic disease, the perioperative period of percutaneous coronary intervention in patients with acute coronary syndrome, the perioperative period of carotid artery stenting in patients with carotid stenosis, the perioperative period of patients with right heart thrombosis, and patients who develop related thrombosis and dysfunction after a central venous catheter insertion. In addition, warning and management pathways for perioperative bleeding and thrombotic events were proposed. This expert consensus, which is formulated based on the best available evidence, provides evidence-based guidance for standardized and individualized use of parenteral DTIs in perioperative period.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Short-term clinical efficacy of unilateral external fixator combined with percutaneous Kirschner wire fixation in the treatment of type C1 distal radius fractures in elderly patients.
Run-Bin SHEN ; Guo-Liang LI ; Xiao-Ping LIU ; Kang CHEN ; Guang-Pu HAN ; Jian-Yong ZHAO
China Journal of Orthopaedics and Traumatology 2025;38(1):25-30
OBJECTIVE:
To investigate the short-term clinical effect of closed reduction single arm external fixator combined with percutaneous needle fixation in the treatment of C1 distal radius fracture in elderly patients.
METHODS:
Between December 2022 and December 2023, a total of 60 elderly patients diagnosed with type C1 distal radius fractures were treated, comprising 9 males and 51 females. The age ranged from 65 to 84 years old, with an average of (72.69±8.14) years old. Among them, there were 18 cases on the left side and 42 cases on the right side. There were 55 cases of falling injury and 5 cases of traffic accident injury. According to the different surgical methods, the patients were divided into observation group and control group, with 30 cases in each group. The control group underwent manual reduction and unilateral external fixator fixation, consisting of 4 males and 26 females. The mean age was (72.54±8.67) years old. The body mass index (BMI) was (20.61±2.17) kg·m-2. There were 10 cases on the left side and 20 cases on the right side. Among them, there were 27 cases of falling injury and 3 cases of traffic accident injury. The observation group was treated with manual reduction and unilateral external fixator combined with percutaneous Kirschner wire fixation, including 5 males and 25 females. The mean age was (72.76±7.23) years old. BMI (20.82±2.03) kg·m-2. The left side was involved in 8 cases and the right side in 22 cases. There were 28 cases of falling injury and 2 cases of traffic accident injury. The changes in radial height, ulnar declination, palmar inclination angle parameters and patient-rated wrist evaluation (PRWE) were assessed on X-ray films before surgery, 2 days after surgery, and 12 weeks after surgery between the two groups.
RESULTS:
All surgical procedures were successfully completed in both groups without any significant complications. All patients were followed up for a duration from 12 to 20 weeks with an average of(14.50±2.78) weeks. The two groups exhibited significant differences in radial height, palmar inclination angle, and ulnar deviation angle at 2 days and 12 weeks post-operation (P<0.05). However, there was no statistically significant difference observed in radial height, palmar inclination, and ulnar deviation between the two groups at 2 days after the operation (P>0.05). There were significant differences in radial height, palmar inclination angle, and ulnar deviation between the two groups at 12 weeks after operation (P<0.05). At 2 days and 12 weeks after the operation, there were significant differences in PRWE scores of the two groups compared with preoperative scores(P<0.05). At 2 days after the operation, there was no significant difference in PRWE score between the two groups (P>0.05). The PRWE score showed a significant difference between the two groups at 12 weeks post-operation(P<0.05).
CONCLUSION
The combination of closed reduction and unilateral external fixator, along with percutaneous pin fixation provides move stable fixation for type C1 distal radius fractures. Gradual removal of external fixator further facilitatse the recovery of wrist joint function.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
External Fixators
;
Aged
;
Aged, 80 and over
;
Bone Wires
;
Fracture Fixation/instrumentation*
;
Wrist Fractures
7.Scoparone inhibits proliferation and invasion of colon cancer cell line HCT116
Wei HAN ; Wei PAN ; Man ZHANG ; Xiangyu GAO ; Xinkai KANG ; Zhibo ZHU ; Ruiting LIU
Basic & Clinical Medicine 2025;45(11):1429-1437
Objective To investigate the effects of scoparone(Sco)on proliferation and invasion of colon cancer cell line HCT116,and its effect on the expression of epidermal growth factor receptor(EGFR).Methods 1)HCT116 cells were divided into control group,50Sco group,100Sco group and 200Sco group.The cells in con-trol group were incubated with culture medium for 48 hrs.The 50Sco group,100Sco group and 200Sco group were incubated with 50,100 and 200 μmol/L scoparone for 48 hrs respectively.2)HCT116 cells were divided into con-trol group,NC-200Sco group,NC-LV+200Sco group and EGFR-LV+200Sco group.The control group was incuba-ted with normal culture medium for 48 hrs.NC-200Sco group was incubated with 200 μmol/L scoparone for 48 hrs.NC-LV and EGFR-LV were infected into HCT116 cells in NC-LV+200Sco group and EGFR-LV+200Sco group,then incubated with 200 μmol/L scoparone for 48 hrs.Cell proliferation was detected by MTT assay and EdU stai-ning,cell apoptosis was detected by flow cytometry and cell invasion was detected by Transwell assay.EGFR mRNA was detected by RT-qPCR,the level of EGFR,Bcl-2,Bax,matrix metalloproteinase(MMP)-2 and MMP-9 protein was detected by Western blot.Results Compared to the control group,the cell viability,proportion of EdU positive cells and counting number of invasive cells in 50Sco group,100Sco group and 200Sco group all decreased(P<0.05).Cell apoptosis rate and Bax protein expression increased(P<0.05),the protein expression of Bcl-2,MMP-2 and MMP-9 decreased(P<0.05).mRNA and protein expression of EGFR were de-creased(P<0.05).Compared with NC-200 Sco group and NC-LV+200Sco group,the expression level of mRNA and protein of EGFR in EGFR-LV+200Sco group was increased(P<0.05).Cell viability,proportion of EdU posi-tive cells and counting number of invasive cells all increased(P<0.05).The cell apoptosis rate and Bax protein expression level were decreased(P<0.05).The protein expression of Bcl-2,MMP-2 and MMP-9 was increased(P<0.05).Conclusions Scoparone has anti-colon cancer cell activity and inhibits proliferation as well as invasion of colon cancer cells through inhibition of EGFR.
8.Efficacy and safety of using an enteral immunonutrition formula in the enhanced recovery after surgery protocol for Chinese patients with gastrointestinal cancers undergoing surgery: A randomized, open-label, multicenter trial (healing trial).
Jianchun YU ; Gang XIAO ; Yanbing ZHOU ; Yingjiang YE ; Han LIANG ; Guole LIN ; Qi AN ; Xiaodong LIU ; Bin LIANG ; Baogui WANG ; Weiming KANG ; Tao YU ; Yulong TIAN ; Chao WANG ; Xiaona WANG
Chinese Medical Journal 2025;138(21):2847-2849
9.Development goals and strategies of ecological agriculture of Chinese materia medica.
Chuan-Zhi KANG ; Si-Qi LIU ; Bang-Xing HAN ; Tao ZHOU ; Xiao WANG ; Da-Hui LIU ; Ye YANG ; Lan-Ping GUO
China Journal of Chinese Materia Medica 2025;50(1):42-47
This paper aims to contribute to guaranteeing the stable development and enhancing the understanding of ecological agriculture of Chinese materia medica so that the national strategy and industrial demand can be better served. It first introduces current traditional Chinese medicine(TCM)policy and industrial development status from five aspects, including policy guarantee, theoretical support, technological innovation, standardization system, and brand influence. Then, the paper analyzes the development dilemma of TCM agriculture in production and quality increase and ecological environment protection. It also proposes the development goals of ecological agriculture of Chinese materia medica that meet the current industrial development demand, which are reducing chemical fertilizers, pesticides, and carbon emissions, improving quality, increasing efficiency, and protecting ecological environment. In addition, the new development goals are interpreted through case studies. Finally, this paper proposes four development strategies for ecological agriculture of Chinese materia medica: conducting research on the pattern and spatial and temporal variations of nationwide TCM production areas; studying the internal and external ecological memories of medicinal plant growth from the perspectives of genetic variations and environmental adaptation variations and elucidating their contributions to the formation of quality; carrying out selection and breeding of stress-resistant varieties for ecological agriculture of Chinese materia medica, the optimization of key technologies for soil improvement and restoration and green prevention and control against diseases and pests, and the improvement of quality; carrying out research on the quality assurance and value realization of ecological products made from TCM. This research can provide guidance for policy formulation, theoretical development of the discipline, and the enhancement of industrial technology for ecological agriculture of Chinese materia medica.
Agriculture/methods*
;
China
;
Drugs, Chinese Herbal
;
Plants, Medicinal/chemistry*
;
Ecosystem
;
Materia Medica
;
Medicine, Chinese Traditional
10.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.

Result Analysis
Print
Save
E-mail