1.ERRATUM: Imaging follow-up strategy after endovascular treatment of intracranial aneurysms: A literature review and guideline recommendations
Yong-Hwan CHO ; Jaehyung CHOI ; Chae-Wook HUH ; Chang Hyeun KIM ; Chul Hoon CHANG ; Soon Chan KWON ; Young Woo KIM ; Seung Hun SHEEN ; Sukh Que PARK ; Jun Kyeung KO ; Sung-kon HA ; Hae Woong JEONG ; Hyen Seung KANG ;
Journal of Cerebrovascular and Endovascular Neurosurgery 2025;27(1):80-80
2.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
3.Single port–assisted diverting ileostomy formation for anastomotic leakage after low anterior resection
Kyong-Min KANG ; Heung-Kwon OH ; Hong-min AHN ; Hye-Rim SHIN ; Min-Hyeong JO ; Mi-Jeong CHOI ; Duck-Woo KIM ; Sung-Bum KANG
Journal of Minimally Invasive Surgery 2025;28(1):47-49
Stoma formation for fecal diversion is a common procedure in patients with various complicated conditions after colorectal surgery, such as anastomotic leakage. The singleincision laparoscopic approach for stoma creation offers several advantages, including a reduction in surgical wounds and related complications as well as optimal visualization of the surgical field. This video demonstrates a single-port–assisted diverting ileostomy in a 61-yearold man with anastomotic leakage following low anterior resection for advanced rectal cancer.
4.Spatiotemporal Gait Parameters During Turning and Imbalance in Parkinson’s Disease: Video-Based Analysis From a Single Camera
HoYoung JEON ; Jung Hwan SHIN ; Ri YU ; Min Kyung KANG ; Seungmin LEE ; Seoyeon KIM ; Bora JIN ; Kyung Ah WOO ; Han-Joon KIM ; Beomseok JEON
Journal of Movement Disorders 2025;18(1):87-92
Objective:
This study aims to objectively evaluate turning gait parameters in Parkinson’s disease (PD) patients using 2D-RGB video-based analysis and explore their relationships with imbalance.
Methods:
We prospectively enrolled PD patients for clinical assessment, balance analysis and gait with 180º turning. Spatiotemporal gait parameters during turning were derived using video-based analysis and correlated with modified Hoehn and Yahr (mHY) stages and center of pressure (COP) oscillations.
Results:
A total of 64 PD patients were enrolled. The PD patients with higher mHY stages (≥2.5) had significantly longer turning times, greater numbers of steps, wider step bases and less variability in step length during turns. COP oscillations were positively correlated with the mean turning time on both the anterior-posterior and right-left axes.
Conclusion
Spatiotemporal gait parameter during turning, derived from video-based gait analysis, may represent apromising biomarker for monitoring postural instability in PD patients.
5.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
6.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
7.Shank3 Overexpression Leads to Cardiac Dysfunction in Mice by Disrupting Calcium Homeostasis in Cardiomyocytes
Tae Hee KO ; Yoonhee KIM ; Chunmei JIN ; Byeongil YU ; Minju LEE ; Phuong Kim LUONG ; Tran Nguyet TRINH ; Yeji YANG ; Hyojin KANG ; Yinhua ZHANG ; Ruiying MA ; Kwangmin YOO ; Jungmin CHOI ; Jin Young KIM ; Sun-Hee WOO ; Kihoon HAN ; Jong-Il CHOI
Korean Circulation Journal 2025;55(2):100-117
Background and Objectives:
SH3 and multiple ankyrin repeat domains 3 (Shank3) proteins play crucial roles as neuronal postsynaptic scaffolds. Alongside neuropsychiatric symptoms, individuals with SHANK3 mutations often exhibit symptoms related to dysfunctions in other organs, including the heart. However, detailed insights into the cardiac functions of Shank3 remain limited. This study aimed to characterize the cardiac phenotypes of Shank3-overexpressing transgenic mice and explore the underlying mechanisms.
Methods:
Cardiac histological analysis, electrocardiogram and echocardiogram recordings were conducted on Shank3-overexpressing transgenic mice. Electrophysiological properties, including action potentials and L-type Ca2+ channel (LTCC) currents, were measured in isolated cardiomyocytes. Ca2+ homeostasis was assessed by analyzing cytosolic Ca2+transients and sarcoplasmic reticulum Ca2+ contents. Depolarization-induced cell shortening was examined in cardiomyocytes. Immunoprecipitation followed by mass spectrometrybased identification was employed to identify proteins in the cardiac Shank3 interactome.Western blot and immunocytochemical analyses were conducted to identify changes in protein expression in Shank3-overexpressing transgenic cardiomyocytes.
Results:
The hearts of Shank3-overexpressing transgenic mice displayed reduced weight and increased fibrosis. In vivo, sudden cardiac death, arrhythmia, and contractility impairments were identified. Shank3-overexpressing transgenic cardiomyocytes showed prolonged action potential duration and increased LTCC current density. Cytosolic Ca2+ transients were increased with prolonged decay time, while sarcoplasmic reticulum Ca2+ contents remained normal. Cell shortening was augmented in Shank3-overexpressing transgenic cardiomyocytes. The cardiac Shank3 interactome comprised 78 proteins with various functions. Troponin I levels were down-regulated in Shank3-overexpressing transgenic cardiomyocytes.
Conclusions
This study revealed cardiac dysfunction in Shank3-overexpressing transgenic mice, potentially attributed to changes in Ca2+ homeostasis and contraction, with a notable reduction in troponin I.
8.Sex Differences in Procedural Characteristics and Clinical Outcomes Among Patients Undergoing Bifurcation PCI
Hyun Jin AHN ; Francesco BRUNO ; Jeehoon KANG ; Doyeon HWANG ; Han-Mo YANG ; Jung-Kyu HAN ; Leonardo De LUCA ; Ovidio de FILIPPO ; Alessio MATTESINI ; Kyung Woo PARK ; Alessandra TRUFFA ; Wojciech WANHA ; Young Bin SONG ; Sebastiano GILI ; Woo Jung CHUN ; Gerard HELFT ; Seung-Ho HUR ; Bernardo CORTESE ; Seung Hwan HAN ; Javier ESCANED ; Alaide CHIEFFO ; Ki Hong CHOI ; Guglielmo GALLONE ; Joon-Hyung DOH ; Gaetano De FERRARI ; Soon-Jun HONG ; Giorgio QUADRI ; Chang-Wook NAM ; Hyeon-Cheol GWON ; Hyo-Soo KIM ; Fabrizio D’ASCENZO ; Bon-Kwon KOO
Korean Circulation Journal 2025;55(1):5-16
Background and Objectives:
The risk profiles, procedural characteristics, and clinical outcomes for women undergoing bifurcation percutaneous coronary intervention (PCI) are not well defined compared to those in men.
Methods:
COronary BIfurcation Stenting III (COBIS III) is a multicenter, real-world registry of 2,648 patients with bifurcation lesions treated with second-generation drug-eluting stents.We compared the angiographic and procedural characteristics and clinical outcomes based on sex. The primary outcome was 5-year target lesion failure (TLF), a composite of cardiac death, myocardial infarction, and target lesion revascularization.
Results:
Women (n=635, 24%) were older, had hypertension and diabetes more often, and had smaller main vessel and side branch reference diameters than men. The pre- and post-PCI angiographic percentage diameter stenoses of the main vessel and side branch were comparable between women and men. There were no differences in procedural characteristics between the sexes. Women and men had a similar risk of TLF (6.3% vs. 7.1%, p=0.63) as well as its individual components and sex was not an independent predictor of TLF. This finding was consistent in the left main and 2 stenting subgroups.
Conclusions
In patients undergoing bifurcation PCI, sex was not an independent predictor of adverse outcome.
9.Single port–assisted diverting ileostomy formation for anastomotic leakage after low anterior resection
Kyong-Min KANG ; Heung-Kwon OH ; Hong-min AHN ; Hye-Rim SHIN ; Min-Hyeong JO ; Mi-Jeong CHOI ; Duck-Woo KIM ; Sung-Bum KANG
Journal of Minimally Invasive Surgery 2025;28(1):47-49
Stoma formation for fecal diversion is a common procedure in patients with various complicated conditions after colorectal surgery, such as anastomotic leakage. The singleincision laparoscopic approach for stoma creation offers several advantages, including a reduction in surgical wounds and related complications as well as optimal visualization of the surgical field. This video demonstrates a single-port–assisted diverting ileostomy in a 61-yearold man with anastomotic leakage following low anterior resection for advanced rectal cancer.
10.Spatiotemporal Gait Parameters During Turning and Imbalance in Parkinson’s Disease: Video-Based Analysis From a Single Camera
HoYoung JEON ; Jung Hwan SHIN ; Ri YU ; Min Kyung KANG ; Seungmin LEE ; Seoyeon KIM ; Bora JIN ; Kyung Ah WOO ; Han-Joon KIM ; Beomseok JEON
Journal of Movement Disorders 2025;18(1):87-92
Objective:
This study aims to objectively evaluate turning gait parameters in Parkinson’s disease (PD) patients using 2D-RGB video-based analysis and explore their relationships with imbalance.
Methods:
We prospectively enrolled PD patients for clinical assessment, balance analysis and gait with 180º turning. Spatiotemporal gait parameters during turning were derived using video-based analysis and correlated with modified Hoehn and Yahr (mHY) stages and center of pressure (COP) oscillations.
Results:
A total of 64 PD patients were enrolled. The PD patients with higher mHY stages (≥2.5) had significantly longer turning times, greater numbers of steps, wider step bases and less variability in step length during turns. COP oscillations were positively correlated with the mean turning time on both the anterior-posterior and right-left axes.
Conclusion
Spatiotemporal gait parameter during turning, derived from video-based gait analysis, may represent apromising biomarker for monitoring postural instability in PD patients.

Result Analysis
Print
Save
E-mail