1.Acceptance and commissioning testing of multiparametric imaging using the big bore dual-source CT simulator for radiotherapy
Meijiao WANG ; Yi DU ; Kaining YAO ; Zhongsu FENG ; Jixiang CHEN ; Hao WU ; Kaixuan LI ; Haizhen YUE
Chinese Journal of Radiological Health 2025;34(5):764-769
Objective To evaluate the accuracy of multiparametric imaging on the dual-source CT through acceptance and commissioning testing, and to provide a reference for standardized clinical application. Methods Both the adult and pediatric dual-source CT scanning modes were used to scan the electron density phantom, and identical multiparametric image reconstruction tasks were performed, including the conventional CT images, the mixed CT images, the virtual monoenergetic images, the iodine images, the electron density images, and the effective atomic number images. Results In the adult scanning mode, the virtual monoenergetic CT numbers showed the greatest difference for the cortical bone (
2.Clinical application of split liver transplantation: a single center report of 203 cases
Qing YANG ; Shuhong YI ; Binsheng FU ; Tong ZHANG ; Kaining ZENG ; Xiao FENG ; Jia YAO ; Hui TANG ; Hua LI ; Jian ZHANG ; Yingcai ZHANG ; Huimin YI ; Haijin LYU ; Jianrong LIU ; Gangjian LUO ; Mian GE ; Weifeng YAO ; Fangfei REN ; Jinfeng ZHUO ; Hui LUO ; Liping ZHU ; Jie REN ; Yan LYU ; Kexin WANG ; Wei LIU ; Guihua CHEN ; Yang YANG
Chinese Journal of Surgery 2024;62(4):324-330
Objective:To investigate the safety and therapeutic effect of split liver transplantation (SLT) in clinical application.Methods:This is a retrospective case-series study. The clinical data of 203 consecutive SLT, 79 living donor liver transplantation (LDLT) and 1 298 whole liver transplantation (WLT) performed at the Third Affiliated Hospital of Sun Yat-sen University from July 2014 to July 2023 were retrospectively analyzed. Two hundred and three SLT liver grafts were obtained from 109 donors. One hundred and twenty-seven grafts were generated by in vitro splitting and 76 grafts were generated by in vivo splitting. There were 90 adult recipients and 113 pediatric recipients. According to time, SLT patients were divided into two groups: the early SLT group (40 cases, from July 2014 to December 2017) and the mature SLT technology group (163 cases, from January 2018 to July 2023). The survival of each group was analyzed and the main factors affecting the survival rate of SLT were analyzed. The Kaplan-Meier method and Log-rank test were used for survival analysis.Results:The cumulative survival rates at 1-, 3-, and 5-year were 74.58%, 71.47%, and 71.47% in the early SLT group, and 88.03%, 87.23%, and 87.23% in the mature SLT group, respectively. Survival rates in the mature SLT group were significantly higher than those in the early SLT group ( χ2=5.560, P=0.018). The cumulative survival rates at 1-, 3- and 5-year were 93.41%, 93.41%, 89.95% in the LDLT group and 87.38%, 81.98%, 77.04% in the WLT group, respectively. There was no significant difference among the mature SLT group, the LDLT group and the WLT group ( χ2=4.016, P=0.134). Abdominal hemorrhage, infection, primary liver graft nonfunction,and portal vein thrombosis were the main causes of early postoperative death. Conclusion:SLT can achieve results comparable to those of WLT and LDLT in mature technology liver transplant centers, but it needs to go through a certain time learning curve.
3.Clinical application of split liver transplantation: a single center report of 203 cases
Qing YANG ; Shuhong YI ; Binsheng FU ; Tong ZHANG ; Kaining ZENG ; Xiao FENG ; Jia YAO ; Hui TANG ; Hua LI ; Jian ZHANG ; Yingcai ZHANG ; Huimin YI ; Haijin LYU ; Jianrong LIU ; Gangjian LUO ; Mian GE ; Weifeng YAO ; Fangfei REN ; Jinfeng ZHUO ; Hui LUO ; Liping ZHU ; Jie REN ; Yan LYU ; Kexin WANG ; Wei LIU ; Guihua CHEN ; Yang YANG
Chinese Journal of Surgery 2024;62(4):324-330
Objective:To investigate the safety and therapeutic effect of split liver transplantation (SLT) in clinical application.Methods:This is a retrospective case-series study. The clinical data of 203 consecutive SLT, 79 living donor liver transplantation (LDLT) and 1 298 whole liver transplantation (WLT) performed at the Third Affiliated Hospital of Sun Yat-sen University from July 2014 to July 2023 were retrospectively analyzed. Two hundred and three SLT liver grafts were obtained from 109 donors. One hundred and twenty-seven grafts were generated by in vitro splitting and 76 grafts were generated by in vivo splitting. There were 90 adult recipients and 113 pediatric recipients. According to time, SLT patients were divided into two groups: the early SLT group (40 cases, from July 2014 to December 2017) and the mature SLT technology group (163 cases, from January 2018 to July 2023). The survival of each group was analyzed and the main factors affecting the survival rate of SLT were analyzed. The Kaplan-Meier method and Log-rank test were used for survival analysis.Results:The cumulative survival rates at 1-, 3-, and 5-year were 74.58%, 71.47%, and 71.47% in the early SLT group, and 88.03%, 87.23%, and 87.23% in the mature SLT group, respectively. Survival rates in the mature SLT group were significantly higher than those in the early SLT group ( χ2=5.560, P=0.018). The cumulative survival rates at 1-, 3- and 5-year were 93.41%, 93.41%, 89.95% in the LDLT group and 87.38%, 81.98%, 77.04% in the WLT group, respectively. There was no significant difference among the mature SLT group, the LDLT group and the WLT group ( χ2=4.016, P=0.134). Abdominal hemorrhage, infection, primary liver graft nonfunction,and portal vein thrombosis were the main causes of early postoperative death. Conclusion:SLT can achieve results comparable to those of WLT and LDLT in mature technology liver transplant centers, but it needs to go through a certain time learning curve.
4.Workflow and error analyses of patient setup based on open-face mask immobilization combined with AlignRT for head tumor radiotherapy
Junyu LI ; Hao WU ; Jingxian YANG ; Shun ZHOU ; Zihong LU ; Songmao YU ; Jixiang CHEN ; Meijiao WANG ; Kaining YAO ; Yi DU
Chinese Journal of Radiological Medicine and Protection 2022;42(8):590-597
Objective:To propose a markless patient setup workflow based on the optical surface monitoring system (AlignRT) and open-face mask immobilization for whole-course head tumor radiotherapy, assess the setup time and repositioning frequency of the proposed workflow, and conduct a comparative analysis of the differences, correlation, and consistency of the setup errors of the AlignRT and cone beam CT (CBCT) systems.Methods:A retrospective analysis was conducted for the data on the errors of 132 fractionated setup based on open-face mask immobilization of 33 head tumor patients. AlignRT-guided markless patient setup workflow was applied throughout the radiotherapy. Meanwhile, the body structures automatically generated by the treatment planning system were used as body references. The 6-degree-of-freedom (6DoF) setup errors (lateral, vertical, longitudinal, rotation, pitch, roll, and yaw directions), setup time, and repositioning frequency of the AlignRT and CBCT systems were recorded and analyzed. The Wilcoxon and Spearman analyses were used to statistically assess the differences and correlation of the setup errors of the two systems. Moreover, the Bland-Altman analysis was employed to evaluate the consistency of the two systems.Results:The 6DoF setup errors of CBCT were within the clinical tolerance (linear motions: -0.30 to 0.30 cm; rotational motions: -2.0° to 2.0°). The setup time and repositioning frequency of CBCT were (98 ± 31) s and 1.51% (2/132), respectively. There was no significant difference in setup errors between the two systems except those in x-axis ( Z = -3.11, P= 0.002), y-axis ( Z = -7.40, P<0.001), and Pitch ( Z= -4.48, P<0.001). There was a significant positive correlation between the setup errors along lateral ( rs = 0.47, P<0.001) and vertical ( rs = 0.29, P = 0.001) directions, rotation (Rtn; rs = 0.47, P<0.001), pitch (Pitch; rs = 0.28, P = 0.001) and roll (Roll; rs = 0.45, P<0.001) of the two systems. The 95% limits of agreement (95% LoA) of 6DoF setup errors were -0.12 to 0.09 cm, -0.07 to 0.17 cm, -0.19 to 0.20 cm, -1.0° to 0.9 °, -1.0° to 1.5°, and -0.9° to 1.0°, respectively. The 95% confidence interval (95% CI) of 95% LoA was -0.14 to 0.11 cm, -0.09 to 0.19 cm, -0.23 to 0.23 cm, -1.2° to 1.1°, -1.2° to 1.7°, and-1.0° to 1.1°, respectively, all of which were within the permissible error ranges. The 6DoF setup error difference of 3.41% (27/792< 5%) was beyond the 95% LoA. The maximum absolute differences of 6DoF setup errors within the 95% LoA were 0.12, 0.16, 0.19 cm, 0.9°, 1.5°, and 1.0°, respectively. Conclusions:The proposed markless setup workflow based on AlignRT combined with open-face mask immobilization for whole-course head tumor radiotherapy exhibits reasonable agreement and consistency with the patient setup using CBCT, with acceptable clinical efficiency. It can be applied to the first radiotherapy and the real-time monitoring of therapy to improve the safety and thus is of value in clinical applications.
5.Clinical study of microvascular invasion on prognosis of recipients after liver transplantation for liver cancer
Jianfeng WANG ; Kaining ZENG ; Haibo LI ; Yinan DENG ; Yingcai ZHANG ; Tong ZHANG ; Shuhong YI ; Genshu WANG ; Yang YANG ; Guihua CHEN
Organ Transplantation 2021;12(3):309-
Objective To evaluate the effect of microvascular invasion (MVI) on prognosis of recipients after liver transplantation for primary liver cancer (liver cancer). Methods Clinical data of 177 recipients after liver transplantation for liver cancer were retrospectively analyzed. All patients were divided into the MVI-positive group (
6.The performance of plastic scintillator detector in photon and electron beam
Meijiao WANG ; Kaining YAO ; Sha LI ; Haizhen YUE ; Zhuolun LIU ; Fan JIANG ; Hao WU ; Ruoxi WANG
Chinese Journal of Radiological Medicine and Protection 2021;41(3):205-211
Objective:To investigate the performance of W2 plastic scintillator in megavolt photon and electron beams.Methods:The photon and electron beam energy provided by linear accelerator was used to collect data of the W2 scintillator. The parameters include the electrometer reading stability, W2 dose and dose rate linearity, and angular response. And the dose uncertainty of the W2 correction factors was also investigated.Results:The standard deviation of the electrometer reading stability was between 0.03 and 0.47. The linear regression factors of W2 dose were all 1.0; the maximum deviation of the dose rates was 0.61%. The Cerenkov light radiation correction factor(CLR) for 6 and 10 MV were 0.741 and 0.746, respectively, and the CLR for 6, 9, 12 and 15 MeV were 0.750, 0.753, 0.757 and 0.757, respectively. The maximum deviation of dose uncertainty for 15 MeV was 3.15%.Conclusions:The signal obtained by the blue and green channel was no angular dependence, the same as the high-energy electron beam, which verified that the Cerenkov radiation correction factor has good linearity. W2 plastic scintillator can be applied to non-coplanar radiotherapy dosimetry.
7.Summary of the research frontiers of liver transplantation in 2020 ATC
Haibo LI ; Guoying WANG ; Jianye CAI ; Xiao FENG ; Kaining ZENG ; Yang YANG
Organ Transplantation 2021;12(1):29-
The American Transplant Congress (ATC) is an influential academic congress in the field of organ transplantation. In this article, the hotspots of liver transplantation in 2020 ATC were summarized, including the latest research progress in donor liver procurement and quality assessment, donor liver preservation and ischemia-reperfusion injury (IRI), liver transplantation for hepatocellular carcinoma and other hepatic malignancies, complications after liver transplantation, transplantation immunology, perioperative management and donor-derived infection, pediatric liver transplantation and cell therapy,
8.A feasibility study of the application of structural similarity index to the assessment of radiotherapy plan quality
Qingying WANG ; Jiacheng LIU ; Hanlin WANG ; Kaining YAO ; Jing YOU ; Xiaofan LI ; Ruoxi WANG ; Chaoqiong MA ; Hao WU
Chinese Journal of Radiological Medicine and Protection 2021;41(11):824-829
Objective:To assess the three-dimensional dose distribution in radiotherapy plans using the structural similarity index(SSIM), compare the performance of SSIM with commonly used quality assessment indices, and develop a SSIM-based quality assessment method of multiple prescribed doses.Methods:The SSIM was introduced to providea quality score of various voxels by comparing actual and ideal three-dimensional dose data and combining the spatial location information of the voxels. Then the average value in a region of interest (ROI) was calculated as the quality score of the region. Fifty-three cases of cervical cancer were selected to analyze the correlation of the SSIM with the uniformity index (HI), conformity index (CI) of the dose distribution in various ROIs and to explore the capability of the SSIM to reflect the uniformity and conformity of dose distribution.Two types of quality defects were individually introduced into two of 53 radiotherapy plans. Then the two plans were compared with normal plans to characterize the response of the SSIM.Results:There was no correlation between HI and SSIM in positive lymph nodes(PGTVnd) due to the decrease in the HI sensitivity, while there was a significant negative correlation between them in regions where PGTVnd was removed from the planning target volume(PTV, R=-0.86, P<0.01). Meanwhile, there was a significant positive correlation between CI and SSIM in PGTVnd ( R=0.83, P<0.01). Therefore, the SSIM can be used to identify the artificial design defects in plans by determining abnormal dose gradients. Conclusions:Apart from reducing the defects of previous assessment parameters, the SSIM has the capability to assess the quality of radiotherapy plans by combining the uniformity and conformity of dose distribution and can provide accurate feedback on the spatial locations of quality defects.
9.Relationship between expression level of 15-PGDH and clinical prognosis of liver transplantation for hepatocellular carcinoma
Haibo LI ; Guoying WANG ; Kaining ZENG ; Jianwen ZHANG ; Hui TANG ; Wei LIU ; Yang YANG
Organ Transplantation 2020;11(2):247-
Objective To investigate the relationship between the expression level of 15-hydroxyprostaglandin dehydrogenase (15-PGDH) and clinical prognosis of liver transplantation for hepatocellular carcinoma. Methods The clinical data of 94 recipients undergoing liver transplantation for hepatocellular carcinoma were retrospectively analyzed. The expression of 15-PGDH in the pathological tissues of all recipients was detected by immunohistochemical staining. The relationship between the expression level of 15-PGDH protein and clinical parameters of hepatocellular carcinoma patients was analyzed. The 5-year tumor-free survival and overall survival rates of liver transplant recipients were calculated. The possible independent risk factors of the clinical prognosis of liver transplant recipients were analyzed. Results The expression level of 15-PGDH was significantly correlated with age, Child-Pugh grade and preoperative level of alpha-fetoprotein (AFP) of the recipients (all
10.Complete androgen insensitivity syndrome in identical twins
Wenxia LI ; Huibiao QUAN ; Jingtao DOU ; Kaining CHEN ; Shanshan LI ; Chaoqin CHEN ; Daoliang OU ; Zhen LI ; Mei ZHANG ; Taomei XIE
Chinese Journal of Endocrinology and Metabolism 2020;36(8):707-710
Androgen insensitivity syndrome (AIS) is a recessive single gene disease of X chromosome, which is rare clinically and has a very low incidence in newborn boys. This is mainly due to the abnormal pathway in which androgens play a role, resulting in sexual differentiation disorder in patients. A pair of identical twins were admitted to our hospital, and a new pathogenic mutation site of the androgen receptor gene was found, resulting in an androgen insensitivity phenotype.

Result Analysis