1.Transcatheter edge-to-edge repair strategies for mitral commissural prolapse: a single-center experience
Xinping LIN ; Wangxing HU ; Qifeng ZHU ; Huajun LI ; Jie LIANG ; Huixiang YAN ; Lihan WANG ; Po HU ; Jubo JIANG ; Kaida REN ; Jiaqi FAN ; Yuxin HE ; Xianbao LIU ; Jian'an WANG
Chinese Journal of Cardiology 2025;53(4):356-362
Objective:To investigate the feasibility of transcatheter edge-to-edge repair (TEER) using a short-clip strategy for patients with moderate-to-severe or greater degenerative mitral regurgitation caused by commissural prolapse.Methods:This retrospective study included patients with severe mitral regurgitation secondary to commissural prolapse who underwent TEER at the Second Affiliated Hospital of Zhejiang University School of Medicine between September 2022 and July 2024. Preoperative clinical and imaging data, intraoperative details, procedural outcomes, and 1-month postoperative follow-up results were collected.Results:A total of 19 patients were enrolled, aged (74.1±6.1) years, including 12 males. Among them, 10 patients had external commissural prolapse, and 9 patients had internal commissural prolapse. Preoperatively, all patients exhibited severe mitral regurgitation (4+), with an effective regurgitant orifice area of (0.55±0.17) cm2, left atrial volume of (104.77±36.57) ml, left ventricular end-diastolic volume of (102.29±32.47) ml, left ventricular end-diastolic dimension of (5.34±0.59) mm, and prolapse width of (1.18±0.34) cm. All procedures utilized short clips (NTR or NTW clips) to target the prolapsed commissural region and were completed successfully without intraoperative complications. At 1-month follow-up, no mortality, stroke, single-leaflet device attachment, myocardial infarction, or unplanned mitral reintervention occurred. Mitral regurgitation severity improved to ≤2+ in all patients, with left atrial volume of (74.49±33.83) ml, left ventricular end-diastolic volume of (85.90±18.05) ml, and left ventricular end-diastolic dimension of (4.93±0.37) mm (all P<0.05). Conclusion:The short-clip strategy, focusing on precise clip placement at the commissural interface, is feasible and effective for TEER in patients with severe mitral regurgitation due to commissural prolapse.
2.Transcatheter edge-to-edge repair strategies for mitral commissural prolapse: a single-center experience
Xinping LIN ; Wangxing HU ; Qifeng ZHU ; Huajun LI ; Jie LIANG ; Huixiang YAN ; Lihan WANG ; Po HU ; Jubo JIANG ; Kaida REN ; Jiaqi FAN ; Yuxin HE ; Xianbao LIU ; Jian'an WANG
Chinese Journal of Cardiology 2025;53(4):356-362
Objective:To investigate the feasibility of transcatheter edge-to-edge repair (TEER) using a short-clip strategy for patients with moderate-to-severe or greater degenerative mitral regurgitation caused by commissural prolapse.Methods:This retrospective study included patients with severe mitral regurgitation secondary to commissural prolapse who underwent TEER at the Second Affiliated Hospital of Zhejiang University School of Medicine between September 2022 and July 2024. Preoperative clinical and imaging data, intraoperative details, procedural outcomes, and 1-month postoperative follow-up results were collected.Results:A total of 19 patients were enrolled, aged (74.1±6.1) years, including 12 males. Among them, 10 patients had external commissural prolapse, and 9 patients had internal commissural prolapse. Preoperatively, all patients exhibited severe mitral regurgitation (4+), with an effective regurgitant orifice area of (0.55±0.17) cm2, left atrial volume of (104.77±36.57) ml, left ventricular end-diastolic volume of (102.29±32.47) ml, left ventricular end-diastolic dimension of (5.34±0.59) mm, and prolapse width of (1.18±0.34) cm. All procedures utilized short clips (NTR or NTW clips) to target the prolapsed commissural region and were completed successfully without intraoperative complications. At 1-month follow-up, no mortality, stroke, single-leaflet device attachment, myocardial infarction, or unplanned mitral reintervention occurred. Mitral regurgitation severity improved to ≤2+ in all patients, with left atrial volume of (74.49±33.83) ml, left ventricular end-diastolic volume of (85.90±18.05) ml, and left ventricular end-diastolic dimension of (4.93±0.37) mm (all P<0.05). Conclusion:The short-clip strategy, focusing on precise clip placement at the commissural interface, is feasible and effective for TEER in patients with severe mitral regurgitation due to commissural prolapse.
3.Kidney function change after transcatheter aortic valve replacement in patients with diabetes and/or hypertension.
Jiaqi FAN ; Changjie YU ; Kaida REN ; Wanbing LIN ; Stella NG ; Zexin CHEN ; Xinping LIN ; Lihan WANG ; Qifeng ZHU ; Yuxin HE ; Jubo JIANG ; Xianbao LIU ; Jian'an WANG
Journal of Zhejiang University. Science. B 2021;22(3):241-247
4.Initial clinical experience with transesophageal echocardiography guided NeoChord system for massive regurgitation of posterior mitral valve prolapse
Jie GU ; Zhaoxia PU ; Xianbao LIU ; Kaida REN ; Wei HE ; Minjian KONG ; Jian′an WANG
Chinese Journal of Ultrasonography 2020;29(5):389-393
Objective:To explore the evaluation of transesophageal echocardiography(TEE) in patients with massive regurgitation of posterior mitral valve prolapse undergoing transapical off-pump NeoChord repair.Methods:Eight patients from April to July 2019 in the Second Affilliated Hospital of Zhejiang Univerity with massive regurgitation of posterior mitral valve prolapse underwent NeoChord repair mitral valve morphology, prolapse position and regurgitation degree were evaluated before NeoChord implantation by TEE. Under TEE guidance, the puncture site was identificated, the position and length of artificial chordae were adjusted during implantation. NeoChord′s function and positon after implantation were observed. The complications were monitored during the operation.Results:Mitral valve repair by NeoChord system was successfully performed with implantation of 2 to 4 artificial chordaes in eight patients respectively. Intraoperative TEE and pre-discharge transthoracic echocardiography(TTE) showed moderate MR in two patients, mild to moderate MR in one patient, mild MR in the remaining five patients. Reexaminations with TTE at 1 month after operation showed moderate MR in six patients, and mild to moderate MR in two patients. And no postoperative complications were noted.Conclusions:NeoChord system is a safe, effective and feasible treatment method for patient with mitral valve prolapse, TEE plays an important role during NeoChord implantation.

Result Analysis
Print
Save
E-mail