1.Relationship between coronal angle fluctuation of ankle point and recovery of joint function after ankle fracture
Chinese Journal of Tissue Engineering Research 2025;29(9):1820-1826
BACKGROUND:The morphological indexes of ankle point may change after ankle fracture,and there is a certain correlation between the coronal angle change of ankle point and the functional recovery of ankle joint.Most previous studies have studied the height recovery of ankle point after surgery,so the correlation between the fluctuation of coronal angle of ankle point and the functional recovery of ankle joint after ankle fracture has certain reference significance. OBJECTIVE:To investigate the effect of coronal angle change of ankle point on joint function recovery after ankle fracture. METHODS:A total of 86 patients with ankle fracture who underwent surgical treatment were selected as the study objects,and were divided into excellent group(n=45)and poor group(n=41)according to the results of American Orthopaedic Foot&Ankle Society(AOFAS)hindfoot-ankle score during the last follow-up,and the general data of the two groups were compared.The morphological indexes of ankle points on the affected side and healthy side were compared after surgery based on ankle acupoints and lateral X-rays of the ankle joint,including the width and depth of ankle points,coronal angle and sagittal angle,and the difference of ankle points between the affected side and healthy side,and further comparison and analysis were conducted in each group.A joint model was constructed and Cox regression analysis was used to evaluate the relationship between coronal angle fluctuation and joint function recovery.Least absolute shrinkage and selection operator regression method and multivariate Logistic regression were used to analyze the risk factors affecting the recovery of joint function.The patients were divided into 5-quartile array(Q1-Q5)according to the angle of coronal position at ankle point from low to high.The clinical data characteristics of the five groups were compared,and the correlation between the change of coronal position at ankle point and the risk of poor recovery of joint function was analyzed by multivariate Logistic regression.A restricted cubic spline Logistic regression model was established to analyze the dose-response relationship.The prediction model of regression equation y=1-1/(1+e-z)was established and verified. RESULTS AND CONCLUSION:(1)The width and depth of ankle point on the affected side,coronal angle and sagittal angle were significantly higher than those on the healthy side(all P<0.05),and compared with the excellent group,the difference of ankle point width,depth difference,coronal angle difference and sagittal angle difference were greater in the poor group(P<0.05).(2)The combined model showed that the risk of poor joint function was increased by 3%for every 1? increase in coronal angle,regardless of whether the angle was within the normal range.(3)Least absolute shrinkage and selection operator regression and multivariate Logistics regression analysis showed that after adjusting for potential confounding factors,it was found that age,lack of functional exercise in early stage,no calcaneal traction,failure to remove internal fixation,postoperative complications,and increased ankle coronal angle were independent risk factors for joint function recovery(P<0.05).(4)The coronal angle within 3 months after surgery was independently correlated with the risk of poor joint function recovery(OR=1.57,95%CI:1.38-1.76,P=0.002),and the trend test of the coronal angle from low to high quintile in each postoperative period had statistical significance(Ptrend<0.001).(5)Restricted cubic spline model analysis showed that there was no nonlinear relationship between the coronal angle change of ankle point and the risk of poor joint function recovery in males or females.Through Bootstrap self-sampling,the prediction model has good differentiation and accuracy.(6)The reduction of coronal angle of ankle point after ankle fracture plays a significant role in promoting the recovery of joint function.Therefore,the detection of coronal angle of ankle point after ankle fracture is helpful to understand the recovery of joint function of patients.
2.The Impairment Attention Capture by Topological Change in Children With Autism Spectrum Disorder
Hui-Lin XU ; Huan-Jun XI ; Tao DUAN ; Jing LI ; Dan-Dan LI ; Kai WANG ; Chun-Yan ZHU
Progress in Biochemistry and Biophysics 2025;52(1):223-232
ObjectiveAutism spectrum disorder (ASD) is a neurodevelopmental condition characterized by difficulties with communication and social interaction, restricted and repetitive behaviors. Previous studies have indicated that individuals with ASD exhibit early and lifelong attention deficits, which are closely related to the core symptoms of ASD. Basic visual attention processes may provide a critical foundation for their social communication and interaction abilities. Therefore, this study explores the behavior of children with ASD in capturing attention to changes in topological properties. MethodsOur study recruited twenty-seven ASD children diagnosed by professional clinicians according to DSM-5 and twenty-eight typically developing (TD) age-matched controls. In an attention capture task, we recorded the saccadic behaviors of children with ASD and TD in response to topological change (TC) and non-topological change (nTC) stimuli. Saccadic reaction time (SRT), visual search time (VS), and first fixation dwell time (FFDT) were used as indicators of attentional bias. Pearson correlation tests between the clinical assessment scales and attentional bias were conducted. ResultsThis study found that TD children had significantly faster SRT (P<0.05) and VS (P<0.05) for the TC stimuli compared to the nTC stimuli, while the children with ASD did not exhibit significant differences in either measure (P>0.05). Additionally, ASD children demonstrated significantly less attention towards the TC targets (measured by FFDT), in comparison to TD children (P<0.05). Furthermore, ASD children exhibited a significant negative linear correlation between their attentional bias (measured by VS) and their scores on the compulsive subscale (P<0.05). ConclusionThe results suggest that children with ASD have difficulty shifting their attention to objects with topological changes during change detection. This atypical attention may affect the child’s cognitive and behavioral development, thereby impacting their social communication and interaction. In sum, our findings indicate that difficulties in attentional capture by TC may be a key feature of ASD.
3.Preliminary application of sacral neuromodulation in patients with benign prostatic hyperplasia complicated with underactive bladder after transurethral resection of the prostate
Ning LIU ; Yan ZHANG ; Tao LI ; Qiang HU ; Kai LU ; Lei ZHANG ; Jianping WU ; Shuqiu CHEN ; Bin XU ; Ming CHEN
Journal of Modern Urology 2025;30(1):39-42
[Objective] To evaluate the efficacy and safety of sacral neuromodulation (SNM) in the treatment of patients with benign prostatic hyperplasia (BPH) complicated with underactive bladder (UAB) who respond poorly to transurethral resection of the prostate (TURP). [Methods] A retrospective analysis was performed on 10 patients with BPH and UAB treated with TURP by the same surgeon in Zhongda Hospital Southeast University during Jan.2018 and Jan.2023.The residual urine volume was not significantly relieved after operation, and the maximum urine flow rate and urine volume per discharge were not significantly improved.All patients underwent phase I SNM, and urinary diaries were recorded before and after surgery to observe the average daily frequency of urination, volume per urination, maximum urine flow rate, and residual urine volume. [Results] The operation time was (97.6±11.2) min.During the postoperative test of 2-4 weeks, if the residual urine volume reduction by more than 50% was deemed as effective, SNM was effective in 6 patients (60.0%). Compared with preoperative results, the daily frequency of urination [(20.2±3.8) times vs. (13.2±3.2) times], volume per urination [(119.2±56.7) mL vs. (246.5±59.2) mL], maximum urine flow rate [(8.7±1.5) mL/s vs. (16.5±2.6) mL/s], and residual urine volume [(222.5±55.0) mL vs. (80.8±16.0) mL] were significantly improved, with statistical significance (P<0.05). There were no complications such as bleeding, infection, fever or pain.The 6 patients who had effective outcomes successfully completed phase II surgery, and the fistula was removed.During the follow-up of 1 year, the curative effect was stable, and there were no complications such as electrode displacement, incision infection, or pain in the irritation sites.The residual urine volume of the other 4 unsuccessful patients did not improve significantly, and the electrodes were removed and the vesicostomy tube was retained. [Conclusion] SNM is safe and effective in the treatment of BPH with UAB patients with poor curative effects after TURP.
4.Diagnostic value of exhaled volatile organic compounds in pulmonary cystic fibrosis: A systematic review
Xiaoping YU ; Zhixia SU ; Kai YAN ; Taining SHA ; Yuhang HE ; Yanyan ZHANG ; Yujian TAO ; Hong GUO ; Guangyu LU ; Weijuan GONG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(02):223-229
Objective To explore the diagnostic value of exhaled volatile organic compounds (VOCs) for cystic fibrosis (CF). Methods A systematic search was conducted in PubMed, EMbase, Web of Science, Cochrane Library, CNKI, Wanfang, VIP, and SinoMed databases up to August 7, 2024. Studies that met the inclusion criteria were selected for data extraction and quality assessment. The quality of included studies was assessed by the Newcastle-Ottawa Scale (NOS), and the risk of bias and applicability of included prediction model studies were assessed by the prediction model risk of bias assessment tool (PROBAST). Results A total of 10 studies were included, among which 5 studies only identified specific exhaled VOCs in CF patients, and another 5 developed 7 CF risk prediction models based on the identification of VOCs in CF. The included studies reported a total of 75 exhaled VOCs, most of which belonged to the categories of acylcarnitines, aldehydes, acids, and esters. Most models (n=6, 85.7%) only included exhaled VOCs as predictive factors, and only one model included factors other than VOCs, including forced expiratory flow at 75% of forced vital capacity (FEF75) and modified Medical Research Council scale for the assessment of dyspnea (mMRC). The accuracy of the models ranged from 77% to 100%, and the area under the receiver operating characteristic curve ranged from 0.771 to 0.988. None of the included studies provided information on the calibration of the models. The results of the Prediction Model Risk of Bias Assessment Tool (PROBAST) showed that the overall bias risk of all predictive model studies was high, and the overall applicability was unclear. Conclusion The exhaled VOCs reported in the included studies showed significant heterogeneity, and more research is needed to explore specific compounds for CF. In addition, risk prediction models based on exhaled VOCs have certain value in the diagnosis of CF, but the overall bias risk is relatively high and needs further optimization from aspects such as model construction and validation.
5.Comprehensive evaluation of powder-liquid double-chamber bag products: a systematic review
Fei SHU ; Rui SUN ; Kai SONG ; Yuanlin ZHANG ; Jiaming YAN ; Lixin SHU
Journal of Pharmaceutical Practice and Service 2025;43(2):92-96
Objective To evaluate the advantages of powder-liquid double-chamber bag products compared with traditional powder injection. Methods The systematic review method was used to collect the literature on powder-liquid double-chamber bag, extract common evaluation indicators, evaluate the use value of powder-liquid double-chamber bag products, and conduct a comprehensive comparison with traditional powder injection products. Results A total of 23 articles were included in the literature. The effectiveness indicators used for evaluation were the stability of the liquid medicine, the accuracy of the preparation concentration, and the residual amount of the liquid medicine; the safety indicators were the incidence of insoluble particles and the incidence of punctures and scratches. The economic indicators were preparation cost, occupied volume of preparation supplies, waste weight, hospitalization cost and incidence of blood infection. The applicability indicators were preparation time, average occupation of medical staff, packaging weight and storage and transportation volume, environmental adaptability, and ease of waste disposal. Accessibility indicators are the number of manufacturers, raw material supply capacity, and patient affordability. Through the evaluation of literature evidence, it was found that the stability and concentration accuracy of the powder-liquid double-chamber bag were higher than those of the traditional powder injection, and the domestic supply had been achieved. The double-chamber bag method can reduce the infusion reaction and shorten the preparation time of the liquid medicine. Conclusion Compared with traditional powder injectabler products, powder-liquid double-chamber bags have advantages in the dimensions of effectiveness, safety, economy, suitability and innovation, and the accessibility dimension meets the requirements.
6.Construction of A Single-cell Metabolomics Mass Spectrometry Analysis Platform Enabling Continuous Injection Based on Ultrasound
Wen-Mei ZHANG ; Xiao-Kai GUO ; Tai-Lin XU ; Guang-Sheng GUO ; Xia-Yan WANG
Chinese Journal of Analytical Chemistry 2025;53(3):338-345
Single-cell metabolite analysis at the small molecule level reveals intercellular heterogeneity and molecular diversity,especially living cell metabolite analysis which can provide more accurate biochemical information.In this study,a comprehensive single-cell metabolomics mass spectrometry analysis platform was constructed based on continuous ultrasonic sample introduction,aiming to improve the utilization rate of single cells and the efficiency of mass spectrometry detection.This platform utilized mechanical motion generated by a miniaturized ultrasound module,which minimally affected cell integrity and viability,enabling cell suspension and dispersion for up to 60 min,with cell viability exceeding 70%.By comparing cell suspension densities and the cell number of mass spectrometry detections between static and ultrasound groups,the results showed that the ultrasound treatment significantly reduced cell sedimentation rate and increased single-cell mass spectrometry detection efficiency.Applying this platform to single-cell analysis of cell line of mouse cerebellar astrocytes(C8D1A)and mouse glioma(GL261)cells achieved clustering and differential analysis of different cell types,demonstrating the method's potential in analyzing cellular heterogeneity and identifying cells.This approach promised to provide new insights and solutions for single-cell analysis.
7.Construction and Application of"On-Off-On"Fluorescence Sensor for Chlorpromazine Hydrochloride Based on Near Infrared Carbon Quantum Dots
Yu LIN ; Feng TAN ; Yu-Hua SHEN ; Li-Qin ZHU ; Pei-Yao YAN ; Jin-Tao PAN ; Kai-Shun LIU
Chinese Journal of Analytical Chemistry 2025;53(6):934-943
In this work,near infrared carbon quantum dots(NIR-CDs)were synthesized by hydrothermal method using biomass material Clausena lansium leaves.The synthesized NIR-CDs emitted maximum fluorescence signal at 677 nm,which was independent of excitation wavelength.The characterization results showed that there were abundant groups on the surface of NIR-CDs.Pd2+could form non-fluorescent compounds with the surface groups of NIR-CDs,resulting in fluorescence quenching(Fluorescence signal was denoted as F0).Because chlorpromazine hydrochloride(CPZ)parent nucleus contained unoxidized S atom,CPZ could form stable colored complex with Pd2+under acidic conditions.In the presence of CPZ,Pd2+dissociated from the surface of NIR-CDs and bonded with CPZ,so that the fluorescence signal could be restored(Fluorescence signal was denoted as F).An"on-off-on"fluorescence sensor was thus constructed.The fluorescence signal recovery value of NIR-CDs(△F=F-F0)showed a good linear relationship with the concentration of CPZ in the range of 5.68-28.43 μg/mL,and the detection limit(3σ)was 0.078 μg/mL.The sensor was applied to determination of CPZ in pharmaceutical preparations,and the recoveries were 94%-106%.The developed fluorescence sensor was expected to be used in quality control of actual pharmaceutical preparations.
8.Analysis of Alkylphenols in Water Samples Using High Porous Covalent Organic Frameworks Beads in Combination with Stable Isotope Labelling Technology
Kai-Yue ZHANG ; Cun-Cun SHENG ; Shi-Juan ZHANG ; Yan-Xin LI
Chinese Journal of Analytical Chemistry 2025;53(11):1828-1838
A pair of positively charged stable isotope labelling agents,4-((2,5-dioxocyclopentyloxy)carbonyl)-N,N,N-trimethylnaphthalen-1-aminium iodide(DPTNA)and its deuterated counterpart d3-DPTNA,were designed and synthesized,which were applied to pre-column labelling of alkylphenols to enhance the sensitivity and accuracy of liquid chromatography-tandem mass spectrometry(LC-MS/MS).By crosslinking covalent organic framework(COF)with hydrophilic sodium alginate and Ca2+in the presence of pore forming agent NH4HCO3 and surfactant P123,abundant of"gas pocket"were created before and during the beads formation process,and high porous COF beads with macroporous and open structure were achieved after removal of gas.Compared with traditional powdered adsorbents,COF beads demonstrated superior operability and recyclability.The proposed method was applied to analysis of alkylphenols in water samples with method LODs of 0.25-0.50 ng/L,while the method LOQs were in the range of 0.80-1.52 ng/L,and recoveries ranged from 92.2%to 98.3%.The proposed method could be well applied to the simultaneous enrichment and analysis of alkylphenols in water samples.
9.Network pharmacology, molecular docking, and animal experiments reveal mechanism of Zhizhu Decoction in regulating macrophage polarization to reduce adipose tissue inflammation in obese children.
Yong-Kai YIN ; Chang-Miao NIU ; Li-Ting LIANG ; Mo DAN ; Tian-Qi GAO ; Yan-Hong QIN ; Xiao-Ning YAN
China Journal of Chinese Materia Medica 2025;50(1):228-238
Network pharmacology and molecular docking were employed to predict the mechanism of Zhizhu Decoction in regulating macrophage polarization to reduce adipose tissue inflammation in obese children, and animal experiments were then carried out to validate the prediction results. The active ingredients and targets of Zhizhu Decoction were retrieved from the Traditional Chinese Medicine Systems Pharmacology Database and Analysis Platform(TCMSP). The inflammation related targets in the adipose tissue of obese children were searched against GeneCards, OMIM, and DisGeNET, and a drug-disease-target network was established. STRING was used to construct a protein-protein interaction(PPI) network and screen for core targets. R language was used to carry out Gene Ontology(GO) and Kyoto Encyclopedia of Genes and Genomes(KEGG) pathway enrichment analyses. AutoDock was used for the molecular docking between core targets and active ingredients. 24 SPF grade 6-week C57B/6J male mice were adaptively fed for 1 week, and 8 mice were randomly selected as the blank group. The remaining 16 mice were fed with high-fat diet for 8 weeks to onstruct a high-fat diet induced mouse obesity model. After successful modeling, the 16 mice were randomly divided into model group and Zhizhu Decoction group, with 8 mice in each group. Zhizhu Decoction group was intervened by gavage for 14 days, once a day. Blank group and model group were given an equal amount of sterile double distilled water(ddH_2O) by gavage daily. After the last gavage, serum and inguinal adipose tissue were collected from mice for testing. The morphology of inguinal adipose tissue was observed by hematoxylin-eosin(HE) staining, the levels of inflammatory factors interleukin-6(IL-6) and tumor necrosis factor-α(TNF-α)were detected by enzyme-linked immunosorbent assay(ELISA), and the protein expression of macrophage marker molecule nitric oxide synthase(iNOS) and epidermal growth factor like hormone receptor 1(F4/80) was detected by immunofluorescence staining. Network pharmacology predicted luteolin, naringenin, and nobiletin as the main active ingredients in Zhizhu Decoction and 15 core targets. KEGG pathway enrichment analysis revealed involvement in the key signaling pathway of nuclear factor κB(NF-κB). Molecular docking showed that the active ingredients of Zhizhu Decoction bound well to the core targets. Animal experiment showed that compared with the model group, Zhizhu Decoction reduced the distribution of inflammatory cytokines in the inguinal adipose tissue of mice, lowered the levels of TNF-α and IL-6 in the serum(P<0.05, P<0.01), and down-regulated the expression of iNOS and F4/80(P<0.05). The results showed that the active ingredients in Zhizhu Decoction, such as luteolin, naringenin, and nobiletin, inhibit the aggregation of macrophages in adipose tissue, downregulate their classic activated macrophage(M1) polarization, reduce the expression of inflammatory factors IL-6 and TNF-α, and thus improve adipose tissue inflammation in obese mice.
Animals
;
Drugs, Chinese Herbal/pharmacology*
;
Molecular Docking Simulation
;
Adipose Tissue/immunology*
;
Mice
;
Male
;
Humans
;
Network Pharmacology
;
Macrophages/immunology*
;
Mice, Inbred C57BL
;
Child
;
Protein Interaction Maps/drug effects*
;
Obesity/genetics*
;
Inflammation/drug therapy*
10.Research on software development and smart manufacturing platform incorporating near-infrared spectroscopy for measuring traditional Chinese medicine manufacturing process.
Yan-Fei WU ; Hui XU ; Kai-Yi WANG ; Hui-Min FENG ; Xiao-Yi LIU ; Nan LI ; Zhi-Jian ZHONG ; Ze-Xiu ZHANG ; Zhi-Sheng WU
China Journal of Chinese Materia Medica 2025;50(9):2324-2333
Process analytical technology(PAT) is a key means for digital transformation and upgrading of the traditional Chinese medicine(TCM) manufacturing process, serving as an important guarantee for consistent and controllable TCM product quality. Near-infrared(NIR) spectroscopy has become the core technology for measuring the TCM manufacturing process. By incorporating NIR spectroscopy into PAT and starting from the construction of a smart platform for the TCM manufacturing process, this paper systematically described the development history and innovative application of the combination of NIR spectroscopy with chemometrics in measuring the TCM manufacturing process by the research team over the past two decades. Additionally, it explored the application of a validation method based on accuracy profile(AP) in the practice of NIR spectroscopy. Furthermore, the software development progress driven by NIR spectroscopy supported by modeling technology was analyzed, and the prospect of integrating NIR spectroscopy in smart factory control platforms was exemplified with the construction practices of related platforms. By integrating with the smart platform, NIR spectroscopy could improve production efficiency and guarantee product quality. Finally, the prospect of the smart platform application in measuring the TCM manufacturing process was projected. It is believed that the software development for NIR spectroscopy and the smart manufacturing platform will provide strong technical support for TCM digitalization and industrialization.
Spectroscopy, Near-Infrared/methods*
;
Drugs, Chinese Herbal/analysis*
;
Software
;
Medicine, Chinese Traditional
;
Quality Control

Result Analysis
Print
Save
E-mail