1.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
2.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
3.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
4.Clinical efficacy of "four-step" aortic valve anatomic repair for regurgitant bicuspid aortic valve
Jun LI ; Zheng ZUO ; Hao LAI ; Lili DONG ; Kai ZHU ; Junyu ZHAI ; Yongxin SUN ; Wenjun DING ; Tao HONG ; Chunsheng WANG
Chinese Journal of Thoracic and Cardiovascular Surgery 2025;41(6):334-340
Objective:To explore the clinical efficacy of "four-step" aortic valve anatomic repair for bicuspid aortic valve(BAV) with aortic regurgitation(AR).Methods:From August 2021 to November 2024, a total of 298 consecutive patients with BAV-AR underwent aortic valve anatomic repair(AVr) in Shanghai Zhongshan Hospital Fudan University, 266 males and 32 females, with age of 39(29.5, 48.5) years. All patients underwent " four-step" three-dimensional anatomic repair of the aortic annulus and leaflets, 129(43.3%) patients via upper mini-sternotomy and 169(56.7%) patients via conventional median sternotomy, with the main steps including: (1) deep dissecting and annuloplasty of the virtual basal ring(VBR); (2) symmetrical repairing of leaflets; (3) replacement or remodeling of the sinus of Valsalva; (4) annuloplasty of the sinotubular junction(STJ). Basal and perioperative data were retrospectively collected, and statistical analysis was performed in conjunction with follow-up data.Results:All patients successfully underwent anatomical repair without transferring to valve replacement during operation. Among them, 43 patients underwent aortic root reimplantation technique(Reimplantation group), while 255 patients underwent modified aortic root sleeve remodeling technique(Sleeve group). The median cardiopulmonary bypass time for the Reimplantation and Sleeve groups were 154(134, 169) minutes and 111(95, 129) minutes, respectively( P<0.05); the median aortic cross-clamp time were 112(100, 131) minutes and 80(67, 94) minutes, respectively( P<0.05). Preoperative TEE showed 35 patients(81.4%) and 229 patients(89.8%) with moderate and severe AR in Reimplantation and Sleeve groups, respectively. Postoperative TEE showed 41 patients(95.3%) with no/trace AR and 2 patients(4.7%) with central mild AR in Reimplantation group, while 212 patients(83.1%) with no/trace AR and 43 patients(16.9%) with central mild AR in Sleeve group. Follow-up was completed in all patients, with a median follow-up of 12.9(4.7, 21.2) months. Echocardiography was obtained in 271 patients(90.9%) at the latest follow-up, including no/trace AR in 167 patients(56.0%), mild AR in 89 patients(29.9%), moderate AR in 14 patients(4.7%), and severe AR in 1 patient(0.3%). Conclusion:Aortic valve anatomic repair by standardized "four-step" approach is safe and reproducible. Satisfied short- and mid-term outcome have obtained in selected BAV-AR patients.
5.Clinical efficacy of "four-step" aortic valve anatomic repair for regurgitant bicuspid aortic valve
Jun LI ; Zheng ZUO ; Hao LAI ; Lili DONG ; Kai ZHU ; Junyu ZHAI ; Yongxin SUN ; Wenjun DING ; Tao HONG ; Chunsheng WANG
Chinese Journal of Thoracic and Cardiovascular Surgery 2025;41(6):334-340
Objective:To explore the clinical efficacy of "four-step" aortic valve anatomic repair for bicuspid aortic valve(BAV) with aortic regurgitation(AR).Methods:From August 2021 to November 2024, a total of 298 consecutive patients with BAV-AR underwent aortic valve anatomic repair(AVr) in Shanghai Zhongshan Hospital Fudan University, 266 males and 32 females, with age of 39(29.5, 48.5) years. All patients underwent " four-step" three-dimensional anatomic repair of the aortic annulus and leaflets, 129(43.3%) patients via upper mini-sternotomy and 169(56.7%) patients via conventional median sternotomy, with the main steps including: (1) deep dissecting and annuloplasty of the virtual basal ring(VBR); (2) symmetrical repairing of leaflets; (3) replacement or remodeling of the sinus of Valsalva; (4) annuloplasty of the sinotubular junction(STJ). Basal and perioperative data were retrospectively collected, and statistical analysis was performed in conjunction with follow-up data.Results:All patients successfully underwent anatomical repair without transferring to valve replacement during operation. Among them, 43 patients underwent aortic root reimplantation technique(Reimplantation group), while 255 patients underwent modified aortic root sleeve remodeling technique(Sleeve group). The median cardiopulmonary bypass time for the Reimplantation and Sleeve groups were 154(134, 169) minutes and 111(95, 129) minutes, respectively( P<0.05); the median aortic cross-clamp time were 112(100, 131) minutes and 80(67, 94) minutes, respectively( P<0.05). Preoperative TEE showed 35 patients(81.4%) and 229 patients(89.8%) with moderate and severe AR in Reimplantation and Sleeve groups, respectively. Postoperative TEE showed 41 patients(95.3%) with no/trace AR and 2 patients(4.7%) with central mild AR in Reimplantation group, while 212 patients(83.1%) with no/trace AR and 43 patients(16.9%) with central mild AR in Sleeve group. Follow-up was completed in all patients, with a median follow-up of 12.9(4.7, 21.2) months. Echocardiography was obtained in 271 patients(90.9%) at the latest follow-up, including no/trace AR in 167 patients(56.0%), mild AR in 89 patients(29.9%), moderate AR in 14 patients(4.7%), and severe AR in 1 patient(0.3%). Conclusion:Aortic valve anatomic repair by standardized "four-step" approach is safe and reproducible. Satisfied short- and mid-term outcome have obtained in selected BAV-AR patients.
6.Spatial Heterogeneity and Risk Factors of Dental Caries in 12-Year-Old Children in Shanxi Province,China
Hou RUXIA ; Yang TINGTING ; Liu JIAJIA ; Chen HAO ; Kang WEN ; Li JUNMING ; Shi XIAOTONG ; Liang YI ; Liu JUNYU ; Zhao BIN ; Wang XIANGYU
Biomedical and Environmental Sciences 2024;37(10):1173-1183
Objective This study aimed to explore the spatial heterogeneity and risk factors for dental caries in 12-year-old children in Shanxi province,China. Methods The data encompassed 3,721 participants from the two most recent oral health surveys conducted across 16 districts in Shanxi Province in 2015 and 2018.Eighteen specific variables were analyzed to examine the interplay between socioeconomic factors,medical resources and environmental conditions.The Geo-detector model was employed to assess the impacts and interactions of these ecological factors. Results Socioeconomic factors(Q=0.30,P<0.05)exhibited a more substantial impact compared to environmental(Q=0.19,P<0.05)and medical resource factors(Q=0.25,P<0.05).Notably,the urban population percentage(UPP)demonstrated the most significant explanatory power for the spatial heterogeneity in caries prevalence,as denoted by its highest q-value(q=0.51,P<0.05).Additionally,the spatial distribution's heterogeneity of caries was significantly affected by SO2 concentration(q=0.39,P<0.05)and water fluoride levels(q=0.27,P<0.05)among environmental factors. Conclusion The prevalence of caries exhibited spatial heterogeneity,escalating from North to South in Shanxi Province,China,influenced by socioeconomic factors,medical resources,and environmental conditions to varying extents.
7.Therapeutic results of three-dimensional aortic valve anatomic repair for regurgitant bicuspid aortic valve
Jun LI ; Chunsheng WANG ; Zheng ZUO ; Hao LAI ; Lili DONG ; Kai ZHU ; Junyu ZHAI ; Yongxin SUN ; Wenjun DING ; Tao HONG
Chinese Journal of Surgery 2024;62(11):1024-1031
Objective:To explore the surgical technique and results of three-dimensional aortic valve anatomic repair for bicuspid aortic valve (BAV) with aortic regurgitation (AR).Methods:This is a retrospective case series study. From August 2021 to December 2023, 130 consecutive patients with BAV-AR underwent aortic valve anatomic repair at the Department of Cardiothoracic Surgery, Zhongshan Hospital, Fudan University,and the data were retrospectively analyzed. There were 115 males and 15 females, aged (38.6±11.7) years (range: 15 to 67 years). All patients received modified aortic root reconstruction, to do three-dimensional root remodeling, including the basal ring, sinus of Valsalva and sino-tubular junction simultaneously. Perioperative and follow-up data were collected and analyzed. Comparisons between groups were performed using independent samples t-test, Wilcoxon paired signed-rank test, or χ2 test. Results:No patient transferred to valve replacement during the operation. The cardiopulmonary bypass time ( M(IQR)) was 109(34) minutes (range:67 to 247 minutes), and the aortic cross-clamp time was 76(26) minutes (range: 32 to 158 minutes). Preoperative transesophageal echocardiography showed 123 patients (94.6%) presented with moderate or severe regurgitation. Immediately postoperative transesophageal echocardiography showed no regurgitation in 22 patients (16.9%), trace regurgitation in 81 patients (62.3%) and mild regurgitation in 27 patients (20.8%). Follow up was completed in all patients, with a follow-up of 5.5(9.4) months (range: 0.1 to 27.6 months). No mortality was observed during follow-up. Echocardiography was obtained in 112 patients at the latest follow-up, including no regurgitation in 4 patients (3.6%), trace regurgitation in 58 patients (51.8%), mild regurgitation in 45 patients (40.2%), moderate regurgitation in 4 patients (3.6%), and severe regurgitation in 1 patient (0.9%). Conclusion:For patients with BAV-AR who have good valve quality and no severe aortic sinus dilation, the recent outcomes of three-dimensional anatomical repair technique, focusing on overall remodeling of the aortic root, are satisfactory.
8.Therapeutic results of three-dimensional aortic valve anatomic repair for regurgitant bicuspid aortic valve
Jun LI ; Chunsheng WANG ; Zheng ZUO ; Hao LAI ; Lili DONG ; Kai ZHU ; Junyu ZHAI ; Yongxin SUN ; Wenjun DING ; Tao HONG
Chinese Journal of Surgery 2024;62(11):1024-1031
Objective:To explore the surgical technique and results of three-dimensional aortic valve anatomic repair for bicuspid aortic valve (BAV) with aortic regurgitation (AR).Methods:This is a retrospective case series study. From August 2021 to December 2023, 130 consecutive patients with BAV-AR underwent aortic valve anatomic repair at the Department of Cardiothoracic Surgery, Zhongshan Hospital, Fudan University,and the data were retrospectively analyzed. There were 115 males and 15 females, aged (38.6±11.7) years (range: 15 to 67 years). All patients received modified aortic root reconstruction, to do three-dimensional root remodeling, including the basal ring, sinus of Valsalva and sino-tubular junction simultaneously. Perioperative and follow-up data were collected and analyzed. Comparisons between groups were performed using independent samples t-test, Wilcoxon paired signed-rank test, or χ2 test. Results:No patient transferred to valve replacement during the operation. The cardiopulmonary bypass time ( M(IQR)) was 109(34) minutes (range:67 to 247 minutes), and the aortic cross-clamp time was 76(26) minutes (range: 32 to 158 minutes). Preoperative transesophageal echocardiography showed 123 patients (94.6%) presented with moderate or severe regurgitation. Immediately postoperative transesophageal echocardiography showed no regurgitation in 22 patients (16.9%), trace regurgitation in 81 patients (62.3%) and mild regurgitation in 27 patients (20.8%). Follow up was completed in all patients, with a follow-up of 5.5(9.4) months (range: 0.1 to 27.6 months). No mortality was observed during follow-up. Echocardiography was obtained in 112 patients at the latest follow-up, including no regurgitation in 4 patients (3.6%), trace regurgitation in 58 patients (51.8%), mild regurgitation in 45 patients (40.2%), moderate regurgitation in 4 patients (3.6%), and severe regurgitation in 1 patient (0.9%). Conclusion:For patients with BAV-AR who have good valve quality and no severe aortic sinus dilation, the recent outcomes of three-dimensional anatomical repair technique, focusing on overall remodeling of the aortic root, are satisfactory.
9.The Pathology of Primary Familial Brain Calcification: Implications for Treatment.
Xuan XU ; Hao SUN ; Junyu LUO ; Xuewen CHENG ; Wenqi LV ; Wei LUO ; Wan-Jin CHEN ; Zhi-Qi XIONG ; Jing-Yu LIU
Neuroscience Bulletin 2023;39(4):659-674
Primary familial brain calcification (PFBC) is an inherited neurodegenerative disorder mainly characterized by progressive calcium deposition bilaterally in the brain, accompanied by various symptoms, such as dystonia, ataxia, parkinsonism, dementia, depression, headaches, and epilepsy. Currently, the etiology of PFBC is largely unknown, and no specific prevention or treatment is available. During the past 10 years, six causative genes (SLC20A2, PDGFRB, PDGFB, XPR1, MYORG, and JAM2) have been identified in PFBC. In this review, considering mechanistic studies of these genes at the cellular level and in animals, we summarize the pathogenesis and potential preventive and therapeutic strategies for PFBC patients. Our systematic analysis suggests a classification for PFBC genetic etiology based on several characteristics, provides a summary of the known composition of brain calcification, and identifies some potential therapeutic targets for PFBC.
Animals
;
Brain Diseases/therapy*
;
Xenotropic and Polytropic Retrovirus Receptor
;
Brain/pathology*
10.Mechanisms of PiT2-loop7 Missense Mutations Induced Pi Dyshomeostasis.
Hao SUN ; Xuan XU ; Junyu LUO ; Tingbin MA ; Jiaming CUI ; Mugen LIU ; Bo XIONG ; Shujia ZHU ; Jing-Yu LIU
Neuroscience Bulletin 2023;39(1):57-68
PiT2 is an inorganic phosphate (Pi) transporter whose mutations are linked to primary familial brain calcification (PFBC). PiT2 mainly consists of two ProDom (PD) domains and a large intracellular loop region (loop7). The PD domains are crucial for the Pi transport, but the role of PiT2-loop7 remains unclear. In PFBC patients, mutations in PiT2-loop7 are mainly nonsense or frameshift mutations that probably cause PFBC due to C-PD1131 deletion. To date, six missense mutations have been identified in PiT2-loop7; however, the mechanisms by which these mutations cause PFBC are poorly understood. Here, we found that the p.T390A and p.S434W mutations in PiT2-loop7 decreased the Pi transport activity and cell surface levels of PiT2. Furthermore, we showed that these two mutations attenuated its membrane localization by affecting adenosine monophosphate-activated protein kinase (AMPK)- or protein kinase B (AKT)-mediated PiT2 phosphorylation. In contrast, the p.S121C and p.S601W mutations in the PD domains did not affect PiT2 phosphorylation but rather impaired its substrate-binding abilities. These results suggested that missense mutations in PiT2-loop7 can cause Pi dyshomeostasis by affecting the phosphorylation-regulated cell-surface localization of PiT2. This study helps understand the pathogenesis of PFBC caused by PiT2-loop7 missense mutations and indicates that increasing the phosphorylation levels of PiT2-loop7 could be a promising strategy for developing PFBC therapies.
Humans
;
Cell Membrane
;
Mutation, Missense
;
Phosphates/metabolism*
;
Sodium-Phosphate Cotransporter Proteins, Type III/genetics*

Result Analysis
Print
Save
E-mail