1.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
2.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
3.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
4.Treatment of Diabetic Retinopathy with Blood Stasis, Collateral Obstruction, and Qi and Yin Deficiency Syndrome with Tongluo Mingmu Capsules: A Randomized, Double-blind, and Multi-center Phase Ⅲ Clinical Trial
Junxia REN ; Yongzheng WANG ; Xiaofei LIU ; Li SUN ; Libo YANG ; Lie WU ; Fengmei LIAN ; Qiping WEI ; Lijuan WEI ; Jingsheng YU ; Jianke HAN
Chinese Journal of Experimental Traditional Medical Formulae 2024;30(7):170-178
ObjectiveTo evaluate the clinical efficacy and safety of Tongluo Mingmu capsules in the treatment of diabetic retinopathy with blood stasis, collateral obstruction, and Qi and Yin deficiency syndrome. MethodA randomized, double-blind, positive-control, and multi-center clinical trial design method was used. 416 patients with diabetic retinopathy with blood stasis, collateral obstruction, and Qi and Yin deficiency syndrome in four test centers were included (the ratio of the treatment group to the control group was 3∶1). On the basis of standardized hypoglycemic treatment, the treatment group was given both four Tongluo Mingmu capsules and two Calcium Dobesilate capsule agents three times a day, while the control group were given both two Calcium Dobesilate capsules and four Tongluo Mingmu capsule agents three times a day. The course of treatment was 12 weeks. The curative effect of Tongluo Mingmu capsules was evaluated by comparing the comprehensive curative effect of diabetic retinopathy, traditional Chinese medicine(TCM) syndrome score, corrected visual acuity, fundus changes, fundus fluorescence angiography, and other curative effect indexes before and after treatment in the two groups. At the same time, general examination, laboratory examination, and adverse events were performed to evaluate the safety of the drug. ResultThe baseline demographic data and disease characteristics of the treatment group and the control group were balanced and comparable, with the difference not statistically significant. After 12 weeks of treatment, the total effective rate of the comprehensive curative effect of diabetic retinopathy in the treatment group (61.0%, 189/310) was better than that in the control group (44.1%, 45/102), and the difference was statistically significant (χ2=8.880, P<0.01). The total effective rate of TCM syndromes in the treatment group (88.4%, 259/293) was better than that in the control group (69.9%, 65/93), and the difference was statistically significant (χ2=17.927, P<0.01). The disappearance rate of dry eyes (χ2=8.305), dull complexion (χ2=4.053), lassitude (χ2=10.267), shortness of breath (χ2=8.494), and dry stool (χ2=8.657) in the treatment group was higher than that in the control group, and the difference between the groups was statistically significant (P<0.05, P<0.01). In terms of improving corrected visual acuity (χ2=8.382), fundus changes (χ2=6.026) , the treatment group was significantly better than the control group (P<0.05). During the trial, the incidence of adverse events in the treatment group and the control group was 1.3% and 2.9%, respectively. There was no significant difference between the two groups. In addition, there were no serious adverse events and adverse events leading to withdrawal in both groups. ConclusionTongluo Mingmu capsules can improve the comprehensive curative effect of diabetic retinopathy and enhance the efficacy of TCM syndromes, visual acuity, fundus changes, and fundus fluorescein angiography, with great safety. Therefore, it can provide a new alternative therapeutic drug for patients with diabetic retinopathy.
5.Analysis of driver gene mutations in “Xuanwei” multi-nodular non-small cell lung cancer
WANG Xiaoxionga ; LI Quana ; SHEN Zhenghaib ; CAI Jingjinga ; LI Zhuoyinga ; SHEN Shaoconga ; LI Hongshenga ; LIU Xina ; LIU Xia ; LIU Junxia ; GUO Yinjina ; DU Yaxia ; LAN Yunyia ; MA Luyaoa ; YANG Ruijiaoa ; WU Shunxiana ; ZHOU Yongchuna ; HUANG Yunchaob
Chinese Journal of Cancer Biotherapy 2024;31(4):377-382
[摘 要] 目的:探讨多结节非小细胞肺癌(NSCLC)组织中的驱动基因突变情况与临床病理特征的关系,为多结节NSCLC患者治疗提供分子诊断依据。方法:本研究共纳入2018年1月至2023年10月间云南省肿瘤医院分子诊断中心检测的121例多结节NSCLC患者的253个肺结节肿瘤组织标本,以第二代测序(NGS)技术或扩增阻滞突变系统PCR(ARMS-PCR)技术检测多结节NSCLC 组织中驱动基因突变情况,分析其与患者临床病理特征的关系,比较不同结节间肺癌驱动基因的突变异质性。结果:与非“宣威”NSCLC相比,“宣威”多结节NSCLC患者驱动基因突变具有显著的地域特点,表现在“宣威”患者具有较低(20%)的EGFR敏感突变(L858R、19-del)及较高(27.26%)的EGFR少见突变(主要为G719/S768I、G719);“宣威”多结节NSCLC患者的KRAS突变率(27.27%)亦显著高于非“宣威”患者突变率(12.59%)(P<0.05)。此外,“宣威”多结节NSCLC患者驱动基因突变不一致率高达69.23%,远高于非“宣威”患者驱动基因突变不一致率(55.07%)(P<0.05)。结论:“宣威”多结节NSCLC患者具有较高的EGFR少见突变及KRAS突变率,同一患者不同病灶之间存在更高的驱动基因突变异质性,本研究将为“宣威”多结节NSCLC的诊疗策略提供更多的选择。
6.Study on the influencing factors of unplanned extubation of PICC in 7 298 patients with hematological diseases
Junxia WANG ; Huimin ZHANG ; Miaomiao YANG ; Mengchuan WANG ; Yuwen CHEN ; Li XU
Chongqing Medicine 2024;53(2):239-245
Objective To analyze the influencing factors of unplanned extubation(UE)occurrence of peripherally inserted central catheter(PICC)in the patients with hematological diseases.Methods A retro-spective cohort study method was adopted.The data of 7 298 patients with hematological diseases implanted with PICC catheter and followed up to its removal from January 1,2016 to December 31,2020 in the Hematol-ogy Hospital of Chinese Academy of Medical Sciences were collected,including the demographic information,catheterization records,maintenance and extubation records.According to whether UE occurring,they were divided into the UE group(n=262)and normal extubation group(n=7 036).The general data were com-pared between the two groups.The COX regression was used to analyze the influencing factors of UE in pa-tients with hematological diseases.The dose-effect relationship between age and PICC UE occurrence risk was studied by the restrictive cubic spline method.Results The incidence rate of UE was 3.6%(262/7 298).The COX regression analysis results showed that the gender,disease diagnosis,fibrinogen,prothrombin time,PLT,catheter material,number of punctures during catheterization,positioning method of catheter tip,num-ber of catheter-related complications occurrence were related to PICC UE occurrence in the patients with he-matological diseases(P<0.05).The results of restricted cubic spline showed that there was a"U"-type non-linear relationship between age and UE risk(X2=17.710,P<0.05),and the risk of UE was the lowest when the age was 30 years old.Conclusion In PICC,the emphasis should be paid to the male patients with hemato-logical malignancies who have repeated punctures during catheterization,no intracardiac electrocardiographic positioning during catheterization,bleeding tendency,indwelling polyurethane catheters and repeated catheter-related complications in order to decrease the UC occurrence probability.
7.The feasibility and safety of simultaneous bilateral adrenal vein sampling using 4F-MPA1 catheter via right elbow vein access:preliminary results in 51 patients
Qingan LI ; Qinghe WANG ; Ming YU ; Luhong LI ; Junwei WEN ; Shuangyu SHEN ; Jiali CHU ; Junxia WU ; Yi JIN ; Yuanhao LI
Journal of Interventional Radiology 2024;33(2):176-181
Objective To discuss the feasibility and safety of simultaneous bilateral adrenal vein sampling(AVS)using two 4F-MPA1 catheters via right elbow vein access.Methods A total of 51 consecutive patients with primary aldosteronism,who received simultaneous bilateral AVS using two 4F-MPA1 catheters(one of the two catheters was shaped into pig tail figure)via right elbow vein access at Xiangyang Municipal Central Hospital between October 2021 and October 2022,were enrolled in this study.The used catheter,the success rate of simultaneous bilateral AVS,and the incidence of complications rate were calculated.Results The 4F-MPA1 catheter was used for all of the right AVS,while a specially shaped 4F-MPA1 catheter was used for the main trunk vein AVS of the left adrenal gland and the central vein AVS of the left adrenal gland.The success rate of simultaneous bilateral AVS was 92.2%(47/51).Adrenal hematoma occurred in one patient(1.96%).Conclusion The technique of simultaneous bilateral AVS using two 4F-MPA1 catheters via right elbow vein access is simple to operate,less traumatic,and clinically safe and feasible.However,due to the small sample used in this study,the clinical value of this technique still needs further investigation and verification.
8.Reconstruction of pulp defects of two neighbouring digits with free great toe fibular flaps of both feet: a study on 7 cases
Xin CHEN ; Junxia MEI ; Kun YANG ; Zhenlei SONG ; Yanjuan ZHANG ; Gangqiang LI ; Qiaoqiao YUAN ; Nuo XU
Chinese Journal of Microsurgery 2024;47(1):39-43
Objective:To explore the clinical effect of using great toe fibular flaps of both feet on reconstruction of pulp defects of two neighbouring digits.Methods:A total of 14 digit pulp defects in 7 cases were repaired in Zhoukou Huaihai Hospital using great toe fibular flaps of both feet from August 2020 to January 2023. Of the 7 cases, there were 4 males and 3 females, with an average of 28 years old, ranging from 19 to 45 years old. Meanwhile, there were 4 cases in left hand and 3 cases in right hand. There were 3 cases of digit pulp defects in index and middle fingers, 2 in middle and ring fingers, and 2 in thumb and index fingers. The area of soft tissue defect in 1.2 cm×1.5 cm-3.0 cm×2.5 cm, and flap was 1.5 cm ×1.8 cm-3.2 cm×2.8 cm. Furthermore, 1 case underwent emergency surgery and 5 were repaired in elective surgery. The donor site of the flap was closed directly, and an intermediate-thickness skin graft was prepared from the medial plantar area for transfer in the case of high suture tension at the wound edge. After surgery, patients received postoperative by outpatient clinic and WeChat to observe the appearance, sensation, functional recovery and flap contracture of digits, as well as the movement of the great toes of both feet.Results:After the surgery, all flaps in the 7 cases survived smoothly and the donor sites healed. All patients entered scheduled follow-ups postoperatively for 6 months to 2 years, with an average of 9 months. The flap showed an aesthetic appearance and excellent sensation, with a TPD of 3-6 mm, and satisfactory digit function. The donor site of the great toe fibular flap left linear scars only, without abnormality in range of motion and gait in walking. In addition, there were 5 in excellent and 2 in good according to the Evaluation Trial Standards of Upper Limb Partial Functional of Hand Surgery of Chinese Medical Association.Conclusion:Application of great toe fibular flaps of both feet is an ideal option for the simultaneous repair of pulp defects of two neighbouring digits, which can achieve good reconstructive results.
9.Research progress on safety management of patient handover between operating room and anesthesia recovery room
Junxia XIANG ; Xiaokun LI ; Shaoming DUAN ; Hongwei WANG ; Rong KANG
Chinese Journal of Practical Nursing 2024;40(15):1196-1201
The physiological function of postoperative patients had not returned to normal, coupled with surgical trauma, residual effects of anesthesia and analgesic drugs and potential risk factors, so postoperative patients need to be transferred to the post-anesthesia care unit for observation, until the vital signs were stable before being transferred to the general ward. This paper summarized the importance, safety management status, influencing factors and intervention measures of patient handover between operating room and post-anesthesia care unit, to provide guidance for clinical patient handover and improve the safety of patient handover.
10.On-site rapid detection of multiple pesticide residues in tea leaves by lateral flow immunoassay
Gao JUNXIA ; Zhang TIANYI ; Fang YIHUA ; Zhao YING ; Yang MEI ; Zhao LI ; Li YE ; Huang JUN ; Zhu GUONIAN ; Guo YIRONG
Journal of Pharmaceutical Analysis 2024;14(2):276-283
The application of pesticides(mostly insecticides and fungicides)during the tea-planting process will undoubtedly increase the dietary risk associated with drinking tea.Thus,it is necessary to ascertain whether pesticide residues in tea products exceed the maximum residue limits.However,the complex matrices present in tea samples comprise a major challenge in the analytical detection of pesticide residues.In this study,nine types of lateral flow immunochromatographic strips(LFICSs)were developed to detect the pesticides of interest(fenpropathrin,chlorpyrifos,imidacloprid,thiamethoxam,acet-amiprid,carbendazim,chlorothalonil,pyraclostrobin,and iprodione).To reduce the interference of tea substrates on the assay sensitivity,the pretreatment conditions for tea samples,including the extraction solvent,extraction time,and purification agent,were optimized for the simultaneous detection of these pesticides.The entire testing procedure(including pretreatment and detection)could be completed within 30 min.The detected results of authentic tea samples were confirmed by ultra-performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS),which suggest that the LFICS coupled with sample rapid pretreatment can be used for on-site rapid screening of the target pesticide in tea products prior to their market release.

Result Analysis
Print
Save
E-mail