1.Effect of icariin-containing serum on lipopolysaccharide-induced inflammatory damage in human chondrocytes
Linzhen LI ; Hongzhuo JIAO ; Weinan CHEN ; Mingzhe ZHANG ; Jianlong WANG ; Juntao ZHANG
Chinese Journal of Tissue Engineering Research 2026;30(6):1368-1374
BACKGROUND:Previous studies of the research group have found that icariin-containing serum can delay the progression of knee osteoarthritis,promote chondrocyte proliferation and stem cell cartilage differentiation in rats,but there is still a lack of sufficient basis for clinical application.OBJECTIVE:To investigate the repair effect of icariin-containing serum on lipopolysaccharide-induced inflammatory damage of human chondrocytes.METHODS:The effect of icariin-containing serum on chondrocyte viability was detected by cell counting kit-8 method,and the optimal volume fraction and time of icariin-containing serum were screened.The cells were then divided into blank group,lipopolysaccharide group,icariin-containing serum group and lipopolysaccharide+icariin-containing serum group.After grouping,immunofluorescence was used to detect the secretion of type Ⅱ collagen in chondrocytes in each group.Real-time PCR was used to detect the expression of related genes.RESULTS AND CONCLUSION:(1)Icariin-containing serum showed good biosafety characteristics for human chondrocytes,and the cell viability reached the highest level after 48 hours of intervention when the icariin-containing serum volume fraction was 15%,and the follow-up experiments were carried out according to the conditions.(2)Compared with the blank group,lipopolysaccharide significantly inhibited the expression of type Ⅱ collagen in chondrocytes,while icariin-containing serum showed a positive mobilization effect,which could effectively promote the secretion of type Ⅱ collagen in chondrocytes under normal and inflammatory conditions.(3)The mRNA expression of type Ⅱ collagen and Aggrecan in chondrocytes decreased significantly under lipopolysaccharide stimulation,and the mRNA expression levels of matrix metalloproteinase 13 and a disintegrin-like and metalloproteinase with thrombospondin motifs-5 increased significantly.Icariin-containing serum promoted the mRNA expression of type Ⅱ collagen in human chondrocytes under inflammatory conditions and reduced the mRNA expression of matrix metalloproteinase 13 and a disintegrin-like and metalloproteinase with thrombospondin motifs-5 in chondrocytes after lipopolysaccharide intervention.Therefore,these findings indicate that the icariin-containing serum has good safety for human chondrocytes and plays an important role in maintaining the normal physiological functions of chondrocytes,promoting the synthesis of extracellular matrix,and inhibiting the secretion of inflammatory factors.
2.Effect of icariin-containing serum on lipopolysaccharide-induced inflammatory damage in human chondrocytes
Linzhen LI ; Hongzhuo JIAO ; Weinan CHEN ; Mingzhe ZHANG ; Jianlong WANG ; Juntao ZHANG
Chinese Journal of Tissue Engineering Research 2026;30(6):1368-1374
BACKGROUND:Previous studies of the research group have found that icariin-containing serum can delay the progression of knee osteoarthritis,promote chondrocyte proliferation and stem cell cartilage differentiation in rats,but there is still a lack of sufficient basis for clinical application.OBJECTIVE:To investigate the repair effect of icariin-containing serum on lipopolysaccharide-induced inflammatory damage of human chondrocytes.METHODS:The effect of icariin-containing serum on chondrocyte viability was detected by cell counting kit-8 method,and the optimal volume fraction and time of icariin-containing serum were screened.The cells were then divided into blank group,lipopolysaccharide group,icariin-containing serum group and lipopolysaccharide+icariin-containing serum group.After grouping,immunofluorescence was used to detect the secretion of type Ⅱ collagen in chondrocytes in each group.Real-time PCR was used to detect the expression of related genes.RESULTS AND CONCLUSION:(1)Icariin-containing serum showed good biosafety characteristics for human chondrocytes,and the cell viability reached the highest level after 48 hours of intervention when the icariin-containing serum volume fraction was 15%,and the follow-up experiments were carried out according to the conditions.(2)Compared with the blank group,lipopolysaccharide significantly inhibited the expression of type Ⅱ collagen in chondrocytes,while icariin-containing serum showed a positive mobilization effect,which could effectively promote the secretion of type Ⅱ collagen in chondrocytes under normal and inflammatory conditions.(3)The mRNA expression of type Ⅱ collagen and Aggrecan in chondrocytes decreased significantly under lipopolysaccharide stimulation,and the mRNA expression levels of matrix metalloproteinase 13 and a disintegrin-like and metalloproteinase with thrombospondin motifs-5 increased significantly.Icariin-containing serum promoted the mRNA expression of type Ⅱ collagen in human chondrocytes under inflammatory conditions and reduced the mRNA expression of matrix metalloproteinase 13 and a disintegrin-like and metalloproteinase with thrombospondin motifs-5 in chondrocytes after lipopolysaccharide intervention.Therefore,these findings indicate that the icariin-containing serum has good safety for human chondrocytes and plays an important role in maintaining the normal physiological functions of chondrocytes,promoting the synthesis of extracellular matrix,and inhibiting the secretion of inflammatory factors.
3.Clinical Study on Acupoint Automatic Positioning Moxibustion Therapy Robot for Treatment of Lumbar Disc Herniation
Shuangyue LI ; Juntao YAN ; Fanfu FANG ; Yuxin ZHENG ; Chengbing CAO ; Yuan YUAN ; Feiran ZHAO ; Qing XU ; Xiaojie SU ; Guohui ZHANG
Chinese Journal of Information on Traditional Chinese Medicine 2025;32(5):154-161
Objective To investigate the clinical advantages and safety of an acupoint auto-positioning moxibustion robot combined with massage techniques in the treatment of lumbar disc herniation.Methods Totally 114 patients with lumbar disc herniation treated between June 2021 and December 2023 at Yueyang Hospital of Integrated Traditional Chinese and Western Medicine,Shanghai University of Traditional Chinese Medicine,the Outpatient Department of Rehabilitation Medicine,Changhai Hospital and Shanghai Third Rehabilitation Hospital were divided into control group and experimental group with random number table method,with 57 cases in each group.The control group received conventional moxibustion combined with massage techniques,while the experimental group was treated using an acupoint auto-positioning moxibustion robot combined with massage techniques.Both groups underwent treatment once every three days,totaling 10 sessions over one month.Clinical efficacy was observed between the two groups by comparing pre-treatment and post-treatment(after 3,6 and 10 sessions)scores on the visual analogue scale(VAS)for pain,the Japanese Orthopaedic Association(JOA)lower back pain score,and lumbar range of motion(LROM).Adverse reactions during the intervention were recorded.Satisfaction with the moxibustion robot in the experimental group was assessed using a Likert scale.Additionally,20 healthy subjects were recruited to evaluate the accuracy of the robot's acupoint auto-positioning function.Results The overall effective rate was 91.23%(52/57)in the experimental group and 94.74%(54/57)in the control group,without statistical significance between the two groups(P>0.05).Compared to pre-treatment,both groups showed significant improvements in VAS scores,JOA scores and LROM across all measured directions after 3,6,and 10 treatment sessions(P<0.001).In the Likert scale assessment,86.96%of subjects agreed that the device was convenient to use,87.72%agreed that the device was safer than conventional moxibustion therapy,and 94.74%were willing to recommend the device to other patients.The accuracy evaluation of the acupoint auto-positioning moxibustion robot demonstrated that the average deviation between robot-positioned acupoints and standard acupoints was(1.68±0.46)mm,achieving a positioning accuracy rate exceeding 95%.No adverse reactions were reported during the intervention.Conclusion The combination of an acupoint auto-positioning moxibustion robot with massage techniques is as effective as conventional moxibustion combined with massage techniques in improving clinical symptoms,alleviating pains,enhancing lumbar function and increasing lumbar mobility in patients with lumbar disc herniation.Participants have exhibited a high willingness to use the device,and the robot achieved a high accuracy rate in acupoint positioning.
4.Combining proprioceptive training with core stability training improves the balance and lower limb motor functioning of burns patients
Haiyang ZHAO ; Juntao HAN ; Jiaqi LIU ; Dahai HU ; Qin ZHOU ; Chan ZHU ; Jin XU ; Bowen ZHANG ; Zongshi QI
Chinese Journal of Physical Medicine and Rehabilitation 2025;47(5):425-429
Objective:To observe any influence of combining proprioceptive training with core stability training in rehabilitation motor functioning and balance after extensive burns.Methods:Sixty patients with lower limb motor and balance disorders after extensive burns were randomly divided into a treatment group and a control group, each of 30. Both groups underwent skin grafting on the lower limbs. After the wounds had healed, both groups were given routine rehabilitation treatment, including joint stretching and muscle strength training, but the treatment group was additionally provided with proprioception and core stability training. Before and after 12 weeks of treatment, both groups′ lower limb motor function and walking ability were evaluated using the Fugl-Meyer Assessment (L-FMA), and static and dynamic balance were quantified using Holden Functional Ambulation Classification (FAC). The duration of standing on one leg with the eyes closed was recorded, along with Timed " Up & Go" Test (TUGT) times. After the treatment, each patient′s satisfaction was assessed using a self-designed questionnaire.Results:Significant improvement was observed in the average L- FMA and FAC scores after the treatment, as well as in the ability to stand on one leg with the eyes closed. The average TUGT time in both groups was shorter, but there had been significantly greater improvement of the treatment group than among the controls. Reported satisfaction was significantly higher among the treated group than among the controls.Conclusions:Supplementing basic rehabilitation with proprioception training and core stability training can further improve the motor functioning, balance and walking of persons who have suffered extensive burns.
5.Relationship between the Expression of METTL16,ASB13 in Elderly Breast Cancer Tissues and Clinicopathological Features and Prognosis
Jinbiao ZHANG ; Yan ZHANG ; Juntao SONG ; Xinye LIU ; Dong NIE ; Tianwei ZHANG
Journal of Modern Laboratory Medicine 2025;40(4):131-136,142
Objective To study the expression of N6-methyladenosine(m6A)methyltransferase-like protein 16(METTL16),Ankyrin repeat and SOCS box containing protein 4(ASB13)in elderly breast cancer tissues and their relationship with clinicopathological features and prognosis.Methods 124 elderly patients with breast cancer diagnosed and treated in the Zibo 148 Hospital from January 2019 to January 2021 were selected.Immunohistochemistry(IHC)was used to detect the expression of METTL16 and ASB13 proteins in tissues.Real time fluorescence quantitative PCR(RT-qPCR)was used to detect the expression of METTL16 mRNA and ASB13 mRNA in tissues.Pearson correlation was used for correlation analysis.Survival analysis used Kaplan-Meier curves and Log Rank tests to compare the prognostic differences among patients with different METTL16 and ASB13 expression levels.COX regression analysis was used to analyze the prognostic factors of elderly patients with breast cancer.Results The positive rate of METTL16 in cancer tissue(70.97%)was higher than that in adjacent tissues(8.06%),while the positive rate of ASB13(22.58%)was lower than that in adjacent tissues(72.58%),the differences were statistically significant(χ2=102.642,62.146,all P<0.001).METTL16 mRNA,Snail mRNA and N-cadherin(N-cd)mRNA were higher in cancer tissues than in adjacent tissues,while ASB13 mRNA was lower in adjacent tissues,the differences were statistically significant(t=40.498~48.624,all P<0.001).METTL16 mRNA was positively correlated with Snail mRNA and N-cd mRNA in cancer tissue(r=0.712,0.669,all P<0.001),while ASB13 mRNA was negatively correlated with Snail mRNA and N-cd mRNA(r=-0.734,-0.759,all P<0.001).Compared with TNM stage Ⅰ-Ⅱ and patients with high to medium differentiation,patients with TNM stage Ⅲ and low differentiation had higher positive rate of METTL16 in cancer tissue and lower positive rate of ASB13,the differences were statistically significant(χ2=5.340~10.370,all P<0.05).The 3-year progression free survival rate(73.86%)of the METTL16 positive group was lower than that of the METTL16 negative group(88.89%),the 3-year progression free survival rate(92.86%)of the ASB13 positive group was higher than that of the ASB13 negative group(73.96%),and the differences were statistically significant(Log Rank χ2=4.483,4.882,all P<0.005).METTL16 positive,TNM stage Ⅲ,poor differentiation were risk factors affecting the prognosis of elderly breast cancer,and ASB13 positive was protective factors(Wald χ2=5.056~9.267,all P<0.001).Conclusion METTL16 expression is up-regulated and ASB13 expression is down-regulated in elderly breast cancer,both of which are related to the expression of invasion and metastasis genes,and are new prognostic markers for elderly breast cancer.
6.Clinical application of improved treatment of the free margin of the leaflet in aortic root remodeling procedure
Xinjin LUO ; Shaoye WANG ; Juntao QIU ; Xuanshu LI ; Peng ZHANG ; Yuetang WANG ; Cuntao YU
Chinese Journal of Surgery 2025;63(7):618-623
Objective:To investigate the feasibility and clinical outcome of estimating the target length of the free margin of the leaflet by diameter of the prosthesis graft used to reconstruct the aortic root during the modified root remodeling procedure.Methods:This is a retrospective case series study. The clinical data of 11 patients with aortic root aneurysm who underwent modified aortic root remodeling procedure with external sub-valvular ring from July 2021 to May 2024 at Department of Cardiovascular Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College were analyzed. The age of the patients was (42.3±14.4) years (range:23 to 61 years), including 9 males and 2 females. The aortic valve of all patients was tri-leaflet configuration. Marfan syndrome was diagnosed in 3 cases. The diameter of the prosthesis graft was determined according to the Lansac group′s criteria based on the diameter of the aortic annulus, and a graft ring of the same diameter was used as the external sub-valvular ring. The free margin of the leaflet was treated with central plication according to the standard of “target length of free margin of the leaflet=the diameter of the selected graft+3 to 5 mm”. The surgical results and postoperative aortic valve closure function were observed.Results:All 11 patients successfully completed the operation without in-hospital death or complications. The graft with a diameter of 28 mm were used in 7 cases, 26 mm in 3 cases, and 30 mm in 1 case. 4 patients required central plication of the free margin of 3 leaflets, 2 patients required treatment of 2 leaflets, 3 patients required treatment of 1 leaflet, and 2 patients did not need treatment of the free margin of the leaflets. The functional status of aortic valve closure was significantly improved in all patients after surgery, and the degree of residual aortic regurgitation was not more than mild. After reconstruction of the aortic root, the measured effective height was (8.8±1.3) mm (range:7 to 11 mm) and the measured coaptation length was (5.2±0.9) mm (range:4 to 7 mm). All patients were re-examined 3 months after surgery. Echocardiography showed that the degree of aortic regurgitation was mild or lower, and the left ventricular end-diastolic diameter was (49.4±6.1) mm (range: 36 to 56 mm), which was smaller than that before the operation ((58.5±7.0) mm (range: 47 to 72 mm)). Eight patients were followed up for more than 6 months, and 5 patients were followed up for more than 1 year. The degree of aortic regurgitation in these patients was mild or below.Conclusions:The method based on the diameter of the selected prosthesis graft to deal with the length of the free margin of the leaflet can be effectively used in the modified aortic root remodeling procedure with external sub-valvular ring. The early postoperative results are satisfactory .
7.Monitoring results of mosquito-ovitraps placed in different orientations in multi-storey residential areas
Caixiong LIU ; Bin GE ; Haibing ZHANG ; Lin WANG ; Tao YANG ; Yujiao WEI ; Haiying XIE ; Yu ZHANG ; Hongxia LIU ; Juntao SHEN
Shanghai Journal of Preventive Medicine 2025;37(2):109-113
ObjectiveTo find out whether there is any difference in the monitoring results of mosq-ovitraps placed in different orientations in multi-storey residential areas, so as to provide a scientific basis for routine and emergency monitoring of Aedes albopictus with mosq-ovitraps in residential areas. MethodsFrom July 6th to October 26th 2023, one mosquito ovitrap was set up in each of the 4 orientations of east, south, west and north around the buildings in a multi-storey residential area in Jinhui Town, Fengxian District, Shanghai. Data was collected and recorded 72 hours after placement. The chi-square test was used to compare the mosquito ovitrap indices (MOIs) of two independent samples, and the Kruskal⁃Wallis H test was used to compare the MOIs of multiple independent samples. ResultsAfter 16 weeks of surveillance, 997 mosquito ovitraps were recovered, of which 211 were positive, with the mosquito ovitrap index (MOI) of 21.16% and the Aedes albopictus density index of 1.03 mosquitoes·ovitrap-1. The MOIs were higher in September (24.22%) and October (23.96%), and the MOIs in the west, south and north within the two months were all above 20.00%. From July to October, the MOIs in the east, west, south and north were 20.70%, 22.20%, 25.50% and 16.20%, respectively, and the difference in MOIs among the 4 orientations was not statistically significant (χ2=6.647, P=0.084). Stratified analysis by month showed that in August, the south side of the multi-storey residential areas had the highest MOI (31.30%), the north side had the lowest MOI (1.30%), and there was a statistically significant difference in MOI in the east, west, south and north (χ2=25.986, P<0.001). In October, the MOI in the west was the highest (33.30%) and the MOI in the east was the lowest (6.30%), the difference in MOIs of the 4 orientations was statistically significant (χ2=12.007, P=0.007). The MOIs in the south side of the building in the outskirts of the residential area from the 1st week in July to the 4th week in October was lower (19.20%) than that in the south side of the inner building (31.70%), and the difference in MOI was statistically significant (χ2=5.118, P=0.024). ConclusionThe study of MOI in different orientations in a multi-storey residential area is a preliminary exploration based on field work, and the results show that there is a difference in MOIs in different orientations during the peak breeding period of mosquitoes. Further indicators such as temperature, humidity and wind speed in different orientations can be collected to explore the influencing factors of MOIs.
8.Icariin-containing serum promotes chondrocyte proliferation and chondrogenic differentiation of stem cells in the co-culture system of three kinds of cells
Qi LIU ; Linzhen LI ; Yusheng LI ; Hongzhuo JIAO ; Cheng YANG ; Juntao ZHANG
Chinese Journal of Tissue Engineering Research 2025;29(7):1371-1379
BACKGROUND:The capability of repairing articular cartilage damage is very limited,and tissue engineering technology provides new therapeutic options for repairing damaged cartilage,in which the interaction and induction between chondrocytes,bone marrow mesenchymal stem cells,and synovial mesenchymal stem cells is the basis of autologous healing of cartilage damage. OBJECTIVE:To construct the chondrocyte-bone marrow mesenchymal stem cell-synovial mesenchymal stem cell co-culture system to simulate the in vitro microenvironment of chondrocytes,and to explore the optimal cell inoculation ratio,meanwhile to observe the effects of icariin-containing serum on the proliferation of chondrocytes and the chondrogenic differentiation of stem cells in the system. METHODS:Rat knee chondrocytes,bone marrow mesenchymal stem cells and synovial mesenchymal stem cells were extracted,cultured and identified,and a chondrocyte-bone marrow mesenchymal stem cell-synovial mesenchymal stem cell non-contact co-culture system was constructed according to different cell inoculation ratios.After 72 hours of co-culturing,the chondrocyte proliferative activity and phenotypic ability were observed,and the co-culture system with the best overall effect was selected.New Zealand white rabbits were gavaged with icariin solution(0.25 mg/mL)to prepare icariin-containing serum,and cultured in conventional complete medium(high sugar DMEM culture medium containing 10%fetal bovine serum and 1%double antibody by volume)as the control group,while the experimental group was intervened by adding 10%icariin-containing serum by volume on the basis of above.The proliferative activity of chondrocytes and the expression of collagen type II were tested for the two groups after 24 and 48 hours.The differentiation of bone marrow mesenchymal stem cells and synovial mesenchymal stem cells into chondrocytes in the co-culture system was tested by immunofluorescence staining after 14 days. RESULTS AND CONCLUSION:(1)The three kinds of cells grew normally adherently to the wall in different ratios of co-culture,where chondrocytes showed the best proliferative activity and phenotypic ability in the co-culture system when chondrocytes:bone marrow mesenchymal stem cells:synovial mesenchymal stem cells=2:1:1.(2)Compared with the control group,the proliferative activity and type II collagen expression of chondrocytes in the experimental group were significantly increased after 24 hours(P<0.01),and the two groups still had difference after 48 hours(P<0.05).The two groups showed obvious chondrogenic differentiation of bone marrow mesenchymal stem cells and synovial mesenchymal stem cells after 14 days(P<0.01),and some of the cells appeared round or oval,and the cytoplasmic type II collagen immunofluorescence staining was positive.The fluorescence intensity of the experimental group was significantly higher than that of the control group(P<0.01).(3)The results showed that the chondrocyte-bone marrow mesenchymal stem cell-synovial mesenchymal stem cell co-culture system could be successfully established by the non-contact co-culture method,and the best chondrocyte proliferative activity and phenotypic ability could be obtained when the cell ratio was 2:1:1.Icariin-containing serum had the promoting effect on chondrocyte proliferation,and chondrogenic differentiation of bone marrow mesenchymal stem cells and synovial mesenchymal stem cells in the system.
9.Predictive Value of a Multidimensional Neonatal Nutritional Risk Screening Scale for Extrauterine Growth Restriction in Premature Infants
Yumei WU ; Juntao ZHANG ; Yinghong DENG ; Yuqi LI ; Huan FENG ; Jie WU
Journal of Kunming Medical University 2025;46(3):72-78
Objective To apply a multidimensional neonatal nutritional risk screening scale for hospitalized premature infants to explore its predictive value for extrauterine growth restriction(EUGR)at the time of discharge.Methods A total of 104 premature infants hospitalized in the Neonatal Department of the Second Affiliated Hospital of Kunming Medical University from January 2023 to September 2023 were selected as research subjects.Nutritional risk screening was conducted within 24 hours of admission and weekly thereafter using the multidimensional neonatal nutritional risk screening scale.Scoring was based on four dimensions(birth status,weight changes,nutritional intake methods,and disease diagnosis),with a total score of ≥ 8 indicating high risk;≥4 and<8 indicating moderate risk;and<4 indicating low risk.EUGR at the time of discharge was the primary clinical outcome indicator.Receiver operating characteristic(ROC)curves were constructed to explore the predictive value of neonatal nutritional risk screening for EUGR in premature infants.Results At discharge,40 premature infants(38.5%)experienced EUGR.The nutritional risk screening scores of the EUGR group on day 7 of hospitalization were higher than those of the non-EUGR group(P<0.05).The rate of high nutritional risk on day 7 of hospitalization was highest(7.9%in the non-EUGR group,22%in the EUGR group,and 13.5%overall).On both day 1 and day 7 of hospitalization,the rate of high nutritional risk in the EUGR group was higher than that in the non-EUGR group(P<0.05).There were significant differences in the nutritional risk screening scores on day 7,birth weight Z-scores,discharge corrected gestational age weight Z-scores,and serum albumin levels between the EUGR and non-EUGR groups(P<0.05).ROC curves were plotted,yielding AUCs of 0.625(95%CI 0.514,0.736),0.652(95%CI 0.544,0.760),0.674(95%CI 0.561,0.786),and 0.641(95%CI 0.531,0.750),indicating certain predictive value.A combined predictive ROC model yielded an AUC of 0.786(95%CI 0.692,0.880)for EUGR,which was higher than the AUCs for individual indicators(P<0.001).Conclusion The occurrence of EUGR is relatively common among hospitalized premature infants.The nutritional risk is highest during the first week of hospitalization.The multidimensional neonatal nutritional risk screening scale can dynamically assess nutritional risk during hospitalization and may serve as one of the early warning indicators for EUGR in premature infants.The predictive efficacy for EUGR is enhanced when combined with birth weight Z-scores,discharge weight Z-scores,and serum albumin,providing a basis for individualized nutritional management of premature infants.
10.Efficacy and safety of acupoint application for gastrointestinal function in treating post-stroke depression: Protocol for a randomized controlled trial
Xuan Zhang ; Shuhui Li ; Juntao Wang ; Chung Tai Lau ; Jacky C.P. Chan
Journal of Traditional Chinese Medical Sciences 2025;2025(4):552-558
ObjectiveTo evaluate the efficacy and safety of acupoint application for post-stroke depression (PSD) by regulating gastrointestinal function. A secondary objective is to explore the potential mechanism underlying this approach from the perspective of gut microbiota.MethodsThis multicenter, randomized, double-blind (patients and assessors), placebo-controlled trial will enroll 80 patients with PSD, and include a 1-week run-in period, a 4-week treatment phase, and a 12-week follow-up. Eligible participants will randomly be assigned in a 1:1 ratio to either the acupoint application or placebo (non-acupoint) groups. Treatments will be administered thrice weekly for 4 weeks. The primary outcome is change in the Hamilton Rating Scale for Depression (HAMD) score. Secondary outcomes include the Beck Depression Inventory (BDI), 36-Item Short-Form Health Survey (SF-36), Barthel Index of Activities of Daily Living, Social Adaptation Self–Evaluation Scale (SASS), and gut microbiota profiling. All outcomes will be assessed at baseline (prior to treatment), during treatment (weeks 2 and 4), and during follow-up (weeks 8, 12, and 16). The Treatment Emergent Symptom Scale (TESS) will be used for evaluation throughout the 4-week treatment phase.DiscussionThe results of this study will provide important evidence supporting a novel treatment strategy for PSD that targets gastrointestinal regulation, potentially informing future clinical practice.


Result Analysis
Print
Save
E-mail