1.Combining proprioceptive training with core stability training improves the balance and lower limb motor functioning of burns patients
Haiyang ZHAO ; Juntao HAN ; Jiaqi LIU ; Dahai HU ; Qin ZHOU ; Chan ZHU ; Jin XU ; Bowen ZHANG ; Zongshi QI
Chinese Journal of Physical Medicine and Rehabilitation 2025;47(5):425-429
Objective:To observe any influence of combining proprioceptive training with core stability training in rehabilitation motor functioning and balance after extensive burns.Methods:Sixty patients with lower limb motor and balance disorders after extensive burns were randomly divided into a treatment group and a control group, each of 30. Both groups underwent skin grafting on the lower limbs. After the wounds had healed, both groups were given routine rehabilitation treatment, including joint stretching and muscle strength training, but the treatment group was additionally provided with proprioception and core stability training. Before and after 12 weeks of treatment, both groups′ lower limb motor function and walking ability were evaluated using the Fugl-Meyer Assessment (L-FMA), and static and dynamic balance were quantified using Holden Functional Ambulation Classification (FAC). The duration of standing on one leg with the eyes closed was recorded, along with Timed " Up & Go" Test (TUGT) times. After the treatment, each patient′s satisfaction was assessed using a self-designed questionnaire.Results:Significant improvement was observed in the average L- FMA and FAC scores after the treatment, as well as in the ability to stand on one leg with the eyes closed. The average TUGT time in both groups was shorter, but there had been significantly greater improvement of the treatment group than among the controls. Reported satisfaction was significantly higher among the treated group than among the controls.Conclusions:Supplementing basic rehabilitation with proprioception training and core stability training can further improve the motor functioning, balance and walking of persons who have suffered extensive burns.
2.Development of a miniaturized CRISPR/Cas gene editing tool for human gut Bacteroides.
Yiwen ZHAN ; Linggang ZHENG ; Juntao SHEN ; Yucan HU ; Xuegang LUO ; Lei DAI
Chinese Journal of Biotechnology 2025;41(6):2360-2372
: Bacteroides, as one of the most abundant and diverse genera in the human gut, is regarded as a window into the study of gut microbiota-host interactions. Currently, CRISPR/Cas-based gene editing systems targeting Bacteroides have been widely applied, while the large size of Cas nucleases limits their potential application scenarios (such as in situ gut Bacteroides editing based on phage delivery). Therefore, this study aims to develop a compact and highly efficient genetic editing tool in Bacteroides., We developed a miniaturized CRISPR/Cas gene editing system for human gut Bacteroides. First, the editing capabilities of different miniaturized CRISPR/Cas systems, including AsCas12f, CasΦ2, and ISDge10, were evaluated in Bacteroides fragilis. Subsequently, the editing capability of AsCas12f was assessed across various Bacteroides species, and the size of this system was further optimized. The results demonstrated that the CRISPR/AsCas12f genome editing system exhibited the highest editing efficiency in B. fragilis. The CRISPR/AsCas12f system achieved efficient genome editing in B. fragilis, Bacteroides thetaiotaomicron, and Phocaeicola vulgatus. Furthermore, with a repair template of 500 bp homologous arms, the editing efficiency remained as high as 94.7%. In conclusion, CRISPR/AsCas12f can serve as a chassis tool enzyme for the development of Bacteroides-based miniature gene editors and derivative technologies, laying a foundation for the further development of gene editing technology for Bacteroides.
CRISPR-Cas Systems/genetics*
;
Gene Editing/methods*
;
Bacteroides/genetics*
;
Humans
;
Gastrointestinal Microbiome/genetics*
;
Bacteroides fragilis/genetics*
3.A minimally invasive, fast on/off "odorgenetic" method to manipulate physiology.
Yanqiong WU ; Xueqin XU ; Shanchun SU ; Zeyong YANG ; Xincai HAO ; Wei LU ; Jianghong HE ; Juntao HU ; Xiaohui LI ; Hong YU ; Xiuqin YU ; Yangqiao XIAO ; Shuangshuang LU ; Linhan WANG ; Wei TIAN ; Hongbing XIANG ; Gang CAO ; Wen Jun TU ; Changbin KE
Protein & Cell 2025;16(7):615-620
4.Effect of self-made static progressive braces in the stepwise treatment of hand flexion dysfunction caused by scar contracture after burn injury
Haiyang ZHAO ; Qin ZHOU ; Jiaqi LIU ; Wanfu ZHANG ; Chan ZHU ; Jing XU ; Juntao HAN ; Dahai HU ; Hao GUAN
Chinese Journal of Burns 2025;41(2):155-162
Objective:To explore the effect of self-made static progressive braces in the stepwise treatment of hand flexion dysfunction caused by scar contracture after burn injury.Methods:This study was a retrospective observational study. From January 2022 to March 2024, the First Affiliated Hospital of Air Force Medical University admitted twenty-nine patients who met the inclusion criteria and used the self-made static progressive braces for stepwise treatment of hand flexion dysfunction caused by scar contracture, including 23 males and 6 females, aged 16 to 55 years. The depth of burn on the back of the hand was deep partial-thickness to full-thickness. The self-made static progressive brace referred to the self-made static progressive joint distractor and the self-made static progressive hand flexion distractor. The stepwise treatment was adopted. In the first stage, in-hospital treatment for 2 to 4 weeks was selected. The treatment contents included conventional rehabilitation training and training on the application of the self-made joint distractors. When the active flexion range of motion of the metacarpophalangeal joint was ≥60°, the second stage of treatment was carried out, that is, two weeks of home remote rehabilitation treatment. The treatment contents included individualized exercise training such as training with self-made static progressive joint distractors and training with self-made static progressive hand flexion distractors. Adverse events such as blister, brace compression, and tissue strain during the stepwise treatment were recorded. After the end of the stepwise treatment, the active flexion of the affected hand was observed. During follow-up, the total active range of motion of the affected hand was measured, and the extensibility of the scar and skin and soft tissue on the back of the affected hand and the patient's satisfaction with the therapeutic effect were evaluated. At the last follow-up, the function of the affected hand was evaluated according to the trial standards for evaluation of partial function of upper extremity by the Hand Surgery Society of Chinese Medical Association.Results:During the stepwise treatment, a small amount of blisters developed on the skin at the wrist joint in 2 patients, which was cured after symptomatic treatment; the other patients had no adverse events such as brace compression and tissue strain. After the end of the stepwise treatment, the active flexion function of the hand was better, and the fist could be basically clenched. After 1-3 months of follow-up, the total active range of motion of the affected hand was 200-245°; the scar on the back of the hand was soft and light-colored, and the skin and soft tissue was malleable. Twenty-two patients were very satisfied with the curative effect, 6 patients were satisfied, and 1 patient was dissatisfied. At the last follow-up, there were 20 cases with excellent hand function and 9 cases with good hand function.Conclusions:The stepwise treatment of hand flexion dysfunction caused by scar contracture after burn injury with self-made static progressive braces has a good effect and few complications. Moreover, the two self-made static progressive distractors are convenient in material acquisition, simple to make, cost-effective, and highly practical, which is worthy of clinical promotion.
5.Combining proprioceptive training with core stability training improves the balance and lower limb motor functioning of burns patients
Haiyang ZHAO ; Juntao HAN ; Jiaqi LIU ; Dahai HU ; Qin ZHOU ; Chan ZHU ; Jin XU ; Bowen ZHANG ; Zongshi QI
Chinese Journal of Physical Medicine and Rehabilitation 2025;47(5):425-429
Objective:To observe any influence of combining proprioceptive training with core stability training in rehabilitation motor functioning and balance after extensive burns.Methods:Sixty patients with lower limb motor and balance disorders after extensive burns were randomly divided into a treatment group and a control group, each of 30. Both groups underwent skin grafting on the lower limbs. After the wounds had healed, both groups were given routine rehabilitation treatment, including joint stretching and muscle strength training, but the treatment group was additionally provided with proprioception and core stability training. Before and after 12 weeks of treatment, both groups′ lower limb motor function and walking ability were evaluated using the Fugl-Meyer Assessment (L-FMA), and static and dynamic balance were quantified using Holden Functional Ambulation Classification (FAC). The duration of standing on one leg with the eyes closed was recorded, along with Timed " Up & Go" Test (TUGT) times. After the treatment, each patient′s satisfaction was assessed using a self-designed questionnaire.Results:Significant improvement was observed in the average L- FMA and FAC scores after the treatment, as well as in the ability to stand on one leg with the eyes closed. The average TUGT time in both groups was shorter, but there had been significantly greater improvement of the treatment group than among the controls. Reported satisfaction was significantly higher among the treated group than among the controls.Conclusions:Supplementing basic rehabilitation with proprioception training and core stability training can further improve the motor functioning, balance and walking of persons who have suffered extensive burns.
6.Effect of self-made static progressive braces in the stepwise treatment of hand flexion dysfunction caused by scar contracture after burn injury
Haiyang ZHAO ; Qin ZHOU ; Jiaqi LIU ; Wanfu ZHANG ; Chan ZHU ; Jing XU ; Juntao HAN ; Dahai HU ; Hao GUAN
Chinese Journal of Burns 2025;41(2):155-162
Objective:To explore the effect of self-made static progressive braces in the stepwise treatment of hand flexion dysfunction caused by scar contracture after burn injury.Methods:This study was a retrospective observational study. From January 2022 to March 2024, the First Affiliated Hospital of Air Force Medical University admitted twenty-nine patients who met the inclusion criteria and used the self-made static progressive braces for stepwise treatment of hand flexion dysfunction caused by scar contracture, including 23 males and 6 females, aged 16 to 55 years. The depth of burn on the back of the hand was deep partial-thickness to full-thickness. The self-made static progressive brace referred to the self-made static progressive joint distractor and the self-made static progressive hand flexion distractor. The stepwise treatment was adopted. In the first stage, in-hospital treatment for 2 to 4 weeks was selected. The treatment contents included conventional rehabilitation training and training on the application of the self-made joint distractors. When the active flexion range of motion of the metacarpophalangeal joint was ≥60°, the second stage of treatment was carried out, that is, two weeks of home remote rehabilitation treatment. The treatment contents included individualized exercise training such as training with self-made static progressive joint distractors and training with self-made static progressive hand flexion distractors. Adverse events such as blister, brace compression, and tissue strain during the stepwise treatment were recorded. After the end of the stepwise treatment, the active flexion of the affected hand was observed. During follow-up, the total active range of motion of the affected hand was measured, and the extensibility of the scar and skin and soft tissue on the back of the affected hand and the patient's satisfaction with the therapeutic effect were evaluated. At the last follow-up, the function of the affected hand was evaluated according to the trial standards for evaluation of partial function of upper extremity by the Hand Surgery Society of Chinese Medical Association.Results:During the stepwise treatment, a small amount of blisters developed on the skin at the wrist joint in 2 patients, which was cured after symptomatic treatment; the other patients had no adverse events such as brace compression and tissue strain. After the end of the stepwise treatment, the active flexion function of the hand was better, and the fist could be basically clenched. After 1-3 months of follow-up, the total active range of motion of the affected hand was 200-245°; the scar on the back of the hand was soft and light-colored, and the skin and soft tissue was malleable. Twenty-two patients were very satisfied with the curative effect, 6 patients were satisfied, and 1 patient was dissatisfied. At the last follow-up, there were 20 cases with excellent hand function and 9 cases with good hand function.Conclusions:The stepwise treatment of hand flexion dysfunction caused by scar contracture after burn injury with self-made static progressive braces has a good effect and few complications. Moreover, the two self-made static progressive distractors are convenient in material acquisition, simple to make, cost-effective, and highly practical, which is worthy of clinical promotion.
7.Effect of mild hypothermia on macrophage polarization in lipopolysaccharide-induced acute lung injury mice
Bixia ZHANG ; Liangyan JIANG ; Lichuang HUANG ; Juntao HU ; Zhanhong TANG
Chinese Critical Care Medicine 2024;36(5):514-519
Objective:To investigate the effect of mild hypothermia on macrophage polarization in lipopolysaccharide (LPS)-induced acute lung injury (ALI) mice and to clarify its role in lung injury.Methods:According to a random number table method, 18 male C57BL/6 mice were divided into sham operation group (Sham group), ALI normothermic model group (NT group) and ALI mild hypothermia treatment group (HT group), with 6 mice in each group. The ALI model in mice was established by the method of tracheal instillation of LPS, and temperature control was administered at 1 hour after surgery. The anus temperature in NT group was kept at 36-38?℃, while the anus temperature in HT group was kept at 32-34?℃. The target anus temperature in both groups were maintained for 6 hours and then slowly rewarmed to 36-38 ℃. The Sham group was infused with an equal amount of physiological saline through the trachea without temperature control. After 24 hours of modeling, serum was collected and mice were sacrificed to obtain lung tissue. Pathological changes in lung tissue were observed under light microscopy and semi-quantitative lung injury score was performed. Enzyme linked immunosorbent assay (ELISA) was used to detect the serum levels of interleukins (IL-1β, IL-10). Real-time quantitative polymerase chain reaction (RT-qPCR) was used to test the indicators of macrophage polarization, such as the mRNA expressions of CD86, IL-6, CD206 and arginase 1 (Arg1) in the lung tissue. The protein expression of M1 macrophage marker inducible nitric oxide synthase (iNOS) and M2 macrophage marker Arg1 were detected by Western blotting.Results:Compared with the Sham group, the NT group appeared significant pulmonary hemorrhage and edema, thickened lung septum, inflammatory cell infiltration, and lung injury score was significantly increased; serum IL-1β level was significantly elevated; IL-10 level was increased without statistical significance; the expressions of CD86 mRNA, IL-6 mRNA and iNOS protein were significantly elevated, and CD206 mRNA was significantly decreased; the mRNA and protein expressions of Arg1 decreased, but there were no significant differences. Compared with the NT group, the pathological injury of lung tissue in HT group was significantly reduced, and the lung injury score was significantly decreased (4.78±0.96 vs. 8.56±1.98, P < 0.01); serum IL-1β level was decreased (ng/L: 13.52±1.95 vs. 27.18±3.87, P < 0.01), and IL-10 level was significantly increased (ng/L: 42.59±15.79 vs. 14.62±4.47, P < 0.01); IL-6 mRNA expression was decreased in lung tissue (2 -ΔΔCt: 3.37±0.92 vs. 10.04±0.91, P < 0.05), the expression of M1 macrophage markers CD86 mRNA and iNOS protein were significantly decreased [CD86 mRNA (2 -ΔΔCt): 0.52±0.16 vs. 1.95±0.33, iNOS protein (iNOS/β-actin): 0.57±0.19 vs. 1.11±0.27, both P < 0.05], the expression of M2 macrophage markers CD206 mRNA, Arg1 mRNA and Arg1 protein were significantly increased [CD206 mRNA (2 -ΔΔCt): 3.99±0.17 vs. 0.34±0.17, Arg1 mRNA (2 -ΔΔCt): 2.33±0.73 vs. 0.94±0.23, Arg1 protein (Arg1/β-actin): 0.96±0.09 vs. 0.31±0.11, all P < 0.05]. Conclusion:Mild hypothermia can alleviate the inflammatory response and protect lung tissue in ALI mice, which may be related to the inhibition of M1 macrophage polarization and promotion of M2 macrophage polarization.
8.Identification of Protein-Coding Gene Markers in Breast Invasive Carcinoma Based on Machine Learning
Yue WU ; Kaiyuan MIN ; Jiangfeng LIU ; Wanfeng LIANG ; Yehong YANG ; Gang HU ; Juntao YANG
Acta Academiae Medicinae Sinicae 2024;46(2):147-153
Objective To screen out the biomarkers linked to prognosis of breast invasive carcinoma based on the analysis of transcriptome data by random forest(RF),extreme gradient boosting(XGBoost),light gradient boosting machine(LightGBM),and categorical boosting(CatBoost).Methods We obtained the ex-pression data of breast invasive carcinoma from The Cancer Genome Atlas and employed DESeq2,t-test,and Cox univariate analysis to identify the differentially expressed protein-coding genes associated with survival prog-nosis in human breast invasive carcinoma samples.Furthermore,RF,XGBoost,LightGBM,and CatBoost mod-els were established to mine the protein-coding gene markers related to the prognosis of breast invasive cancer and the model performance was compared.The expression data of breast cancer from the Gene Expression Omnibus was used for validation.Results A total of 151 differentially expressed protein-coding genes related to survival prog-nosis were screened out.The machine learning model established with C3orf80,UGP2,and SPC25 demonstrated the best performance.Conclusions Three protein-coding genes(UGP2,C3orf80,and SPC25)were screened out to identify breast invasive carcinoma.This study provides a new direction for the treatment and diagnosis of breast invasive carcinoma.
9.Interferon-γ Correlation with the severity of septic shock in patients and its prognostic value
Lich-Uang HUANG ; Liangyan JIANG ; Bixia ZHANG ; Shaolei WU ; Juntao HU ; Zhanhong TANG
The Journal of Practical Medicine 2024;40(12):1725-1730
Objective To explore the correlation between the expression level of interferon gamma(IFN-γ)and the severity of patients with septic shock and its prognostic value.Methods The clinical data and serum of 96 septic shock patients admitted to the Department of Critical Care Medicine,the First Affiliated Hospital of Guangxi Medical University from March 2022 to August 2023 were collected,and divided into survival group and death group according to the 28-day outcome;collected at the same time Sera from 30 healthy people undergoing physi-cal examination during the same period served as the control group.The enzyme-linked immunosorbent(ELISA)method was used to detect the expression levels of IFN-γ in the three groups,and the expression levels of IFN-γ and various clinical data between the groups were analyzed.Results The serum IFN-γ expression level of patients with septic shock was lower than that of healthy people undergoing physical examination,212.80(151.11,255.79)ng/L compared with 343.37(314.5,427.95)ng/L,P<0.01.Among the 96 cases of septic shock,There were 54 cases in the survival group and 42 cases in the death group.The clinical data of the two groups were com-pared.The gender,smoking history,SBP,DBP,SI,Lac,IL-6,IFN-γ,PCT,SOFA score,and APACHEⅡscore of the two groups of patients were compared.The difference is statistically significant(P<0.01).Logistic regression analysis showed that decreased expression of Lac,IFN-γ,and APACHEⅡ score were independent risk factors for death in patients with septic shock.[Odds ratio(OR)and 95%confidence interval(95%CI)were 6.491(1.404~30.004)respectively.0.954(0.954~0.999),3.476(1.210~9.984),P<0.05].The Spearman correlation analysis of INF-γ,Lac and APACHEⅡ showed a negative correlation,and the correlation coefficients were-0.38 and-0.35 respectively.Drawing the ROC curves of Lac,IFN-γ,and APACHEII,the AUCs of the three were 0.847,0.869,and 0.833 respectively.The AUC of the three joint predictions was 0.978.The joint prediction value of the three was better than that of a single indicator,P<0.001.Conclusion The decrease in IFN-γ expression level and the severity of septic shock patients have good prognostic value.
10.Numerical Simulation of Biomechanics of Two Aortic Root Replacement Procedures with Valve Preservation
Qian WANG ; Xinjin LUO ; Juntao QIU ; Shengyi HU ; Xuechao DING ; Tianming DU ; Yanping ZHANG ; Qianwen HOU ; Aike QIAO
Journal of Medical Biomechanics 2024;39(4):691-698
Objective To elucidate the influence of two procedures aortic root remodeling using a straight tubular artificial vessel while preserving the aortic valve and the Florida sleeve procedure on the biomechanics of the aortic root.Methods Five finite element models of the aortic root were reconstructed using computed tomography angiography images,including two cases of aortic root remodeling(A1 and A2),two cases of the Florida sleeve procedure(B1 and B2),and one control group without aortic root pathology(C).Numerical simulations were performed to obtain the blood flow and pressure distribution result to assess the differences in the hemodynamics of the aortic root.Results There were no significant differences in the peak systolic velocity between the two procedures and the control.However,the flow velocity after aortic root remodeling was smoother,similar to the model of the control group,with a more stable average aortic pressure and wall shear stress.In the Florida sleeve procedure,high-speed blood flow affected the vessel wall,leading to various degrees of wall shear stress and pressure concentrations along the aortic wall.Conclusions After aortic root replacement with valve preservation,blood flow patterns in the reconstructed aortic root depended on postoperative changes in sinus geometry.Both surgical procedures showed favorable blood flow patterns;however,the flow pattern after aortic root remodeling was more stable than that after the Florida sleeve procedure.

Result Analysis
Print
Save
E-mail