1.Innovations and development in liver transplantation surgery techniques
Organ Transplantation 2025;16(6):853-858
Liver transplantation, as the only effective radical treatment for end-stage liver disease, has evolved from a high-risk exploratory surgery to a mature routine treatment over nearly six decades. This article systematically reviews the development of liver transplantation surgical techniques, focusing on innovations in key areas such as the deferred total hepatectomy combined with partial liver transplantation of segments Ⅱ to Ⅲ, technical advancements in liver autotransplantation, application of minimally invasive and robotic techniques, and breakthroughs in liver xenotransplantation. It analyzes the specific surgical characteristics, clinical application advantages and disadvantages and existing problems of these liver transplantation techniques. Meanwhile, combining the characteristics and contributions of liver transplantation in China, it discusses the current challenges and future development directions of liver transplantation. Precision, minimally invasiveness, efficient utilization of marginal donor livers, and the clinical application of xenogeneic donor livers will lead liver transplantation surgery into a new era.
2.Impact of Intravascular Ultrasalnd-guided Drug-eluting Stent Implantation on Long-term Outcome of Patients With Coronary Artery Disease and Chronic Kidney Disease
Jingyu ZHAO ; Congfei ZHU ; Ling LIN ; Guangfeng ZUO ; Xiangquan KONG ; Zhen GE ; Xiaofei GAO ; Junjie ZHANG
Chinese Circulation Journal 2025;40(9):898-903
Objectives:To assess the impact of intravascular ultrasound(IVUS)guidance for drug-eluting stent(DES)implantation on the long-term outcomes in coronary artery disease(CAD)patients with chronic kidney disease(CKD).Methods:A retrospective study was conducted on 1 800 CAD and CKD patients who underwent coronary DES implantation at Nanjing First Hospital from January 2018 to December 2022.Patients were divided into IVUS-guided group(IVUS group,n=333)and angiography-guided group(angiography group,n=1 467).Propensity score matching(PSM)was performed at a 1:2 ratio to adjust for differences in baseline clinical and angiographic characteristics between the two groups.Major adverse cardiovascular events(MACE),including cardiac death,target vessel myocardial infarction,and clinically driven target vessel revascularization,were evaluated over a 2-year follow-up.Cox proportional hazards regression was performed to identify independent predictors of MACE.Results:After propensity score matching,333 patients in the IVUS group were matched with 666 patients in the angiography group.Following matching,there were no significant differences in clinical characteristics and angiographic data between the two groups(all P>0.05).Regarding procedural data,IVUS group had a higher number of stents implanted,longer total stent length,larger average stent diameter,more frequent use of post-dilation balloons,larger post-dilation balloon diameter,and greater contrast agent usage(all P<0.05).MACE rate was significantly higher in the angiography group than that in the IVUS group(23.9%vs.18.0%,P=0.037).The difference was mainly attributed to a higher rate of cardiac death in the angiography group(16.1%vs.10.8%,P=0.013).Additionally,patients in angiography group had a significantly higher all-cause mortality rate compared to IVUS group(19.7%vs.13.8%,P=0.022).Multivariate cox regression analysis showed that IVUS guidance(HR=0.73,95%CI:0.55-0.99,P=0.042)was an independent protective factor,while hypertension(HR=1.60,95%CI:1.13-2.26,P=0.008),type 2 diabetes(HR=1.56,95%CI:1.19-2.05,P=0.001),acute coronary syndrome(HR=1.92,95%CI:1.12-3.30,P=0.018),and moderate to severe calcification(HR=1.55,95%CI:1.18-2.04,P=0.002)were independent risk factors for MACE at 2 years after DES implantation in CKD patients.Conclusions:Patients with CAD and CKD,IVUS-guided DES implantation is associated with a reduced risk of MACE and all-cause mortality at 2 years post-procedure compared to coronary angiography-guided implantation.
3.Impact of Intravascular Ultrasalnd-guided Drug-eluting Stent Implantation on Long-term Outcome of Patients With Coronary Artery Disease and Chronic Kidney Disease
Jingyu ZHAO ; Congfei ZHU ; Ling LIN ; Guangfeng ZUO ; Xiangquan KONG ; Zhen GE ; Xiaofei GAO ; Junjie ZHANG
Chinese Circulation Journal 2025;40(9):898-903
Objectives:To assess the impact of intravascular ultrasound(IVUS)guidance for drug-eluting stent(DES)implantation on the long-term outcomes in coronary artery disease(CAD)patients with chronic kidney disease(CKD).Methods:A retrospective study was conducted on 1 800 CAD and CKD patients who underwent coronary DES implantation at Nanjing First Hospital from January 2018 to December 2022.Patients were divided into IVUS-guided group(IVUS group,n=333)and angiography-guided group(angiography group,n=1 467).Propensity score matching(PSM)was performed at a 1:2 ratio to adjust for differences in baseline clinical and angiographic characteristics between the two groups.Major adverse cardiovascular events(MACE),including cardiac death,target vessel myocardial infarction,and clinically driven target vessel revascularization,were evaluated over a 2-year follow-up.Cox proportional hazards regression was performed to identify independent predictors of MACE.Results:After propensity score matching,333 patients in the IVUS group were matched with 666 patients in the angiography group.Following matching,there were no significant differences in clinical characteristics and angiographic data between the two groups(all P>0.05).Regarding procedural data,IVUS group had a higher number of stents implanted,longer total stent length,larger average stent diameter,more frequent use of post-dilation balloons,larger post-dilation balloon diameter,and greater contrast agent usage(all P<0.05).MACE rate was significantly higher in the angiography group than that in the IVUS group(23.9%vs.18.0%,P=0.037).The difference was mainly attributed to a higher rate of cardiac death in the angiography group(16.1%vs.10.8%,P=0.013).Additionally,patients in angiography group had a significantly higher all-cause mortality rate compared to IVUS group(19.7%vs.13.8%,P=0.022).Multivariate cox regression analysis showed that IVUS guidance(HR=0.73,95%CI:0.55-0.99,P=0.042)was an independent protective factor,while hypertension(HR=1.60,95%CI:1.13-2.26,P=0.008),type 2 diabetes(HR=1.56,95%CI:1.19-2.05,P=0.001),acute coronary syndrome(HR=1.92,95%CI:1.12-3.30,P=0.018),and moderate to severe calcification(HR=1.55,95%CI:1.18-2.04,P=0.002)were independent risk factors for MACE at 2 years after DES implantation in CKD patients.Conclusions:Patients with CAD and CKD,IVUS-guided DES implantation is associated with a reduced risk of MACE and all-cause mortality at 2 years post-procedure compared to coronary angiography-guided implantation.
4.Early outcomes of domestic left ventricular assist device implantation with or without concomitant mitral valvuloplasty
Zhihua WANG ; Zeyuan ZHAO ; Junlong HU ; Junjie SUN ; Kun LIU ; Xiaoxia DUAN ; Sheng WANG ; Zhaoyun CHENG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(11):1599-1605
Objective To compare the early outcomes of domestic third-generation magnetically levitated left ventricular assist device (LVAD) with or without concomitant mitral valvuloplasty (MVP). Methods The clinical data of 17 end-stage heart failure patients who underwent LVAD implantation combined with preoperative moderate to severe mitral regurgitation in Fuwai Central China Cardiovascular Hospital from May 2018 to March 2023 were retrospectively analyzed. The patients were divided into a LVAD group and a LVAD+MVP group based on whether MVP was performed simultaneously, and early outcomes were compared between the two groups. Results There were 4 patients in the LVAD group, all males, aged (43.5±5.9) years, and 13 patients in the LVAD+MVP group, including 10 males and 3 females, aged (46.8±16.7) years. All the patients were successful in concomitant MVP without mitral reguragitation occurrence. Compared with the LVAD group, the LVAD+MVP group had a lower pulmonary artery systolic pressure and pulmonary artery mean pressure 72 h after operation, but the difference was not statistically different (P>0.05). Pulmonary artery systolic pressure was significantly lower 1 week after operation, as well as pulmonary artery systolic blood pressure and pulmonary artery mean pressure at 1 month after operation (P<0.01). There was no statistically significant difference in blood loss, operation time, cardiopulmonary bypass time, aortic cross-clamping time, mechanical ventilation time, or ICU stay time between the two groups (P>0.05). The differences in 1-month postoperative mortality, acute kidney injury, reoperation, gastrointestinal bleeding, and thrombosis and other complications between the two groups were not statistically significant (P>0.05). Conclusion Concomitant MVP with implantation of domestic third-generation magnetically levitated LVAD is safe and feasible, and concomitant MVP may improve postoperative hemodynamics without significantly increasing perioperative mortality and complication rates.
5.Long-term outcomes of intravascular ultrasound-guided drug-eluting stents implantation in patients with acute coronary syndrome: ULTIMATE ACS subgroup
Xiaofei GAO ; Leng HAN ; Xuesong QIAN ; Zhen GE ; Xiangquan KONG ; Shu LU ; Jing KAN ; Guangfeng ZUO ; Junjie ZHANG ; Shaoliang CHEN
Chinese Journal of Cardiology 2024;52(2):137-143
Objective:To explore the long-term effects of intravascular ultrasound (IVUS) guidance on patients with acute coronary syndrome (ACS) undergoing drug-eluting stents (DES) implantation.Methods:Data used in this study derived from ULTIMATE trial, which was a prospective, multicenter, randomized study. A total of 1 448 all-comer patients were enrolled between 2014 August and 2017 May. Primary endpoint of this study was target vessel failure (TVF) at 3 years, including cardiac death, target-vessel-related myocardial infarction, and clinically-driven target vessel revascularization.Results:ACS was present in 1 136 (78.5%) patients, and 3-year clinical follow-up was available in 1 423 patients (98.3%). TVF in the ACS group was 9.6% (109/1 136), which was significantly higher than 4.5% (14/312) in the non-ACS group (log-rank P=0.005). There were 109 TVFs in the ACS patients, with 7.6% (43/569) TVFs in the IVUS group and 11.6% (66/567) TVFs in the angiography group (log-rank P=0.019). Moreover, patients with optimal IVUS guidance were associated with a lower risk of 3-year TVF compared to those with suboptimal IVUS results (5.4% (16/296) vs. 9.9% (27/273),log-rank P=0.041). Conclusions:This ULTIMATE-ACS subgroup analysis showed that ACS patients undergoing DES implantation were associated with a higher risk of 3-year TVF. More importantly, the risk of TVF could be significantly decreased through IVUS guidance in patients with ACS, especially in those who had an IVUS-defined optimal procedure.
6.Transcatheter Aortic Valve Replacement in Patients With Pure Native Aortic Regurgitation: Results From a Multicenter Registry Study
Xiaofei GAO ; Juan ZHANG ; Xiangquan KONG ; Jing CHEN ; Xiang CHEN ; Longyan ZHANG ; Xinyong CAI ; Jiancheng ZHU ; Nailiang TIAN ; Zhen GE ; Bin WANG ; Qing ZHOU ; Xi SU ; Lang HONG ; Yan WANG ; Hong JIANG ; Junjie ZHANG ; Shaoliang CHEN
Cardiology Discovery 2024;04(2):134-141
Objective::Patients with untreated severe aortic regurgitation (AR) have a high risk of mortality. Transfemoral transcatheter aortic valve replacement (TF-TAVR) is a treatment option for AR; however, the safety and efficacy of this technique have not been sufficiently established. This study aimed to evaluate the clinical and anatomical variables correlating with device success of TF-TAVR using a self-expanding valve system for pure AR.Methods::Patients with pure native severe AR who underwent TF-TAVR using a self-expanding valve system were registered at 5 Chinese centers. The primary endpoint was device success at 1 month after TAVR. The secondary endpoint was the composite of major adverse cardiovascular events (MACE) at 6 months, including all-cause death, ischemic stroke, emergency conversion to cardiac surgery, and permanent pacemaker implantation. Echocardiography was used to analyze the left ventricular function before the TAVR procedure and during follow-up. Multivariable logistic regression and Cox regression analyses were performed to find relevant independent risk factors.Results::Between September 2019 and February 2022, 79 patients with AR were enrolled in the study. At 1 month, device success was achieved in 60 (75.9%) patients. By 6 months, 29 (36.7%) patients had MACE. Echocardiography revealed improved left ventricular function after TAVR. Multivariate regression analysis demonstrated that the Society of Thoracic Surgeons risk score (odds ratio 0.760, 95% confidence interval (CI): 0.584-0.989; P = 0.041) and annulus perimeter (odds ratio 0.888, 95% CI: 0.796-0.992; P = 0.035) were 2 predictors of device success. Moreover, annulus perimeter (<80.2 mm), but not Society of Thoracic Surgeons risk score, was associated with a significant reduction in MACE at 6 months (hazard ratio 2.223, 95% CI: 1.060-4.659; P = 0.028). Conclusions::TF-TAVR using a self-expanding valve system appears to be a safe and feasible treatment for patients with pure native severe AR, particularly those with a less enlarged annulus.
7.Transcatheter Aortic Valve Replacement in Patients With Pure Native Aortic Regurgitation: Results From a Multicenter Registry Study
Xiaofei GAO ; Juan ZHANG ; Xiangquan KONG ; Jing CHEN ; Xiang CHEN ; Longyan ZHANG ; Xinyong CAI ; Jiancheng ZHU ; Nailiang TIAN ; Zhen GE ; Bin WANG ; Qing ZHOU ; Xi SU ; Lang HONG ; Yan WANG ; Hong JIANG ; Junjie ZHANG ; Shaoliang CHEN
Cardiology Discovery 2024;04(2):134-141
Objective::Patients with untreated severe aortic regurgitation (AR) have a high risk of mortality. Transfemoral transcatheter aortic valve replacement (TF-TAVR) is a treatment option for AR; however, the safety and efficacy of this technique have not been sufficiently established. This study aimed to evaluate the clinical and anatomical variables correlating with device success of TF-TAVR using a self-expanding valve system for pure AR.Methods::Patients with pure native severe AR who underwent TF-TAVR using a self-expanding valve system were registered at 5 Chinese centers. The primary endpoint was device success at 1 month after TAVR. The secondary endpoint was the composite of major adverse cardiovascular events (MACE) at 6 months, including all-cause death, ischemic stroke, emergency conversion to cardiac surgery, and permanent pacemaker implantation. Echocardiography was used to analyze the left ventricular function before the TAVR procedure and during follow-up. Multivariable logistic regression and Cox regression analyses were performed to find relevant independent risk factors.Results::Between September 2019 and February 2022, 79 patients with AR were enrolled in the study. At 1 month, device success was achieved in 60 (75.9%) patients. By 6 months, 29 (36.7%) patients had MACE. Echocardiography revealed improved left ventricular function after TAVR. Multivariate regression analysis demonstrated that the Society of Thoracic Surgeons risk score (odds ratio 0.760, 95% confidence interval (CI): 0.584-0.989; P = 0.041) and annulus perimeter (odds ratio 0.888, 95% CI: 0.796-0.992; P = 0.035) were 2 predictors of device success. Moreover, annulus perimeter (<80.2 mm), but not Society of Thoracic Surgeons risk score, was associated with a significant reduction in MACE at 6 months (hazard ratio 2.223, 95% CI: 1.060-4.659; P = 0.028). Conclusions::TF-TAVR using a self-expanding valve system appears to be a safe and feasible treatment for patients with pure native severe AR, particularly those with a less enlarged annulus.
8.Effect of exosomes derived from Echinococcus multilocularis on macrophage polarization: A preliminary study
Gengbo YE ; Gongfu CHEN ; Ziyan CUI ; Junjie WU ; Dengliang HUANG ; Fengjiao YIN ; Zhixin WANG ; Wenhao YU ; Fanyu KONG ; Haining FAN ; Li REN
Journal of Clinical Hepatology 2023;39(4):876-884
Objective To investigate the effect of exosomes derived from Echinococcus multilocularis on macrophage polarization after treatment for different durations and concentrations. Methods A total of 60 BALB/c mice were used for modeling, among which 4 mice were selected to observe the growth of abdominal lesions on 7.0T MRI. The mice for modeling were dissected, and the protoscoleces was taken from the abdominal lesion and cultured in vitro ; ultracentrifugation was used to extract the exosomes from the supernatant, and transmission electron microscopy and Western blotting were used for the characterization of exosomes. The macrophages without exosome treatment were established as control group, and the macrophages co-cultured with different concentrations of exosomes derived from Echinococcus multilocularis were established as experimental group (10 μg/mL group and 50 μg/mL group) and were cultured for 48 and 72 hours. The morphological changes of macrophages were observed under a microscope, and flow cytometry and ELISA were used to observe polarization state. A one-way analysis of variance was used for comparison of normally distributed continuous data between multiple groups, and the least significant difference t -test was used for further comparison between two groups. Results The results of 7.0T MRI showed the formation of diffuse lesions with different sizes in the abdominal cavity of mice, and the exosomes derived from Echinococcus multilocularis were approximately 100 nm in diameter and were cup-shaped or saucer-shaped, with the positive expression of the surface markers CD9, TSG101, and CD63. After co-culture, most of the cells in the experimental group were elongated with an irregular and polygonal shape. Flow cytometry showed that after 48 hours of co-culture, the positive rates of CD16/32, CD206, and CD369 in the control group were 99.53%±0.06%, 90.27%±0.21%, and 2.40%±0.20%, respectively; compared with the control group, except that the 10 μg/mL exosome group had a significant reduction in the positive rate of CD369 (0.80%±0.00%) ( P < 0.05), all the other groups had a significant increase in the positive rates of CD16/32, CD206, and CD369 (all P < 0.000 1); after 72 hours of co-culture, the positive rates of CD16/32, CD206, and CD369 in the control group were 99.67%±0.06%, 85.47%±0.55%, and 6.60%±0.20%, respectively, and compared with the control group, the experimental group had significant increases in the positive rates of CD16/32, CD206, and CD369 (all P < 0.05). ELISA showed that after 48 hours of co-culture, the levels of IL-6 and TNFα in the control group were 58.53±15.52 pg/mL and 320.70±5.30 pg/mL, respectively, and when the exosome concentration was 50 μg/mL, the level of IL-6 in the experimental group was 98.81±15.55 pg/mL, which was higher than that in the control group ( P < 0.05); after 72 hours of co-culture, the levels of IL-6 and TNFα in the control group were 76.22±9.68 pg/mL and 323.90±87.37 pg/mL, respectively, and when the exosome concentration was 10 μg/mL, the level of TNFα was 164.20±14.17 pg/mL, which was significantly lower than that in the control group ( P < 0.05); when the exosome concentration was 50 μg/mL, the level of IL-6 was 99.52±8.35 pg/mL, which was significantly higher than that in the control group ( P < 0.05). Conclusion Exosomes derived from Echinococcus multilocularis can regulate macrophage polarization and induce M2-like polarization of macrophages after co-culture at a concentration of 10 μg /mL for 72 hours, and further studies are needed to clarify the specific method.
9.Discussion on diagnosis and treatment of dizziness from cases.
Lisheng YU ; Weijia KONG ; Haiwei HUANG ; Sulin ZHANG ; Xin MA ; Fei LI ; Junjie GUO
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2023;37(4):302-306
Dizziness or vertigo is a common clinical symptom, and its underlying etiology is complex. Many clinicians are confused about its diagnosis and treatment. This article presents a case about chronic vestibular syndrome. And case appreciation and academic discussion are conducted by well-known domestic neurologists and otologists, so as to provide a good thinking model and basic ideas for the diagnosis and treatment of dizziness or vertigo, hoping to further improve the diagnosis and treatment level among clinicians.
Humans
;
Dizziness/therapy*
;
Vertigo/etiology*
;
Vestibular Diseases/complications*
;
Otolaryngologists
10.Efficacy of first-line tyrosine kinase inhibitors plus immune checkpoint inhibitors in metastatic fumarate hydratase-deficient renal cell carcinoma
Junru CHEN ; Junjie ZHAO ; Yunze XU ; Wen KONG ; Wensu WEI ; Liru HE ; Fangjian ZHOU ; Wei XUE ; Qiang WEI ; Pei DONG ; Jin ZHANG ; Hao ZENG
Chinese Journal of Urology 2023;44(6):410-415
Objective:To evaluate the efficacy of first-line tyrosine kinase inhibitors (TKI) plus immune checkpoint inhibitors (ICI) in metastatic fumarate hydratase-deficient renal cell carcinoma (FH-deficient RCC).Methods:The data of 87 metastatic FH-deficient RCC patients from West China Hospital ( n=44), Renji Hospital ( n=27) and Sun Yat-sen University Cancer Center (n=16) from Mar 2019 to Aug 2022 were retrospectively analyzed. The median age was 37(30, 47) years, the male to female ratio was 1.9∶1. The median size of tumor was 7.5(5.0, 10.0) cm. Sixty-one patients (70.1%) had germline FH mutations, and 26 patients (29.9%) had somatic FH mutations. Forty-nine patients (56.3%) metastasis disease at initial diagnosis, and 38 patients (43.7%) had metachronous metastasis. The most common site of metastasis was lymph node (41/87, 47.1%), followed by bone (33/87, 37.9%), liver (22/87, 25.3%), and lung (14/87, 16.1%). Fifteen patients (17.2%) had weak expression of FH protein and 59 patients (67.8%) had positive PD-L1 expression. The most common treatments were sintilimab plus axitinib (52/87, 59.8%), followed by pembrolizumab plus cabozantinib (7/87, 8.0%), tirelizumab plus axitinib (6/87, 6.9%), pembrolizumab plus axitinib (5/87, 5.7%), and toripalimab plus axitinib (4/87, 4.6%). Thirteen patients (13/87, 14.9%) received other ICI plus TKI combination treatments. Statistical analysis was conducted using R 4.2.3 software. Kaplan Meier survival curve was used to evaluate survival data, and log-rank test was used to compare differences between treatment groups. Results:The overall objective response rate (ORR) and disease control rate (DCR) of first-line TKI + ICI were 39.1% and 89.7%, respectively. The median progression-free survival (PFS) and overall survival (OS) were 16.5 months and 71.0 months, respectively. For first-line sintilimab plus axitinib, the ORR and DCR were 44.2% and 92.3%, respectively. The median PFS was 17.3 months and the median OS was not reached for this combination treatment. The efficacy of first-line tirelizumab plus axitinib was inferior to other treatment strategies (median PFS: 4.0 vs. 16.6 months, P<0.001; median OS: 22.0 vs. 71.0 months, P=0.043). Subgroup analyses further showed that the efficacy of ICI+ TKI combination therapy was consistent in patients with different clinicopathologic and genomic features. However, patients with liver metastasis had shorter OS than those without liver metastasis (median OS: 26.3 vs. 71.0 months, P=0.021). Conclusion:First-line TKI + ICI is effective for metastatic FH-deficient RCC and can significantly prolong the survival of the patients.

Result Analysis
Print
Save
E-mail