1.How to Identify Type 2 Chronic Rhinosinusitis in East Asian Patients
Shin Hyuk YOO ; Ki-Il LEE ; Gwanghui RYU ; Jun-Sang BAE ; Ji-Hun MO
Journal of Rhinology 2026;33(1):21-28
Chronic rhinosinusitis (CRS) is increasingly recognized as a heterogeneous disease with distinct inflammatory endotypes, among which eosinophilic CRS (ECRS)—a category that substantially overlaps with, but is not equivalent to, Type 2 CRS—is associated with severe symptoms, frequent recurrence, and comorbid asthma. Accurate identification of Type 2 CRS has become clinically essential with the emergence of biologic therapies that target Type 2 inflammatory pathways. However, most diagnostic criteria, including those proposed by European Position Paper on Rhinosinusitis and Nasal Polyps 2020 (EPOS 2020), were developed from Western populations, in which ECRS with nasal polyps predominates. This review critically examines the applicability of these criteria in Asian populations, in which non-eosinophilic and mixed inflammatory endotypes remain prevalent. Evidence from Korean and Japanese cohorts indicates that the EPOS 2020 Type 2 criteria have poor specificity in Asian patients with CRS with nasal polyps, classifying nearly all such patients as Type 2 because of differences in baseline biomarker distributions. We discuss histological thresholds for defining ECRS and highlight that Asian studies support higher tissue eosinophil cut-offs, approximately 70 eosinophils per high-power field (HPF) or around 10% of total inflammatory cells, compared with the 10 eosinophils per HPF recommended by Western guidelines. This review also evaluates outpatient- friendly scoring systems, such as Japanese Epidemiological Survey of Refractory Eosinophilic Chronic Rhinosinusitis (JESREC) and newly proposed Korean diagnostic criteria, as well as emerging machine-learning approaches for noninvasive prediction of ECRS. We conclude that clinicians in Asia should adopt regionally validated criteria that integrate histological, serological, and clinical parameters to accurately identify Type 2 CRS, optimize selection of biologic candidates, and improve prognostic counseling in this population.
2.Cross-Calibration of Bone Mineral Density and Body Composition between GE Lunar Prodigy and Hologic Horizon W Dual Energy X-Ray Absorptiometry Systems
Sujin KIM ; Guen Young LEE ; Jun-Il YOO ; Sang-Wook LEE ; Yong-Chan HA
Journal of Bone Metabolism 2026;33(1):84-93
Background:
Dual energy X-ray absorptiometry (DXA) measurements vary among instruments from different manufacturers. This study aimed to assess the correlation between bone mineral density (BMD) and body composition measured by the GE Lunar Prodigy and Hologic Horizon W DXA systems and to develop conversion equations.
Methods:
A total of 120 healthy volunteers (59 males, 61 females) aged 20 to 70 years were scanned on both DXA systems on the same day. BMD was measured at the lumbar spine (L1-L4) and bilateral femurs. Body composition parameters were measured for the whole body and regional sites. Bland-Altman analysis, Pearson correlation, and concordance correlation coefficient (CCC) were used to assess agreement. Linear regression was performed to derive conversion equations.
Results:
The Hologic system measured BMD values 14% to 20% lower at the lumbar spine and 8% to 17% lower at femoral sites compared to the GE Lunar system (all P<0.0001). Lean mass values were 4% to 10% lower on the Hologic system. Very strong correlations were observed for both BMD (r=0.944-0.980) and lean mass (r=0.963-0.984). Cross-calibration equations were developed for all measurement sites.
Conclusions
Despite significant systematic differences, there was very high correlation between the two DXA systems. The conversion equations can facilitate comparison of measurements between these systems in clinical practice and research.
3.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
4.Comparing Stability, Gait, and Functional Score after 40-mm Dual-Mobility Hip Arthroplasty to 36-mm Head Hip Arthroplasty in Elderly Hip Fracture Patients
Yonghan CHA ; Sang-Yeob LEE ; Ji-Ho BAE ; Yang Jae KANG ; Ji-Hoon BAEK ; Joon Soon KANG ; Chan Ho PARK ; Shinjune KIM ; Jun-Il YOO
Clinics in Orthopedic Surgery 2025;17(1):62-70
Background:
This study aimed to compare the intraoperative stability and early clinical outcomes of 40-mm diameter dual mobility (DM)-total hip arthroplasty (THA) with 36-mm ceramic head (large head) THA in active elderly patients with hip fractures.
Methods:
A prospective randomized controlled trial was conducted from May 2022 to December 2022. Inclusion criteria were as follows: age ≥ 60 years, displaced femoral neck fracture, Koval grade 1 or 2, planned 54-mm acetabular component, and over 1-year follow-up. Intraoperative stability tests were performed on all patients (internal rotation at 45°, 60°, and 90° of hip fracture). Functional outcomes (Harris Hip Score and University of California, Los Angeles [UCLA] Score) were evaluated at 6 weeks and 3 months postoperatively. Gait analysis using artificial intelligence (AI) techniques was conducted at 3 months postoperatively.
Results:
The study included 36 DM-THA patients (mean age, 69.6 ± 2.2 years; 44% women) and 37 large head THA patients (mean age, 69.6 ± 1.2 years; 64% women). No statistically significant differences were observed in functional outcomes and hip range of motion between the 2 groups. However, there was a significant difference in the gait speed and stance-swing phase of the large head THA group and the DM-THA group: the DM-THA group demonstrated superior gait speed (2.85 ± 0.83 kph vs. 2.04 ± 1.04 kph, p = 0.003) and higher stance phase ratios (operated side: 63.57% ± 3.82% vs. 48.19% ± 5.50%, p < 0.001; opposite side: 62.77% ± 2.27% vs. 49.93% ± 6.94%, p < 0.001). In the stability test at 90° of hip flexion, the DM-THA group had a measurement of 48.40° ± 5.17°, while the large head THA group had a measurement of 30.94° ± 2.98° (p = 0.012). Despite the lack of statistical significance, the intraoperative stability test showed the dislocation angle was notably different between the groups in the hip flexion position of 60° (51.60° ± 6.09° in the DM-THA group and 40.00° ± 2.80° in the large head THA group, p = 0.072).
Conclusions
Superior results were observed in the intraoperative stability test and early recovery of gait after DM-THA compared to large head THA. We believe that DM-THA can be a useful surgical option for THA in elderly patients with hip fractures.
5.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
6.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
7.Comparing Stability, Gait, and Functional Score after 40-mm Dual-Mobility Hip Arthroplasty to 36-mm Head Hip Arthroplasty in Elderly Hip Fracture Patients
Yonghan CHA ; Sang-Yeob LEE ; Ji-Ho BAE ; Yang Jae KANG ; Ji-Hoon BAEK ; Joon Soon KANG ; Chan Ho PARK ; Shinjune KIM ; Jun-Il YOO
Clinics in Orthopedic Surgery 2025;17(1):62-70
Background:
This study aimed to compare the intraoperative stability and early clinical outcomes of 40-mm diameter dual mobility (DM)-total hip arthroplasty (THA) with 36-mm ceramic head (large head) THA in active elderly patients with hip fractures.
Methods:
A prospective randomized controlled trial was conducted from May 2022 to December 2022. Inclusion criteria were as follows: age ≥ 60 years, displaced femoral neck fracture, Koval grade 1 or 2, planned 54-mm acetabular component, and over 1-year follow-up. Intraoperative stability tests were performed on all patients (internal rotation at 45°, 60°, and 90° of hip fracture). Functional outcomes (Harris Hip Score and University of California, Los Angeles [UCLA] Score) were evaluated at 6 weeks and 3 months postoperatively. Gait analysis using artificial intelligence (AI) techniques was conducted at 3 months postoperatively.
Results:
The study included 36 DM-THA patients (mean age, 69.6 ± 2.2 years; 44% women) and 37 large head THA patients (mean age, 69.6 ± 1.2 years; 64% women). No statistically significant differences were observed in functional outcomes and hip range of motion between the 2 groups. However, there was a significant difference in the gait speed and stance-swing phase of the large head THA group and the DM-THA group: the DM-THA group demonstrated superior gait speed (2.85 ± 0.83 kph vs. 2.04 ± 1.04 kph, p = 0.003) and higher stance phase ratios (operated side: 63.57% ± 3.82% vs. 48.19% ± 5.50%, p < 0.001; opposite side: 62.77% ± 2.27% vs. 49.93% ± 6.94%, p < 0.001). In the stability test at 90° of hip flexion, the DM-THA group had a measurement of 48.40° ± 5.17°, while the large head THA group had a measurement of 30.94° ± 2.98° (p = 0.012). Despite the lack of statistical significance, the intraoperative stability test showed the dislocation angle was notably different between the groups in the hip flexion position of 60° (51.60° ± 6.09° in the DM-THA group and 40.00° ± 2.80° in the large head THA group, p = 0.072).
Conclusions
Superior results were observed in the intraoperative stability test and early recovery of gait after DM-THA compared to large head THA. We believe that DM-THA can be a useful surgical option for THA in elderly patients with hip fractures.
8.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
9.Generate Quantitative Computed Tomography-Equivalent Computed Tomography Image Interpretation Reports in Patients with Spinal Deformities
Hyunbin KIM ; Hyeon Su KIM ; Shinjune KIM ; Jun-Il YOO
Journal of Bone Metabolism 2025;32(1):31-37
Background:
Quantitative computed tomography (QCT) is essential for assessing osteoporosis and monitoring spinal deformities. “Clari-QCT,” a software that uses artificial intelligence to analyze conventional computed tomography (CT) scans and produce QCTequivalent reports. This study aims to evaluate the effectiveness of Clari-QCT by comparing its results with traditional QCT, with the goal of validating new diagnostic tools for spinal deformities.
Methods:
The study analyzed dual energy X-ray absorptiometry, CT, and QCT data from 18 patients at Inha University Hospital. Clari-QCT software was evaluated for its ability to generate QCT-equivalent reports from CT images. The software processes abdomen CT images, calculates bone density in designated slices, and provides bone mineral density (BMD), T-score, and Z-score values. Patients were classified into normal, mild, and severe spinal deformity groups. Intraclass correlation coefficient (ICC) analysis was used to measure the agreement between actual and predicted BMD values.
Results:
The study included participants with an average age of 64 and a mean body mass index of 24.88. The average BMD was 94.7 g/cm³ by QCT and 122.5 g/cm³ by Clari- QCT, with individual differences ranging from 4.9 to 61.8. T-score discrepancies ranged from 0.16 to 6.86. ICC analysis showed moderate to high agreement between methods, with ICC1 values of 0.597, ICC2 of 0.64, ICC3 of 0.81, and ICC1k, ICC2k, ICC3k values ranging from 0.748 to 0.895.
Conclusions
Clari-QCT demonstrates good agreement with actual QCT measurements in normal and severe spinal deformity groups but shows reduced accuracy in patients with mild deformities. If the limitations are addressed, it could become a useful tool for monitoring bone health in patients with spinal deformities.
10.Profiling of Anti-Signal-Recognition Particle Antibodies and Clinical Characteristics in South Korean Patients With Immune-Mediated Necrotizing Myopathy
Soo-Hyun KIM ; Yunjung CHOI ; Eun Kyoung OH ; Ichizo NISHINO ; Shigeaki SUZUKI ; Bum Chun SUH ; Ha Young SHIN ; Seung Woo KIM ; Byeol-A YOON ; Seong-il OH ; Yoo Hwan KIM ; Hyunjin KIM ; Young-Min LIM ; Seol-Hee BAEK ; Je-Young SHIN ; Hung Youl SEOK ; Seung-Ah LEE ; Young-Chul CHOI ; Hyung Jun PARK
Journal of Clinical Neurology 2025;21(1):31-39
Background:
and Purpose This study evaluated the diagnostic utility of an anti-signal-recognition particle 54 (anti-SRP54) antibody-based enzyme-linked immunosorbent assay (ELISA) as well as the clinical, serological, and pathological characteristics of patients with SRP immune-mediated necrotizing myopathy (IMNM).
Methods:
We evaluated 87 patients with idiopathic inflammatory myopathy and 107 healthy participants between January 2002 and December 2023. The sensitivity and specificity of the ELISA for anti-SRP54 antibodies were assessed, and the clinical profiles of patients with antiSRP54 antibodies were determined.
Results:
The ELISA for anti-SRP54 antibodies had a sensitivity and specificity of 88% and 99%, respectively, along with a test–retest reliability of 0.92 (p<0.001). The 32 patients diagnosed with anti-SRP IMNM using a line-blot immunoassay included 28 (88%) who tested positive for anti-SRP54 antibodies using the ELISA, comprising 12 (43%) males and 16 (57%) females whose median ages at symptom onset and diagnosis were 43.0 years and 43.5 years, respectively. Symptoms included proximal muscle weakness in all 28 (100%) patients, neck weakness in 9 (32%), myalgia in 15 (54%), dysphagia in 5 (18%), dyspnea in 4 (14%), dysarthria in 2 (7%), interstitial lung disease in 2 (7%), and myocarditis in 2 (7%). The median serum creatine kinase (CK) level was 7,261 U/L (interquartile range: 5,086–10,007 U/L), and the median anti-SRP54 antibody level was 2.0 U/mL (interquartile range: 1.0–5.6 U/mL). The serum CK level was significantly higher in patients with coexisting anti-Ro-52 antibodies.
Conclusions
This study has confirmed the reliability of the ELISA for anti-SRP54 antibodies and provided insights into the clinical, serological, and pathological characteristics of South Korean patients with anti-SRP IMNM.

Result Analysis
Print
Save
E-mail