1.Impact of Onset-to-Door Time on Endovascular Therapy for Basilar Artery Occlusion
Tianlong LIU ; Chunrong TAO ; Zhongjun CHEN ; Lihua XU ; Yuyou ZHU ; Rui LI ; Jun SUN ; Li WANG ; Chao ZHANG ; Jianlong SONG ; Xiaozhong JING ; Adnan I. QURESHI ; Mohamad ABDALKADER ; Thanh N. NGUYEN ; Raul G. NOGUEIRA ; Jeffrey L. SAVER ; Wei HU
Journal of Stroke 2025;27(1):140-143
2.Overview of the amendments and revisions to the General Technical Requirements adopted by the Volume Ⅳ of the Chinese Pharmacopoeia 2025 Edition
ZHANG Jun ; NING Baoming ; WEI Shifeng ; SHEN Haoyu ; SHANG Yue ; ZHU Ran ; XU Xinyi ; CHEN Lei ; LIU Tingting ; MA Shuangcheng
Drug Standards of China 2025;26(1):034-044
To introduce the general thinking, guidelines, work objectives and elaboration process of the general technical requirements adopted by volume Ⅳ of the Chinese Pharmacopoeia 2025 Edition, and to summarize and figure out the main characteristics on dosage forms, physico-chemical testing, microbial and biological testing, reference standards and guidelines The newly revised general chapters of pharmacopoeia give full play to the normative and guiding role of the Chinese Pharmacopoeia standard, track the frontier dynamics of international drug regulatory science and the elaboration of monographs, expand the application of state-of-the-art technologies, and steadily promote the harmonization and unification with the ICH guidelines; further enhance the overall capacity of TCM quality control, actively implement the 3 R principles on animal experiments, and practice the concept of environmental-friendly; replace and/or reduce the use of toxic and hazardous reagents, strengthen the requirements of drug safety control This paper aims to provide a full-view perspective for the comprehensive, correct understanding and accurate implementation of general technical requirements included in the Chinese Pharmacopoeia 2025 Edition.
3.Additions and revisions of general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ
XU Xinyi ; WEI Shifeng ; ZHANG Qiming ; HE Langchong ; ZHANG Jun ; MA Shuangcheng
Drug Standards of China 2025;26(1):045-050
Objective: To provide reference for the correct understanding and accurate implementation of the general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ.
Methods: Introduce the main characteristics and content of the additions and revisions of the general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ.
Results: The general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition are more harmonized with the relevant guidelines of the ICH Q series, and the inclusion of advanced and mature instrument analysis technology standards and analysis method standards related to drug safety, efficacy, and quality controllability is further increased.
Conclusion: The general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition have provided a more convenient new bridge for China’s drugs to go international, standardized testing technology support for achieving full process quality control, and better meet the needs of drug research and development, production, quality control, and supervision in China.
4.Overview of the amendments and revisions to the General Technical Requirements adopted by the Volume Ⅳ of the Chinese Pharmacopoeia 2025 Edition
Jun ZHANG ; Baoming NING ; Shifeng WEI ; Haoyu SHEN ; Yue SHANG ; Ran ZHU ; Xinyi XU ; Lei CHEN ; Tingting LIU ; Shuangcheng MA
Drug Standards of China 2025;26(1):34-44
To introduce the general thinking,guidelines,work objectives and elaboration process of the general technical requirements adopted by volume Ⅳ of the Chinese Pharmacopoeia 2025 Edition,and to summarize and figure out the main characteristics on dosage forms,physico-chemical testing,microbial and biological testing,ref-erence standards and guidelines.The newly revised general chapters of pharmacopoeia give full play to the norma-tive and guiding role of the Chinese Pharmacopoeia standard,track the frontier dynamics of international drug regu-latory science and the elaboration of monographs,expand the application of state-of-the-art technologies,and stead-ily promote the harmonization and unification with the ICH guidelines;further enhance the overall capacity of TCM quality control,actively implement the 3 R principles on animal experiments,and practice the concept of environ-mental-friendly;replace and/orreduce the use of toxic and hazardousreagents,strengthen the requirementsofdrug safety control.This paper aims to provide a full-view perspective for the comprehensive,correct understanding and accurate implementation of general technical requirements included in the Chinese Pharmacopoeia 2025 Edition.
5.Additions and revisions of general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ
Xinyi XU ; Shifeng WEI ; Qiming ZHANG ; Langchong HE ; Jun ZHANG ; Shuangcheng MA
Drug Standards of China 2025;26(1):45-50
Objective:To provide reference for the correct understanding and accurate implementation of the general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ.Methods:Intro-duce the main characteristics and content of the additions and revisions of the general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition Volume Ⅳ.Results:The general chapters of physi-cal and chemical analysis in the Chinese Pharmacopoeia 2025 Edition are more harmonized with the relevant guide-lines of the ICH Q series,and the inclusion of advanced and mature instrument analysis technology standards and analysis method standards related to drug safety,efficacy,and quality controllability is further increased.Conclusion:The general chapters of physical and chemical analysis in the Chinese Pharmacopoeia 2025 Edition have provided a more convenient new bridge for China's drugs to go international,standardized testing technology support for achieving full process quality control,and better meet the needs of drug research and development,production,quality control,and supervision in China.
6.Scaffold and SAR studies on c-MET inhibitors using machine learning approaches
Jing ZHANG ; Mingming ZHANG ; Weiran HUANG ; Changjie LIANG ; Wei XU ; Jing ZHANGHUA ; Jun TU ; Okohi-Agida INNOCENT ; Jinke CHENG ; Dong-Qing WEI ; Buyong MA ; Yanjing WANG ; Hongsheng TAN
Journal of Pharmaceutical Analysis 2025;15(6):1321-1333
Numerous c-mesenchymal-epithelial transition(c-MET)inhibitors have been reported as potential anticancer agents.However,most fail to enter clinical trials owing to poor efficacy or drug resistance.To date,the scaffold-based chemical space of small-molecule c-MET inhibitors has not been analyzed.In this study,we constructed the largest c-MET dataset,which included 2,278 molecules with different struc-tures,by inhibiting the half maximal inhibitory concentration(IC50)of kinase activity.No significant differences in drug-like properties were observed between active molecules(1,228)and inactive mol-ecules(1,050),including chemical space coverage,physicochemical properties,and absorption,distri-bution,metabolism,excretion,and toxicity(ADMET)profiles.The higher chemical diversity of the active molecules was downscaled using t-distributed stochastic neighbor embedding(t-SNE)high-dimensional data.Further clustering and chemical space networks(CSNs)analyses revealed commonly used scaffolds for c-MET inhibitors,such as M5,M7,and M8.Activity cliffs and structural alerts were used to reveal"dead ends"and"safe bets"for c-MET,as well as dominant structural fragments consisting of pyr-idazinones,triazoles,and pyrazines.Finally,the decision tree model precisely indicated the key structural features required to constitute active c-MET inhibitor molecules,including at least three aromatic het-erocycles,five aromatic nitrogen atoms,and eight nitrogen-oxygen atoms.Overall,our analyses revealed potential structure-activity relationship(SAR)patterns for c-MET inhibitors,which can inform the screening of new compounds and guide future optimization efforts.
7.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
8.The value of total volume response and total mass response in the therapeutic evaluation of lung metastasis of hepatocarcinoma
Jun-cheng WAN ; Cai-hong YU ; Chang-yu LI ; Yong-jie ZHOU ; Wei ZHANG ; Jian-hua WANG ; Zhi-ping YAN ; Guo-wei YANG ; Zhuo-yang FAN ; Xu-dong QU
Fudan University Journal of Medical Sciences 2025;52(2):201-208,231
Objective To analyze the correlation between lesion volume,lesion mass,and maximum lesion diameter in the assessment of advanced hepatocarcinoma with lung metastasis,and to evaluate the application value of total volume response and total mass response of lung metastatic lesions in efficacy assessment.Methods A retrospective analysis was conducted on the CT imaging data of 20 patients clinically confirmed with hepatocarcinoma and lung metastases,followed by subsequent follow-up to monitor their survival outcomes.Volume measurement software was used to measure the volume of lesions before and after treatment.We recored lesion diameter,volume measurements and CT values,calculated the mass of the lesions.The correlation between lesion volume,mass and diameter was analyzed,as well as the correlation between the change rates of volume,mass and lesion diameter.Additionally,the total volume and total mass of all lesions were calculated.The correlation between the change rates of total volume/total mass and the change rate of pulmonary lesion diameter under the RECIST 1.1 criteria,as well as the correlation with changes in patients'tumor markers,were analyzed.Furthermore,the overall volume response and overall mass response of lesions were evaluated based on changes in total volume and total mass,and their consistencies with the RECIST 1.1 criteria for efficacy evaluation were analyzed.Finally,univariate Cox regression analysis was performed to explore the association between these variables and patient survival outcomes.Results There was strong correlation between lesion volume,mass and tumor diameter(r=0.771,0.775),between the rate of change in mass and the rate of change in lesion diameter(r=0.846),and between the rates of change in total volume/total mass and the rate of change in pulmonary lesion diameter under the RECIST 1.1 criteria(r=0.800,0.896).The correlation between the rates of change in total volume/total mass and patients'tumor markers was not statistically significant.There was moderate correlation between the rate of change in volume and the rate of change in lesion diameter(r=0.692).The evaluation results of total volume response and total mass response for pulmonary lesions in advanced hepatocarcinoma with lung metastasis were generally consistent with the RECIST 1.1 criteria(Kappa=0.486,0.426).Univariate Cox regression analysis revealed that total lesion volume(P=0.047)and total lesion mass(P=0.049)were independent prognostic factors for survival outcomes.Conclusion Lesion volume,mass,and diameter,as well as their respective change rates,were found to be interrelated.Furthermore,total lesion volume and total lesion mass were identified as independent prognostic factors for survival outcomes.The total volume response and total mass response are promising evaluation methods in evaluating the efficacy of lung metastasis of hepatocarcinoma,which are different from the RECIST 1.1 evaluation criteria.
9.Measurement method based on EBT3 film technology for quality control detection of INTRABEAM PRS500 intraoperative radiotherapy equipment
Yi-kun LI ; Wei DING ; Xia-yu HANG ; Jun HU ; Xiang-dong SUN ; Ai-jun XU
Chinese Medical Equipment Journal 2025;46(6):47-53
Objective To propose an EBT3 film technology-based quality control measurement method for the INTRABEAM PRS500 intraoperative radiotherapy equipment to solve the problems of the traditional methods in cumbersome operation and setup error.Methods According to HJ 1198-2021 Requirements of radiation safety and protection for radiotherapy and GBZ 121-2020 Requirements for radiological protection in radiotherapy,the environmental radiation testing of the INTRABEAM PRS500 intraoperative radiotherapy equipment was carried out point by point by means of the radiation inspection instrument.The INTRABEAM PRS500 intraoperative radiotherapy equipment was characterized by a point X-ray source(XRS),and the XRS was detected in terms of the probe linearity,radiation dose,dynamic deviation,isotropy and dose rate.The EBT3 film technology was used to verify the symmetry and isotropy of the XRS planar dose of INTRABEAM PRS500 intraoperative radiotherapy equipment.Results The X-γ dose equivalent rate of each monitoring site of the INTRABEAM PRS500 intraoperative radiotherapy device was lower than the method detection limit(MDL).The results of SQA quality control showed that the INTRABEAM PRS500 intraoperative radiotherapy equipment XRS met the quality control requirements in terms of the probe linearity,radiation dose,dynamic deviation and etc,and the isotropy differences in the+X,-X,+Y,and-Y axis directions ranged from-1.40%to 1.79%,which were all within the allowable range of measurement tolerance(5.60%to 5.65%).The results of measuring the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment based on the EBT3 film technology showed that the dose distribution of the XRS in the directions of the+X,-X,+Y,and-Y axes at the same plane was well isotropic,and that the doses in the directions of the X and Y axes were symmetrically distributed,and that the maximum skewness value for the isotropy of the XRS in the XY plane was-1.581%,which met the requirements of AAPM TG61 report on the reference dosimetry of low-energy and medium-energy X-rays for radiotherapy and radiobiology of≤±5.3%.Conclusion The EBT3 film technology-based measurement method gains high simplicity and feasibility for the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment in the directions of the+X,-X,+Y,and-Y axes at the same planet,which realizes the dynamic monitoring of the dosimetric changes and facilitates the whole-process quality control management of the intraoperative radiotherapy equipment.[Chinese Medical Equipment Journal,2025,46(6):47-53]
10.Research on coagulation effect of cold atmospheric plasma jet device and its mechanism of action
Yan LI ; Hong-ye ZHENG ; Ao-xi XU ; Ya-jun ZHAO ; Shan-shan JIN ; Xu ZHANG ; Yu-fan WEI ; Yi-heng ZHANG ; Li ZHU ; Xi-ru LI
Chinese Medical Equipment Journal 2025;46(6):20-27
Objective To investigate the coagulation effect of a cold atmospheric plasma(CAP)jet device with helium as the working gas and to study its coagulation mechanism preliminarily.Methods A CAP jet device treatment group,a helium airflow treatment group,a hot air treatment group(60℃)and a natural coagulation group were formed according to the treatment modes of the blood samples,with 10 μL of blood samples involved in each group,in order to validate the coagulation effect of the CAP jet device in vitro;the coagulation mechanism of the CAP jet device was explored by its application to the treatment of anticoagulated whole blood,platelet-rich plasma and platelet-depleted plasma;the coagulation effect of the CAP jet device in vivo was verified with a mouse liver punctate hemorrhage model and a rabbit mesenteric hemorrhage model.Results The CAP jet device can significantly accelerate the coagulation of anticoagulated blood droplets,and the coagulation time of anticoagulated blood droplets in the CAP jet device-treated group was shortened from 28 min in the natural coagulation group to(23±1.56)s,with the difference statistically significant(P<0.05),and the CAP jet device treatment group gained advantages significantly over the helium airflow treatment group(P<0.05)and the hot air(60℃)treatment group(P<0.05)in coagulation-promoting effect;the procoagulant effect of the CAP jet device rose with the increase of platelet content in blood droplets,and the coagulation effect of platelet-rich blood droplets was significantly better than that of whole blood(P<0.05),while no coagulation was observed in platelet-poor droplets.The CAP jet device could rapidly stop hemostasis of punctate hemorrhage in mouse liver and mesenteric hemorrhage in rabbits without delayed hemorrhage occurring within 10 min,and no obvious structural abnormality of the liver and thermal damage of the tissue were found microscopically.Conclusion The CAP jet device plays procoagulant and hemostatic effects in vivo and in vitro,and its effect is not dependent on temperature and airflow evaporation effects and is considered to be related to platelet activation,with low thermal damage to living tissue.[Chinese Medical Equipment Journal,2025,46(6):20-27]

Result Analysis
Print
Save
E-mail