1.A Method for Position Correction of Ultrasonic Arrays Used in High-resolution Photoacoustic Tomography
Yang TANG ; Zhan-Jun ZHANG ; Xing HUANG ; Kuan PENG
Progress in Biochemistry and Biophysics 2026;53(3):767-778
ObjectivePhotoacoustic tomography (PAT) holds significant potential for high-resolution deep-tissue imaging. In preclinical research, custom-designed concave arc-shaped ultrasound transducer arrays are often used to maximize the detection aperture. However, manufacturing limitations and assembly tolerances frequently cause the actual physical positions of array elements to deviate from their theoretical design. Additionally, concave arrays are typically covered with an acoustic lens, which introduces a mismatch in the speed of sound between the coupling medium and the lens material. The combination of these geometric and acoustic-phase errors leads to severe image artifacts, reduced contrast, and degraded resolution. This study proposes a systematic two-step calibration strategy to address these issues and substantially improve image quality. MethodsFirst, a high-intensity isotropic photoacoustic point source was constructed using a multi-mode optical fiber coated with carbon nanotubes (CNTs) to acquire high signal-to-noise ratio calibration data. The Akaike information criterion (AIC) was employed to accurately determine the time of arrival (ToA) of photoacoustic signals. Subsequently, a geometric calibration algorithm based on nonlinear least-squares (NLS) estimation was developed. This algorithm iteratively solves for the true spatial coordinates of each array element by minimizing the residual between theoretical and measured acoustic path lengths. To further address sound-speed inhomogeneity caused by the acoustic lens, a phase compensation algorithm based on bilinear interpolation was proposed. This algorithm computes a pixel-specific phase delay map across the imaging region and performs point-by-point signal correction during delay-and-sum (DAS) reconstruction. The proposed methods were validated using a custom 96-channel concave arc-shaped array (center frequency: 12 MHz) through both phantom imaging and in vivo mouse tumor models. ResultsPhantom experiments showed that at an imaging depth of14 mm, the reconstruction position deviation of the point source in the uncalibrated system reached up to 1 mm. After applying the combined calibration, the lateral resolution (full width at half maximum, FWHM) at the focal point of the arc array reached 95 μm—representing a 85% reduction compared to the uncalibrated state and a 79% reduction compared to geometric calibration alone without phase compensation. In vivo experiments demonstrated that the calibrated system clearly resolved the microvascular network of subcutaneous tumors in mice. Photoacoustic signals were strictly confined within tumor boundaries delineated by ultrasound imaging (USI), eliminating the vascular spillover artifacts commonly observed in uncalibrated images. Furthermore, after intravenous injection of indocyanine green (ICG), the system successfully detected weak photoacoustic signals at a depth of 5 mm, performing significantly better than the uncalibrated system. ConclusionThe proposed calibration method, which integrates nonlinear least-squares estimation with phase compensation, significantly improves image fidelity and spatial resolution consistency across a wide field of view by correcting systemic geometric errors and acoustic phase aberrations. This approach demonstrates high robustness and provides a reliable technical foundation for the clinical translation of photoacoustic probes with non-standard geometries.
2.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
3.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
4.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
5.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
6.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
7.A preclinical evaluation and first-in-man case for transcatheter edge-to-edge mitral valve repair using PulveClip® transcatheter repair device.
Gang-Jun ZONG ; Jie-Wen DENG ; Ke-Yu CHEN ; Hua WANG ; Fei-Fei DONG ; Xing-Hua SHAN ; Jia-Feng WANG ; Ni ZHU ; Fei LUO ; Peng-Fei DAI ; Zhi-Fu GUO ; Yong-Wen QIN ; Yuan BAI
Journal of Geriatric Cardiology 2025;22(2):265-269
8.Correlation analysis between MRI texture features and gene mutations in renal cell carcinoma based on radiogenomics
Liang PAN ; Zhaoyu XING ; Jun SUN ; Jiule DING ; Yan PENG ; Jie CHEN ; Wei XING
Chinese Journal of Radiology 2025;59(1):84-90
Objective:To investigate the associations between MRI texture features and genetic mutations in clear cell renal cell carcinoma (ccRCC) and non-ccRCC (n-ccRCC).Methods:This was a cross-section study. A retrospective review was performed on 31 patients (ccRCC group 19 cases and n-ccRCC group 12 cases) diagnosed with renal cell carcinomas and underwent targeted sequencing between April 2011 and December 2021 in the Third Affiliated Hospital of Soochow University. All the patients underwent MRI examinations within two weeks before partial or radical nephrectomy. Texture features were extracted from T 1WI, T 2WI, Dixon-MRI, cortical-medulla phase (CMP), nephrographic phase (NGP), and delayed phase (DEP) images. MRI texture features with the highest value for distinguishing ccRCC from n-ccRCC were selected for subsequent analysis. The next-generation high-throughput sequencing technology was employed to analyze gene mutations in renal tumors. The correlation between mutation genes and texture features in ccRCC and n-ccRCC was analyzed using Spearman correlation coefficient. Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway annotation analysis was performed. Results:A total of 8 MRI texture features were selected. In the ccRCC group, PTEN mutation was correlated with DEP_InverseDifferenceMoment_angle0_offset7 ( r=-0.58, P=0.009). In the non-ccRCC group, SETD2 mutation was correlated with CM_Phase_InverseDifferenceMoment_AllDirection_offset1 and Dixon_W_InverseDifferenceMoment_AllDirection_offset7 ( r=0.58, 0.63, P=0.048, 0.027), PBRM1 mutation was correlated with DE_Phase_InverseDifferenceMoment_angle0_offset7 and DE_Phase_HaraVariance ( r=0.61, -0.60, P=0.034, 0.039), and FAT1 mutation was correlated with DE_Phase_HaraVariance and NG_Phase_Inertia_angle135_offset4 ( r=0.58, 0.58, P=0.047, 0.047). The KEGG pathway annotation analysis showed that the mechanisms of the mutation genes that correlated with MRI texture features in the ccRCC group were related to the p53 signaling pathway, inositol phosphate metabolism, central carbon metabolism in cancer, EGFR tyrosine kinase inhibitor resistance, PD-L1 expression and PD-1 checkpoint pathway in cancer, and phosphatidylinositol signaling system. The mutation genes correlated with MRI texture features in the non-ccRCC group were mainly associated with lysine degradation. Conclusion:The associations are found between MRI texture features and underlying genetic mutations of ccRCC and n-ccRCC. These mutation genes have completely different enrichment pathways.
9.Investigation of the Mechanism of Cold Hyperalgesia in KOA Mice Relieved by Shangke Lengtongtie Based on HMGB1/CX-CL12/CXCR4 Signaling Axis
Yibao WEI ; Li ZHANG ; Taiyang LIAO ; Lishi JIE ; Zhenyuan MA ; Peng WU ; Zhengquan HUANG ; Li ZHANG ; Liang DING ; Wei MEI ; Runlin XING ; Songjiang YIN ; Xiaochen LI ; Nongshan ZHANG ; Jun MAO ; Pei-min WANG
Journal of Nanjing University of Traditional Chinese Medicine 2025;41(2):195-202
OBJECTIVE To explore the intervention mechanism of Shangke Lengtongtie on cold hyperalgesia in KOA mice based on the HMGB1/CXCL12/CXCR4 signaling axis.METHODS Monosodium iodoacetate(MIA)was used for the intra-articular injec-tion into the knee joint to establish mice model of knee osteoarthritis(KOA).Peripheral blood monocytes were extracted from mice,cultured,and then reinfused into the tail vein of the mice.Subsequently,in vivo animal imaging was used to observe the recruitment sites of these monocytes.The cold hyperalgesia threshold was measured at various time points in each group of mice.Hematoxylin and eosin(HE)staining was used to evaluate the level of synovial pathological changes.ELISA was employed to detect the expression of in-flammatory factors IL-1β,TNF-α,and pain mediators CGRP and Substance P in mouse serum.Western blot and qPCR methods were used to detect the protein and gene expression of cold hyperalgesia-related indicators such as TRPA1,TRPM8,HMGB1,CXCL12,CXCR4,Collagen Ⅰ,and Netrin-1 in synovial tissue,as well as DCC in dorsal root ganglia(DRG)tissue.RESULTS In vivo ima-ging showed that after the monocytes were reinfused into KOA mice,they were recruited to the knee joint area,with the HMGB1 group exhibiting a greater recruitment of circulating monocytes at the knee joint.Additionally,compared to the control group,the KOA group and HMGB1 group showed inflammatory pathological changes in the synovium,increased expression of serum inflammatory factors and pain mediators,reduced cold hyperalgesia threshold,and upregulated protein and gene expression of cold hyperalgesia-related indica-tors in synovial and DRG tissues.The changes were more significant in the HMGB1 group compared to the KOA group(P<0.05).Af-ter treatment with Shangke Lengtongtie or GL intervention,synovial inflammation was alleviated,serum inflammatory factors and pain mediators decreased,cold hyperalgesia threshold increased,and the upregulation of cold hyperalgesia-related indicator protein and gene expression levels was significantly reversed(P<0.05).CONCLUSION Shangke Lengtongtie exerts a beneficial effect on the mitigation of synovitis and cold hyperalgesia in KOA mice,a therapeutic mechanism that possibly mediated through the inhibition of the HMGB1/CXCL12/CXCR4 signaling axis.
10.A Randomized Controlled Clinical Study on the Treatment of Knee Osteoarthritis with Cold-Dampness Arthralgia Obstruc-tion by Shangke Lengtong Patch
Li ZHANG ; Liang DING ; Zhengquan HUANG ; Wei MEI ; Runlin XING ; Songjiang YIN ; Peng WU ; Xi-aochen LI ; Zhenyuan MA ; Nongshan ZHANG ; Jun MAO ; Peimin WANG
Journal of Nanjing University of Traditional Chinese Medicine 2025;41(3):393-398
OBJECTIVE To explore the effectiveness and possible mechanism of Shangke Lengtong Patch in treating knee osteo-arthritis with cold-dampness arthralgia obstruction.METHODS A total of 70 patients who met the inclusion criteria of knee osteoar-thritis with cold-dampness arthralgia obstruction in the Orthopedics Department of Affiliated Hospital of Nanjing University of Chinese Medicine from November to December 2024 were randomly divided into an experimental group and a control group,with 35 cases in each group.During the treatment,1 case dropped out of the experimental group,3 cases dropped out of the control group,and 1 case was discontinued.The experimental group was treated with Shangke Lengtong Patch,and the control group was treated with Compound Nanxing Zhitong Ointment.The WOMAC scores and TCM syndrome scores of the two groups before and after treatment were compared to comprehensively evaluate the clinical efficacy.The changes in the expression levels of CGRP,substance P,HMGB1,IL-1β,CX-CL12,and CXCR4 in the serum of the two groups were detected by ELISA.RESULTS After 3,7,and 14 d of treatment,the WOMAC scores and TCM syndrome scores of the two groups were significantly reduced(P<0.05,P<0.01),and the score of aggrava-ted cold in the experimental group was better than that in the control group at 7 d of treatment(P<0.05);after 14 d of treatment,the expression levels of CGRP,substance P,HMGB1,IL-1β,CXCL12,and CXCR4 in the serum of the two groups were significantly re-duced(P<0.05),and there was no statistical difference between the two groups.CONCLUSION Shangke Lengtong Patch can sig-nificantly relieve the pain symptoms of knee osteoarthritis patients with cold-dampness arthralgia obstruction and improve the joint func-tion of patients.It may improve synovial inflammation by inhibiting the HMGB1/CXCL12/CXCR4 pathway,thereby exerting a thera-peutic effect.

Result Analysis
Print
Save