1.A Method for Position Correction of Ultrasonic Arrays Used in High-resolution Photoacoustic Tomography
Yang TANG ; Zhan-Jun ZHANG ; Xing HUANG ; Kuan PENG
Progress in Biochemistry and Biophysics 2026;53(3):767-778
ObjectivePhotoacoustic tomography (PAT) holds significant potential for high-resolution deep-tissue imaging. In preclinical research, custom-designed concave arc-shaped ultrasound transducer arrays are often used to maximize the detection aperture. However, manufacturing limitations and assembly tolerances frequently cause the actual physical positions of array elements to deviate from their theoretical design. Additionally, concave arrays are typically covered with an acoustic lens, which introduces a mismatch in the speed of sound between the coupling medium and the lens material. The combination of these geometric and acoustic-phase errors leads to severe image artifacts, reduced contrast, and degraded resolution. This study proposes a systematic two-step calibration strategy to address these issues and substantially improve image quality. MethodsFirst, a high-intensity isotropic photoacoustic point source was constructed using a multi-mode optical fiber coated with carbon nanotubes (CNTs) to acquire high signal-to-noise ratio calibration data. The Akaike information criterion (AIC) was employed to accurately determine the time of arrival (ToA) of photoacoustic signals. Subsequently, a geometric calibration algorithm based on nonlinear least-squares (NLS) estimation was developed. This algorithm iteratively solves for the true spatial coordinates of each array element by minimizing the residual between theoretical and measured acoustic path lengths. To further address sound-speed inhomogeneity caused by the acoustic lens, a phase compensation algorithm based on bilinear interpolation was proposed. This algorithm computes a pixel-specific phase delay map across the imaging region and performs point-by-point signal correction during delay-and-sum (DAS) reconstruction. The proposed methods were validated using a custom 96-channel concave arc-shaped array (center frequency: 12 MHz) through both phantom imaging and in vivo mouse tumor models. ResultsPhantom experiments showed that at an imaging depth of14 mm, the reconstruction position deviation of the point source in the uncalibrated system reached up to 1 mm. After applying the combined calibration, the lateral resolution (full width at half maximum, FWHM) at the focal point of the arc array reached 95 μm—representing a 85% reduction compared to the uncalibrated state and a 79% reduction compared to geometric calibration alone without phase compensation. In vivo experiments demonstrated that the calibrated system clearly resolved the microvascular network of subcutaneous tumors in mice. Photoacoustic signals were strictly confined within tumor boundaries delineated by ultrasound imaging (USI), eliminating the vascular spillover artifacts commonly observed in uncalibrated images. Furthermore, after intravenous injection of indocyanine green (ICG), the system successfully detected weak photoacoustic signals at a depth of 5 mm, performing significantly better than the uncalibrated system. ConclusionThe proposed calibration method, which integrates nonlinear least-squares estimation with phase compensation, significantly improves image fidelity and spatial resolution consistency across a wide field of view by correcting systemic geometric errors and acoustic phase aberrations. This approach demonstrates high robustness and provides a reliable technical foundation for the clinical translation of photoacoustic probes with non-standard geometries.
2.A preclinical evaluation and first-in-man case for transcatheter edge-to-edge mitral valve repair using PulveClip® transcatheter repair device.
Gang-Jun ZONG ; Jie-Wen DENG ; Ke-Yu CHEN ; Hua WANG ; Fei-Fei DONG ; Xing-Hua SHAN ; Jia-Feng WANG ; Ni ZHU ; Fei LUO ; Peng-Fei DAI ; Zhi-Fu GUO ; Yong-Wen QIN ; Yuan BAI
Journal of Geriatric Cardiology 2025;22(2):265-269
3.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
4.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
5.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
6.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
7.Guideline for Adult Weight Management in China
Weiqing WANG ; Qin WAN ; Jianhua MA ; Guang WANG ; Yufan WANG ; Guixia WANG ; Yongquan SHI ; Tingjun YE ; Xiaoguang SHI ; Jian KUANG ; Bo FENG ; Xiuyan FENG ; Guang NING ; Yiming MU ; Hongyu KUANG ; Xiaoping XING ; Chunli PIAO ; Xingbo CHENG ; Zhifeng CHENG ; Yufang BI ; Yan BI ; Wenshan LYU ; Dalong ZHU ; Cuiyan ZHU ; Wei ZHU ; Fei HUA ; Fei XIANG ; Shuang YAN ; Zilin SUN ; Yadong SUN ; Liqin SUN ; Luying SUN ; Li YAN ; Yanbing LI ; Hong LI ; Shu LI ; Ling LI ; Yiming LI ; Chenzhong LI ; Hua YANG ; Jinkui YANG ; Ling YANG ; Ying YANG ; Tao YANG ; Xiao YANG ; Xinhua XIAO ; Dan WU ; Jinsong KUANG ; Lanjie HE ; Wei GU ; Jie SHEN ; Yongfeng SONG ; Qiao ZHANG ; Hong ZHANG ; Yuwei ZHANG ; Junqing ZHANG ; Xianfeng ZHANG ; Miao ZHANG ; Yifei ZHANG ; Yingli LU ; Hong CHEN ; Li CHEN ; Bing CHEN ; Shihong CHEN ; Guiyan CHEN ; Haibing CHEN ; Lei CHEN ; Yanyan CHEN ; Genben CHEN ; Yikun ZHOU ; Xianghai ZHOU ; Qiang ZHOU ; Jiaqiang ZHOU ; Hongting ZHENG ; Zhongyan SHAN ; Jiajun ZHAO ; Dong ZHAO ; Ji HU ; Jiang HU ; Xinguo HOU ; Bimin SHI ; Tianpei HONG ; Mingxia YUAN ; Weibo XIA ; Xuejiang GU ; Yong XU ; Shuguang PANG ; Tianshu GAO ; Zuhua GAO ; Xiaohui GUO ; Hongyi CAO ; Mingfeng CAO ; Xiaopei CAO ; Jing MA ; Bin LU ; Zhen LIANG ; Jun LIANG ; Min LONG ; Yongde PENG ; Jin LU ; Hongyun LU ; Yan LU ; Chunping ZENG ; Binhong WEN ; Xueyong LOU ; Qingbo GUAN ; Lin LIAO ; Xin LIAO ; Ping XIONG ; Yaoming XUE
Chinese Journal of Endocrinology and Metabolism 2025;41(11):891-907
Body weight abnormalities, including overweight, obesity, and underweight, have become a dual public health challenge in Chinese adults: overweight and obesity lead to a variety of chronic complications, while underweight increases the risks of malnutrition, sarcopenia, and organ dysfunction. To systematically address these issues, multidisciplinary experts in endocrinology, sports science, nutrition, and psychiatry from various regions have held multiple weight management seminars. Based on the latest epidemiological data and clinical evidence, they expanded the guideline to include assessment and intervention strategies for underweight, in addition to the core content of obesity management. This guideline outlines the etiological mechanisms, evaluation methods, and multidimensional management strategies for overweight and obesity, covering key areas such as diagnosis and assessment, medical nutrition therapy, exercise prescription, pharmacological intervention, and psychological support. It is intended to provide a scientific and standardized approach to weight management across the adult population, aiming to curb the rising prevalence of obesity, mitigate complications associated with abnormal body weight, and improve nutritional status and overall quality of life.
8.Correlation analysis between MRI texture features and gene mutations in renal cell carcinoma based on radiogenomics
Liang PAN ; Zhaoyu XING ; Jun SUN ; Jiule DING ; Yan PENG ; Jie CHEN ; Wei XING
Chinese Journal of Radiology 2025;59(1):84-90
Objective:To investigate the associations between MRI texture features and genetic mutations in clear cell renal cell carcinoma (ccRCC) and non-ccRCC (n-ccRCC).Methods:This was a cross-section study. A retrospective review was performed on 31 patients (ccRCC group 19 cases and n-ccRCC group 12 cases) diagnosed with renal cell carcinomas and underwent targeted sequencing between April 2011 and December 2021 in the Third Affiliated Hospital of Soochow University. All the patients underwent MRI examinations within two weeks before partial or radical nephrectomy. Texture features were extracted from T 1WI, T 2WI, Dixon-MRI, cortical-medulla phase (CMP), nephrographic phase (NGP), and delayed phase (DEP) images. MRI texture features with the highest value for distinguishing ccRCC from n-ccRCC were selected for subsequent analysis. The next-generation high-throughput sequencing technology was employed to analyze gene mutations in renal tumors. The correlation between mutation genes and texture features in ccRCC and n-ccRCC was analyzed using Spearman correlation coefficient. Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway annotation analysis was performed. Results:A total of 8 MRI texture features were selected. In the ccRCC group, PTEN mutation was correlated with DEP_InverseDifferenceMoment_angle0_offset7 ( r=-0.58, P=0.009). In the non-ccRCC group, SETD2 mutation was correlated with CM_Phase_InverseDifferenceMoment_AllDirection_offset1 and Dixon_W_InverseDifferenceMoment_AllDirection_offset7 ( r=0.58, 0.63, P=0.048, 0.027), PBRM1 mutation was correlated with DE_Phase_InverseDifferenceMoment_angle0_offset7 and DE_Phase_HaraVariance ( r=0.61, -0.60, P=0.034, 0.039), and FAT1 mutation was correlated with DE_Phase_HaraVariance and NG_Phase_Inertia_angle135_offset4 ( r=0.58, 0.58, P=0.047, 0.047). The KEGG pathway annotation analysis showed that the mechanisms of the mutation genes that correlated with MRI texture features in the ccRCC group were related to the p53 signaling pathway, inositol phosphate metabolism, central carbon metabolism in cancer, EGFR tyrosine kinase inhibitor resistance, PD-L1 expression and PD-1 checkpoint pathway in cancer, and phosphatidylinositol signaling system. The mutation genes correlated with MRI texture features in the non-ccRCC group were mainly associated with lysine degradation. Conclusion:The associations are found between MRI texture features and underlying genetic mutations of ccRCC and n-ccRCC. These mutation genes have completely different enrichment pathways.
9.Integrated Optical and Magnetic Navigation for Simplified Percutaneous Transforaminal Endoscopic Lumbar Discectomy: A Novel Approach
Xing-Chen YAO ; Jun-Peng LIU ; Xin-Ru DU ; Li GUAN ; Yong HAI ; Jincai YANG ; Aixing PAN
Neurospine 2025;22(1):297-307
Objective:
This study aims to evaluate the clinical benefits of the integrated optical and magnetic surgical navigation system in assisting transforaminal endoscopic lumbar discectomy (TELD) for the treatment of lumbar disc herniation (LDH).
Methods:
A retrospective analysis was conducted on patients who underwent TELD for LDH at Beijing Chaoyang Hospital, Capital Medical University from November 2022 to December 2023. Patients treated with the integrated optical and magnetic surgical navigation system were defined as the navigation-guided TELD (Ng-TELD) group (30 cases), while those treated with the conventional x-ray fluoroscopy method were defined as the control group (31 cases). Record and compare baseline characteristics, surgical parameters, efficacy indicators, and adverse events between the 2 patient groups.
Results:
The average follow-up duration for the 61 patients was 11.8 months. Postoperatively, both groups exhibited significant relief from back and leg pain, which continued to improve over time. At the final follow-up, patients’ lumbar function and quality of life had significantly improved compared to preoperative levels (p < 0.05). The Ng-TELD group had significantly shorter total operation time (58.43 ± 12.37 minutes vs. 83.23 ± 25.90 minutes), catheter placement time (5.83 ± 1.09 minutes vs. 15.94 ± 3.00 minutes), decompression time (47.17 ± 11.98 minutes vs. 67.29 ± 24.23 minutes), and fewer intraoperative fluoroscopies (3.20 ± 1.45 vs. 16.58 ± 4.25) compared to the control group (p < 0.05). There were no significant differences between the groups in terms of efficacy evaluation indicators and hospital stay. At the final follow-up, the excellent and good rate of surgical outcomes assessed by the MacNab criteria was 98.4%, and the overall adverse event rate was 8.2%, with no statistically significant differences between the groups (p > 0.05).
Conclusion
This study demonstrates that the integrated optical and magnetic surgical navigation system can reduce the complexity of TELD, shorten operation time, and minimize radiation exposure for the surgeon, highlighting its promising clinical potential.
10.CURRENT DISTRIBUTION OF AEDES AEGYPTI IN LEIZHOU PENINSULA,ZHANJIANG CITY,GUANGDONG PROVINCE
Rui-Peng LU ; Jin-Hua DUAN ; Yu-Wen ZHONG ; Hui DENG ; Jun WU ; Li-Ping LIU ; Wei-Xiong YIN ; Feng XING ; Hui HUANG ; Chang-Jie FU ; Zong-Jing CHEN ; Ming-Ji CHENG ; Sheng-Jun HU ; Ya-Ting CHEN ; Wen-Ting GUO ; Li-Feng LIN
Acta Parasitologica et Medica Entomologica Sinica 2025;32(1):16-21
Objective To investigate the status of population dynamics and distribution changes of Aedes aegypti in Guangdong Province.Methods Continuous monitoring was conducted from May 2018 to July 2024 in Wushi Town and Qishui Town,Leizhou City,Zhanjiang City,Guangdong Province.Additionally,a survey of the distribution of Ae.aegypti along the Leizhou Peninsula coast was carried out.Results The density of Ae.aegypti in Zhanjiang showed a gradual decline from 2018 to 2024.The last detection of adult Ae.aegypti in Wushi Town was in September 2021,and the last larva was found in October 2023.No Ae.aegypti was detected in Qishui Town during surveys from 2021 to 2024.A survey of 18 coastal villages in the Leizhou Peninsula revealed no detections of Ae.aegypti.Conclusions This study provides a basis for understanding the distribution and population density fluctuations of Ae.aegypti,assessing its invasion risk,and scientifically conducting relevant prevention and control efforts.

Result Analysis
Print
Save
E-mail