1.Severity Assessment Parameters and Diagnostic Technologies of Obstructive Sleep Apnea
Zhuo-Zhi FU ; Ya-Cen WU ; Mei-Xi LI ; Ping-Ping YIN ; Hai-Jun LIN ; Fu ZHANG ; Yu-Xiang YANG
Progress in Biochemistry and Biophysics 2025;52(1):147-161
Obstructive sleep apnea (OSA) is an increasingly widespread sleep-breathing disordered disease, and is an independent risk factor for many high-risk chronic diseases such as hypertension, coronary heart disease, stroke, arrhythmias and diabetes, which is potentially fatal. The key to the prevention and treatment of OSA is early diagnosis and treatment, so the assessment and diagnostic technologies of OSA have become a research hotspot. This paper reviews the research progresses of severity assessment parameters and diagnostic technologies of OSA, and discusses their future development trends. In terms of severity assessment parameters of OSA, apnea hypopnea index (AHI), as the gold standard, together with the percentage of duration of apnea hypopnea (AH%), lowest oxygen saturation (LSpO2), heart rate variability (HRV), oxygen desaturation index (ODI) and the emerging biomarkers, constitute a multi-dimensional evaluation system. Specifically, the AHI, which measures the frequency of sleep respiratory events per hour, does not fully reflect the patients’ overall sleep quality or the extent of their daytime functional impairments. To address this limitation, the AH%, which measures the proportion of the entire sleep cycle affected by apneas and hypopneas, deepens our understanding of the impact on sleep quality. The LSpO2 plays a critical role in highlighting the potential severe hypoxic episodes during sleep, while the HRV offers a different perspective by analyzing the fluctuations in heart rate thereby revealing the activity of the autonomic nervous system. The ODI provides a direct and objective measure of patients’ nocturnal oxygenation stability by calculating the number of desaturation events per hour, and the biomarkers offers novel insights into the diagnosis and management of OSA, and fosters the development of more precise and tailored OSA therapeutic strategies. In terms of diagnostic techniques of OSA, the standardized questionnaire and Epworth sleepiness scale (ESS) is a simple and effective method for preliminary screening of OSA, and the polysomnography (PSG) which is based on recording multiple physiological signals stands for gold standard, but it has limitations of complex operations, high costs and inconvenience. As a convenient alternative, the home sleep apnea testing (HSAT) allows patients to monitor their sleep with simplified equipment in the comfort of their own homes, and the cardiopulmonary coupling (CPC) offers a minimal version that simply analyzes the electrocardiogram (ECG) signals. As an emerging diagnostic technology of OSA, machine learning (ML) and artificial intelligence (AI) adeptly pinpoint respiratory incidents and expose delicate physiological changes, thus casting new light on the diagnostic approach to OSA. In addition, imaging examination utilizes detailed visual representations of the airway’s structure and assists in recognizing structural abnormalities that may result in obstructed airways, while sound monitoring technology records and analyzes snoring and breathing sounds to detect the condition subtly, and thus further expands our medical diagnostic toolkit. As for the future development directions, it can be predicted that interdisciplinary integrated researches, the construction of personalized diagnosis and treatment models, and the popularization of high-tech in clinical applications will become the development trends in the field of OSA evaluation and diagnosis.
2.Prediction of lymph node metastasis in invasive lung adenocarcinoma based on radiomics of the primary lesion, peritumoral region, and tumor habitat: A single-center retrospective study
Hongchang WANG ; Yan GU ; Wenhao ZHANG ; Guang MU ; Wentao XUE ; Mengen WANG ; Chenghao FU ; Liang CHEN ; Mei YUAN ; Jun WANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(08):1079-1085
Objective To predict the lymph node metastasis status of patients with invasive pulmonary adenocarcinoma by constructing machine learning models based on primary tumor radiomics, peritumoral radiomics, and habitat radiomics, and to evaluate the predictive performance and generalization ability of different imaging features. Methods A retrospective analysis was performed on the clinical data of 1 263 patients with invasive pulmonary adenocarcinoma who underwent surgery at the Department of Thoracic Surgery, Jiangsu Province Hospital, from 2016 to 2019. Habitat regions were delineated by applying K-means clustering (average cluster number of 2) to the grayscale values of CT images. The peritumoral region was defined as a uniformly expanded area of 3 mm around the primary tumor. The primary tumor region was automatically segmented using V-net combined with manual correction and annotation. Subsequently, radiomics features were extracted based on these regions, and stacked machine learning models were constructed. Model performance was evaluated on the training, testing, and internal validation sets using the area under the receiver operating characteristic curve (AUC), F1 score, recall, and precision. Results After excluding patients who did not meet the screening criteria, a total of 651 patients were included. The training set consisted of 468 patients (181 males, 287 females) with an average age of (58.39±11.23) years, ranging from 29 to 78 years, the testing set included 140 patients (56 males, 84 females) with an average age of (58.81±10.70) years, ranging from 34 to 82 years, and the internal validation set comprised 43 patients (14 males, 29 females) with an average age of (60.16±10.68) years, ranging from 29 to 78 years. Although the habitat radiomics model did not show the optimal performance in the training set, it exhibited superior performance in the internal validation set, with an AUC of 0.952 [95%CI (0.87, 1.00)], an F1 score of 84.62%, and a precision-recall AUC of 0.892, outperforming the models based on the primary tumor and peritumoral regions. Conclusion The model constructed based on habitat radiomics demonstrated superior performance in the internal validation set, suggesting its potential for better generalization ability and clinical application in predicting lymph node metastasis status in pulmonary adenocarcinoma.
3.Analysis and application thinking of standards for 500 kinds of traditional Chinese medicine formula granules on base of industrial practice.
Yong LIU ; Jun ZHANG ; Xin-Hai DONG ; Lin ZHOU ; Dong-Mei SUN ; Fu-Lin MAO ; Zhen-Yu LI ; Lei HUANG ; Jin-Lai LIU
China Journal of Chinese Materia Medica 2025;50(5):1427-1436
Following the release of the Technical Requirements on Quality Control and Standard Establishment of Traditional Chinese Medicine Formula Granules by the National Medical Products Administration in 2021, Chinese Pharmacopoeia Commission has promulgated 296 national drug standards so far, and most provinces have started the work of establishing provincial standards as supplements. The promulgation of standards fostered high-quality development of the industry. Since the implementation of national and provincial standards for more than three years, enterprises have gained deep understanding and hands-on experiences on the characteristics, technical requirements, production process, and quality control of traditional Chinese medicine(TCM) formula granules. Meanwhile, challenges have emerged restricting the high-quality development of this industry, including how to formulate quality control strategies for medicinal materials and decoction pieces, how to reduce manufacturing costs, and how to improve the pass rate and product stability under high standards. Based on the work experiences from standard management and process research, this article analyzed the distribution of sources, processing methods, dry extract rate ranges, process requirements for volatile oil-containing decoction pieces, control measures of safety indices, characteristics and trends of setting characteristic chromatograms or fingerprints, characteristics and trends of setting content ranges, and main differences between national standards and provincial standards. On the one hand, this article aims to present main characteristics for deeply understanding different indicators in standards and provide basic ideas for establishing quality and process control systems. On the other hand, from the perspective of industrial practice, suggestions are put forward on the important aspects that need to be focused on in the quality and process control of TCM formula granules.
Drugs, Chinese Herbal/chemistry*
;
Quality Control
;
Medicine, Chinese Traditional/standards*
;
China
;
Drug Industry/standards*
4.Chinese guideline for the clinical application of noninvasive imaging technology in accessing cancer therapy-related cardiovascular toxicity.
Mei ZHANG ; Dian-Fu LI ; Jun PU
Journal of Geriatric Cardiology 2025;22(5):477-496
Cardiovascular damage caused by cancer treatment has become an important cause of death for tumor survivors. With the recognition of cardiovascular diseases and cancer therapy-related cardiovascular toxicity (CTR-CVT) in tumor patients, noninvasive imaging technologies play pivotal roles in the risk stratification, early diagnosis, monitoring and follow-up for CTR-CVT. In recent years, the field of cardio-oncology has witnessed continual updates in diagnostic and therapeutic strategies, with several pertinent guidelines and expert consensus documents issued in China and abroad. However, there remains a conspicuous absence of systematic guidance documents on the application of imaging techniques in the clinical practice of cardio-oncology. Therefore, the Chinese Anti-Cancer Association Society of Integrative Cardio-oncology, the Ultrasound Branch of the Chinese Medical Association, and the Chinese Society of Echocardiography convened experts to formulate the "Chinese guideline for the clinical application of noninvasive imaging technology in accessing cancer therapy-related cardiovascular toxicity". Building upon the systematic evaluation of guidelines and the latest evidence-based medical research in the field of cardio-oncology domestically and abroad, and in conjunction with data derived from evidence-based medical research in China, this guideline proposes noninvasive imaging examination methods and monitoring strategies for CTR-CVT, aiming to further standardize and guide the clinical practice of multidisciplinary physicians specializing in cardio-oncology in China.
5.Vascular Protection of Neferine on Attenuating Angiotensin II-Induced Blood Pressure Elevation by Integrated Network Pharmacology Analysis and RNA-Sequencing Approach.
A-Ling SHEN ; Xiu-Li ZHANG ; Zhi GUO ; Mei-Zhu WU ; Ying CHENG ; Da-Wei LIAN ; Chang-Geng FU ; Jun PENG ; Min YU ; Ke-Ji CHEN
Chinese journal of integrative medicine 2025;31(8):694-706
OBJECTIVE:
To explore the functional roles and underlying mechanisms of neferine in the context of angiotensin II (Ang II)-induced hypertension and vascular dysfunction.
METHODS:
Male mice were infused with Ang II to induce hypertension and randomly divided into treatment groups receiving neferine or a control vehicle based on baseline blood pressure using a random number table method. The hypertensive mouse model was constructed by infusing Ang II via a micro-osmotic pump (500 ng/kg per minute), and neferine (0.1, 1, or 10 mg/kg), valsartan (10 mg/kg), or double distilled water was administered intragastrically once daily for 6 weeks. A non-invasive blood pressure system, ultrasound, and hematoxylin and eosin staining were performed to assess blood pressure and vascular changes. RNA sequencing and network pharmacology were employed to identify differentially expressed transcripts (DETs) and pathways. Vascular ring tension assay was used to test vascular function. A7R5 cells were incubated with neferine for 24 h and then treated with Ang II to record the real-time Ca2+ concentration by confocal microscope. Immunohistochemistry (IHC) and Western blot were used to evaluate vasorelaxation, calcium, and the extracellular signal-regulated kinase (ERK)1/2 pathway.
RESULTS:
Neferine treatment effectively mitigated the elevation in blood pressure, pulse wave velocity, aortic thickening in the abdominal aorta of Ang II-infused mice (P<0.05). RNA sequencing and network pharmacology analysis identified 355 DETs that were significantly reversed by neferine treatment, along with 25 potential target genes, which were further enriched in multiple pathways and biological processes, such as ERK1 and ERK2 cascade regulation, calcium pathway, and vascular smooth muscle contraction. Further investigation revealed that neferine treatment enhanced vasorelaxation and reduced Ca2+-dependent contraction of abdominal aortic rings, independent of endothelium function (P<0.05). The underlying mechanisms were mediated, at least in part, via suppression of receptor-operated channels, store-operated channels, or voltage-operated calcium channels. Neferine pre-treatment demonstrated a reduction in intracellular Ca2+ release in Ang II stimulated A7R5 cells. IHC staining and Western blot confirmed that neferine treatment effectively attenuated the upregulation of p-ERK1/2 both in vivo and in vitro, which was similar with treatment of ERK1/2 inhibitor PD98059 (P<0.05).
CONCLUSIONS
Neferine remarkably alleviates Ang II-induced elevation of blood pressure, vascular dysfunction, and pathological changes in the abdominal aorta. This beneficial effect is mediated by the modulation of multiple pathways, including calcium and ERK1/2 pathways.
Animals
;
Angiotensin II
;
Male
;
Benzylisoquinolines/therapeutic use*
;
Network Pharmacology
;
Blood Pressure/drug effects*
;
Sequence Analysis, RNA
;
Mice
;
Hypertension/chemically induced*
;
Mice, Inbred C57BL
;
Calcium/metabolism*
6.Research Progress in the Function and Regulation of Sirtuin 3 in Sepsis-Related Diseases.
Jun-Jie LI ; Hong MEI ; Xin-Xin LIU ; Kun YU ; Bang-Hai FENG ; Bao FU ; Song QIN
Acta Academiae Medicinae Sinicae 2025;47(4):601-610
Sepsis is a life-threatening organ dysfunction caused by a dysregulated host response to infection,with a high mortality rate.Sirtuin 3,a deacetylase within mitochondria,plays an important regulatory role in cellular metabolism,oxidative stress,and inflammatory responses.In recent years,significant progress has been made in the study of the function and regulatory role of sirtuin 3 in sepsis-related diseases.Research has shown that sirtuin 3 can alleviate organ damage caused by sepsis by regulating mitochondrial function,reducing oxidative stress,and inhibiting inflammatory responses.The specific mechanisms include the regulation of mitochondrial bioenergetics,activation of antioxidant enzyme systems,and inhibition of inflammatory mediator expression.In addition,sirtuin 3 plays a protective role in the pathological process of sepsis by interacting with multiple signaling pathways.This article summarizes the functions and regulatory mechanisms of sirtuin 3 in various sepsis-related diseases,aiming to provide new targets and strategies for the prevention and treatment of sepsis in the future.
Sepsis/metabolism*
;
Sirtuin 3/physiology*
;
Humans
;
Animals
;
Oxidative Stress
;
Mitochondria/metabolism*
;
Signal Transduction
7.Development of the robotic digestive endoscope system and an experimental study on mechanistic model and living animals (with video)
Bingrong LIU ; Yili FU ; Kaipeng LIU ; Deliang LI ; Bo PAN ; Dan LIU ; Hao QIU ; Xiaocan JIA ; Jianping CHEN ; Jiyu ZHANG ; Mei WANG ; Fengdong LI ; Xiaopeng ZHANG ; Zongling KAN ; Jinghao LI ; Yuan GAO ; Min SU ; Quanqin XIE ; Jun YANG ; Yu LIU ; Lixia ZHAO
Chinese Journal of Digestive Endoscopy 2024;41(1):35-42
Objective:To develop a robotic digestive endoscope system (RDES) and to evaluate its feasibility, safety and control performance by experiments.Methods:The RDES was designed based on the master-slave control system, which consisted of 3 parts: the integrated endoscope, including a knob and button robotic control system integrated with a gastroscope; the robotic mechanical arm system, including the base and arm, as well as the endoscopic advance-retreat control device (force-feedback function was designed) and the endoscopic axial rotation control device; the control console, including a master manipulator and an image monitor. The operator sit far away from the endoscope and controlled the master manipulator to bend the end of the endoscope and to control advance, retract and rotation of the endoscope. The air supply, water supply, suction, figure fixing and motion scaling switching was realized by pressing buttons on the master manipulator. In the endoscopy experiments performed on live pigs, 5 physicians each were in the beginner and advanced groups. Each operator operated RDES and traditional endoscope (2 weeks interval) to perform porcine gastroscopy 6 times, comparing the examination time. In the experiment of endoscopic circle drawing on the inner wall of the simulated stomach model, each operator in the two groups operated RDES 1∶1 motion scaling, 5∶1 motion scaling and ordinary endoscope to complete endoscopic circle drawing 6 times, comparing the completion time, accuracy (i.e. trajectory deviation) and workload.Results:RDES was operated normally with good force feedback function. All porcine in vivo gastroscopies were successful, without mucosal injury, bleeding or perforation. In beginner and advanced groups, the examination time of both RDES and ordinary endoscopy tended to decrease as the number of operations increased, but the decrease in time was greater for operating RDES than for operating ordinary endoscope (beginner group P=0.033; advanced group P=0.023). In the beginner group, the operators operating RDES with 1∶1 motion scaling or 5∶1 motion scaling to complete endoscopic circle drawing had shorter completion time [1.68 (1.40, 2.17) min, 1.73 (1.47, 2.37) min VS 4.13 (2.27, 5.16) min, H=32.506, P<0.001], better trajectory deviation (0.50±0.11 mm, 0.46±0.11 mm VS 0.82±0.26 mm, F=38.999, P<0.001], and less workload [42.00 (30.00, 50.33) points, 43.33 (35.33, 54.00) points VS 52.67 (48.67, 63.33) points, H=20.056, P<0.001] than operating ordinary endoscope. In the advanced group, the operators operating RDES with 1∶1 or 5∶1 motion scaling to complete endoscopic circle drawing had longer completion time than operating ordinary endoscope [1.72 (1.37, 2.53) min, 1.57 (1.25, 2.58) min VS 1.15 (0.86, 1.58) min, H=13.233, P=0.001], but trajectory deviation [0.47 (0.13, 0.57) mm, 0.44 (0.39, 0.58) mm VS 0.52 (0.42, 0.59) mm, H=3.202, P=0.202] and workload (44.62±21.77 points, 41.24±12.57 points VS 44.71±17.92 points, F=0.369, P=0.693) were not different from those of the ordinary endoscope. Conclusion:The RDES enables remote control, greatly reducing the endoscopists' workload. Additionally, it gives full play to the cooperative motion function of the large and small endoscopic knobs, making the control more flexible. Finally, it increases motion scaling switching function to make the control of endoscope more flexible and more accurate. It is also easy for beginners to learn and master, and can shorten the training period. So it can provide the possibility of remote endoscopic control and fully automated robotic endoscope.
8.Research status of anti-inflammatory effect of traditional Chinese medicine based on NLRP3 inflammatory body
Fu-Mei XU ; Jun-Yuan ZENG ; Lei ZHAO ; Qi-Li ZHANG ; Peng-Fei XIA ; Yin-Qiang JIA ; Jie WANG ; Peng-Xia FANG ; Yan-Li XU
The Chinese Journal of Clinical Pharmacology 2024;40(6):923-927
Inflammasome is a kind of intracellular polyprotein complex,which is an important component of the complex system of local inflammatory microenvironment after human tissue damage.When the inflammasome is activated,it induces the activation of cysteine aspartate proteinase 1(caspase-1),mediates the maturation and secretion of proinflammatory cytokines,such as interleukin(IL)-1 β and IL-18,and induces cell death,which plays an important role in regulating the host immune response to pathogen infection and tissue repair of cell damage.Nod-like receptor protein 3(NLRP3)inflammatory body,which is composed of NLRP3,pro-cysteine aspartic acid specific protease-1(pro-caspase-1)and apoptosis-related spot-like protein(ASC),is the most deeply and widely studied type of inflammatory body,which plays an important role in the regulation of inflammation.When NLRP3 inflammatory bodies are activated,inflammatory mediators are produced and released,which participate in the occurrence and development of a variety of inflammatory diseases.Some studies have shown that traditional Chinese medicine can improve the pathological state of a variety of diseases by inhibiting NLRP3 inflammatory bodies,and play a role in the prevention and treatment of a variety of inflammatory diseases,including cardiovascular diseases,joint inflammation,diabetes and so on.This paper systematically combs the mechanism of NLRP3 inflammatory bodies,and summarizes the latest research reports on the effects of traditional Chinese medicine compound prescription,traditional Chinese medicine monomers and traditional Chinese medicine extracts on NLRP3 inflammatory bodies in the treatment of inflammatory diseases,in order to provide new ideas for the further study of the pathogenesis and drug treatment of many inflammatory diseases.
9.Nutritional status of pediatric patients undergoing allogeneic hematopoietic stem cell transplantation
Mei YAN ; Wei-Bing TANG ; Yong-Jun FANG ; Jie HUANG ; Ting ZHU ; Jin-Yu FU ; Xiao-Na XIA ; Chang-Wei LIU ; Yuan-Yuan WAN ; Jian PAN
Parenteral & Enteral Nutrition 2024;31(5):257-261
Objective:To observe the changes in the nutritional status of pediatric patients after allogeneic hematopoietic stem cell transplantation(allo-HSCT)for one year,and to analyze the risk factors.Methods:We collected data from 88 pediatric patients who underwent allo-HSCT at the Department of Hematology and Oncology in Children's Hospital of Nanjing Medical University between May 2018 and November 2022.All pediatric patients underwent nutritional status analysis before transplantation,at enrollment,3 months,6 months and 1 year after allo-HSCT.Linear regression model was used to analyze the risk factors for growth rate.Results:The body mass index Z score(BMI-Z)before allo-HSCT was(0.096±1.349),and decreased to(-0.258±1.438)、(-0.715±1.432)、(-0.584±1.444)at enrollment,3 months,6 months after allo-HSCT,and(-0.130±1.317)at 1 year after allo-HSCT(P<0.001).There was no significant change in BMI-Z between pre-transplantation and 1 year after transplantation(P=1.000).Height for age Z score(HAZ)before transplantation was(0.137±1.305)and decreased to(-0.083±1.267)、(-0.221±1.299)、(-0.269±1.282)in 3 months,6 months and 1 year after allo-HSCT(P<0.001).Multivariate linear regression showed that age≥10 years old(P=0.015)and chronic graft-versus-host disease(cGVHD)(P=0.005)were independent risk factors for change in HAZ.Conclusion:The BMI-Z of pediatric patients treated with allo-HSCT returned to the pre-transplantation level after one year,while HAZ continued to decrease.Allo-HSCT may cause impaired growth rate in pediatric patients.Attention should be paid to HAZ changes in pediatric patients before and after allo-HSCT,especially in pediatric patients≥10 years old of age and those with cGVHD.Effective nutritional intervention should be provided in time.
10.Design of automatic urine volume detection and collection device
Yan CHEN ; De-Zhao ZHAI ; Xiao-Quan ZHANG ; Fu-Long LIU ; Xiao-Tao ZHANG ; Yong-Mei ZHANG ; Wei CEHN ; Fang ZHANG ; Guo-Hui WU ; Jun DENG ; Dan LI
Chinese Medical Equipment Journal 2024;45(4):66-69
Objective To develop an automatic urine volume detection and collection device to solve the problems of routine urine test.Methods An automatic urine volume detection and collection device was developed with the components of a main control system,a detection system,a prompting system and a grasping and moving system.The main control system consisted of two STM32 microcontrollers and a reset switch;the detection system was made up of a weighing module,an infrared module and indicator lights,which had its urine volume automatic detection algorithm developed based on the Keil5 platform;the prompting system realized voice broadcasting through the voice module fixed on the back panel of the box;the grasping and moving system was composed of a rail drive motor(86CM stepper motor),a photoelectric switch and a motorized gripper.Results The device developed tested urine samples with an accuracy of 99.44%,and could collect qualified samples automatically and quickly.Conclusion The device developed detects urine volume and collects samples automatically,and enhances the accuracy and efficiency of urine examination.[Chinese Medical Equipment Journal,2024,45(4):66-69]

Result Analysis
Print
Save
E-mail