1.Criteria and prognostic models for patients with hepatocellular carcinoma undergoing liver transplantation
Meng SHA ; Jun WANG ; Jie CAO ; Zhi-Hui ZOU ; Xiao-ye QU ; Zhi-feng XI ; Chuan SHEN ; Ying TONG ; Jian-jun ZHANG ; Seogsong JEONG ; Qiang XIA
Clinical and Molecular Hepatology 2025;31(Suppl):S285-S300
Hepatocellular carcinoma (HCC) is a leading cause of cancer-associated death globally. Liver transplantation (LT) has emerged as a key treatment for patients with HCC, and the Milan criteria have been adopted as the cornerstone of the selection policy. To allow more patients to benefit from LT, a number of expanded criteria have been proposed, many of which use radiologic morphological characteristics with larger and more tumors as surrogates to predict outcomes. Other groups developed indices incorporating biological variables and dynamic markers of response to locoregional treatment. These expanded selection criteria achieved satisfactory results with limited liver supplies. In addition, a number of prognostic models have been developed using clinicopathological characteristics, imaging radiomics features, genetic data, and advanced techniques such as artificial intelligence. These models could improve prognostic estimation, establish surveillance strategies, and bolster long-term outcomes in patients with HCC. In this study, we reviewed the latest findings and achievements regarding the selection criteria and post-transplant prognostic models for LT in patients with HCC.
2.Clinical analysis of fusion therapy for type Ⅱ painful scaphoid of foot accessory
Jun-jie LI ; Jiang-feng ZHANG ; Jia-bao DONG ; Mi-yang XU ; Gen-rui ZHU ; Xiong-feng LI
China Journal of Orthopaedics and Traumatology 2025;38(6):608-612
Objective To explore clinical effect of accessory scaphoid bone fusion in treating type Ⅱ painful accessory scaphoid bone.Methods A retrospective analysis was performed on 26 patients with type Ⅱ painful accessory navicular bone treated by accessory navicular bone fusion from January 2012 to June 2022,including 1 male and 25 females,aged from 18 to 70 years old with an average of(44.61±16.32)years old;10 patients with type Ⅱ A and 16 patients with type Ⅱ B;20 patients with simple fusion and 6 patients with fusion plus calcaneal translocation osteotomy.Changes of Meary angle,Pitch angle,an-teroposterior talar-first metatarsal angle(T1MA),talonavicular coverage angle(TCA),lateral talocalcaneal angle(LTCA)be-fore operation and 6 months after operation were observed and compared,and American Orthopedic Foot and Ankle Society(AOFAS)foot and ankle score and visual analogue scale(VAS)were used to explore clinical effect.Results All 26 patients were followed up for 7 to 24 months with an average of(10.72±3.94)months.Meary angle,Pitch angle,T1MA,TCA and LTCA were improved from(9.20±2.57)°,(16.45±3.57)°,(33.34±5.02)°,(22.42±5.86)°,(48.89±4.43)° before opertaion to(3.33±1.06)°,(22.33±4.56)°,(23.89±3.48)°,(11.83±2.67)°,(36.50±3.50)° at 6 months after operation,the difference were statistically significant(P<0.01).Postoperative AOFAS foot and ankle score were(86.24±4.33)and(93.18±6.02)for type Ⅱ A and type Ⅱ B at 6 months,which were significantly improved compared with those for type Ⅱ A and type Ⅱ B before op-eration(67.34±6.55)and(65.12±9.51),and the difference was statistically significant(P<0.01);20 patients got excellent re-sult,5 good and 1 poor.Preoperative VAS of type ⅡA(5.67±1.58)and type Ⅱ B(5.77±1.49)were improved to(2.13±1.01)and(1.43±0.68)at 6 months after operation,with statistical significance(P<0.01).Conclusion Fusion of accessory navicular bone in patients with type Ⅱ painful accessory navicular bone combined with internal calcaneal osteotomy in patients with par-tial calcaneal valvaration could effectively correct flat foot deformity and relieve pain,and could be used as a clinical treatment for painful accessory navicular bone.
3.Chinese experts' consensus on principles of preoperative hair removal
Yiping MAO ; Jun ZHENG ; Lei LI ; Deyan YANG ; Bing ZHANG ; Lei YANG ; Wang JIA ; Peng KANG ; Hui JIAO ; Yun YANG ; Qi QI ; Shiqing FENG ; Xiao LONG ; Yuewei ZHANG ; Xiaohui WANG ; Lize WANG ; Yuan WEI ; Jichao ZHOU ; Minghui MAO ; Pengju XIN ; Hongyu TAN ; Dahong ZHANG ; Lianxin LIU ; Lei TAO ; Xietong WANG ; Xiaoning YUAN ; Mang CAI ; Li MU ; Fang DU ; Rongzhu CHEN ; Fengmao ZHAO ; Jiuzuo HUANG ; Mingzi ZHANG ; Jie ZHANG ; Baoguo WANG ; Kun WANG ; Fang LUO ; Jinhua ZHANG ; Nong HE ; Ling LYU ; Zhiyong ZONG
Chinese Journal of Nosocomiology 2025;35(10):1441-1449
To formulate an expert consensus on the principles of preoperative hair removal and provide scientific guidance for standardized removal of hair before surgical procedures so as to reduce the incidence of surgical site infections.METHODS Led by the Hospital Management Institute of National Health Commission of the People's Republic of China,this consensus was reached with the joint efforts from the expects of relevant fields such as surgeries,interventional therapies,nursing,and infection prevention and control.The consensus facilitates the classification and evaluation of literatures by following the evidence grade formulated by Oxford Evidence-based Medicine Center and focuses on the association of preoperative hair removal with surgical site infection,it reaches the evidence grade of expert consensus and recommendation intensity by integrating with discussions on meetings and clinical experience of the expects from relevant fields.RESULTS A total of 6 items of consensus were reached by summarizing the latest evidence on the aspects including the indications for preoperative hair removal,tools,range,timing and places.CONCLUSION The consensus,to some extent,make supplements to and complete the exiting regulations and standards.It provides guidance for the medical institutions to carry out the preoperative hair removal.
4.Dynamic electrical impedance tomography imaging algorithm based on complementary information fusion network
Xin-yi WANG ; Tao ZHANG ; Xiang TIAN ; Ning YANG ; Jun-jie DU ; Xue-chao LIU ; Feng FU ; Xue-tao SHI ; Can-hua XU
Chinese Medical Equipment Journal 2025;46(6):1-6
Objective To propose a dynamic electrical impedance tomography imaging algorithm based on complementary information fusion network(CIFN)to enhance image quality of dynamic electrical impedance imaging.Methods There were three modules for initialization,multi-frame complementary information extraction and information fusion involved in the CIFN.Firstly,multi-frame dynamic conductivity distribution images were obtained by the initialization module;secondly,spatial complementary information was extracted from the images by using the multi-frame complementary information extraction module;finally,the fusion of lesion target distribution information and target re-reconstruction were realized by the information fusion module to aquire high-quality EIT images.With a 16-electrode multilayer cranial simulation model,the CIFN-based imaging method was compared with Tikhonov regularization algorithm,spectral constraint algorithm and U-Net algorithm in terms of imaging results of types of lesions to verify its performance.Results Compared with the Tikhonov regularization algorithm,spectral constraint algorithm and U-Net algorithm,the proposed CIFN-based algorithm exhibited the lowest mean absolute error(MAE)and the highest structural similarity(SSIM)when used to image different lesion targets,which accurately reconstructed the distribution of lesion targets and gained high imaging stability under common noise levels.Conclusion The proposed CIFN-based imaging algorithm obtains high imaging quality on a cranial simulation model and reconstruction results close to the real model distribution,which provides algorithmic support for subsequent clinical studies on electrical impedance imaging.[Chinese Medical Equipment Journal,2025,46(6):1-6]
5.Transcatheter aortic valve implantation for native aortic valve regurgitation:single-centre experience
Xiao-xue ZHANG ; Yi FENG ; Xian-tao MA ; Yu-jie YANG ; Akilu WAJEEHULLAHI ; Chen-xi YAN ; Zi-yue ZHANG ; Zi-jun CHEN ; Bo QIN ; Shi-liang LI ; Cai CHENG
Chinese Journal of Interventional Cardiology 2025;33(1):33-41
Objective To evaluate the efficacy and safety of transcatheter aortic valve implantation(TAVI)for the treatment of primary aortic valve regurgitation(NAVR)and to compare the difference in the choice of prosthetic valve size and the difference in complications with aortic stenosis(AS).Methods According to the definition of Valve Academic Research Consortium(VARC-3),143 patients with NAVR/AS treated with TAVI and patients with NAVR treated with surgical aortic valve replacement(SAVR)at Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,China,from March 2019 to September 2024 were selected,and clinical data on baseline,perioperative,and primary endpoint events were were retrospectively collected and compared.Results Forty-three patients with NAVR were treated with TAVI,with a device success rate of 86.0%and a surgical success rate of 95.3%.Subgroup comparisons:(1)NAVR-TAVI group than NAVR-SAVR group:patients in the TAVI group had a significantly shorter operative time than those in the SAVR group(P<0.001);complete left bundle branch block was more likely to occur after TAVI(P=0.042),and complete right bundle branch block was more likely to occur after SAVR(P=0.044).SAVR postoperatively The incidence of congestive heart failure was higher(P=0.013),and the mortality rate was significantly higher in the SAVR group than in the TAVI group(P=0.019).(2)NAVR-TAVI group than AS-TAVI group:the differences in access selection,THV size[28(22,34)mm vs.24(22,32)mm,P=0.044]and proportion of THV overdiameter[14%(7%,20%)vs.7%(3%,11%),P<0.001]were statistically significant.patients in AS and NAVR groups had 1 case of permanent pacing after TAVI treatment.In the AS and NAVR groups,there was 1 case of permanent pacemaker implantation after TAVI.2 patients in the AS group were converted to surgical treatment,and 6 patients died.Conclusions The use of"off-label"(transfemoral)and"on-label"(transapical)TAVI devices(both from domestic sources)is safer than SAVR for the treatment of NAVR,especially in elderly and high-risk patients.Compared with patients with AS treated with TAVI,larger diameter annulas are usually selected for NAVR,with higher rates of valve migration,but overall safety and efficacy are comparable to AS.
6.Quantitative analysis of motion of cardiac substructures in deep inspiratory breath holding radiotherapy for left breast cancer
Zhao-hui TANG ; Zhe ZHANG ; Wei-bin MAO ; Bo HUANG ; Jun-feng AI ; Chao-fan ZHU ; Zhi-chao XIE ; Ya-jie LIU
Chinese Medical Equipment Journal 2025;46(3):54-58
Objective To quantify the volume and movement of cardiac substructures by using coronary computed tomography angiography(CCTA)to provide guidance for the design of deep inspiratory breath-holding radiation therapy for left breast cancer and the protection of organs at risk.Methods Totally 18 female patients who received conventional chest plain scan and CCTA were selected to simulate the design process of radiotherapy plan for left breast cancer patients with internal mammary lymph nodes.Retrospective reconstruction of CCTA data was performed for each patient,with 10 phase images(with an interval of 10%)within a R-R cardiac cycle(10%-100%)to simulate the true range of motion of the heart.The heart,left atrium(LA),left ventricle(LV),right atrium(RA),right ventricle(RV),left anterior descending artery(LAD),left circumflex coronary artery(LCX)and right coronary artery(RCA)were contoured at each phase.The distances from the centroid position to the average position of LAD,LCX and RCA were measured at each phase in the superior-inferior(SI),anterior-posterior(AP)and left-right(LR).The average volume and range of volume changes of LA,LV,RA,RV and heart were analyzed within a cardiac cycle.The expansion margins of planning organs at risk volume(PRV)were calculated.SPSS 19.0 software was used for statistical analysis.Results The following average absolute displacements were found in SI,AP and LR coordinates:(1.8±0.7)mm,(1.2±0.5)mm and(1.5±0.5)mm for LAD,respectively;(2.1±0.7)mm,(1.5±0.6)mm and(1.9±0.7)mm for LCX,respectively;(1.6±0.5)mm,(2.2±0.9)mm and(2.2±0.8)mm for RCA,respectively.The volume changes of LA,LV,RA,RV and heart within a cardiac cycle ranged from 34.3 to 63.9 cm3,122.1 to 154.3 cm3,29.3 to 53.6 cm3,57.2 to 94.3 cm3 and 480.1 to 515.4 cm3,respectively.The theoretical expansion margins of LAD,LCX and RCA in all the three directions were within 2 mm.Conclusion The ranges of movement and volume changes of cardiac substructure are quantitati-vely displayed,and references are provided for the planning of deep inspiratory breath-holding radiation therapy for left breast cancer and the protection of organs at risk.[Chinese Medical Equipment Journal,2025,46(3):54-58]
7.Design and realization of VR-based air evacuation training system
Cheng-ye ZHANG ; Fa-lin LI ; Hui ZHANG ; Yu-dong MA ; Wen KUANG ; Tai-feng LIU ; Yu-jie MA ; Jun WANG ; Xiao-jiao LYU ; Yan ZHOU
Chinese Medical Equipment Journal 2025;46(3):15-20
Objective To design a VR-based air evacuation training system for simulating the on-board medical treatment process during air evacuation.Methods A VR-based air evacuation training system was developed which used 3D modeling technology to construct models of the medical aircraft cabin,medical devices and virtual characters to achieve scene interaction.The hardware part of the system included server computers,training terminal computers,VR equipment,3D fusion projection equipment,motion capture equipment,etc.The software of the system was developed using C++,UE4 Blueprint and C# programming languages,including two modules for medical treatment unit and medical treatment training process evaluation.The efficacy of the system was verified by the trials in air evacuation.Results The system developed successfully simulated the scenarios of tracheal tube dislodgement and increased intracranial pressure in the scenario model of open severe craniocerebral injury.The expert evaluation showed that the system gained advantages in training efficiency,low cost,safety,sense of immersion and recorded the operation data in real time to optimize the follow-up training.Conclusion The system developed delivers a virtual training environment with high-fidelity replication of real-mission conditions,enabling whole-course and immersive air evacuation drills.[Chinese Medical Equipment Journal,2025,46(3):15-20]
8.Quantitative analysis of motion of cardiac substructures in deep inspiratory breath holding radiotherapy for left breast cancer
Zhao-hui TANG ; Zhe ZHANG ; Wei-bin MAO ; Bo HUANG ; Jun-feng AI ; Chao-fan ZHU ; Zhi-chao XIE ; Ya-jie LIU
Chinese Medical Equipment Journal 2025;46(3):54-58
Objective To quantify the volume and movement of cardiac substructures by using coronary computed tomography angiography(CCTA)to provide guidance for the design of deep inspiratory breath-holding radiation therapy for left breast cancer and the protection of organs at risk.Methods Totally 18 female patients who received conventional chest plain scan and CCTA were selected to simulate the design process of radiotherapy plan for left breast cancer patients with internal mammary lymph nodes.Retrospective reconstruction of CCTA data was performed for each patient,with 10 phase images(with an interval of 10%)within a R-R cardiac cycle(10%-100%)to simulate the true range of motion of the heart.The heart,left atrium(LA),left ventricle(LV),right atrium(RA),right ventricle(RV),left anterior descending artery(LAD),left circumflex coronary artery(LCX)and right coronary artery(RCA)were contoured at each phase.The distances from the centroid position to the average position of LAD,LCX and RCA were measured at each phase in the superior-inferior(SI),anterior-posterior(AP)and left-right(LR).The average volume and range of volume changes of LA,LV,RA,RV and heart were analyzed within a cardiac cycle.The expansion margins of planning organs at risk volume(PRV)were calculated.SPSS 19.0 software was used for statistical analysis.Results The following average absolute displacements were found in SI,AP and LR coordinates:(1.8±0.7)mm,(1.2±0.5)mm and(1.5±0.5)mm for LAD,respectively;(2.1±0.7)mm,(1.5±0.6)mm and(1.9±0.7)mm for LCX,respectively;(1.6±0.5)mm,(2.2±0.9)mm and(2.2±0.8)mm for RCA,respectively.The volume changes of LA,LV,RA,RV and heart within a cardiac cycle ranged from 34.3 to 63.9 cm3,122.1 to 154.3 cm3,29.3 to 53.6 cm3,57.2 to 94.3 cm3 and 480.1 to 515.4 cm3,respectively.The theoretical expansion margins of LAD,LCX and RCA in all the three directions were within 2 mm.Conclusion The ranges of movement and volume changes of cardiac substructure are quantitati-vely displayed,and references are provided for the planning of deep inspiratory breath-holding radiation therapy for left breast cancer and the protection of organs at risk.[Chinese Medical Equipment Journal,2025,46(3):54-58]
9.Design and realization of VR-based air evacuation training system
Cheng-ye ZHANG ; Fa-lin LI ; Hui ZHANG ; Yu-dong MA ; Wen KUANG ; Tai-feng LIU ; Yu-jie MA ; Jun WANG ; Xiao-jiao LYU ; Yan ZHOU
Chinese Medical Equipment Journal 2025;46(3):15-20
Objective To design a VR-based air evacuation training system for simulating the on-board medical treatment process during air evacuation.Methods A VR-based air evacuation training system was developed which used 3D modeling technology to construct models of the medical aircraft cabin,medical devices and virtual characters to achieve scene interaction.The hardware part of the system included server computers,training terminal computers,VR equipment,3D fusion projection equipment,motion capture equipment,etc.The software of the system was developed using C++,UE4 Blueprint and C# programming languages,including two modules for medical treatment unit and medical treatment training process evaluation.The efficacy of the system was verified by the trials in air evacuation.Results The system developed successfully simulated the scenarios of tracheal tube dislodgement and increased intracranial pressure in the scenario model of open severe craniocerebral injury.The expert evaluation showed that the system gained advantages in training efficiency,low cost,safety,sense of immersion and recorded the operation data in real time to optimize the follow-up training.Conclusion The system developed delivers a virtual training environment with high-fidelity replication of real-mission conditions,enabling whole-course and immersive air evacuation drills.[Chinese Medical Equipment Journal,2025,46(3):15-20]
10.Transcatheter aortic valve implantation for native aortic valve regurgitation:single-centre experience
Xiao-xue ZHANG ; Yi FENG ; Xian-tao MA ; Yu-jie YANG ; Akilu WAJEEHULLAHI ; Chen-xi YAN ; Zi-yue ZHANG ; Zi-jun CHEN ; Bo QIN ; Shi-liang LI ; Cai CHENG
Chinese Journal of Interventional Cardiology 2025;33(1):33-41
Objective To evaluate the efficacy and safety of transcatheter aortic valve implantation(TAVI)for the treatment of primary aortic valve regurgitation(NAVR)and to compare the difference in the choice of prosthetic valve size and the difference in complications with aortic stenosis(AS).Methods According to the definition of Valve Academic Research Consortium(VARC-3),143 patients with NAVR/AS treated with TAVI and patients with NAVR treated with surgical aortic valve replacement(SAVR)at Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,China,from March 2019 to September 2024 were selected,and clinical data on baseline,perioperative,and primary endpoint events were were retrospectively collected and compared.Results Forty-three patients with NAVR were treated with TAVI,with a device success rate of 86.0%and a surgical success rate of 95.3%.Subgroup comparisons:(1)NAVR-TAVI group than NAVR-SAVR group:patients in the TAVI group had a significantly shorter operative time than those in the SAVR group(P<0.001);complete left bundle branch block was more likely to occur after TAVI(P=0.042),and complete right bundle branch block was more likely to occur after SAVR(P=0.044).SAVR postoperatively The incidence of congestive heart failure was higher(P=0.013),and the mortality rate was significantly higher in the SAVR group than in the TAVI group(P=0.019).(2)NAVR-TAVI group than AS-TAVI group:the differences in access selection,THV size[28(22,34)mm vs.24(22,32)mm,P=0.044]and proportion of THV overdiameter[14%(7%,20%)vs.7%(3%,11%),P<0.001]were statistically significant.patients in AS and NAVR groups had 1 case of permanent pacing after TAVI treatment.In the AS and NAVR groups,there was 1 case of permanent pacemaker implantation after TAVI.2 patients in the AS group were converted to surgical treatment,and 6 patients died.Conclusions The use of"off-label"(transfemoral)and"on-label"(transapical)TAVI devices(both from domestic sources)is safer than SAVR for the treatment of NAVR,especially in elderly and high-risk patients.Compared with patients with AS treated with TAVI,larger diameter annulas are usually selected for NAVR,with higher rates of valve migration,but overall safety and efficacy are comparable to AS.

Result Analysis
Print
Save
E-mail