1.Exploration of Milestone Evaluation System for Core Competencies in Knowledge and Skills of Neurology Residents
Liling DONG ; Dan XU ; Yuze CAO ; Siyuan FAN ; Hang LI ; Yicheng ZHU ; Lixin ZHOU ; Jun NI
Medical Journal of Peking Union Medical College Hospital 2025;16(6):1619-1628
To develop a milestone-based evaluation system for the core "knowledge and skills" competency of neurology residents that is tailored to China's medical context, so as to provide precise guidance for their training and assessment. Using the Delphi method, the study first constructed an initial framework through literature review, on-site investigation and expert-group discussion. Two rounds of expert consultation were then conducted among specialists in neurology education across China. Indicators were screened and optimized according to the mean score, agreement rate and coefficient of variation (CV), ultimately finalizing the system. The expert response rates in both rounds were 100%. The group authority coefficients were 0.97 and 0.98, with Cronbach's α of 0.90 and 0.88, respectively. The mean scores of all indicators ranged from 3.88 to 5.00, agreement rates from 62.50 % to 100 %, and CVs from 0 to 0.21. The finalized framework comprises one first-level indicator, three second-level indicators and 17 third-level indicators. The milestone evaluation system for core competencies in "knowledge and skills" of neurology residents developed in this study is scientific and reasonable, providing a standardized and scientific assessment tool for the standardized training of neurology residents.
2.Investigation and characteristics of extended high frequency hearing in young adults
Xinyu DONG ; Ying LIN ; Qianjin GAO ; Ziqi WU ; Pengfei HANG ; Xiaoqing FAN ; Zhemaiwei ZHAO ; Liu QI ; Jun CHEN ; Dingjun ZHA
Journal of Audiology and Speech Pathology 2025;33(2):156-160
Objective To investigate extended high-frequency hearing in young adults and to analyse its char-acteristics.Methods A total of 230 freshmen(101 males and 129 females,aged 17-19 years old)from the class of 2023 at the Air Force Medical University underwent audiometric tests,including acoustic impedance,conventional frequency and extended high-frequency audiometry,and distortion product otoacoustic emissions(DPOAE).Ac-cording to the results of extended high-frequency audiometry,the students were divided into normal and abnormal groups,and the hearing thresholds at conventional frequencies were compared between the two groups.Results Of the 230 students,47.83%(110/230)showed abnormal extended high-frequency hearing.The hearing thresholds of the right ear were 1 to 3 dB higher than those of the left ear at most frequencies.The hearing thresholds of the ab-normal group were higher than those of the normal group in the conventional frequencies(P<0.05).The difference in extended high-frequency thresholds between the two groups increased with higher frequency.Conclusion Ex-tended high-frequency hearing loss occurs earlier,and has a higher prevalence in young adults,and right ear hearing is worse than that of left ear.Extended high-frequency audiometry can be used as a predictive tool for detecting con-ventional frequency hearing loss.
3.Measurement method based on EBT3 film technology for quality control detection of INTRABEAM PRS500 intraoperative radiotherapy equipment
Yi-kun LI ; Wei DING ; Xia-yu HANG ; Jun HU ; Xiang-dong SUN ; Ai-jun XU
Chinese Medical Equipment Journal 2025;46(6):47-53
Objective To propose an EBT3 film technology-based quality control measurement method for the INTRABEAM PRS500 intraoperative radiotherapy equipment to solve the problems of the traditional methods in cumbersome operation and setup error.Methods According to HJ 1198-2021 Requirements of radiation safety and protection for radiotherapy and GBZ 121-2020 Requirements for radiological protection in radiotherapy,the environmental radiation testing of the INTRABEAM PRS500 intraoperative radiotherapy equipment was carried out point by point by means of the radiation inspection instrument.The INTRABEAM PRS500 intraoperative radiotherapy equipment was characterized by a point X-ray source(XRS),and the XRS was detected in terms of the probe linearity,radiation dose,dynamic deviation,isotropy and dose rate.The EBT3 film technology was used to verify the symmetry and isotropy of the XRS planar dose of INTRABEAM PRS500 intraoperative radiotherapy equipment.Results The X-γ dose equivalent rate of each monitoring site of the INTRABEAM PRS500 intraoperative radiotherapy device was lower than the method detection limit(MDL).The results of SQA quality control showed that the INTRABEAM PRS500 intraoperative radiotherapy equipment XRS met the quality control requirements in terms of the probe linearity,radiation dose,dynamic deviation and etc,and the isotropy differences in the+X,-X,+Y,and-Y axis directions ranged from-1.40%to 1.79%,which were all within the allowable range of measurement tolerance(5.60%to 5.65%).The results of measuring the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment based on the EBT3 film technology showed that the dose distribution of the XRS in the directions of the+X,-X,+Y,and-Y axes at the same plane was well isotropic,and that the doses in the directions of the X and Y axes were symmetrically distributed,and that the maximum skewness value for the isotropy of the XRS in the XY plane was-1.581%,which met the requirements of AAPM TG61 report on the reference dosimetry of low-energy and medium-energy X-rays for radiotherapy and radiobiology of≤±5.3%.Conclusion The EBT3 film technology-based measurement method gains high simplicity and feasibility for the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment in the directions of the+X,-X,+Y,and-Y axes at the same planet,which realizes the dynamic monitoring of the dosimetric changes and facilitates the whole-process quality control management of the intraoperative radiotherapy equipment.[Chinese Medical Equipment Journal,2025,46(6):47-53]
4.Investigation and characteristics of extended high frequency hearing in young adults
Xinyu DONG ; Ying LIN ; Qianjin GAO ; Ziqi WU ; Pengfei HANG ; Xiaoqing FAN ; Zhemaiwei ZHAO ; Liu QI ; Jun CHEN ; Dingjun ZHA
Journal of Audiology and Speech Pathology 2025;33(2):156-160
Objective To investigate extended high-frequency hearing in young adults and to analyse its char-acteristics.Methods A total of 230 freshmen(101 males and 129 females,aged 17-19 years old)from the class of 2023 at the Air Force Medical University underwent audiometric tests,including acoustic impedance,conventional frequency and extended high-frequency audiometry,and distortion product otoacoustic emissions(DPOAE).Ac-cording to the results of extended high-frequency audiometry,the students were divided into normal and abnormal groups,and the hearing thresholds at conventional frequencies were compared between the two groups.Results Of the 230 students,47.83%(110/230)showed abnormal extended high-frequency hearing.The hearing thresholds of the right ear were 1 to 3 dB higher than those of the left ear at most frequencies.The hearing thresholds of the ab-normal group were higher than those of the normal group in the conventional frequencies(P<0.05).The difference in extended high-frequency thresholds between the two groups increased with higher frequency.Conclusion Ex-tended high-frequency hearing loss occurs earlier,and has a higher prevalence in young adults,and right ear hearing is worse than that of left ear.Extended high-frequency audiometry can be used as a predictive tool for detecting con-ventional frequency hearing loss.
5.Measurement method based on EBT3 film technology for quality control detection of INTRABEAM PRS500 intraoperative radiotherapy equipment
Yi-kun LI ; Wei DING ; Xia-yu HANG ; Jun HU ; Xiang-dong SUN ; Ai-jun XU
Chinese Medical Equipment Journal 2025;46(6):47-53
Objective To propose an EBT3 film technology-based quality control measurement method for the INTRABEAM PRS500 intraoperative radiotherapy equipment to solve the problems of the traditional methods in cumbersome operation and setup error.Methods According to HJ 1198-2021 Requirements of radiation safety and protection for radiotherapy and GBZ 121-2020 Requirements for radiological protection in radiotherapy,the environmental radiation testing of the INTRABEAM PRS500 intraoperative radiotherapy equipment was carried out point by point by means of the radiation inspection instrument.The INTRABEAM PRS500 intraoperative radiotherapy equipment was characterized by a point X-ray source(XRS),and the XRS was detected in terms of the probe linearity,radiation dose,dynamic deviation,isotropy and dose rate.The EBT3 film technology was used to verify the symmetry and isotropy of the XRS planar dose of INTRABEAM PRS500 intraoperative radiotherapy equipment.Results The X-γ dose equivalent rate of each monitoring site of the INTRABEAM PRS500 intraoperative radiotherapy device was lower than the method detection limit(MDL).The results of SQA quality control showed that the INTRABEAM PRS500 intraoperative radiotherapy equipment XRS met the quality control requirements in terms of the probe linearity,radiation dose,dynamic deviation and etc,and the isotropy differences in the+X,-X,+Y,and-Y axis directions ranged from-1.40%to 1.79%,which were all within the allowable range of measurement tolerance(5.60%to 5.65%).The results of measuring the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment based on the EBT3 film technology showed that the dose distribution of the XRS in the directions of the+X,-X,+Y,and-Y axes at the same plane was well isotropic,and that the doses in the directions of the X and Y axes were symmetrically distributed,and that the maximum skewness value for the isotropy of the XRS in the XY plane was-1.581%,which met the requirements of AAPM TG61 report on the reference dosimetry of low-energy and medium-energy X-rays for radiotherapy and radiobiology of≤±5.3%.Conclusion The EBT3 film technology-based measurement method gains high simplicity and feasibility for the isotropy of the INTRABEAM PRS500 intraoperative radiotherapy equipment in the directions of the+X,-X,+Y,and-Y axes at the same planet,which realizes the dynamic monitoring of the dosimetric changes and facilitates the whole-process quality control management of the intraoperative radiotherapy equipment.[Chinese Medical Equipment Journal,2025,46(6):47-53]
6.Thrombocytopenia after Aortic Valve Replacement Using Sutureless Valves
Mil Hoo KIM ; Soojin LEE ; Juhyun LEE ; Seohee JOO ; You Kyeong PARK ; Kang Min KIM ; Joon Chul JUNG ; Hyoung Woo CHANG ; Jae Hang LEE ; Dong Jung KIM ; Jun Sung KIM ; Kay-Hyun PARK ; Cheong LIM
Journal of Chest Surgery 2024;57(4):371-379
Background:
Sutureless valves are widely used in aortic valve replacement surgery, with Perceval valves and Intuity valves being particularly prominent. However, concerns have been raised about postoperative thrombocytopenia with Perceval valves (Corcym, UK). We conducted a comparative analysis with the Intuity valve (Edwards Lifesciences, USA), and assessed how thrombocytopenia affected patient and transfusion outcomes.
Methods:
Among 595 patients who underwent aortic valve replacement from June 2016 to March 2023, sutureless valves were used in 53 (Perceval: n=23; Intuity: n=30). Platelet counts were monitored during hospitalization and outpatient visits. Daily platelet count changes were compared between groups, and the results from patients who underwent procedures using Carpentier Edwards Perimount Magna valves were used as a reference group.
Results:
Compared to the Intuity group, the Perceval group showed a significantly higher amount of platelet transfusion (5.48±1.64 packs vs. 0.60±0.44 packs, p=0.008). During the postoperative period, severe thrombocytopenia (<50,000/μL) was significantly more prevalent in the Perceval group (56.5%, n=13) than in the Intuity group (6.7%, n=2). After initial postoperative depletion, daily platelet counts increased, with significant differences observed in the extent of improvement between the Perceval and Intuity groups (p<0.001).However, there was no significant difference in early mortality or the incidence of neurological complications between the 2 groups.
Conclusion
The severity of postoperative thrombocytopenia differed significantly between the Perceval and Intuity valves. The Perceval group showed a significantly higher prevalence of severe thrombocytopenia and higher platelet transfusion volumes. However, thrombocytopenia gradually recovered during the postoperative period in both groups, and the early outcomes were similar in both groups.
7.Regulatory effect of physiological tensile stress on differentiation of ATDC5 chondrocytes through Nell-1/Ihh signaling pathway
Ziwei DONG ; Huichuan QI ; Jun MA ; Qing XUE ; Jinhan NIE ; Hang YU ; Min HU
Journal of Jilin University(Medicine Edition) 2024;50(1):1-9
Objective:To discuss the regulatory effect of physiological tensile stress on the differentiation of chondrocytes,and to clarify the associated signaling pathway mechanism.Methods:The ATDC5 chondrocytes were cultured in vitro and subjected to physiological tensile stress by four-point bending cell mechanical loading device.Initially,the cells were divided into control group and tensile stress group(2 000 μstrain/2 h group),and further divided into different stress magnitudes(1 000,2 000,and 3 000 μstrain)for 2 h,and 2 000 μstrain for different duration time(1,2,and 4 h)groups;the cells without tensile stress were used as control group.Real-time fluorescence quantitative PCR(RT-qPCR)method was used to detect the expression levels of type Ⅱ collagen(Col-Ⅱ),type Ⅹ collagen(Col-Ⅹ),aggregated proteoglycom(Aggrecan),sex-determining region Y-box protein 9(SOX9),vascular endothelial growth factor(VEGF),proliferating cell nuclear antigen(PCNA),Nel-like molecule tyep 1(Nell-1),Runt-related transcription factor 2(Runx2),Indian hedgehog(Ihh),patched homolog 1(Ptch-1),GLI family zinc finger protein 1(Gli-1),and hedgehog interacting protein 1(Hhip-1)mRNA in the cells in various groups;Western blotting method was used to detect the expression levels of Nell-1,Runx2,and Ihh proteins in the cells in various groups.The ATDC5 cells were divided into control group,cyclopamine group,tensile stress group,and cyclopamine + tensile stress group.RT-qPCR method was used to detect the expression levels of Nell-1,Ihh,Ptch-1,Gli-1,and Hhip-1 mRNA in the cells in various groups;Western blotting method was used to detect the expression levels of Nell-1 and Ihh proteins in the cells in various groups.Results:Compared with control group,the expression levels of Col-Ⅱ,Col-Ⅹ,Aggrecan,SOX9,VEGF,and PCNA mRNA in the cells in 2 000 μstrain/2 h group were significantly increased(P<0.01);after treated with 2 000 μstrain tensile stress for different duration time(1,2,and 4 h)or different tensile stresses(1 000,2 000,and 3 000 μstrain)for 2 h,compared with control group,the expression levels of Runx2 mRNA in the cells in other groups were increased with the prolongation of time or the increasing of tensile stress(P<0.01),and the expression levels of Nell-1,Ihh,Ptch-1,Gli-1,and Hhip-1 mRNA were gradually increased(P<0.01),the expression levels reached the peaking at 2 000 μstrain/2 h,and then decreased but remained significantly higher than that in control group(P<0.01).The Western blotting results showed that the expression levels of Nell-1,Runx2,and Ihh proteins in the cells were consistent with the change trend of mRNA expression levels.After pre-treated with cyclopamine,compared with control group,the expression levels of Ihh,Ptch-1,Gli-1,and Hhip-1 mRNA in the cells in cyclopamine group were significantly decreased(P<0.01),and the expression levels of Ihh,Ptch-1,Gli-1,and Hhip-1 mRNA in the cells in tensile stress and cyclopamine+tensile stress groups were significantly increased(P<0.01);compared with cyclopamine group,the expression levels of Nell-1,Ihh,Ptch-1,Gli-1,and Hhip-1 mRNA in the cells in cyclopamine+tensile stress group were significantly increased(P<0.01);compared with tensile stress group,the expression levels of Ihh,Ptch-1,Gli-1,and Hhip-1 mRNA in the cells in cyclopamine + tensile stress group were significantly decreased(P<0.01).Compared with control group,the expression level of Ihh protein in the cells in cyclopamine group was significantly decreased(P<0.01),but there was no significant difference in expression level of Nell-1 protein in the cells between control group and cyclopamine group(P>0.05),while the expression levels of Nell-1 and Ihh proteins in the cells in tensile stress group and cyclopamine + tensile stress group were significantly increased(P<0.01);compared with cyclopamine group,the expression levels of Nell-1 and Ihh proteins in the cells in tensile stress group and cyclopamine + tensile stress group were significantly increased(P<0.01);compared with tensile stress group,in the expression levels of Nell-1 and Ihh proteins in the cells in cyclopamine + tensile stress group had no significant differences(P>0.05).Conclusion:After stimulated with physiological tensile stress,Nell-1 can activate the Ihh signaling pathway upstream,and regulate the differentiation of the ATDC5 chondrocytes.
8.Dosimetric effect of calculation grid size on stereotactic body radiation therapy of lung cancer in helical tomotherapy planning system
Xia-Yu HANG ; Wan-Rong JIANG ; Yi-Kun LI ; Jun HU ; Yan ZHANG ; Ruo-Qi CAO ; Nan XU ; Lei WANG ; Jin-Da ZHOU ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(2):52-57
Objective To investigate the dosimetric effects of different calculation grid size(CGS)in helical tomotherapy(HT)planning system on stereotactic body radiation therapy(SBRT)for non-small cell lung cancer(NSCLC).Methods Nine NSCLC patients receiving radiation therapy for the first time at some hospital from March 2019 to December 2022 were selected as the subjects.SBRT planning was carried out through the HT system with three different CGS plans(Fine,Normal,and Coarse)and the same pitch,modulation factor(MF)and optimization conditions,and the target area indexes of the three CGS plans were compared including conformity index(CI),homogeneity index(HI),dosimetric parameters of the organ at risk(OAR),point dose verification pass rate,treatment time,number of monitor units and Sinograms.SPSS 22.0 was used for statistical analysis.Results For target area HI,there weres significant differences between CGS Fine plan and Coarse plan and between CGS Normal plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan(P>0.05).For target area CI,there were significant differences between CGS Fine plan and Coarse plan(P<0.05),while no statistical differences were found between CGS Fine plan and Normal plan and between CGS Normal plan and Coarse plan(P>0.05).For OAR dosimetric parameters,CGS Fine plan and Coarse plan had significant differences in heart Dmax and Dmean,esophageal Dmax and Dmean,V5,V20,V30 and Dmean of the whole lung and affected lung,V5 and Dmax of the affected lung and heart V10 and V30(P<0.05),CGS Normal plan and Coarse plan had obvious differences in esophageal Dmax(P<0.05),and the remained dosimetric parameters were not statistically significant(P>0.05).Fine,Normal and Coarse plans had the point dose verifica-tion pass rates being 0.96%,1.50%and 1.77%,respectively.In terms of treatment time and number of monitor units,there were significant differences between Fine plan and Coarse plan(P<0.05)while no statistical differences were found between Fine and Normal plans and between Normal and Coarse plans(P>0.05).Sinograms analyses showed Fine plan had evenly distributed segment color gradient,Coarse plan had areas of very dark and very light color gradients and Normal plan was somewhere in between.Conclusion Low CGS has to be used as much as possible to obtain accurate dose distribution during SBRT planning for NSCLC patients,which contributes to the execution of the radiation therapy plan and the prevention of ad-verse effects.[Chinese Medical Equipment Journal,2024,45(2):52-57]
9.Dosimetric effect of jaw widths on stereotactic body radiotherapy for hepatocellular carcinoma
Xia-Yu HANG ; Yi-Kun LI ; Jun HU ; Ruo-Qi CAO ; Yan ZHANG ; Nan XU ; Xian-Qiang SONG ; Xiang-Dong SUN
Chinese Medical Equipment Journal 2024;45(7):51-55
Objective To investigate the radiotherapy dose impacts of different jaw widths on stereotactic body radiotherapy(SBRT)for hepatocellular carcinoma(HCC)with the hilical tomotherapy(HT)planning system.Methods Totally 16 HCC patients who received radiotherapy at some hospital from March 2021 to August 2023 were selected,and the planning was carried out with the same pitch,modulation factors and optimization conditions and the jaw widths being 1.0,2.5 and 5.0 cm.The dosimetric differences due to the jaw widths in planned targets and organs at risk(OAR)were compared,and the planned treatment time,monitor unit,gantry rotations and gantry period were evaluated.SPSS 22.0 was used for statistical analysis.Results Better dosimetric parameters and lower doses to OARs could be got with lower jaw widths.The widened jaw widths resulted in reduced planned treatment time,decreased monitor units and gantry rotations,shortened gantry period while enhanced treatment efficiency.Conclusion A 2.5 cm jaw width for HT planning contributes to improving treatment efficiency during HCC SBRT under the premise of ensured target dose distribution and satisfactory dose to OAR for clinical require-ments.[Chinese Medical Equipment Journal,2024,45(7):51-55]
10.Development of Multiple Collector Inductively Coupled Plasma Mass Spectrometry Single Particle Analysis System Based on High-Speed Oscilloscope and Its Application to Isotopic Analysis of Individual Simulated Nuclear Particles
Peng-Ju XING ; Yuan FU ; Stanley Nicholas BELSHAW ; Jun-Hang DONG ; Xing LIU ; Hong-Tao ZHENG ; Zhen-Li ZHU
Chinese Journal of Analytical Chemistry 2024;52(10):1591-1601
The analysis of nano-micro nuclear particles has attracted significant attention due to the crucial role of their elemental and isotopic characteristics in tracing the origins of particulate matter and assessing its potential risks to human health and the environment.However,challenges persist in obtaining accurate and consistent element profiles and ratios for small-sized nanoparticles due to their low level and the transient nature.In this study,a high-speed digital oscilloscope was integrated with multiple collector inductively coupled plasma mass spectrometry(MC-ICP-MS)to develop a high time-resolution"Event-triggered signal capture"(ETSC)system for single particle analysis.This innovative approach enabled the analysis of element/isotope within rare earth nanoparticles at ag-fg level.The ETSC accurately recorded the complete profile of single particle,event captured by the electron multiplier with nanosecond time resolution,allowing for high-sensitivity element analysis and high-precision isotope analysis of single particles.The results demonstrated that the ETSC system could achieve quantitative analysis of ag levels of ytterbium(Yb)in 50-nm rare earth-doped particles,with a detection limit as low as 38 ag for Yb.Moreover,the isotopic precision of single particle analysis for 173/171Yb could reach 0.047(standard deviation),and the standard error for isotopic analysis of multiple particles could achieve a level of 2‰-3‰(permil)for 173/171Yb.Finally,the capability of ETSC system to analyze environmental samples was demonstrated through the analysis of doped ytterbium oxide nanoparticles.All these findings demonstrated that the ETSC provided a unique method for elemental and isotopic analysis of single nuclear particles.

Result Analysis
Print
Save
E-mail