1.The Effects of Tai Chi Training on Bone Density,Bone Turnover Markers,and Heart Rate Variability in High-Risk Osteoporosis Population
Jiaming LIN ; Chao LI ; Wei ZHAO ; Jun ZHOU ; Xiaoying CHEN ; Xiangyu XI ; Haijun HE ; Baohong MI ; Yuefeng CHEN ; Weiheng CHEN
Journal of Traditional Chinese Medicine 2025;66(15):1566-1571
ObjectiveTo explore the effects of the Tai Chi training on bone density, bone turnover markers, and heart rate variability for people with high-risk osteoporosis, and to provide evidence for the prevention of osteoporosis at early stage. MethodsSixty-six cases of people with high risk of osteoporosis were included, and they were divided into 33 cases each in the intervention group and the control group using the random number table method. The control group received osteoporosis health education three times a week, and the intervention group received Tai Chi training under the guidance of a trainer three times a week for 40 mins each time on the basis of the control group, and both groups were intervened for 12 weeks. Dual-energy X-ray absorptiometry was used to measure the bone density of L1~L4 vertebrae, bilateral femoral necks and bilateral total hips in the two groups before and after the intervention; enzyme-linked immunosorbent assay was used to determine bone turnover markers before and after the intervention, including pro-collagen type Ⅰ pro-amino-terminal prepropyl peptide (P1NP) and β-collagen type Ⅰ cross-linking carboxy-terminal peptide (β-CTX). Seven cases with good compliance in the intervention group were selected. After wearing the heart rate sensor, they successively performed Tai Chi training and walking activities recommended by the guideline for 20 mins each, and the heart rate variability (HRV) during exercise was collected, including time-domain indexes such as standard deviation of normal sinus intervals (SDNN), root-mean-square of the difference between adjacent RR intervals (RMSSD), frequency-domain metrics such as low-frequency power (LF), high-frequency power (HF), and low-frequency/high-frequency power ratio (LF/HF), as well as nonlinear metrics such as approximate entropy (ApEn), sample entropy (SampEn). ResultsFinally, 63 cases were included in the outcome analysis, including 30 cases in the intervention group and 33 cases in the control group. After the intervention, the differences of L1~L4 vertebrae, bone density of bilateral femoral neck and bilateral total hip in the intervention group were not statistically significant when compared with those before intervention (P>0.05), while the bone density of all parts of the control group decreased significantly compared with that before intervention (P<0.05), and the difference in the bone density of the L1~L4 vertebrae, bilateral femoral neck, and the right total hip before and after the intervention of the intervention group was smaller than that of the control group (P<0.05). The differences in P1NP and β-CTX between groups before and after intervention was not statistically significant (P>0.05). Compared with walking exercise, LF decreased, HF increased and LF/HF decreased during Tai Chi exercise (P<0.05); the time domain indexes and non-linear indexes between groups had no statistically significant difference (P>0.05). ConclusionTai Chi exercise can maintain lumbar, hip, and femoral bone density and improve sympathetic/parasympathetic balance in people at high risk for osteoporosis, but cannot significantly improve bone turnover markers.
2.Safety and effectiveness of lecanemab in Chinese patients with early Alzheimer's disease: Evidence from a multidimensional real-world study.
Wenyan KANG ; Chao GAO ; Xiaoyan LI ; Xiaoxue WANG ; Huizhu ZHONG ; Qiao WEI ; Yonghua TANG ; Peijian HUANG ; Ruinan SHEN ; Lingyun CHEN ; Jing ZHANG ; Rong FANG ; Wei WEI ; Fengjuan ZHANG ; Gaiyan ZHOU ; Weihong YUAN ; Xi CHEN ; Zhao YANG ; Ying WU ; Wenli XU ; Shuo ZHU ; Liwen ZHANG ; Naying HE ; Weihuan FANG ; Miao ZHANG ; Yu ZHANG ; Huijun JU ; Yaya BAI ; Jun LIU
Chinese Medical Journal 2025;138(22):2907-2916
INTRODUCTION:
Lecanemab has shown promise in treating early Alzheimer's disease (AD), but its safety and efficacy in Chinese populations remain unexplored. This study aimed to evaluate the safety and 6-month clinical outcomes of lecanemab in Chinese patients with mild cognitive impairment (MCI) or mild AD.
METHODS:
In this single-arm, real-world study, participants with MCI due to AD or mild AD received biweekly intravenous lecanemab (10 mg/kg). The study was conducted at Hainan Branch, Ruijin Hospital Shanghai Jiao Tong University School of Medicine. Patient enrollment and baseline assessments commenced in November 2023. Safety assessments included monitoring for amyloid-related imaging abnormalities (ARIA) and other adverse events. Clinical and biomarker changes from baseline to 6 months were evaluated using cognitive scales (mini-mental state examination [MMSE], montreal cognitive assessment [MoCA], clinical dementia rating-sum of boxes [CDR-SB]), plasma biomarker analysis, and advanced neuroimaging.
RESULTS:
A total of 64 patients were enrolled in this ongoing real-world study. Safety analysis revealed predominantly mild adverse events, with infusion-related reactions (20.3%, 13/64) being the most common. Of these, 69.2% (9/13) occurred during the initial infusion and 84.6% (11/13) did not recur. ARIA-H (microhemorrhages/superficial siderosis) and ARIA-E (edema/effusion) were observed in 9.4% (6/64) and 3.1% (2/64) of participants, respectively, with only two symptomatic cases (one ARIA-E presenting with headache and one ARIA-H with visual disturbances). After 6 months of treatment, cognitive scores remained stable compared to baseline (MMSE: 22.33 ± 5.58 vs . 21.27 ± 4.30, P = 0.733; MoCA: 16.38 ± 6.67 vs . 15.90 ± 4.78, P = 0.785; CDR-SB: 2.30 ± 1.65 vs . 3.16 ± 1.72, P = 0.357), while significantly increasing plasma amyloid-β 42 (Aβ42) (+21.42%) and Aβ40 (+23.53%) levels compared to baseline.
CONCLUSIONS:
Lecanemab demonstrated a favorable safety profile in Chinese patients with early AD. Cognitive stability and biomarker changes over 6 months suggest potential efficacy, though high dropout rates and absence of a control group warrant cautious interpretation. These findings provide preliminary real-world evidence for lecanemab's use in China, supporting further investigation in larger controlled studies.
REGISTRATION
ClinicalTrials.gov , NCT07034222.
Humans
;
Alzheimer Disease/drug therapy*
;
Male
;
Female
;
Aged
;
Middle Aged
;
Cognitive Dysfunction/drug therapy*
;
Aged, 80 and over
;
Amyloid beta-Peptides/metabolism*
;
Biomarkers
;
East Asian People
3.Biomechanical study and clinical application of two osteotomy guide methods in media open wedge high tibial osteotomy operation.
Chao QI ; Xiao-Ming LI ; Dong-Hui GUO ; Qiu-Ling SHI ; Yun-Chao ZHAO ; Jun DONG ; Zheng-Xin MENG ; Xing-Yue WANG
China Journal of Orthopaedics and Traumatology 2025;38(7):698-704
OBJECTIVE:
To explore the effectiveness and feasibility of two osteotomy guides in medial open wedge high tibial osteotomy (MOWHTO).
METHODS:
Clinical data of 103 patients who underwent routine MOWHTO surgery between January 2020 and December 2022 were collected for retrospective analysis. The patients were divided into two groups based on the method of osteotomy guide plate. The control group of 51 patients received traditional osteotomy guide plate technique, including 17 males and 34 females, aged from 48 to 68 years old with an average of(57.93±4.82) years old, with a disease duration ranged from 1 to 8 years with an average of (4.89±1.49) years. The observation group of 52 patients received personalized osteotomy guide plate technique, including 23 males and 29 females, aged from 48 to 69 with an average of (58.22±5.10) years, with a disease duration ranged from 1 to 9 years with an average of(5.10±1.55) years. The perioperative indicators, complications, and knee joint recovery rate were statistically analyzed for both groups, as well as the preoperative and postoperative coagulation function, fibrinogen (FIB), D-dimer (D-D), gait parameters (step frequency, step length, step speed), biomechanical indicators, weight bearing line (WBL), medial proximal tibial angle (MPTA), joint line conergence angle (JLCA), and anterior cruciate ligament (ACL) function (body width, tibial anterior displacement).
RESULTS:
All patients were followed up for 6 months. The intraoperative blood loss, operation time, and number of fluoroscopic views in the observation group were (358.58±93.76) ml, (84.42±8.17) min, and (2.00±0.44) times, respectively, which were all less than those in the control group (465.55±105.38) ml, (96.53±10.51) min, and (6.31±0.58) times (P<0.05). Three days after surgery, the FIB and D-D levels in the observation group were (4.21±0.48) g·L-1 and (204.47±35.59) μg·L-1, respectively, which were both lower than those in the control group (5.56±0.57) g·L-1 and (311.12±42.23) μg·L-1 (P<0.05). Three months after surgery, the step frequency, step length, and step speed in the observation group were (1.89±0.23) steps·s-1, (0.57±0.15) m, and (0.99±0.11) m·s-1, respectively, which were all higher than those in the control group (1.80±0.18) steps·s-1, (0.50±0.14) m, and (0.95±0.09) m·s-1 (P<0.05). Three months after surgery, the WBL and MPTA in the observation group were (45.53±4.41)% and (87.03±8.15)°, respectively, which were both higher than those in the control group (38.38±4.36)% and (83.68±8.50)°, and the JLCA was (2.36±0.24)°, which was lower than that in the control group (2.61±0.33)° (P<0.05). The ACL body width during internal fixation removal was (5.60±0.51) mm, which was greater than that in the control group (5.08±0.56) mm, and the tibial migration was (5.70±0.42) mm, which was less than that in the control group (6.33±0.48) mm (P<0.05). There was no significant difference in the incidence of complications between the two groups (P>0.05). Six months after surgery, there was no significant difference in the recovery rate of knee joint between the two groups (P>0.05).
CONCLUSION
The application of personalized osteotomy guide technique in MOWHTO can help improve knee biomechanics and ACL function, and has less effect on coagulation function and no increase in complications.
Humans
;
Male
;
Female
;
Osteotomy/methods*
;
Middle Aged
;
Tibia/physiopathology*
;
Aged
;
Biomechanical Phenomena
;
Retrospective Studies
;
Osteoarthritis, Knee/physiopathology*
4.Screening and Preliminary Validation of Multiple Myeloma Specific Proteins.
Shan ZHAO ; Hui-Hui LIU ; Xiao-Ying YANG ; Wei-Wei XIE ; Chao XUE ; Xiao-Ya HE ; Jin WANG ; Yu-Jun DONG
Journal of Experimental Hematology 2025;33(1):127-132
OBJECTIVE:
To screen novel diagnostic marker or therapeutic target for multiple myeloma (MM).
METHODS:
Sel1L, SPAG4, KCNN3 and PARM1 were identified by bioinformatics method based on GEO database as high expression genes in MM. Their RNA and protein expression levels in bone marrow mononuclear cells from myeloma cell lines U266, NCI-H929, MM.1s, RPMI8226 and leukemia cell line THP1, as well as 31 MM patients were evaluated by RT-PCR and Western blot, respectively. Meanwhile, 5 samples of bone marrow from healthy donors for allogeneic hematopoietic stem cell transplantation were employed as controls.
RESULTS:
Compared with leukemia cell line THP1, the expression levels of KCNN3, PARM1 and Sel1L mRNA were significantly increased in myeloma cell lines U266, NCI-H929 and MM.1s, while PARM1 was further increased in myeloma cell lines 8226. Western blot showed that the 4 genes were all expressed in the 4 myeloma cell lines. Compared with healthy controls, the expression levels of Sel1L, SPAG4, KCNN3 and PARM1 mRNA were significantly higher in MM patients (all P < 0.05). Western blot showed that the 4 genes were all expressed in MM patients, and the protein expression level of Sel1L and KCNN3 were significantly different compared with healthy donors (all P < 0.01).
CONCLUSION
Sel1L, SPAG4, KCNN3 and PARM1 may be potential diagnostic markers and therapeutic targets for MM.
Humans
;
Multiple Myeloma/genetics*
;
Cell Line, Tumor
;
Proteins/metabolism*
;
Computational Biology
;
RNA, Messenger/genetics*
5.Significance of precise classification of sacral meningeal cysts by multiple dimensions radiographic reconstruction MRI in guiding operative strategy and rehabilitation.
Jianjun SUN ; Qianquan MA ; Xiaoliang YIN ; Chenlong YANG ; Jia ZHANG ; Suhua CHEN ; Chao WU ; Jingcheng XIE ; Yunfeng HAN ; Guozhong LIN ; Yu SI ; Jun YANG ; Haibo WU ; Qiang ZHAO
Journal of Peking University(Health Sciences) 2025;57(2):303-308
OBJECTIVE:
To precise classify sacral meningeal cysts, effective guide minimally invasive neurosurgery and postoperative personalized rehabilitation by multiple dimensions radiographic reconstruction MRI.
METHODS:
From March to December 2021, based on the original 3D-fast imaging employing steadystate acquisition (FIESTA) scanning sequence, 92 patients with sacral meningeal cysts were pre-operatively evaluated by multiple dimensional reconstruction MRI. The shape of nerve root and the leakage of cyst were reconstructed according to the direction of nerve root or leakage track showed on original MRI scans. Sacral canal cysts were accurately classified as including nerve root and without nerve root, so as to accurately design the incision of skin and formulate corresponding open range of the posterior wall of the sacral canal. Under the microscope intraoperation, the shape of the nerve roots inside cysts or leakage track of the cysts without nerve roots were verified and explored. After the reinforcement and shaping operation, several reexaminations of multiple dimensional reconstruction MRI were performed to understand the deformation of the nerve root and hydrops in the operation cavity, so as to formulate a persona-lized rehabilitation plan for the patients.
RESULTS:
Among the 92 patients with sacral mengingeal cyst, 58 (63.0%) cysts with nerve root cyst, 29 (31.5%) cysts without nerve root cyst, and 5 (5.4%) cysts with mixed sacral canal cyst. In 58 patients with nerve root cysts, the accuracy of preoperative clinical classification on MRI image reached 96.6% (56/58) through confirmation by operating microscope. Only 2 cases of large single cyst with nerve root on the head of cyst were mistaken for without nerve root type. In 29 patients with sacral cyst without nerve root, the accuracy of preoperative image reached 100% through confirmation by operating microscope. The accuracy of judging the internal nerve root and leakage of 12 cases with recurrent sacral cyst was also 100%. Two cases of delayed postoperative hydrops were found one month after operation. After rehabilitation treatment by moxibustion and bathing, the hydrops disappeared 4-6 months after operation.
CONCLUSION
Multiple dimensional reconstruction MRI can precisely make clinical classification of sacral meningeal cysts before operation, guide minimally invasive neurosurgery effectively, and improve the rehabilitation effect.
Humans
;
Magnetic Resonance Imaging/methods*
;
Male
;
Female
;
Sacrum/surgery*
;
Adult
;
Middle Aged
;
Imaging, Three-Dimensional/methods*
;
Cysts/rehabilitation*
;
Aged
;
Adolescent
;
Young Adult
;
Spinal Nerve Roots/diagnostic imaging*
;
Minimally Invasive Surgical Procedures
;
Neurosurgical Procedures/methods*
6.A practice guideline for therapeutic drug monitoring of mycophenolic acid for solid organ transplants.
Shuang LIU ; Hongsheng CHEN ; Zaiwei SONG ; Qi GUO ; Xianglin ZHANG ; Bingyi SHI ; Suodi ZHAI ; Lingli ZHANG ; Liyan MIAO ; Liyan CUI ; Xiao CHEN ; Yalin DONG ; Weihong GE ; Xiaofei HOU ; Ling JIANG ; Long LIU ; Lihong LIU ; Maobai LIU ; Tao LIN ; Xiaoyang LU ; Lulin MA ; Changxi WANG ; Jianyong WU ; Wei WANG ; Zhuo WANG ; Ting XU ; Wujun XUE ; Bikui ZHANG ; Guanren ZHAO ; Jun ZHANG ; Limei ZHAO ; Qingchun ZHAO ; Xiaojian ZHANG ; Yi ZHANG ; Yu ZHANG ; Rongsheng ZHAO
Journal of Zhejiang University. Science. B 2025;26(9):897-914
Mycophenolic acid (MPA), the active moiety of both mycophenolate mofetil (MMF) and enteric-coated mycophenolate sodium (EC-MPS), serves as a primary immunosuppressant for maintaining solid organ transplants. Therapeutic drug monitoring (TDM) enhances treatment outcomes through tailored approaches. This study aimed to develop an evidence-based guideline for MPA TDM, facilitating its rational application in clinical settings. The guideline plan was drawn from the Institute of Medicine and World Health Organization (WHO) guidelines. Using the Delphi method, clinical questions and outcome indicators were generated. Systematic reviews, Grading of Recommendations Assessment, Development, and Evaluation (GRADE) evidence quality evaluations, expert opinions, and patient values guided evidence-based suggestions for the guideline. External reviews further refined the recommendations. The guideline for the TDM of MPA (IPGRP-2020CN099) consists of four sections and 16 recommendations encompassing target populations, monitoring strategies, dosage regimens, and influencing factors. High-risk populations, timing of TDM, area under the curve (AUC) versus trough concentration (C0), target concentration ranges, monitoring frequency, and analytical methods are addressed. Formulation-specific recommendations, initial dosage regimens, populations with unique considerations, pharmacokinetic-informed dosing, body weight factors, pharmacogenetics, and drug-drug interactions are covered. The evidence-based guideline offers a comprehensive recommendation for solid organ transplant recipients undergoing MPA therapy, promoting standardization of MPA TDM, and enhancing treatment efficacy and safety.
Mycophenolic Acid/administration & dosage*
;
Drug Monitoring/methods*
;
Humans
;
Organ Transplantation
;
Immunosuppressive Agents/administration & dosage*
;
Delphi Technique
7.Sirtuin 3 Attenuates Acute Lung Injury by Decreasing Ferroptosis and Inflammation through Inhibiting Aerobic Glycolysis.
Ke Wei QIN ; Qing Qing JI ; Wei Jun LUO ; Wen Qian LI ; Bing Bing HAO ; Hai Yan ZHENG ; Chao Feng HAN ; Jian LOU ; Li Ming ZHAO ; Xing Ying HE
Biomedical and Environmental Sciences 2025;38(9):1161-1167
8.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
9.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.
10.Comparative Analysis of Energy Consumption and Electricity Use between Thulium Fiber Laser Devices and Holmium Laser Devices For Treatment of Benign Prostate Hyperplasia
Xiao LIU ; Chao ZUO ; Xiang CHEN ; Yunwen ZHAO ; Sitong LI ; Jun TIAN ; Kai ZHANG
Chinese Hospital Management 2024;44(11):85-87,90
Objective It compared the power consumption and electrical parameters between Thulium fiber laser devices(TFL)and Holmium laser devices(HoL)in transurethral enucleation of prostate(TUEP).Methods A sin-gle surgeon conducted TUEP by THL or HoL in 10 patients respectively.The enucleation efficiency,the laser energy output and the electric parameters were recorded and analyzed.Results The data from both groups of surgeries were tested for normal distribution,and the t-test found that the difference in the enucleation efficiency between the two surgeries was not statistically significant(P=0.818),and the energy consumption indexes of the two devices were comparable.The difference in the total kilojoules of laser emission between the two lasers during surgery was not statistically significant(P=0.148),but the power consumption of the thulium laser was about one-tenth of that of the holmium laser(P<0.001),suggesting that the former utilised electrical energy significantly more efficiently than the latter.The maximum current of the HoL was significantly higher than that of the TFL(P<0.001),requiring a spe-cial high-power power outlet.Conclusion TFL was superior to HoL in terms of lower power consumption,higher en-ergy-efficient and electrical convenient in transurethral enucleation of the prostate.

Result Analysis
Print
Save
E-mail