1.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
7.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
8.Newly Developed Sex-Specific Z Score Model for Coronary Artery Diameter in a Pediatric Population
Jeong Jin YU ; Hee Joung CHOI ; Hwa Jin CHO ; Sung Hye KIM ; Eun Jung CHEON ; Gi Beom KIM ; Lucy Youngmin EUN ; Se Yong JUNG ; Hyun Ok JUN ; Hyang-Ok WOO ; Sin-Ae PARK ; Soyoung YOON ; Hoon KO ; Ji-Eun BAN ; Jong-Woon CHOI ; Min Seob SONG ; Ji Whan HAN
Journal of Korean Medical Science 2024;39(16):e144-
Background:
This study aimed to generate a Z score calculation model for coronary artery diameter of normal children and adolescents to be adopted as the standard calculation method with consensus in clinical practice.
Methods:
This study was a retrospective, multicenter study that collected data from multiple institutions across South Korea. Data were analyzed to determine the model that best fit the relationship between the diameter of coronary arteries and independent demographic parameters. Linear, power, logarithmic, exponential, and square root polynomial models were tested for best fit.
Results:
Data of 2,030 subjects were collected from 16 institutions. Separate calculation models for each sex were developed because the impact of demographic variables on the diameter of coronary arteries differs according to sex. The final model was the polynomial formula with an exponential relationship between the diameter of coronary arteries and body surface area using the DuBois formula.
Conclusion
A new coronary artery diameter Z score model was developed and is anticipated to be applicable in clinical practice. The new model will help establish a consensus-based Z score model.
9.The Association of CHADS-P2A2RC Risk Score With Clinical Outcomes in Patients Taking P2Y12 Inhibitor Monotherapy After 3 Months of Dual Antiplatelet Therapy Following Percutaneous Coronary Intervention
Pil Sang SONG ; Seok-Woo SEONG ; Ji-Yeon KIM ; Soo Yeon AN ; Mi Joo KIM ; Kye Taek AHN ; Seon-Ah JIN ; Jin-Ok JEONG ; Jeong Hoon YANG ; Joo-Yong HAHN ; Hyeon-Cheol GWON ; Woo Jin JANG ; Hyuck Jun YOON ; Jang-Whan BAE ; Woong Gil CHOI ; Young Bin SONG
Korean Circulation Journal 2024;54(4):189-200
Background and Objectives:
Concerns remain that early aspirin cessation may be associated with potential harm in subsets at high risk of ischemic events. This study aimed to assess the effects of P2Y12 inhibitor monotherapy after 3-month dual antiplatelet therapy (DAPT) vs.prolonged DAPT (12-month or longer) based on the ischemic risk stratification, the CHADSP2A2RC, after percutaneous coronary intervention (PCI).
Methods:
This was a sub-study of the SMART-CHOICE trial. The effect of the randomized antiplatelet strategies was assessed across 3 CHADS-P2A2RC risk score categories. The primary outcome was a major adverse cardiac and cerebral event (MACCE), a composite of all-cause death, myocardial infarction, or stroke.
Results:
Up to 3 years, the high CHADS-P2A2RC risk score group had the highest incidence of MACCE (105 [12.1%], adjusted hazard ratio [HR], 2.927; 95% confidence interval [CI], 1.358–6.309; p=0.006) followed by moderate-risk (40 [1.4%], adjusted HR, 1.786; 95% CI, 0.868–3.674; p=0.115) and low-risk (9 [0.5%], reference). In secondary analyses, P2Y12 inhibitor monotherapy reduced the Bleeding Academic Research Consortium (BARC) types 2, 3, or 5 bleeding without increasing the risk of MACCE as compared with prolonged DAPT across the 3 CHADS-P2A2RC risk strata without significant interaction term (interaction p for MACCE=0.705 and interaction p for BARC types 2, 3, or 5 bleeding=0.055).
Conclusions
The CHADS-P2A2RC risk score is valuable in discriminating high-ischemicrisk patients. Even in such patients with a high risk of ischemic events, P2Y12 inhibitor monotherapy was associated with a lower incidence of bleeding without increased risk of ischemic events compared with prolonged DAPT.
10.Safety and Efficacy of Everolimus-Eluting Bioresorbable Vascular Scaffold Versus Second-Generation Drug-Eluting Stents in Real-World Practice
Joo Myung LEE ; Hyun Sung JOH ; Ki Hong CHOI ; David HONG ; Taek Kyu PARK ; Jeong Hoon YANG ; Young Bin SONG ; Jin-Ho CHOI ; Seung-Hyuk CHOI ; Jin-Ok JEONG ; Jong-Young LEE ; Young Jin CHOI ; Jei-Keon CHAE ; Seung-Ho HUR ; Jang-Whan BAE ; Ju-Hyeon OH ; Kook-Jin CHUN ; Hyun-Joong KIM ; Byung Ryul CHO ; Doosup SHIN ; Seung Hun LEE ; Doyeon HWANG ; Hyun-Jong LEE ; Ho-Jun JANG ; Hyun Kuk KIM ; Sang Jin HA ; Eun-Seok SHIN ; Joon-Hyung DOH ; Joo-Yong HAHN ; Hyeon-Cheol GWON ; On behalf of the SMART-REWARD Investigators
Journal of Korean Medical Science 2023;38(5):e34-
Background:
The risk of device thrombosis and device-oriented clinical outcomes with bioresorbable vascular scaffold (BVS) was reported to be significantly higher than with contemporary drug-eluting stents (DESs). However, optimal device implantation may improve clinical outcomes in patients receiving BVS. The current study evaluated mid-term safety and efficacy of Absorb BVS with meticulous device optimization under intravascular imaging guidance.
Methods:
The SMART-REWARD and PERSPECTIVE-PCI registries in Korea prospectively enrolled 390 patients with BVS and 675 patients with DES, respectively. The primary endpoint was target vessel failure (TVF) at 2 years and the secondary major endpoint was patientoriented composite outcome (POCO) at 2 years.
Results:
Patient-level pooled analysis evaluated 1,003 patients (377 patients with BVS and 626 patients with DES). Mean scaffold diameter per lesion was 3.24 ± 0.30 mm in BVS group.Most BVSs were implanted with pre-dilatation (90.9%), intravascular imaging guidance (74.9%), and post-dilatation (73.1%) at proximal to mid segment (81.9%) in target vessel.Patients treated with BVS showed comparable risks of 2-year TVF (2.9% vs. 3.7%, adjusted hazard ratio [HR], 1.283, 95% confidence interval [CI], 0.487–3.378, P = 0.615) and 2-year POCO (4.5% vs. 5.9%, adjusted HR, 1.413, 95% CI, 0.663–3.012,P = 0.370) than those with DES. The rate of 2-year definite or probable device thrombosis (0.3% vs. 0.5%, P = 0.424) was also similar. The sensitivity analyses consistently showed comparable risk of TVF and POCO between the 2 groups.
Conclusion
With meticulous device optimization under imaging guidance and avoidance of implantation in small vessels, BVS showed comparable risks of 2-year TVF and device thrombosis with DES.

Result Analysis
Print
Save
E-mail