1.Pericapsular Nerve Group Block with Periarticular Injection for Pain Management after Total Hip Arthroplasty: A Randomized Controlled Trial
Hun Sik CHO ; Bo Ra LEE ; Hyuck Min KWON ; Jun Young PARK ; Hyeong Won HAM ; Woo-Suk LEE ; Kwan Kyu PARK ; Tae Sung LEE ; Yong Seon CHOI
Yonsei Medical Journal 2025;66(4):233-239
Purpose:
The purpose of this study was to compare the effectiveness of pericapsular nerve group (PENG) block with periarticular multimodal drug injection (PMDI) on postoperative pain management and surgical outcomes in patients who underwent total hip arthroplasty (THA). We hypothesized that PENG block with PMDI would exhibit superior effects on postoperative pain control after THA compared to PMDI alone.
Materials and Methods:
From April 2022 to February 2023, 58 patients who underwent THA were randomly assigned into two groups: PENG block with PMDI group (n=29) and PMDI-only group (n=29). Primary outcomes were postoperative numeric rating scale (NRS) at rest and during activity at 6, 24, and 48 hours postoperatively. Secondary outcomes were postoperative complications (nausea and vomiting), Richards-Campbell Sleep Questionnaire (RCSQ) score, length of hospital stay, Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index, Harris Hip Score (HHS), and total morphine usage after surgery.
Results:
There was no significant difference in postoperative pain for either resting NRS or active NRS. Postoperative nausea and vomiting, RCSQ score, length of hospital stay, WOMAC index, HHS, and total morphine usage exhibited no significant differences between the two groups.
Conclusion
Both groups showed no significant differences in postoperative pain and clinical outcomes, indicating that the addition of PENG block to PMDI does not improve pain management after applying the posterolateral approach of THA. PMDI alone during THA would be an efficient, fast, and safe method for managing postoperative pain. This article was registered with ClinicalTrials.gov (Gov ID: NCT05320913).
2.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
3.First report of iron-overload myopathy due to secondary hemochromatosis in a dog
Jae-Hyuk YIM ; Tae-Un KIM ; Woo Jun KIM ; Seulgi BAE ; Sungho YUN ; Su-Min BAEK ; Jin-Kyu PARK
Journal of Veterinary Science 2025;26(1):e3-
and Relevance: Severe necrosis and mild fibrosis were observed in the liver and forelimb skeletal muscles. Based on histological analysis, we diagnosed iron overload myopathy by secondary hemochromatosis. Secondary hemochromatosis with severe muscle atrophy and myositis is very rare, and this is the first report of iron-overload myopathy in a dog.
4.Sex Differences in Procedural Characteristics and Clinical Outcomes Among Patients Undergoing Bifurcation PCI
Hyun Jin AHN ; Francesco BRUNO ; Jeehoon KANG ; Doyeon HWANG ; Han-Mo YANG ; Jung-Kyu HAN ; Leonardo De LUCA ; Ovidio de FILIPPO ; Alessio MATTESINI ; Kyung Woo PARK ; Alessandra TRUFFA ; Wojciech WANHA ; Young Bin SONG ; Sebastiano GILI ; Woo Jung CHUN ; Gerard HELFT ; Seung-Ho HUR ; Bernardo CORTESE ; Seung Hwan HAN ; Javier ESCANED ; Alaide CHIEFFO ; Ki Hong CHOI ; Guglielmo GALLONE ; Joon-Hyung DOH ; Gaetano De FERRARI ; Soon-Jun HONG ; Giorgio QUADRI ; Chang-Wook NAM ; Hyeon-Cheol GWON ; Hyo-Soo KIM ; Fabrizio D’ASCENZO ; Bon-Kwon KOO
Korean Circulation Journal 2025;55(1):5-16
Background and Objectives:
The risk profiles, procedural characteristics, and clinical outcomes for women undergoing bifurcation percutaneous coronary intervention (PCI) are not well defined compared to those in men.
Methods:
COronary BIfurcation Stenting III (COBIS III) is a multicenter, real-world registry of 2,648 patients with bifurcation lesions treated with second-generation drug-eluting stents.We compared the angiographic and procedural characteristics and clinical outcomes based on sex. The primary outcome was 5-year target lesion failure (TLF), a composite of cardiac death, myocardial infarction, and target lesion revascularization.
Results:
Women (n=635, 24%) were older, had hypertension and diabetes more often, and had smaller main vessel and side branch reference diameters than men. The pre- and post-PCI angiographic percentage diameter stenoses of the main vessel and side branch were comparable between women and men. There were no differences in procedural characteristics between the sexes. Women and men had a similar risk of TLF (6.3% vs. 7.1%, p=0.63) as well as its individual components and sex was not an independent predictor of TLF. This finding was consistent in the left main and 2 stenting subgroups.
Conclusions
In patients undergoing bifurcation PCI, sex was not an independent predictor of adverse outcome.
5.Comparison of intraoperative neurophysiological monitoring between propofol and remimazolam during total intravenous anesthesia in the cervical spine surgery: a prospective, double-blind, randomized controlled trial
Myoung Hwa KIM ; Jinyoung PARK ; Yoon Ghil PARK ; Yong Eun CHO ; Dawoon KIM ; Dong Jun LEE ; Kyu Wan KWAK ; Jongyun LEE ; Dong Woo HAN
Korean Journal of Anesthesiology 2025;78(1):16-29
Background:
Although total intravenous anesthesia (TIVA) with propofol and remifentanil is frequently used to optimize intraoperative neurophysiological monitoring (IONM), the exact effect of remimazolam on IONM remains unknown. Here, we compared the effects of propofol and remimazolam along with remifentanil on IONM during TIVA.
Methods:
In this prospective, double-blind, randomized controlled trial, 64 patients requiring IONM during cervical spine surgery were administered either propofol (Group P) or remimazolam (Group R). The preoperative latencies of the somatosensory-evoked potentials (SEP; N20 for the median nerve and P37 for the tibial nerve) were measured. SEP latencies and amplitudes and motor-evoked potential (MEP) amplitudes were measured 30 min after anesthetic induction (T1), 30 min after surgical incision (T2), after laminectomy or discectomy (T3), immediately after plate insertion or pedicle screw fixation (T4), and before surgical wound closure (T5). The primary outcome was the between-group difference in the N20 latency changes measured at T1 and preoperatively.
Results:
The change in SEP latencies including N20 and P37 at T1 compared with preoperative time was not significantly different between Groups P and R. Except for the amplitude of the right abductor brevis, there was no significant group-by-time interaction effect for intraoperative MEP amplitudes or SEP latencies and amplitudes.
Conclusions
TIVA with remimazolam and remifentanil for cervical spine surgery yielded stable IONM, comparable to those observed with conventional TIVA with propofol and remifentanil. Further clinical trials are needed in other surgical contexts and with more diverse patient populations to determine the effects of remimazolam on IONM.
6.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
7.Reduction Loss Despite Adequate Volar Locking Plate Fixation in Distal Radius Fractures: Analysis of Characteristics and Follow-up Management
Chi-Hoon OH ; Seungyeon KANG ; Sung Woo LEE ; Soo-Hong HAN ; Jun-Ku LEE
Clinics in Orthopedic Surgery 2025;17(3):478-487
Background:
The management of distal radius fractures (DRFs) has evolved with the introduction of volar locking plate (VLP) fixation.Nevertheless, despite the low occurrence rates, reduction loss following VLP fixation has been reported in several studies. Our objective was to determine the incidence and features of reduction loss in patients despite the appropriate application of VLP fixation for DRF.
Methods:
This retrospective study was conducted between March 2017 and August 2023, during which a single hand surgeon performed VLP procedures for DRFs. This study included 379 patients (382 wrists) including 3 patients who underwent bilateral surgery. We identified patients who experienced reduction loss after VLP fixation (group 1) and patients without stability problems (group 2) and compared the 2 groups.
Results:
The mean age of the patients was 63.5 years, with a standard deviation of 13.8. There were 90 male patients (23.6%) and 289 female patients (75.7%). We identified 14 cases of DRFs, in which reduction loss occurred even after VLP fixation during the follow-up period (group 1, 3.7%). The remaining DRFs were assigned to group 2 (n=368, 96.3%). Among the 14 patients, 7 cases of screw breakage were identified as causing the loss of fracture reduction. As the joint surface collapsed and sank down to the distal row locking screw, 4 cases presented with distal locking screws penetrating into the radiocarpal joint. There were no significant differences between the 2 groups in terms of sex, weight, fracture arm direction, and Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) fracture classification. However, patients in group 1 were statistically significantly older than those in group 2 (average age, 77.5 years vs. 62 years). Among 4 patients experiencing distal screw violation of the radiocarpal joints, 3 underwent partial or complete screw removal immediately after fracture consolidation or union.
Conclusions
While rare, reduction loss remains a potential complication following VLP fixation, especially in elderly patients with intra-articular DRFs. However, with diligent monitoring and timely intervention, such as implant removal if necessary, acceptable outcomes can still be attained.
8.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
9.A Narrative Review on the Double Pulley-Triple Row Technique for Large to Massive Rotator Cuff Repair
Vivek Kumar MORYA ; Jun LANG ; Yong-beom LEE ; Jung Woo KIM ; Kang Uk LEE ; Kyu-Cheol NOH
Clinics in Orthopedic Surgery 2025;17(3):359-371
Rotator cuff tears are common shoulder injuries that often necessitate surgical intervention, particularly when nonoperative treatments fail. Arthroscopic rotator cuff repair is the current gold standard; however, challenges, such as high retear rates, especially in large tears, persist. Traditional techniques, such as single-row and double-row repairs, have limitations in fully restoring the anatomical footprint and ensuring optimal healing. This review examines the novel double pulley-triple row technique, which aims to overcome these limitations by enhancing the footprint contact area, load distribution, and tendon healing. By evaluating the double pulley-triple row method in comparison to established techniques, this study explores the potential advantages, limitations, and future directions of rotator cuff repair.
10.Reproducibility of Plasma Biomarker Measurements Across Laboratories:Insights Into ptau217, GFAP, and NfL
Heekyoung KANG ; Sook-Young WOO ; Daeun SHIN ; Sohyun YIM ; Eun Hye LEE ; Hyunchul RYU ; Bora CHU ; Henrik ZETTERBERG ; Kaj BLENNOW ; Jihwan YUN ; Duk L NA ; Hee Jin KIM ; Hyemin JANG ; Jun Pyo KIM ;
Dementia and Neurocognitive Disorders 2025;24(2):91-101
Background:
and Purpose: Plasma biomarkers, including phosphorylated tau (ptau217), glial fibrillary acidic protein (GFAP), and neurofilament light chain (NfL), are promising tools for detecting Alzheimer’s disease (AD) pathology. However, cross-laboratory reproducibility remains a challenge, even when using identical analytical platforms such as single-molecule array (Simoa). This study aimed to compare plasma biomarker measurements (ptau217, GFAP, and NfL) between 2 laboratories, the University of Gothenburg (UGOT) and DNAlink, and evaluate their associations with amyloid positron emission tomography (PET) imaging.
Methods:
Plasma biomarkers were measured using Simoa platforms at both laboratories:the UGOT and DNAlink Incorporation. Diagnostic performance for predicting amyloid PET positivity, cross-laboratory agreement, and the impact of normalization techniques were assessed. Bland-Altman plots and correlation analyses were employed to evaluate agreement and variability.
Results:
Plasma ptau217 concentrations exhibited strong correlations with amyloid PET global centiloid values, with comparable diagnostic performance between laboratories (area under the curve=0.94 for UGOT and 0.95 for DNAlink). Cross-laboratory agreement for ptau217 was excellent (r=0.96), improving further after natural log transformation. GFAP and NfL also demonstrated moderate to strong correlations (r=0.86 for GFAP and r=0.99 for NfL), with normalization reducing variability.
Conclusions
Plasma biomarker measurements were consistent across laboratories using identical Simoa platforms, with strong diagnostic performance and improved agreement after normalization. These findings support the scalability of plasma biomarkers for multicenter studies and underscore their potential for standardized applications in AD research and clinical practice.

Result Analysis
Print
Save
E-mail