1.Multi-component Quality Consistency Evaluation of Leonuri Herba Granules Based on HPLC-DAD-CAD Multi-detector Technique and Chemometrics
Shuangyan LI ; Jun ZHANG ; Cong GUO ; Siyuan LI ; Jipeng DI ; Jiangmin SU ; An LIU ; Xiaodi KOU ; Yan LIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(8):174-181
ObjectiveTo systematically evaluate the content differences of 4 components in Leonuri Herba granules, reveal the quality fluctuation patterns of products from the same and different manufacturers, providing scientific basis for the optimization of production process and quality control. MethodsHigh performance liquid chromatography-diode array detector-charged aerosol detector(HPLC-DAD-CAD) was employed to determine the contents of 4 components(syringic acid, leonurine hydrochloride, ferulic acid, and stachydrine hydrochloride) in samples from 19 manufacturers(53 batches, 159 boxes). Additionally, fingerprint profiles were constructed, and the fingerprint dissimilarity(PS) and relative standard deviation(RSD) of different samples from the same manufacturer were calculated. A principal component analysis(PCA) model was established with PS and the RSD values of the 4 components as variables to classify the manufacturers. Finally, samples from 5 manufacturers(M1-M5) covering three consistency groups were selected to calculate three quality consistency parameters, namely intra-batch consistency(PA), inter-batch consistency(PB), and PS. Then, PCA was performed with PA, PB, and PS of these 5 manufacturers as variables. ResultsThe average total content of the 4 index components per bag across the 19 manufacturers ranged from 41.10 mg to 97.54 mg. Among them, the content of stachydrine hydrochloride(a pharmacopoeial quality control component) was 32.46-72.70 mg per bag, all meeting the requirements of the 2025 edition of the Pharmacopoeia of the People's Republic of China, with RSD of 1.7%-17.1%. The content ranges of the other 3 components were as follows:syringic acid of 1.43-41.92 mg per bag, leonurine hydrochloride of 0.67-11.85 mg per bag, and ferulic acid of 0.11-3.81 mg per bag. Notably, leonurine hydrochloride exhibited the most significant content fluctuation among samples from the same manufacturer(RSD of 4.8%-59.2%). PCA results showed that the 19 manufacturers could be classified into 3 categories. Samples from 8 manufacturers(M2, M6, M7, M8, M10, M15, M17, M18) demonstrated relatively high consistency, five manufacturers(M3, M9, M12, M13, M14) showed moderate consistency, six manufacturers(M1, M4, M5, M11, M16, M19) exhibited low consistency. The two methods yielded consistent classification results for the 5 representative manufacturers, verifying the reliability of the proposed method. Among these, manufacturer M2 showed the best quality consistency and the highest total content of indicator components among M1-M5. ConclusionThe HPLC-DAD-CAD multi-detector hyphenation technology established in this study enables the accurate detection of 4 components in Leonuri Herba granules. Significant differences in the total content of these four components are observed among products from 19 manufacturers. The application of 2 consistency evaluation methods combined with PCA can effectively classify their consistency into 3 categories, and the classification results of the 2 methods are highly consistent. This study provides scientific basis for the process optimization and quality standard improvement of Leonuri Herba granules.
2.Multi-component Quality Consistency Evaluation of Leonuri Herba Granules Based on HPLC-DAD-CAD Multi-detector Technique and Chemometrics
Shuangyan LI ; Jun ZHANG ; Cong GUO ; Siyuan LI ; Jipeng DI ; Jiangmin SU ; An LIU ; Xiaodi KOU ; Yan LIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(8):174-181
ObjectiveTo systematically evaluate the content differences of 4 components in Leonuri Herba granules, reveal the quality fluctuation patterns of products from the same and different manufacturers, providing scientific basis for the optimization of production process and quality control. MethodsHigh performance liquid chromatography-diode array detector-charged aerosol detector(HPLC-DAD-CAD) was employed to determine the contents of 4 components(syringic acid, leonurine hydrochloride, ferulic acid, and stachydrine hydrochloride) in samples from 19 manufacturers(53 batches, 159 boxes). Additionally, fingerprint profiles were constructed, and the fingerprint dissimilarity(PS) and relative standard deviation(RSD) of different samples from the same manufacturer were calculated. A principal component analysis(PCA) model was established with PS and the RSD values of the 4 components as variables to classify the manufacturers. Finally, samples from 5 manufacturers(M1-M5) covering three consistency groups were selected to calculate three quality consistency parameters, namely intra-batch consistency(PA), inter-batch consistency(PB), and PS. Then, PCA was performed with PA, PB, and PS of these 5 manufacturers as variables. ResultsThe average total content of the 4 index components per bag across the 19 manufacturers ranged from 41.10 mg to 97.54 mg. Among them, the content of stachydrine hydrochloride(a pharmacopoeial quality control component) was 32.46-72.70 mg per bag, all meeting the requirements of the 2025 edition of the Pharmacopoeia of the People's Republic of China, with RSD of 1.7%-17.1%. The content ranges of the other 3 components were as follows:syringic acid of 1.43-41.92 mg per bag, leonurine hydrochloride of 0.67-11.85 mg per bag, and ferulic acid of 0.11-3.81 mg per bag. Notably, leonurine hydrochloride exhibited the most significant content fluctuation among samples from the same manufacturer(RSD of 4.8%-59.2%). PCA results showed that the 19 manufacturers could be classified into 3 categories. Samples from 8 manufacturers(M2, M6, M7, M8, M10, M15, M17, M18) demonstrated relatively high consistency, five manufacturers(M3, M9, M12, M13, M14) showed moderate consistency, six manufacturers(M1, M4, M5, M11, M16, M19) exhibited low consistency. The two methods yielded consistent classification results for the 5 representative manufacturers, verifying the reliability of the proposed method. Among these, manufacturer M2 showed the best quality consistency and the highest total content of indicator components among M1-M5. ConclusionThe HPLC-DAD-CAD multi-detector hyphenation technology established in this study enables the accurate detection of 4 components in Leonuri Herba granules. Significant differences in the total content of these four components are observed among products from 19 manufacturers. The application of 2 consistency evaluation methods combined with PCA can effectively classify their consistency into 3 categories, and the classification results of the 2 methods are highly consistent. This study provides scientific basis for the process optimization and quality standard improvement of Leonuri Herba granules.
3.Analysis of Quality Uniformity of Hengzhi Kechuan Capsules Based on HPLC-DAD-CAD
Qian MA ; An LIU ; Qingxia XU ; Cong GUO ; Jun ZHANG ; Maoqing WANG ; Xiaodi KOU ; Yan LIU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(3):168-174
ObjectiveTo establish the fingerprints of 15 batches of Hengzhi Kechuan capsules, to quantitatively analyze 10 index components, and to evaluate the quality uniformity of samples from different batches. MethodsThe fingerprints and quantitative analysis of Hengzhi Kechuan capsules were established by a combination method of high performance liquid chromatography coupled with diode array detector and charged aerosol detector(HPLC-DAD-CAD), adenosine, guanosine, vanillic acid, safflomin A, agarotetrol, naringin, hesperidin, militarine, ginsenoside Rb1, and glycyrrhizic acid were selected as quality attribute indexes. A total of 15 batches of Hengzhi Kechuan capsules from 2022 to 2024(3 boxes per batch) were qualitatively and quantitatively analyzed, and the quality uniformity level of the manufacturers was characterized by parameters of intra-batch consistency(PA) and inter-batch consistency(PB). The homogeneity and difference of quality attribute indexes of samples from different years were analyzed by heatmap clustering analysis. ResultsHPLC fingerprints and quantitative method of Hengzhi Kechuan capsules were established, and the methods could be used for qualitative and quantitative analysis of this preparation, which was found to be stable and reliable by method validation. The similarity of fingerprints of 15 batches of samples was 0.887-0.975, a total of 13 common peaks were calibrated, and 10 common peaks were designated, all of which were quality attribute index components. The results of quantitative analysis showed that the contents of the above 10 ingredients in the samples were 0.038-0.078, 0.115-0.251, 0.007-0.018, 0.291-0.673, 0.122-0.257, 0.887-1.905, 1.841-3.364, 1.412-2.450, 2.207-3.112, 0.650-1.161, respectively. And the contents of ginsenoside Rb1 and glycyrrhizic acid met the limit requirements in the 2020 edition of Chinese Pharmacopoeia. For the samples from 15 batches, the PA values of the 10 index components were all <10%, indicating good intra-batch homogeneity, and the PB values ranged from 33.86% to 92.97%, suggesting that the inter-batch homogeneity was poor. Heatmap clustering analysis showed that the samples from different years were clustered into separate categories, and adenosine, guanosine, safflomin A, naringin, hesperidin and agarotetrol were the main differential components. ConclusionThe intra-annual quality uniformity of Hengzhi Kechuan capsules is good and the inter-annual quality uniformity is insufficient, which may be related to the quality difference of Pinellinae Rhizoma Praeparatum, Carthami Flos, Citri Sarcodactylis Fructus, Citri Reticulatae Pericarpium, Aquilariae Lignum Resinatum, Citri Fructus, etc. In this study, the fingerprint and multi-indicator determination method of Hengzhi Kechuan capsules was established, which can be used for more accurate and efficient quality control and standardization enhancement.
4.Associations between Pesticide Metabolites and Decreased Estimated Glomerular Filtration Rate Among Solar Greenhouse Workers: A Specialized Farmer Group.
Teng Long YAN ; Xin SONG ; Xiao Dong LIU ; Wu LIU ; Yong Lan CHEN ; Xiao Mei ZHANG ; Xiang Juan MENG ; Bin Shuo HU ; Zhen Xia KOU ; Tian CHEN ; Xiao Jun ZHU
Biomedical and Environmental Sciences 2025;38(2):265-269
5.Consensus on informed consent for orthodontic treatment
Yang CAO ; Bing FANG ; Zuolin JIN ; Hong HE ; Yuxing BAI ; Lin WANG ; Haiping LU ; Zhihe ZHAO ; Tianmin XU ; Weiran LI ; Min HU ; Jinlin SONG ; Jun WANG ; Fang JIN ; Ding BAI ; Xianglong HAN ; Yuehua LIU ; Bin YAN ; Jie GUO ; Jiejun SHI ; Yongming LI ; Zhihua LI ; Xiuping WU ; Jiangtian HU ; Linyu XU ; Lin LIU ; Yi LIU ; Yanqin LU ; Wensheng MA ; Shuixue MO ; Liling REN ; Shuxia CUI ; Yongjie FAN ; Jianguang XU ; Lulu XU ; Zhijun ZHENG ; Peijun WANG ; Rui ZOU ; Chufeng LIU ; Lunguo XIA ; Li HU ; Weicai WANG ; Liping WU ; Xiaoxing KOU ; Jiali TAN ; Yuanbo LIU ; Bowen MENG ; Yuantao HAO ; Lili CHEN
Chinese Journal of Stomatology 2025;60(12):1327-1336
This consensus was developed by the Orthodontic Society of the Chinese Stomatological Association to provide a systematic, scientific, and practical guideline for informed consent in orthodontic care. Orthodontic treatment is typically lengthy, highly individualized, and involves multiple factors such as growth and development, occlusal function, and facial esthetics. Rapid technological advances and diverse risk profiles make the traditional reliance on orthodontist experience or institutional templates insufficient to ensure patients′ full understanding and autonomous decision-making. To address this, the expert panel conducted extensive reviews of domestic and international guidelines, analyzed representative dispute cases, and performed multicenter patient-clinician surveys. Using a multi-round Delphi method, the group established a standardized informed consent framework covering the initial consultation, treatment, and retention phases. The consensus emphasizes that informed consent is not only a fundamental legal and ethical requirement but also a key step in building trust, improving patient compliance, and enhancing treatment satisfaction. Orthodontists should clearly and comprehensively explain treatment plans, potential risks, uncertainties, and associated costs, while respecting the autonomy of patients or guardians, and maintain continuous communication and dynamic evaluation throughout the treatment process. The release of this consensus provides unified and authoritative guidance for clinical orthodontics, helping to standardize informed consent, enhance its transparency, safeguard patient rights, reduce medical risks, and promote high-quality, sustainable development of orthodontic practice.
6.Correlation between Serum Ferritin Levels and the Efficacy of Platelet Transfusion in Patients with Malignant Hematological Diseases
Yi-Yao LI ; Xiao-Yun GAO ; Hang GUAN ; Yu BAI ; Jun-Hui JIA ; Wei BAI ; Yan-Hui DI ; Hua TIAN ; Li-Duo KOU ; Xin-Hua WANG
Journal of Experimental Hematology 2025;33(6):1779-1783
Objective:To explore the correlation between serum ferritin(SF)levels and the efficacy of platelet transfusion in patients with malignant hematological diseases.Methods:Patients with malignant hematological diseases who received repeated transfusions of apheresis platelets in Department of Hematology of Aerospace Center Hospital in 2023 were selected.The platelet corrected count increment(CCI)was used to evaluate the efficacy of platelet transfusion.The correlations between sex,age,disease type,transplantation history,red blood cell transfusion history,and SF level and the efficacy of platelet transfusion were analyzed.Results:A total of 87 patients were included,with a cumulative 326 person-times platelet transfusions.As suggested by one-way analysis of variance,compared with the patients in the age groups of 24-45 years old and 46-66 years old,the patients in the age group of 2-23 years old had a better efficacy of platelet transfusion(P=0.004,P=0.004).There was no significant difference in the efficacy of platelet transfusion between the patients in the age group of 24-45 years old and those in the age group of 46-66 years old(P=0.876).Compared with the patients who had a history of red blood cell transfusion within 3 days,the patients without a history of red blood cell transfusion within 3 days had a better efficacy of platelet transfusion(P<0.001).Compared with the groups with SF levels of 1.44-2.78 ng/L and>2.78 ng/L,the group with SF levels<1.44 ng/L had a better efficacy of platelet transfusion(P=0.028,P<0.001).Compared with the group with SF levels>2.78 ng/L,the group with SF levels of 1.44-2.78 ng/L had a better efficacy of platelet transfusion(P=0.001).After adjusting for age and the history of red blood cell transfusion,the transfusion efficacy of the group with SF levels<1.44 ng/L was better than that of the groups with SF levels of 1.44-2.78 ng/L and>2.78 ng/L(P=0.021,P<0.001);Compared with the group with SF levels>2.78 ng/L,the group with SF levels of 1.44-2.78 ng/L had a better efficacy of platelet transfusion(P=0.001).Both univariate and multivariate linear regression models showed that SF levels were negatively correlated with the efficacy of platelet transfusion(P<0.001).Conclusion:There is a negative correlation between SF levels and the efficacy of platelet transfusion in patients with malignant hematological diseases.Detection of SF levels may provide guidance for predicting the efficacy of platelet transfusion.
7.Consensus on informed consent for orthodontic treatment
Yang CAO ; Bing FANG ; Zuolin JIN ; Hong HE ; Yuxing BAI ; Lin WANG ; Haiping LU ; Zhihe ZHAO ; Tianmin XU ; Weiran LI ; Min HU ; Jinlin SONG ; Jun WANG ; Fang JIN ; Ding BAI ; Xianglong HAN ; Yuehua LIU ; Bin YAN ; Jie GUO ; Jiejun SHI ; Yongming LI ; Zhihua LI ; Xiuping WU ; Jiangtian HU ; Linyu XU ; Lin LIU ; Yi LIU ; Yanqin LU ; Wensheng MA ; Shuixue MO ; Liling REN ; Shuxia CUI ; Yongjie FAN ; Jianguang XU ; Lulu XU ; Zhijun ZHENG ; Peijun WANG ; Rui ZOU ; Chufeng LIU ; Lunguo XIA ; Li HU ; Weicai WANG ; Liping WU ; Xiaoxing KOU ; Jiali TAN ; Yuanbo LIU ; Bowen MENG ; Yuantao HAO ; Lili CHEN
Chinese Journal of Stomatology 2025;60(12):1327-1336
This consensus was developed by the Orthodontic Society of the Chinese Stomatological Association to provide a systematic, scientific, and practical guideline for informed consent in orthodontic care. Orthodontic treatment is typically lengthy, highly individualized, and involves multiple factors such as growth and development, occlusal function, and facial esthetics. Rapid technological advances and diverse risk profiles make the traditional reliance on orthodontist experience or institutional templates insufficient to ensure patients′ full understanding and autonomous decision-making. To address this, the expert panel conducted extensive reviews of domestic and international guidelines, analyzed representative dispute cases, and performed multicenter patient-clinician surveys. Using a multi-round Delphi method, the group established a standardized informed consent framework covering the initial consultation, treatment, and retention phases. The consensus emphasizes that informed consent is not only a fundamental legal and ethical requirement but also a key step in building trust, improving patient compliance, and enhancing treatment satisfaction. Orthodontists should clearly and comprehensively explain treatment plans, potential risks, uncertainties, and associated costs, while respecting the autonomy of patients or guardians, and maintain continuous communication and dynamic evaluation throughout the treatment process. The release of this consensus provides unified and authoritative guidance for clinical orthodontics, helping to standardize informed consent, enhance its transparency, safeguard patient rights, reduce medical risks, and promote high-quality, sustainable development of orthodontic practice.
8.Correlation between Serum Ferritin Levels and the Efficacy of Platelet Transfusion in Patients with Malignant Hematological Diseases
Yi-Yao LI ; Xiao-Yun GAO ; Hang GUAN ; Yu BAI ; Jun-Hui JIA ; Wei BAI ; Yan-Hui DI ; Hua TIAN ; Li-Duo KOU ; Xin-Hua WANG
Journal of Experimental Hematology 2025;33(6):1779-1783
Objective:To explore the correlation between serum ferritin(SF)levels and the efficacy of platelet transfusion in patients with malignant hematological diseases.Methods:Patients with malignant hematological diseases who received repeated transfusions of apheresis platelets in Department of Hematology of Aerospace Center Hospital in 2023 were selected.The platelet corrected count increment(CCI)was used to evaluate the efficacy of platelet transfusion.The correlations between sex,age,disease type,transplantation history,red blood cell transfusion history,and SF level and the efficacy of platelet transfusion were analyzed.Results:A total of 87 patients were included,with a cumulative 326 person-times platelet transfusions.As suggested by one-way analysis of variance,compared with the patients in the age groups of 24-45 years old and 46-66 years old,the patients in the age group of 2-23 years old had a better efficacy of platelet transfusion(P=0.004,P=0.004).There was no significant difference in the efficacy of platelet transfusion between the patients in the age group of 24-45 years old and those in the age group of 46-66 years old(P=0.876).Compared with the patients who had a history of red blood cell transfusion within 3 days,the patients without a history of red blood cell transfusion within 3 days had a better efficacy of platelet transfusion(P<0.001).Compared with the groups with SF levels of 1.44-2.78 ng/L and>2.78 ng/L,the group with SF levels<1.44 ng/L had a better efficacy of platelet transfusion(P=0.028,P<0.001).Compared with the group with SF levels>2.78 ng/L,the group with SF levels of 1.44-2.78 ng/L had a better efficacy of platelet transfusion(P=0.001).After adjusting for age and the history of red blood cell transfusion,the transfusion efficacy of the group with SF levels<1.44 ng/L was better than that of the groups with SF levels of 1.44-2.78 ng/L and>2.78 ng/L(P=0.021,P<0.001);Compared with the group with SF levels>2.78 ng/L,the group with SF levels of 1.44-2.78 ng/L had a better efficacy of platelet transfusion(P=0.001).Both univariate and multivariate linear regression models showed that SF levels were negatively correlated with the efficacy of platelet transfusion(P<0.001).Conclusion:There is a negative correlation between SF levels and the efficacy of platelet transfusion in patients with malignant hematological diseases.Detection of SF levels may provide guidance for predicting the efficacy of platelet transfusion.
9.Quercetin inhibits the activity of neuroendocrine tumor cells by regulating the GAS5/miR-18b-5p axis
Wen-Juan WU ; Bo LI ; Hai-Hong LÜ ; Jun CHEN ; Wen KOU
The Chinese Journal of Clinical Pharmacology 2024;40(10):1429-1433
Objective To investigate the inhibitory effect of quercetin on Gastro entero pancreatic NEN(GEP-NEN).Methods Human pancreatic neuroendocrine tumor BON-1 cells were randomly divided into control group,quercetin group(80 μmol·L-1 quercetin),quercetin+si-NC group(transfected with si-NC+80 μmol·L-1 quercetin),quercetin+si-growth arrest-specific+ranscript 5(GAS5)group(transfected with si-GAS5+80 μmol·L-1 quercetin).Dual luciferase reporter gene assay was used to verify the targeted binding of GASS5 to miR-18b-5p;real-time quantitative fluorescent PCR(qRT-PCR)was used to detect the mRNA expression levels of B-cell lymphoma-2(Bcl-2)and Bel-2 associated X protein(Bax);positive expression of GAS5 and miR-18b-5p in cells was detected by fluorescence in situ hybridization(FISH)assay.Results Dual luciferase reporter gene results showed that GAS5 was targeted to miR-18b-5p.The GAS5 expression levels of control group,quercetin group,quercetin+si-NC group and quercetin+si-GAS5 group were 1.00±0.13,1.72±0.19,1.78±0.14 and 1.16±0.11,respectively;the expression levels of miR-18b-5p were 1.00±0.15,0.67±0.08,0.72±0.06 and 0.95±0.11 respectively;Bax mRNA expression levels were 1.00±0.12,2.17±0.25,2.32±0.28 and 1.37±0.15,respectively;Bcl-2 mRNA expression levels were 1.00±0.15,0.41±0.05,0.37±0.06 and 1.21±0.13,respectively.The above indexes were significantly different between quercetin group and control group(all P<0.05);the above indexes were significantly different between quercetin+si-NC group and quercetin+si-GAS5 group(all P<0.05).Conclusion Quercetin may slow down the development of GEP-NEN by targeting GAS5/miR-18b-5p molecular axis to inhibit cell growth.
10.Ablation ranges of single and double needle microwave ablation of pig lung in vivo
Na KOU ; Fuliang LUO ; Hongli LI ; Jun TENG ; Mengfei ZHAO ; Ronghua JIANG ; Mengyuan ZHAO ; Hongwu WANG
Chinese Journal of Interventional Imaging and Therapy 2024;21(8):491-494
Objective To compare ablation ranges of single and double needle microwave ablation(MWA)of pig lung in vivo.Methods Five healthy Bama miniature pigs were enrolled.Single needle(single needle group)and parallel double needle MWA(double needle group)were performed successively on bilateral lungs,respectively.Adverse event during MWA was evaluated according to common terminology criteria for adverse events(CTCAE).The long diameter(D1CT),short diameter(D2CT),longitudinal diameter(D3CT)and volume(V)of ablation foci were measured and calculated based on CT images immediately after MWA,whereas D1,s D2s and sphericity of ablation foci were also obtained based on specimen and compared between groups.Results D1CT,D2CT,D3CT and V,as well as D1S,D2S and sphericity of ablation foci in single needle group were all significantly smaller than those in double needle group(all P<0.01).Mild pneumothorax(CTCAE grade 1)was found in 1 pig(1/5,20.00%)in single needle group,while mild pneumothorax and pulmonary hemorrhage(both CTCAE grade 1)occurred in 1 pig(1/5,20.00%)in double needle group.No other adverse event was observed.Conclusion Compared with single needle MWA,double needle MWA of pig lung in vivo resulted larger ablation range and more spherically shaped ablation foci.

Result Analysis
Print
Save
E-mail