1.A customized guide device for single needle arthrocentesis on temporomandibular joint
Jun-Hyung JEON ; Sang-Hee PARK ; Pil-Young YUN ; Jeong-Kui KU
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2025;51(2):95-101
Objectives:
This study aims to evaluate the accuracy and effectiveness of temporomandibular joint (TMJ) arthrocentesis using the three-dimensional (3D)-printed TMJ injection guide in cases of hemarthrosis caused by condyle fractures.
Materials and Methods:
A retrospective chart review was conducted for patients treated with the customized TMJ arthrocentesis guide to address hemarthrosis. Inclusion criteria included adults older than 18 years with condylar fractures not indicated for open reduction and internal fixation. The guide was fabricated using computed tomography or cone-beam computed tomography scans and 3D printing to control the degree and depth of the needle through the guide to aspirate hemarthrosis.
Results:
Six joints from five patients (average age 52.4 years) were treated using the guide. Post-procedural magnetic resonance imaging confirmed complete resolution of hemarthrosis in all cases. A representative case demonstrated successful outcomes with normal healing and no complications at 8 months post-procedure.
Conclusion
The customized TMJ injection guide, using ear-based reference points, significantly enhances the accuracy and safety of TMJ arthrocentesis. This innovation is expected to increase the accessibility and effectiveness of TMJ-related treatments for clinicians without specialized TMJ expertise.
2.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
3.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
4.A customized guide device for single needle arthrocentesis on temporomandibular joint
Jun-Hyung JEON ; Sang-Hee PARK ; Pil-Young YUN ; Jeong-Kui KU
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2025;51(2):95-101
Objectives:
This study aims to evaluate the accuracy and effectiveness of temporomandibular joint (TMJ) arthrocentesis using the three-dimensional (3D)-printed TMJ injection guide in cases of hemarthrosis caused by condyle fractures.
Materials and Methods:
A retrospective chart review was conducted for patients treated with the customized TMJ arthrocentesis guide to address hemarthrosis. Inclusion criteria included adults older than 18 years with condylar fractures not indicated for open reduction and internal fixation. The guide was fabricated using computed tomography or cone-beam computed tomography scans and 3D printing to control the degree and depth of the needle through the guide to aspirate hemarthrosis.
Results:
Six joints from five patients (average age 52.4 years) were treated using the guide. Post-procedural magnetic resonance imaging confirmed complete resolution of hemarthrosis in all cases. A representative case demonstrated successful outcomes with normal healing and no complications at 8 months post-procedure.
Conclusion
The customized TMJ injection guide, using ear-based reference points, significantly enhances the accuracy and safety of TMJ arthrocentesis. This innovation is expected to increase the accessibility and effectiveness of TMJ-related treatments for clinicians without specialized TMJ expertise.
5.Development of a Standardized Suicide Prevention Program for Gatekeeper Intervention in Korea (Suicide CARE Version 2.0) to Prevent Adolescent Suicide: Version for Teachers
Hyeon-Ah LEE ; Yeon Jung LEE ; Kyong Ah KIM ; Myungjae BAIK ; Jong-Woo PAIK ; Jinmi SEOL ; Sang Min LEE ; Eun-Jin LEE ; Haewoo LEE ; Meerae LIM ; Jin Yong JUN ; Seon Wan KI ; Hong Jin JEON ; Sun Jung KWON ; Hwa-Young LEE
Psychiatry Investigation 2025;22(1):117-117
6.Memory Decline and Aberration of Synaptic Proteins in X-Linked Moesin Knockout Male Mice
Hua CAI ; Seong Mi LEE ; Yura CHOI ; Bomlee LEE ; Soo Jung IM ; Dong Hyeon KIM ; Hyung Jun CHOI ; Jin Hee KIM ; Yeni KIM ; Boo Ahn SHIN ; Songhee JEON
Psychiatry Investigation 2025;22(1):10-25
Objective:
This study aims to investigate may moesin deficiency resulted in neurodevelopmental abnormalities caused by negative impact on synaptic signaling ultimately leading to synaptic structure and plasticity.
Methods:
Behavioral assessments measured neurodevelopment (surface righting, negative geotaxis, cliff avoidance), anxiety (open field test, elevated plus maze test), and memory (passive avoidance test, Y-maze test) in moesin-knockout mice (KO) compared to wild-type mice (WT). Whole exome sequencing (WES) of brain (KO vs. WT) and analysis of synaptic proteins were performed to determine the disruption of signal pathways downstream of moesin. Risperidone, a therapeutic agent, was utilized to reverse the neurodevelopmental aberrance in moesin KO.
Results:
Moesin-KO pups exhibited decrease in the surface righting ability on postnatal day 7 (p<0.05) and increase in time spent in the closed arms (p<0.01), showing increased anxiety-like behavior. WES revealed mutations in pathway aberration in neuron projection, actin filament-based processes, and neuronal migration in KO. Decreased cell viability (p<0.001) and expression of soluble NSF adapter protein 25 (SNAP25) (p<0.001) and postsynaptic density protein 95 (PSD95) (p<0.01) was observed in days in vitro 7 neurons. Downregulation of synaptic proteins, and altered phosphorylation levels of Synapsin I, mammalian uncoordinated 18 (MUNC18), extracellular signal-regulated kinase (ERK), and cAMP response element-binding protein (CREB) was observed in KO cortex and hippocampus. Risperidone reversed the memory impairment in the passive avoidance test and the spontaneous alternation percentage in the Y maze test. Risperidone also restored the reduced expression of PSD95 (p<0.01) and the phosphorylation of Synapsin at Ser605 (p<0.05) and Ser549 (p<0.001) in the cortex of moesin-KO.
Conclusion
Moesin deficiency leads to neurodevelopmental delay and memory decline, which may be caused through altered regulation in synaptic proteins and function.
7.The impact of CYP2D6 on donepezil concentration and its lack of effect on the treatment response and adverse effect in Korean patients with Alzheimer’s disease
Tae-Eun KIM ; Jung‑Woo BAE ; Seongkuk HONG ; Hong Jun JEON ; Yeonsil MOON
The Korean Journal of Physiology and Pharmacology 2025;29(2):227-233
Donepezil, an acetylcholinesterase inhibitor, is widely used for managing the symptoms of Alzheimer’s disease (AD), yet its clinical response varies widely among individuals. This study aims to investigate the influence of CYP2D6 genetic variants on donepezil concentration, treatment response, and adverse effects in Korean patients with AD dementia. We conducted a longitudinal study involving 76 patients receiving either 5 mg or 10 mg of donepezil. Genetic testing identified 9 CYP2D6 alleles, categorizing patients by metabolizing abilities. Blood sampling for plasma concentrations of donepezil were performed at steady-state. Mini-Mental State Examination (MMSE) were conducted at 12, 24 and 36 months after the initiation of treatment. Adverse events were collected throughout the study period.Donepezil plasma concentrations differed significantly among metabolizer statuses (mean 56.8 ± 27.1 ng/ml in normal metabolizers vs. 69.6 ± 30.1 ng/ml in intermediate metabolizers, p = 0.042), but these differences did not affect cognitive function over three years as assessed by MMSE. Additionally, there was no significant correlation between donepezil plasma concentration and adverse events. Our study is the first to elucidate the associations between CYP2D6 genotype and the concentration, clinical response or adverse events of donepezil in Korean patients with AD dementia. Larger studies are necessary to fully understand the impact of CYP2D6 genetic variants on therapeutic outcomes with donepezil.
8.Cannabidiol Alleviates Chronic Prostatitis and Chronic Pelvic Pain Syndrome via CB2 Receptor Activation and TRPV1 Desensitization
Jun Jie PIAO ; Soomin KIM ; Dongho SHIN ; Hwa Jong LEE ; Kyung-Hwa JEON ; Wen Jie TIAN ; Kyung Jae HUR ; Jong Soo KANG ; Hyun-Je PARK ; Joo Young CHA ; Aeri SONG ; Sang-Hyuck PARK ; Mahadevan RAJASEKARAN ; Woong Jin BAE ; Sungjoo KIM YOON ; Sae Woong KIM
The World Journal of Men's Health 2025;43(1):228-238
Purpose:
This study elucidates the mechanism of the physiological effect of cannabidiol (CBD) by assessing its impact on lipopolysaccharide (LPS)-induced inflammation in RWPE-1 cells and prostatitis-induced by 17β-estradiol and dihydrotestosterone in a rat model, focusing on its therapeutic potential for chronic prostatitis/chronic pelvic pain syndrome (CP/CPPS).
Materials and Methods:
RWPE-1 cells were stratified in vitro into three groups: (1) controls, (2) cells with LPS-induced inflammation, and (3) cells with LPS-induced inflammation and treated with CBD. Enzyme-linked immunosorbent assays and western blots were performed on cellular components and supernatants after administration of CBD. Five groups of six Sprague–Dawley male rats were assigned: (1) control, (2) CP/CPPS, (3) CP/CPPS and treated with 50 mg/kg CBD, (4) CP/CPPS and treated with 100 mg/kg CBD, and (5) CP/CPPS and treated with 150 mg/kg CBD. Prostatitis was induced through administration of 17β-estradiol and dihydrotestosterone. After four weeks of CBD treatment, a pain index was evaluated, and prostate tissue was collected for subsequent histologic examination and western blot analysis.
Results:
CBD demonstrated efficacy in vivo for CP/CPPS and in vitro for inflammation. It inhibited the toll-like receptor 4 (TLR4)uclear factor-kappa B (NF-κB) pathway by activating the CB2 receptor, reducing expression of interleukin-6, tumor necrosis factor-alpha, and cyclooxygenase-2 (COX2) (p<0.01). CBD exhibited analgesic effects by activating and desensitizing the TRPV1 receptor.
Conclusions
CBD inhibits the TLR4/NF-κB pathway by activating the CB2 receptor, desensitizes the TRPV1 receptor, and decreases the release of COX2. This results in relief of inflammation and pain in patients with CP/CPPS, indicating CBD as a potential treatment for CP/CPPS.
9.High-Dose Rifampicin for 3 Months after Culture Conversion for Drug-Susceptible Pulmonary Tuberculosis
Nakwon KWAK ; Joong-Yub KIM ; Hyung-Jun KIM ; Byoung-Soo KWON ; Jae Ho LEE ; Jeongha MOK ; Yong-Soo KWON ; Young Ae KANG ; Youngmok PARK ; Ji Yeon LEE ; Doosoo JEON ; Jung-Kyu LEE ; Jeong Seong YANG ; Jake WHANG ; Kyung Jong KIM ; Young Ran KIM ; Minkyoung CHEON ; Jiwon PARK ; Seokyung HAHN ; Jae-Joon YIM
Tuberculosis and Respiratory Diseases 2025;88(1):170-180
Background:
This study aimed to determine whether a shorter high-dose rifampicin regimen is non-inferior to the standard 6-month tuberculosis regimen.
Methods:
This multicenter, randomized, open-label, non-inferiority trial enrolled participants with respiratory specimen positivity by Xpert MTB/RIF assay or Mycobacterium tuberculosis culture without rifampicin-resistance. Participants were randomized at 1:1 to the investigational or control group. The investigational group received high-dose rifampicin (30 mg/kg/day), isoniazid, and pyrazinamide until culture conversion, followed by high-dose rifampicin and isoniazid for 12 weeks. The control group received the standard 6-month regimen. The primary outcome was the rate of unfavorable outcomes at 18 months post-randomization. The non-inferiority margin was set at <6% difference in unfavorable outcomes rates. The study is registered with ClinicalTrials.gov (NCT04485156)
Results:
Between 4 November 2020 and 3 January 2022, 76 participants were enrolled. Of these, 58 were included in the modified intention-to-treat analysis. Unfavorable outcomes occurred in 10 (31.3%) of 32 in the control group and 10 (38.5%) of 26 in the investigational group. The difference was 7.2% (95% confidence interval, ∞ to 31.9%), failing to prove non-inferiority. Serious adverse events and grade 3 or higher adverse events did not differ between the groups.
Conclusion
The shorter high-dose rifampicin regimen failed to demonstrate non-inferiority but had an acceptable safety profile.
10.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.

Result Analysis
Print