1.Knee Morphology and Proximal Tibial Bone Quality around the Posterior Cruciate Ligament Insertion Site Affect Injury Patterns
Young Tak CHO ; Jong Hwa LEE ; Jun Hyeok YOON ; Seok Ho HONG ; Joong Il KIM
Clinics in Orthopedic Surgery 2025;17(3):400-407
Background:
Several studies have investigated the morphological risk factors contributing to posterior cruciate ligament (PCL) injury. However, no study has focused on the injury patterns of intrasubstance tears or tibial avulsion fractures in relation to morphologies and regional bone quality. This study aimed to investigate the impact of the knee morphology and regional bone quality of the proximal tibia on the PCL injury pattern.
Methods:
This retrospective study compared the radiological features of 76 patients with PCL injuries (PI group) and 76 matched patients with normal PCL (control group). The PI group was divided into 2 subgroups: PCL avulsion fracture (PAF subgroup; n = 43) and PCL intrasubstance tear (PIT subgroup; n = 33). Measurements included the coronal notch width index, coronal tibial slope, medial and lateral posterior tibial slopes, and medial tibial depth. Three Hounsfield unit average measurements were taken from the proximal tibia around the PCL insertion site to create a summative measure of overall bone quality.
Results:
The medial tibial depth and coronal notch width index were significantly lower in the PI group than those in the control group (medial tibial depth: 2.04 ± 0.77 vs. 3.02 ± 1.04, p = 0.017; coronal notch width index: 0.21 ± 0.03 vs. 0.24 ± 0.03, p = 0.041). In the subgroup analysis, medial tibial depth and Hounsfield unit were significantly lower in the PAF subgroup than in the PIT subgroup (medial tibial depth: 1.74 ± 0.66 vs. 2.43 ± 0.77, p = 0.008, Hounsfield unit: 89.48 ± 31.73 vs. 120.15 ± 29.24, p = 0.004). Binary logistic regression analysis showed that medial tibial depth (odds ratio [OR], 0.161; p < 0.001) and Hounsfield unit (OR, 0.950;p < 0.001) were independent risk factors for PCL tibial avulsion fractures.
Conclusions
Lower notch width index and medial tibial depth are associated with PCL injuries. Shallower medial tibial depth and lower Hounsfield unit measurements around the PCL insertion site were associated with an increased incidence of PCL avulsion fractures. These findings may assist clinicians in identifying patients at risk of distinct PCL injury patterns.
2.Nipple swab culture profile as a potential predictor of postoperative complications in autologous breast reconstruction: a retrospective study
Sun-Hyeok KIM ; Yi-Jun MOON ; Seung-Pil JUNG ; Hyung-Chul LEE ; Jae-Ho CHUNG ; Eul-Sik YOON
Archives of Aesthetic Plastic Surgery 2025;31(2):35-40
Background:
The nipple is a potential source of pathogens because its lactiferous ducts act as direct conduits from the nipple–areolar complex to the breast parenchyma. Our previous studies identified breast microbiota as a factor in postoperative complications following immediate breast reconstruction using silicone implants and acellular dermal matrix. This study aimed to investigate the correlation between preoperative nipple swab microbiota and the incidence of surgical site infections (SSIs) after autologous breast reconstruction.
Methods:
We conducted a retrospective chart review of patients who underwent autologous breast reconstruction following total mastectomy. Preoperative nipple swab cultures were obtained. Patient demographics, surgical characteristics, and complication rates were compared between culture-positive and culture-negative groups. Microbiological data, including antibiotic‑resistance profiles, were collected.
Results:
Among 39 reconstructed breasts, 18 (46.9%) had positive preoperative nipple cultures. The mean duration of drain placement was significantly longer in the culture‑positive group (14.39±3.96 days) than in the culture‑negative group (12.14±2.76 days, P=0.045). Methicillin‑susceptible Staphylococcus epidermidis accounted for 55.0% of isolates. Of the four SSIs observed, three occurred in patients with positive preoperative cultures.
Conclusions
Although pathogen strains differed between preoperative and postoperative settings, obtaining preoperative nipple microflora cultures and determining antibiotic‑resistance profiles can guide immediate antibiotic selection for SSIs and enhance postoperative management.
3.Nipple swab culture profile as a potential predictor of postoperative complications in autologous breast reconstruction: a retrospective study
Sun-Hyeok KIM ; Yi-Jun MOON ; Seung-Pil JUNG ; Hyung-Chul LEE ; Jae-Ho CHUNG ; Eul-Sik YOON
Archives of Aesthetic Plastic Surgery 2025;31(2):35-40
Background:
The nipple is a potential source of pathogens because its lactiferous ducts act as direct conduits from the nipple–areolar complex to the breast parenchyma. Our previous studies identified breast microbiota as a factor in postoperative complications following immediate breast reconstruction using silicone implants and acellular dermal matrix. This study aimed to investigate the correlation between preoperative nipple swab microbiota and the incidence of surgical site infections (SSIs) after autologous breast reconstruction.
Methods:
We conducted a retrospective chart review of patients who underwent autologous breast reconstruction following total mastectomy. Preoperative nipple swab cultures were obtained. Patient demographics, surgical characteristics, and complication rates were compared between culture-positive and culture-negative groups. Microbiological data, including antibiotic‑resistance profiles, were collected.
Results:
Among 39 reconstructed breasts, 18 (46.9%) had positive preoperative nipple cultures. The mean duration of drain placement was significantly longer in the culture‑positive group (14.39±3.96 days) than in the culture‑negative group (12.14±2.76 days, P=0.045). Methicillin‑susceptible Staphylococcus epidermidis accounted for 55.0% of isolates. Of the four SSIs observed, three occurred in patients with positive preoperative cultures.
Conclusions
Although pathogen strains differed between preoperative and postoperative settings, obtaining preoperative nipple microflora cultures and determining antibiotic‑resistance profiles can guide immediate antibiotic selection for SSIs and enhance postoperative management.
4.Knee Morphology and Proximal Tibial Bone Quality around the Posterior Cruciate Ligament Insertion Site Affect Injury Patterns
Young Tak CHO ; Jong Hwa LEE ; Jun Hyeok YOON ; Seok Ho HONG ; Joong Il KIM
Clinics in Orthopedic Surgery 2025;17(3):400-407
Background:
Several studies have investigated the morphological risk factors contributing to posterior cruciate ligament (PCL) injury. However, no study has focused on the injury patterns of intrasubstance tears or tibial avulsion fractures in relation to morphologies and regional bone quality. This study aimed to investigate the impact of the knee morphology and regional bone quality of the proximal tibia on the PCL injury pattern.
Methods:
This retrospective study compared the radiological features of 76 patients with PCL injuries (PI group) and 76 matched patients with normal PCL (control group). The PI group was divided into 2 subgroups: PCL avulsion fracture (PAF subgroup; n = 43) and PCL intrasubstance tear (PIT subgroup; n = 33). Measurements included the coronal notch width index, coronal tibial slope, medial and lateral posterior tibial slopes, and medial tibial depth. Three Hounsfield unit average measurements were taken from the proximal tibia around the PCL insertion site to create a summative measure of overall bone quality.
Results:
The medial tibial depth and coronal notch width index were significantly lower in the PI group than those in the control group (medial tibial depth: 2.04 ± 0.77 vs. 3.02 ± 1.04, p = 0.017; coronal notch width index: 0.21 ± 0.03 vs. 0.24 ± 0.03, p = 0.041). In the subgroup analysis, medial tibial depth and Hounsfield unit were significantly lower in the PAF subgroup than in the PIT subgroup (medial tibial depth: 1.74 ± 0.66 vs. 2.43 ± 0.77, p = 0.008, Hounsfield unit: 89.48 ± 31.73 vs. 120.15 ± 29.24, p = 0.004). Binary logistic regression analysis showed that medial tibial depth (odds ratio [OR], 0.161; p < 0.001) and Hounsfield unit (OR, 0.950;p < 0.001) were independent risk factors for PCL tibial avulsion fractures.
Conclusions
Lower notch width index and medial tibial depth are associated with PCL injuries. Shallower medial tibial depth and lower Hounsfield unit measurements around the PCL insertion site were associated with an increased incidence of PCL avulsion fractures. These findings may assist clinicians in identifying patients at risk of distinct PCL injury patterns.
5.Knee Morphology and Proximal Tibial Bone Quality around the Posterior Cruciate Ligament Insertion Site Affect Injury Patterns
Young Tak CHO ; Jong Hwa LEE ; Jun Hyeok YOON ; Seok Ho HONG ; Joong Il KIM
Clinics in Orthopedic Surgery 2025;17(3):400-407
Background:
Several studies have investigated the morphological risk factors contributing to posterior cruciate ligament (PCL) injury. However, no study has focused on the injury patterns of intrasubstance tears or tibial avulsion fractures in relation to morphologies and regional bone quality. This study aimed to investigate the impact of the knee morphology and regional bone quality of the proximal tibia on the PCL injury pattern.
Methods:
This retrospective study compared the radiological features of 76 patients with PCL injuries (PI group) and 76 matched patients with normal PCL (control group). The PI group was divided into 2 subgroups: PCL avulsion fracture (PAF subgroup; n = 43) and PCL intrasubstance tear (PIT subgroup; n = 33). Measurements included the coronal notch width index, coronal tibial slope, medial and lateral posterior tibial slopes, and medial tibial depth. Three Hounsfield unit average measurements were taken from the proximal tibia around the PCL insertion site to create a summative measure of overall bone quality.
Results:
The medial tibial depth and coronal notch width index were significantly lower in the PI group than those in the control group (medial tibial depth: 2.04 ± 0.77 vs. 3.02 ± 1.04, p = 0.017; coronal notch width index: 0.21 ± 0.03 vs. 0.24 ± 0.03, p = 0.041). In the subgroup analysis, medial tibial depth and Hounsfield unit were significantly lower in the PAF subgroup than in the PIT subgroup (medial tibial depth: 1.74 ± 0.66 vs. 2.43 ± 0.77, p = 0.008, Hounsfield unit: 89.48 ± 31.73 vs. 120.15 ± 29.24, p = 0.004). Binary logistic regression analysis showed that medial tibial depth (odds ratio [OR], 0.161; p < 0.001) and Hounsfield unit (OR, 0.950;p < 0.001) were independent risk factors for PCL tibial avulsion fractures.
Conclusions
Lower notch width index and medial tibial depth are associated with PCL injuries. Shallower medial tibial depth and lower Hounsfield unit measurements around the PCL insertion site were associated with an increased incidence of PCL avulsion fractures. These findings may assist clinicians in identifying patients at risk of distinct PCL injury patterns.
6.Knee Morphology and Proximal Tibial Bone Quality around the Posterior Cruciate Ligament Insertion Site Affect Injury Patterns
Young Tak CHO ; Jong Hwa LEE ; Jun Hyeok YOON ; Seok Ho HONG ; Joong Il KIM
Clinics in Orthopedic Surgery 2025;17(3):400-407
Background:
Several studies have investigated the morphological risk factors contributing to posterior cruciate ligament (PCL) injury. However, no study has focused on the injury patterns of intrasubstance tears or tibial avulsion fractures in relation to morphologies and regional bone quality. This study aimed to investigate the impact of the knee morphology and regional bone quality of the proximal tibia on the PCL injury pattern.
Methods:
This retrospective study compared the radiological features of 76 patients with PCL injuries (PI group) and 76 matched patients with normal PCL (control group). The PI group was divided into 2 subgroups: PCL avulsion fracture (PAF subgroup; n = 43) and PCL intrasubstance tear (PIT subgroup; n = 33). Measurements included the coronal notch width index, coronal tibial slope, medial and lateral posterior tibial slopes, and medial tibial depth. Three Hounsfield unit average measurements were taken from the proximal tibia around the PCL insertion site to create a summative measure of overall bone quality.
Results:
The medial tibial depth and coronal notch width index were significantly lower in the PI group than those in the control group (medial tibial depth: 2.04 ± 0.77 vs. 3.02 ± 1.04, p = 0.017; coronal notch width index: 0.21 ± 0.03 vs. 0.24 ± 0.03, p = 0.041). In the subgroup analysis, medial tibial depth and Hounsfield unit were significantly lower in the PAF subgroup than in the PIT subgroup (medial tibial depth: 1.74 ± 0.66 vs. 2.43 ± 0.77, p = 0.008, Hounsfield unit: 89.48 ± 31.73 vs. 120.15 ± 29.24, p = 0.004). Binary logistic regression analysis showed that medial tibial depth (odds ratio [OR], 0.161; p < 0.001) and Hounsfield unit (OR, 0.950;p < 0.001) were independent risk factors for PCL tibial avulsion fractures.
Conclusions
Lower notch width index and medial tibial depth are associated with PCL injuries. Shallower medial tibial depth and lower Hounsfield unit measurements around the PCL insertion site were associated with an increased incidence of PCL avulsion fractures. These findings may assist clinicians in identifying patients at risk of distinct PCL injury patterns.
7.Nipple swab culture profile as a potential predictor of postoperative complications in autologous breast reconstruction: a retrospective study
Sun-Hyeok KIM ; Yi-Jun MOON ; Seung-Pil JUNG ; Hyung-Chul LEE ; Jae-Ho CHUNG ; Eul-Sik YOON
Archives of Aesthetic Plastic Surgery 2025;31(2):35-40
Background:
The nipple is a potential source of pathogens because its lactiferous ducts act as direct conduits from the nipple–areolar complex to the breast parenchyma. Our previous studies identified breast microbiota as a factor in postoperative complications following immediate breast reconstruction using silicone implants and acellular dermal matrix. This study aimed to investigate the correlation between preoperative nipple swab microbiota and the incidence of surgical site infections (SSIs) after autologous breast reconstruction.
Methods:
We conducted a retrospective chart review of patients who underwent autologous breast reconstruction following total mastectomy. Preoperative nipple swab cultures were obtained. Patient demographics, surgical characteristics, and complication rates were compared between culture-positive and culture-negative groups. Microbiological data, including antibiotic‑resistance profiles, were collected.
Results:
Among 39 reconstructed breasts, 18 (46.9%) had positive preoperative nipple cultures. The mean duration of drain placement was significantly longer in the culture‑positive group (14.39±3.96 days) than in the culture‑negative group (12.14±2.76 days, P=0.045). Methicillin‑susceptible Staphylococcus epidermidis accounted for 55.0% of isolates. Of the four SSIs observed, three occurred in patients with positive preoperative cultures.
Conclusions
Although pathogen strains differed between preoperative and postoperative settings, obtaining preoperative nipple microflora cultures and determining antibiotic‑resistance profiles can guide immediate antibiotic selection for SSIs and enhance postoperative management.
8.Conventional machine learning-based prediction models did not outperform the International IgA Nephropathy Prediction Tool
Sehoon PARK ; Yisak KIM ; Chung Hee BAEK ; Hyunjeong CHO ; Ji In PARK ; Eun Sil KOH ; Jung Pyo LEE ; Sun-Hee PARK ; Hyung Woo KIM ; Seung Hyeok HAN ; Ho Jun CHIN ; Dong Ki KIM ; Kyung Chul MOON ; Young-Gon KIM ; Hajeong LEE
Kidney Research and Clinical Practice 2025;44(5):802-813
Immunoglobulin A nephropathy (IgAN) is a major cause of end-stage kidney disease (ESKD). The International IgA Nephropathy Prediction Tool (IIgAN-PT) predicts IgAN prognosis, but improvement in the prediction performance using machine learning (ML)-based methods is needed. Methods: We analyzed 4,425 biopsy-confirmed patients with IgAN and ≥6 months of follow-up from nine tertiary university hospitals in Korea. The study population was divided into development and validation cohorts. Using the collected 87 clinicodemographic and pathological variables, ML-based prediction models for ESKD or estimated glomerular filtration rate decline (50% reduction or <15 mL/min/1.73 m2 ) were constructed: 1) the conventional CatBoost model, 2) the optimized CatBoost model with Cox proportional hazards, 3) the deep Cox proportional hazards model, and 4) the deep Cox mixture model. The area under the curve (AUC) and calibration plots were used to investigate the discriminative and calibration performance of the models, which were then compared with those of the IIgAN-PT full model. Results: The full model showed excellent performance (AUC [95% confidence interval] for 5-year outcome, 0.896 [0.853–0.940]), with acceptable calibration results. The ML-based models showed good performance in predicting adverse kidney outcomes and revealed acceptable discrimination performance in the external validation (AUC [95% confidence interval] for the 5-year outcome: 1) 0.829 [0.791–0.866]; 2) 0.847 [0.804–0.890]; 3) 0.823 [0.784–0.862]; and 4) 0.832 [0.794–0.870]), although the models showed underestimation in calibration analysis of the external validation cohort. With the validation data, the overall performance of the IIgAN-PT was non-inferior to that of the ML-based model. Conclusions: Our ML-based models showed good performance in predicting adverse kidney outcomes in patients with IgAN but they did not outperform the IIgAN-PT.
9.No Change in Complications Following Thyroidectomy Despite Increase in Thyroid Cancer Surgeries: A Meta-Regression Analysis
Jun Sung LEE ; Jin Seok LEE ; Hyeok Jun YUN ; Seok-Mo KIM ; Hojin CHANG ; Yong Sang LEE ; Juyeon YANG ; Hye Sun LEE ; Hang-Seok CHANG
Yonsei Medical Journal 2024;65(6):348-355
Purpose:
The increase in thyroid cancer incidence has inevitably led to an increase in thyroid cancer surgeries. This meta-regression analysis aimed to determine if the rate of post-thyroidectomy complications changes by year.
Materials and Methods:
PubMed and Embase databases were used to perform a systematic literature search of studies published from January 1, 2005, using the keywords “thyroidectomy” and “complication.” A meta-regression was performed for post-thyroidectomy hypocalcemia and bleeding.
Results:
This meta-analysis included 25 studies involving 927751 individuals. Through the years of publications in this study, there was no significant difference in the proportion of post-thyroidectomy hypocalcemia and bleeding (p=0.9978, 0.6393).
Conclusion
Although the number of thyroid surgeries has recently increased, the incidence of post-thyroidectomy hypocalcemia and bleeding did not significantly increase.
10.Effects of a 2-Week Kinect-Based Mixed-Reality Exercise Program on Prediabetes: A Pilot Trial during COVID-19
So Young AHN ; Si Woo LEE ; Hye Jung SHIN ; Won Jae LEE ; Jun Hyeok KIM ; Hyun-Jun KIM ; Wook SONG
Journal of Obesity & Metabolic Syndrome 2024;33(1):54-63
Background:
Pre-diabetes can develop into type 2 diabetes mellitus, but can prevented by regular exercise.However, the outcomes when combining unsupervised Kinect-based mixed-reality (KMR) exercise with continuous glucose monitoring (CGM) remain unclear. Therefore, this single-arm pilot trial examined changes in blood glucose (BG) concentrations over 672 hours (4 weeks), including a 2-week period of KMR exercise and CGM in individuals with pre-diabetes.
Methods:
This was a pre-and post-treatment case-control study with nine participants. General questionnaires were administered and body composition, fasting BG concentrations, and 2-hour oral glucose tolerance test (2-OGTT) results were measured pre-and post-treatment. Weekly average glucose concentrations, hyperglycemia rate, hypoglycemia rate, average glucose concentration over time, amount of physical activity, amount of food intake, and pre- and postprandial BG (immediately and 30, 60, 90, and 120 minutes after lunch) were measured over 4 weeks (pre-test, exercise, and post -test weeks). Glucose concentrations were measured before exercising, between sets, and 30 and 60 minutes after exercise during the 2 weeks of unsupervised exercise (3 days/week).
Results:
In all participants, body mass index (27.16±2.92 kg/m²), fasting BG (108.00±7.19 mg/dL), 2-OGTT (162.56±18.12 mg/dL), hyperglycemia rate (P= 0.040), and 90-minute postprandial BG (P= 0.035) were significantly reduced during the 2 exercise weeks, and the 2-OGTT result (P= 0.044) and diastolic blood pressure (DBP) (P= 0.046) were significantly reduced at the post- test as compared with the pre-test.
Conclusion
This study found that 2 weeks of unsupervised KMR exercise reduced 2-OGTT, DBP, hyperglycemia rate, and 90-minute postprandial BG concentration. We believed this effect could be identified more clearly in studies involving a larger number of participants and longer durations of exercise.

Result Analysis