1.Guidelines for the Management of Adult Subglottic and Tracheal Stenosis From the Korean Bronchoesophagological Society
Jung-Hae CHO ; Gene HUH ; Jae-Keun CHO ; Jae Won CHANG ; Jun-Ook PARK ; Young Chan LEE ; Jae Hyun JEON ; Jeon Yeob JANG ; Byeong-Ho JEONG ; Yeon Soo KIM ; Inn-Chul NAM ; Gil Joon LEE ; Woo Sik YU ; Heejin KIM ; Minhyung LEE ; Ji Won KIM ; Seung Hoon WOO ; Il-Seok PARK ; Jin Pyeong KIM ;
Clinical and Experimental Otorhinolaryngology 2026;19(1):1-20
Subglottic stenosis (SGS) and tracheal stenosis (TS) are rare conditions that can cause significant breathing difficulties and, if not properly managed, may lead to life-threatening complications. Despite their clinical importance, debate continues regarding the optimal management of adult SGS and TS, and no comprehensive guidelines have been established to date. The Korean Bronchoesophagological Society appointed a task force to develop clinical practice guidelines with the goal of providing evidence-based recommendations for managing SGS and TS in adults. The task force conducted a systematic review of the relevant literature by searching PubMed, Embase, and the Cochrane Library using predefined search terms aligned with key clinical questions. The quality of evidence was assessed using the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) approach, which also informed the formulation and reporting of the recommendations. The strength of each recommendation reflects the guideline panel’s confidence that the benefits of an intervention outweigh its risks for eligible patients. After drafting the guidelines, feedback was obtained through Delphi questionnaires completed by members of the Korean Bronchoesophagological Society. Ultimately, the committee developed 17 evidence-based recommendations across four categories: initial evaluation, medical management, surgical treatment, and postoperative management and rehabilitation. These guidelines aim to support clinicians in delivering optimal care to adult patients with SGS and TS.
2.Clinicopathological Correlations of Neurodegenerative Diseases in the National Brain Biobank of Korea
Young Hee JUNG ; Jun Pyo KIM ; Hee Jin KIM ; Hyemin JANG ; Hyun Jeong HAN ; Young Ho KOH ; Duk L. NA ; Yeon-Lim SUH ; Gi Yeong HUH ; Jae-Kyung WON ; Seong-Ik KIM ; Ji-Young CHOI ; Sang Won SEO ; Sung-Hye PARK ; Eun-Joo KIM
Journal of Clinical Neurology 2025;21(3):190-200
Background:
and Purpose The National Brain Biobank of Korea (NBBK) is a brain bank consortium supported by the Korea Disease Control and Prevention Agency and the Korea National Institute of Health, and was launched in 2015 to support research into neurodegenerative disease dementia (NDD). This study aimed to introduce the NBBK and describes clinicopathological correlations based on analyses of data collected from the NBBK.
Methods:
Four hospital-based brain banks have been established in South Korea: Samsung Medical Center Brain Bank (SMCBB), Seoul National University Hospital Brain Bank (SNUHBB), Pusan National University Hospital Brain Bank (PNUHBB), and Myongji Hospital Brain Bank (MJHBB). Clinical and pathological data were collected from these brain banks using standardized protocols. The prevalence rates of clinical and pathological diagnoses were analyzed in order to characterize the clinicopathological correlations.
Results:
Between August 2016 and December 2023, 185 brain specimens were collected and pathologically evaluated (SNUHBB: 117; PNUHBB: 27; SMCBB: 34; MJHBB: 7). The age at consent was 70.8±12.6 years, and the age at autopsy was 71.7±12.4 years. The four-most-common clinical diagnoses were Alzheimer’s disease (AD) dementia (20.0%), idiopathic Parkinson’s disease (15.1%), unspecified dementia (11.9%), and cognitively unimpaired (CU) (11.4%).Most cases of unspecified dementia had a pathological diagnosis of central nervous system (CNS) vasculopathy (31.8%) or AD (31.8%). Remarkably, only 14.2% of CU cases had normal pathological findings. The three-most-common pathological diagnoses were AD (26.5%), CNS vasculopathy (14.1%), and Lewy body disease (13.5%).
Conclusions
These clinical and neuropathological findings provide a deeper understanding of the mechanisms underlying NDD in South Korea.
3.Clinicopathological Correlations of Neurodegenerative Diseases in the National Brain Biobank of Korea
Young Hee JUNG ; Jun Pyo KIM ; Hee Jin KIM ; Hyemin JANG ; Hyun Jeong HAN ; Young Ho KOH ; Duk L. NA ; Yeon-Lim SUH ; Gi Yeong HUH ; Jae-Kyung WON ; Seong-Ik KIM ; Ji-Young CHOI ; Sang Won SEO ; Sung-Hye PARK ; Eun-Joo KIM
Journal of Clinical Neurology 2025;21(3):190-200
Background:
and Purpose The National Brain Biobank of Korea (NBBK) is a brain bank consortium supported by the Korea Disease Control and Prevention Agency and the Korea National Institute of Health, and was launched in 2015 to support research into neurodegenerative disease dementia (NDD). This study aimed to introduce the NBBK and describes clinicopathological correlations based on analyses of data collected from the NBBK.
Methods:
Four hospital-based brain banks have been established in South Korea: Samsung Medical Center Brain Bank (SMCBB), Seoul National University Hospital Brain Bank (SNUHBB), Pusan National University Hospital Brain Bank (PNUHBB), and Myongji Hospital Brain Bank (MJHBB). Clinical and pathological data were collected from these brain banks using standardized protocols. The prevalence rates of clinical and pathological diagnoses were analyzed in order to characterize the clinicopathological correlations.
Results:
Between August 2016 and December 2023, 185 brain specimens were collected and pathologically evaluated (SNUHBB: 117; PNUHBB: 27; SMCBB: 34; MJHBB: 7). The age at consent was 70.8±12.6 years, and the age at autopsy was 71.7±12.4 years. The four-most-common clinical diagnoses were Alzheimer’s disease (AD) dementia (20.0%), idiopathic Parkinson’s disease (15.1%), unspecified dementia (11.9%), and cognitively unimpaired (CU) (11.4%).Most cases of unspecified dementia had a pathological diagnosis of central nervous system (CNS) vasculopathy (31.8%) or AD (31.8%). Remarkably, only 14.2% of CU cases had normal pathological findings. The three-most-common pathological diagnoses were AD (26.5%), CNS vasculopathy (14.1%), and Lewy body disease (13.5%).
Conclusions
These clinical and neuropathological findings provide a deeper understanding of the mechanisms underlying NDD in South Korea.
4.Clinicopathological Correlations of Neurodegenerative Diseases in the National Brain Biobank of Korea
Young Hee JUNG ; Jun Pyo KIM ; Hee Jin KIM ; Hyemin JANG ; Hyun Jeong HAN ; Young Ho KOH ; Duk L. NA ; Yeon-Lim SUH ; Gi Yeong HUH ; Jae-Kyung WON ; Seong-Ik KIM ; Ji-Young CHOI ; Sang Won SEO ; Sung-Hye PARK ; Eun-Joo KIM
Journal of Clinical Neurology 2025;21(3):190-200
Background:
and Purpose The National Brain Biobank of Korea (NBBK) is a brain bank consortium supported by the Korea Disease Control and Prevention Agency and the Korea National Institute of Health, and was launched in 2015 to support research into neurodegenerative disease dementia (NDD). This study aimed to introduce the NBBK and describes clinicopathological correlations based on analyses of data collected from the NBBK.
Methods:
Four hospital-based brain banks have been established in South Korea: Samsung Medical Center Brain Bank (SMCBB), Seoul National University Hospital Brain Bank (SNUHBB), Pusan National University Hospital Brain Bank (PNUHBB), and Myongji Hospital Brain Bank (MJHBB). Clinical and pathological data were collected from these brain banks using standardized protocols. The prevalence rates of clinical and pathological diagnoses were analyzed in order to characterize the clinicopathological correlations.
Results:
Between August 2016 and December 2023, 185 brain specimens were collected and pathologically evaluated (SNUHBB: 117; PNUHBB: 27; SMCBB: 34; MJHBB: 7). The age at consent was 70.8±12.6 years, and the age at autopsy was 71.7±12.4 years. The four-most-common clinical diagnoses were Alzheimer’s disease (AD) dementia (20.0%), idiopathic Parkinson’s disease (15.1%), unspecified dementia (11.9%), and cognitively unimpaired (CU) (11.4%).Most cases of unspecified dementia had a pathological diagnosis of central nervous system (CNS) vasculopathy (31.8%) or AD (31.8%). Remarkably, only 14.2% of CU cases had normal pathological findings. The three-most-common pathological diagnoses were AD (26.5%), CNS vasculopathy (14.1%), and Lewy body disease (13.5%).
Conclusions
These clinical and neuropathological findings provide a deeper understanding of the mechanisms underlying NDD in South Korea.
5.Effect of scan path on accuracy of complete arch intraoral scan
Eui-Jun CHOI ; Kyung-Ho KO ; Yoon-Hyuk HUH ; Chan-Jin PARK ; Lee-Ra CHO
The Journal of Advanced Prosthodontics 2024;16(6):319-327
PURPOSE:
This study aimed to compare the accuracy of an alternative scan path with that of traditional scan paths to obtain a more accurate method for complete arch scans.
MATERIALS AND METHODS:
A mandibular stone cast, including tooth preparations for the inlay, crown, and fixed prosthesis, was scanned 10 times using four different scan paths (A, B, C, and D). The scans were converted into stereolithography files, resized, and superimposed onto a control file obtained from a desktop scanner. The scan time, total surface deviation, and local deviation of the mandibular teeth were measured. One-way analysis of variance (ANOVA) and Welch ANOVA were used for statistical analyses (α = .05). The relative standard deviation and standard error of the mean were calculated to evaluate accuracy.
RESULTS:
The total surface deviation differed significantly according to the scanning path despite a similar scan time. Path D had the highest accuracy and the most uniform color maps, showing minimal deformation of the digital model. Meanwhile, no significant differences were found in the local deviations in the individual tooth assessments, likely owing to issues with the superimposition method.
CONCLUSION
Among all scan paths, the scan path with the shortest distance from the starting point to the end point showed the smallest total surface deviation and the highest accuracy. No differences were observed in the deviations of specific teeth based on the scan path.
6.Effect of scan path on accuracy of complete arch intraoral scan
Eui-Jun CHOI ; Kyung-Ho KO ; Yoon-Hyuk HUH ; Chan-Jin PARK ; Lee-Ra CHO
The Journal of Advanced Prosthodontics 2024;16(6):319-327
PURPOSE:
This study aimed to compare the accuracy of an alternative scan path with that of traditional scan paths to obtain a more accurate method for complete arch scans.
MATERIALS AND METHODS:
A mandibular stone cast, including tooth preparations for the inlay, crown, and fixed prosthesis, was scanned 10 times using four different scan paths (A, B, C, and D). The scans were converted into stereolithography files, resized, and superimposed onto a control file obtained from a desktop scanner. The scan time, total surface deviation, and local deviation of the mandibular teeth were measured. One-way analysis of variance (ANOVA) and Welch ANOVA were used for statistical analyses (α = .05). The relative standard deviation and standard error of the mean were calculated to evaluate accuracy.
RESULTS:
The total surface deviation differed significantly according to the scanning path despite a similar scan time. Path D had the highest accuracy and the most uniform color maps, showing minimal deformation of the digital model. Meanwhile, no significant differences were found in the local deviations in the individual tooth assessments, likely owing to issues with the superimposition method.
CONCLUSION
Among all scan paths, the scan path with the shortest distance from the starting point to the end point showed the smallest total surface deviation and the highest accuracy. No differences were observed in the deviations of specific teeth based on the scan path.
7.Effect of scan path on accuracy of complete arch intraoral scan
Eui-Jun CHOI ; Kyung-Ho KO ; Yoon-Hyuk HUH ; Chan-Jin PARK ; Lee-Ra CHO
The Journal of Advanced Prosthodontics 2024;16(6):319-327
PURPOSE:
This study aimed to compare the accuracy of an alternative scan path with that of traditional scan paths to obtain a more accurate method for complete arch scans.
MATERIALS AND METHODS:
A mandibular stone cast, including tooth preparations for the inlay, crown, and fixed prosthesis, was scanned 10 times using four different scan paths (A, B, C, and D). The scans were converted into stereolithography files, resized, and superimposed onto a control file obtained from a desktop scanner. The scan time, total surface deviation, and local deviation of the mandibular teeth were measured. One-way analysis of variance (ANOVA) and Welch ANOVA were used for statistical analyses (α = .05). The relative standard deviation and standard error of the mean were calculated to evaluate accuracy.
RESULTS:
The total surface deviation differed significantly according to the scanning path despite a similar scan time. Path D had the highest accuracy and the most uniform color maps, showing minimal deformation of the digital model. Meanwhile, no significant differences were found in the local deviations in the individual tooth assessments, likely owing to issues with the superimposition method.
CONCLUSION
Among all scan paths, the scan path with the shortest distance from the starting point to the end point showed the smallest total surface deviation and the highest accuracy. No differences were observed in the deviations of specific teeth based on the scan path.
8.Effect of scan path on accuracy of complete arch intraoral scan
Eui-Jun CHOI ; Kyung-Ho KO ; Yoon-Hyuk HUH ; Chan-Jin PARK ; Lee-Ra CHO
The Journal of Advanced Prosthodontics 2024;16(6):319-327
PURPOSE:
This study aimed to compare the accuracy of an alternative scan path with that of traditional scan paths to obtain a more accurate method for complete arch scans.
MATERIALS AND METHODS:
A mandibular stone cast, including tooth preparations for the inlay, crown, and fixed prosthesis, was scanned 10 times using four different scan paths (A, B, C, and D). The scans were converted into stereolithography files, resized, and superimposed onto a control file obtained from a desktop scanner. The scan time, total surface deviation, and local deviation of the mandibular teeth were measured. One-way analysis of variance (ANOVA) and Welch ANOVA were used for statistical analyses (α = .05). The relative standard deviation and standard error of the mean were calculated to evaluate accuracy.
RESULTS:
The total surface deviation differed significantly according to the scanning path despite a similar scan time. Path D had the highest accuracy and the most uniform color maps, showing minimal deformation of the digital model. Meanwhile, no significant differences were found in the local deviations in the individual tooth assessments, likely owing to issues with the superimposition method.
CONCLUSION
Among all scan paths, the scan path with the shortest distance from the starting point to the end point showed the smallest total surface deviation and the highest accuracy. No differences were observed in the deviations of specific teeth based on the scan path.
9.Effect of scan path on accuracy of complete arch intraoral scan
Eui-Jun CHOI ; Kyung-Ho KO ; Yoon-Hyuk HUH ; Chan-Jin PARK ; Lee-Ra CHO
The Journal of Advanced Prosthodontics 2024;16(6):319-327
PURPOSE:
This study aimed to compare the accuracy of an alternative scan path with that of traditional scan paths to obtain a more accurate method for complete arch scans.
MATERIALS AND METHODS:
A mandibular stone cast, including tooth preparations for the inlay, crown, and fixed prosthesis, was scanned 10 times using four different scan paths (A, B, C, and D). The scans were converted into stereolithography files, resized, and superimposed onto a control file obtained from a desktop scanner. The scan time, total surface deviation, and local deviation of the mandibular teeth were measured. One-way analysis of variance (ANOVA) and Welch ANOVA were used for statistical analyses (α = .05). The relative standard deviation and standard error of the mean were calculated to evaluate accuracy.
RESULTS:
The total surface deviation differed significantly according to the scanning path despite a similar scan time. Path D had the highest accuracy and the most uniform color maps, showing minimal deformation of the digital model. Meanwhile, no significant differences were found in the local deviations in the individual tooth assessments, likely owing to issues with the superimposition method.
CONCLUSION
Among all scan paths, the scan path with the shortest distance from the starting point to the end point showed the smallest total surface deviation and the highest accuracy. No differences were observed in the deviations of specific teeth based on the scan path.
10.Therapeutic Outcomes and Electrophysiological Biomarkers in Anti-Myelin-Associated Glycoprotein Neuropathy:A Multicenter Cohort Study in South Korea
Young Gi MIN ; Hee-Jo HAN ; Ha Young SHIN ; Jong-Gyu BAEK ; Jun-Soon KIM ; Kyung-Seok PARK ; Seol-Hee BAEK ; Ilhan YOO ; So-Young HUH ; Young Nam KWON ; Seok-Jin CHOI ; Sung-Min KIM ; Yoon-Ho HONG ; Jung-Joon SUNG
Journal of Clinical Neurology 2024;20(1):50-58
Background:
and Purpose Unlike other immune-mediated neuropathies, anti-myelin-associated glycoprotein (MAG) neuropathy is often refractory to immunotherapy. It is necessary to compare the relative efficacies of various immunotherapies and develop objective biomarkers in order to optimize its clinical management.
Methods:
This study recruited 91 patients with high anti-MAG antibody titers from 7 tertiary hospitals in South Korea. We analyzed the baseline characteristics, therapeutic outcomes, and nerve conduction study (NCS) findings of 68 patients and excluded 23 false positive cases.
Results:
The rate of positive responses to treatment was highest using zanubrutinib (50%) and rituximab (36.4%), followed by corticosteroids (16.7%), immunosuppressants (9.5%), intravenous immunoglobulin (5%), and plasma exchange (0%). Disability and weakness were significantly associated with multiple NCS parameters at the time of diagnosis, especially distal compound muscle action potential (CMAP) amplitudes. Moreover, the longitudinal trajectory of the average CMAP amplitudes paralleled the clinical courses, with a 16.2 percentile decrease as an optimal cutoff for predicting a clinical exacerbation (area under the receiver operating characteristic curve=0.792).
Conclusions
Our study supports the use of NCS as an objective marker for estimating disease burden and tracking clinical changes in patients with anti-MAG neuropathy. We have described the beneficial effects of rituximab and a new drug, zanubrutinib, compared with conventional immunotherapies.

Result Analysis
Print
Save
E-mail