1.Delayed Retroperitoneal Hematoma Following Intradiscal Electrothermal Therapy: A Case Report of a Rare Complication
Jun-Yong CHA ; Yun-Young PARK ; Jin-Uk KIM ; Jun-Ho LEE ; Seong-Hwan MUN ; Gun AHN ; Il-Tae JANG
The Nerve 2026;12(1):36-40
Intradiscal electrothermal therapy (IDET) is a minimally invasive procedure used to treat discogenic back pain and offers an alternative to surgical intervention in selected patients. Although it is generally considered safe, rare but significant complications can occur and may be difficult to diagnose because their symptoms overlap with those of other spinal conditions. We describe the case of a 69-year-old woman who presented with severe lower back and left buttock pain that was unresponsive to conservative treatment. Magnetic resonance imaging revealed disc bulging with a high-intensity zone at the L4–5 and L5–S1 levels. IDET was performed at the L4–5 level, resulting in initial pain relief. However, the patient returned 7 days later with recurrent pain. Despite undergoing percutaneous epidural neuroplasty at the left L5–S1 level, a medial branch block, and a piriformis muscle block, her symptoms persisted. Further evaluation with spinal computed tomography revealed a retroperitoneal hematoma near the left psoas muscle. Referred pain from the hematoma mimicked discogenic pain, resulting in delayed diagnosis and unnecessary interventions. The patient remained hemodynamically stable and gradually improved with conservative management alone. This case highlights retroperitoneal hematoma as a rare complication of IDET and emphasizes the importance of accurate and timely diagnosis in patients with persistent or worsening symptoms after spinal procedures. Clinicians should consider non-discogenic sources of pain when treatment outcomes deviate from expected patterns.
2.Part 1. Current Status of Hearing Loss Patients in Korea Using National Data: National Health Insurance Service- Database, 2010 to 2020
Junhun LEE ; Chul Young YOON ; Jiwon KIM ; In-Ki JIN ; Michelle J. SUH ; Wan-Ho CHO ; Hyo-Jeong LEE ; Seong Jun CHOI ; Dongchul CHA ; Kyung Ho PARK ; Soo Hee OH ; Young Joon SEO ; Tae Hoon KONG
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(1):7-18
Background and Objectives:
Hearing loss significantly affects communication, psychosocial well-being, and quality of life. This study analyzes the National Health Insurance Service database to assess the trends and characteristics of hearing loss in South Korea from 2010 to 2020.Subjects and Method The database encompasses 97% of the Korean population, providing comprehensive data on medical history, prescriptions, and health examinations. The analysis used the World Health Organization’s ICD-10 definitions to categorize hearing loss types and examine their prevalence and incidence across various demographics over 11 years.
Results:
There was an overall annual increase of 4.62% in diagnosed cases of hearing loss, with the most significant rise among the elderly. The rate of increase accelerated from 3.32% between 2010 and 2014 to 6.49% between 2014 and 2020, corresponding with the improved hearing aid access facilitated by policy changes. Women showed a slightly higher increase than men. The data also indicated a consistent rise in abnormal hearing test results during health examinations, especially in older adults.
Conclusion
The study highlights an increasing trend in hearing loss diagnoses, driven by an aging population and enhanced detection facilitated by policy changes. These findings emphasize the need for continuous monitoring and targeted health policies to manage hearing loss effectively, offering valuable insights for global health management and policy development.
3.Part 2. Current Status of Hearing Disability and Hearing Rehabilitation Devices in Korea Using National Data: NHIS-Database, 2010 to 2020
Junhun LEE ; Chul Young YOON ; Jiwon KIM ; In-Ki JIN ; Michelle J. SUH ; Wan-Ho CHO ; Hyo-Jeong LEE ; Seong Jun CHOI ; Dongchul CHA ; Kyung Ho PARK ; Soo Hee OH ; Young Joon SEO ; Tae Hoon KONG
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(3):94-104
Background and Objectives:
This study aims to analyze trends in hearing disability and the use of hearing rehabilitation devices (hearing aids and cochlear implants) in South Korea over the past 11 years (2010-2020) using data from the National Health Insurance Service (NHIS).Subjects and Method Data were extracted from the NHIS database, covering approximately 97% of the South Korean population. Patients diagnosed with hearing loss were classified using ICD-10 codes. The data were analyzed to determine trends in hearing disability, hearing aid prescriptions, and cochlear implant usage by age, gender, and types and causes of hearing loss.
Results:
The number of hearing disability patients increased from 170900 in 2010 to 362738 in 2020, with an annual growth rate of 7.95%. The highest increase was observed in the ≥60 age group, with an annual growth rate of 11.04%. Hearing aid prescriptions rose from 4966 in 2010 to 11974 in 2020, showing a 10.45% annual increase. Females showed a higher growth rate in both hearing disability and hearing aid prescriptions compared to males. Cochlear implant prescriptions also increased, particularly among older adults.
Conclusion
The study highlights a significant rise in hearing disability and the use of hearing aids and cochlear implants in South Korea, especially among the elderly. The findings underscore the importance of early diagnosis and intervention for hearing loss and the need for policy improvements to enhance accessibility and affordability of hearing rehabilitation services. Additional strategies are needed to ensure appropriate hearing rehabilitation for those not yet receiving adequate care.
4.Prevalence of asymptomatic malaria in high- and low-transmission areas of Tanzania: The role of asymptomatic carriers in malaria persistence and the need for targeted surveillance and control efforts
Ernest MAZIGO ; Hojong JUN ; Wang-Jong LEE ; Johnsy Mary LOUIS ; Fadhila FITRIANA ; Jadidan Hada SYAHADA ; Fauzi MUH ; Feng LU ; Md Atique AHMED ; Seok Ho CHA ; Wanjoo CHUN ; Won Sun PARK ; Se Jin LEE ; Sunghun NA ; Joon-Hee HAN ; Nyalali KIJA ; Smart GEODFREY ; Eun-Teak HAN ; Jim TODD ; Alphaxard MANJURANO ; Winifrida KIDIMA ; Jin-Hee HAN
Parasites, Hosts and Diseases 2025;63(1):57-65
As many countries implement different programs aimed at eliminating malaria, attention should be given to asymptomatic carriers that may interrupt the progress. This was a community-based cross-sectional study conducted in Tanzania from December 2022 to July 2023 within 4 villages from each of the 3 regions, Geita and Kigoma, which are high malaria transmission, and Arusha, which is low transmission. Malaria was diagnosed in asymptomatic individuals aged 1 year and older using the malaria rapid diagnostic test and light microscope. A total of 2,365 of 3,489 (67.9%) participants were enrolled from high-transmission villages. The overall prevalence was 25.5% and 15.8% by malaria rapid diagnostic test and light microscope, respectively. Using the respective tools, the prevalence was significantly higher at 35.6% (confidence interval (CI)=23.6–49.9) and 23.1% (CI=16.2–35.1) in the high-transmission regions (Geita and Kigoma) compared with 2.9% (CI=1.1–3.5) and 1.1% (CI=0.7–1.8) in the low-transmission region (Arusha). Children younger than 15 years and males accounted for the greatest proportion of infections. In the study area, the prevalence of asymptomatic cases was higher than that of reported symptomatic cases in health facilities. We hypothesize that these parasite reservoirs may contribute to the persistence of malaria in the country. Therefore, to achieve comprehensive malaria control in the country, the surveillance and screening of asymptomatic malaria cases are vital.
5.Long-Term Incidence of Gastrointestinal Bleeding Following Ischemic Stroke
Jun Yup KIM ; Beom Joon KIM ; Jihoon KANG ; Do Yeon KIM ; Moon-Ku HAN ; Seong-Eun KIM ; Heeyoung LEE ; Jong-Moo PARK ; Kyusik KANG ; Soo Joo LEE ; Jae Guk KIM ; Jae-Kwan CHA ; Dae-Hyun KIM ; Tai Hwan PARK ; Kyungbok LEE ; Hong-Kyun PARK ; Yong-Jin CHO ; Keun-Sik HONG ; Kang-Ho CHOI ; Joon-Tae KIM ; Dong-Eog KIM ; Jay Chol CHOI ; Mi-Sun OH ; Kyung-Ho YU ; Byung-Chul LEE ; Kwang-Yeol PARK ; Ji Sung LEE ; Sujung JANG ; Jae Eun CHAE ; Juneyoung LEE ; Min-Surk KYE ; Philip B. GORELICK ; Hee-Joon BAE ;
Journal of Stroke 2025;27(1):102-112
Background:
and Purpose Previous research on patients with acute ischemic stroke (AIS) has shown a 0.5% incidence of major gastrointestinal bleeding (GIB) requiring blood transfusion during hospitalization. The existing literature has insufficiently explored the long-term incidence in this population despite the decremental impact of GIB on stroke outcomes.
Methods:
We analyzed the data from a cohort of patients with AIS admitted to 14 hospitals as part of a nationwide multicenter prospective stroke registry between 2011 and 2013. These patients were followed up for up to 6 years. The occurrence of major GIB events, defined as GIB necessitating at least two units of blood transfusion, was tracked using the National Health Insurance Service claims data.
Results:
Among 10,818 patients with AIS (male, 59%; mean age, 68±13 years), 947 (8.8%) experienced 1,224 episodes of major GIB over a median follow-up duration of 3.1 years. Remarkably, 20% of 947 patients experienced multiple episodes of major GIB. The incidence peaked in the first month after AIS, reaching 19.2 per 100 person-years, and gradually decreased to approximately one-sixth of this rate by the 2nd year with subsequent stabilization. Multivariable analysis identified the following predictors of major GIB: anemia, estimated glomerular filtration rate <60 mL/min/1.73 m2 , and a 3-month modified Rankin Scale score of ≥4.
Conclusion
Patients with AIS are susceptible to major GIB, particularly in the first month after the onset of AIS, with the risk decreasing thereafter. Implementing preventive strategies may be important, especially for patients with anemia and impaired renal function at stroke onset and those with a disabling stroke.
6.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
7.Comparing Stability, Gait, and Functional Score after 40-mm Dual-Mobility Hip Arthroplasty to 36-mm Head Hip Arthroplasty in Elderly Hip Fracture Patients
Yonghan CHA ; Sang-Yeob LEE ; Ji-Ho BAE ; Yang Jae KANG ; Ji-Hoon BAEK ; Joon Soon KANG ; Chan Ho PARK ; Shinjune KIM ; Jun-Il YOO
Clinics in Orthopedic Surgery 2025;17(1):62-70
Background:
This study aimed to compare the intraoperative stability and early clinical outcomes of 40-mm diameter dual mobility (DM)-total hip arthroplasty (THA) with 36-mm ceramic head (large head) THA in active elderly patients with hip fractures.
Methods:
A prospective randomized controlled trial was conducted from May 2022 to December 2022. Inclusion criteria were as follows: age ≥ 60 years, displaced femoral neck fracture, Koval grade 1 or 2, planned 54-mm acetabular component, and over 1-year follow-up. Intraoperative stability tests were performed on all patients (internal rotation at 45°, 60°, and 90° of hip fracture). Functional outcomes (Harris Hip Score and University of California, Los Angeles [UCLA] Score) were evaluated at 6 weeks and 3 months postoperatively. Gait analysis using artificial intelligence (AI) techniques was conducted at 3 months postoperatively.
Results:
The study included 36 DM-THA patients (mean age, 69.6 ± 2.2 years; 44% women) and 37 large head THA patients (mean age, 69.6 ± 1.2 years; 64% women). No statistically significant differences were observed in functional outcomes and hip range of motion between the 2 groups. However, there was a significant difference in the gait speed and stance-swing phase of the large head THA group and the DM-THA group: the DM-THA group demonstrated superior gait speed (2.85 ± 0.83 kph vs. 2.04 ± 1.04 kph, p = 0.003) and higher stance phase ratios (operated side: 63.57% ± 3.82% vs. 48.19% ± 5.50%, p < 0.001; opposite side: 62.77% ± 2.27% vs. 49.93% ± 6.94%, p < 0.001). In the stability test at 90° of hip flexion, the DM-THA group had a measurement of 48.40° ± 5.17°, while the large head THA group had a measurement of 30.94° ± 2.98° (p = 0.012). Despite the lack of statistical significance, the intraoperative stability test showed the dislocation angle was notably different between the groups in the hip flexion position of 60° (51.60° ± 6.09° in the DM-THA group and 40.00° ± 2.80° in the large head THA group, p = 0.072).
Conclusions
Superior results were observed in the intraoperative stability test and early recovery of gait after DM-THA compared to large head THA. We believe that DM-THA can be a useful surgical option for THA in elderly patients with hip fractures.
8.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
9.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
10.Comparing Stability, Gait, and Functional Score after 40-mm Dual-Mobility Hip Arthroplasty to 36-mm Head Hip Arthroplasty in Elderly Hip Fracture Patients
Yonghan CHA ; Sang-Yeob LEE ; Ji-Ho BAE ; Yang Jae KANG ; Ji-Hoon BAEK ; Joon Soon KANG ; Chan Ho PARK ; Shinjune KIM ; Jun-Il YOO
Clinics in Orthopedic Surgery 2025;17(1):62-70
Background:
This study aimed to compare the intraoperative stability and early clinical outcomes of 40-mm diameter dual mobility (DM)-total hip arthroplasty (THA) with 36-mm ceramic head (large head) THA in active elderly patients with hip fractures.
Methods:
A prospective randomized controlled trial was conducted from May 2022 to December 2022. Inclusion criteria were as follows: age ≥ 60 years, displaced femoral neck fracture, Koval grade 1 or 2, planned 54-mm acetabular component, and over 1-year follow-up. Intraoperative stability tests were performed on all patients (internal rotation at 45°, 60°, and 90° of hip fracture). Functional outcomes (Harris Hip Score and University of California, Los Angeles [UCLA] Score) were evaluated at 6 weeks and 3 months postoperatively. Gait analysis using artificial intelligence (AI) techniques was conducted at 3 months postoperatively.
Results:
The study included 36 DM-THA patients (mean age, 69.6 ± 2.2 years; 44% women) and 37 large head THA patients (mean age, 69.6 ± 1.2 years; 64% women). No statistically significant differences were observed in functional outcomes and hip range of motion between the 2 groups. However, there was a significant difference in the gait speed and stance-swing phase of the large head THA group and the DM-THA group: the DM-THA group demonstrated superior gait speed (2.85 ± 0.83 kph vs. 2.04 ± 1.04 kph, p = 0.003) and higher stance phase ratios (operated side: 63.57% ± 3.82% vs. 48.19% ± 5.50%, p < 0.001; opposite side: 62.77% ± 2.27% vs. 49.93% ± 6.94%, p < 0.001). In the stability test at 90° of hip flexion, the DM-THA group had a measurement of 48.40° ± 5.17°, while the large head THA group had a measurement of 30.94° ± 2.98° (p = 0.012). Despite the lack of statistical significance, the intraoperative stability test showed the dislocation angle was notably different between the groups in the hip flexion position of 60° (51.60° ± 6.09° in the DM-THA group and 40.00° ± 2.80° in the large head THA group, p = 0.072).
Conclusions
Superior results were observed in the intraoperative stability test and early recovery of gait after DM-THA compared to large head THA. We believe that DM-THA can be a useful surgical option for THA in elderly patients with hip fractures.

Result Analysis
Print
Save
E-mail