1.Shrapnel in carotid sheath: A rare penetrating neck injury.
Muhammad REHAN ; Savera ANWAR ; Hadia WALI ; Aysha NOOR ; Omer EHSAN ; Shayan Shahid ANSARI
Chinese Journal of Traumatology 2025;28(3):231-234
Injuries deeper than the platysma are considered as penetrating neck injuries, constituting approximately 5% - 10% of all trauma. Many vital organs are at risk from a penetrating neck injury. These injuries in zone 1 have the highest mortality, because the injuries are close to the vital organs and difficult to access surgically. A 41-year-old male, a car mechanic by profession, presented to the emergency department with a penetrating neck injury on the right side. CT scan demonstrated a metallic foreign body in zone 1 between the right internal jugular vein and the common carotid artery. The patient was asymptomatic, and the foreign body was removed surgically. This case shows a rare presentation of a penetrating neck injury with a foreign body located in zone 1, where no vital internal structure was injured. As of now, no previous case report has been identified on such presentation. Thus, it will provide a valuable addition to the pre-existing literature.
Humans
;
Male
;
Adult
;
Neck Injuries/diagnostic imaging*
;
Wounds, Penetrating/diagnostic imaging*
;
Foreign Bodies/diagnostic imaging*
;
Jugular Veins
;
Tomography, X-Ray Computed
;
Carotid Artery Injuries/surgery*
;
Carotid Artery, Common
2.Radiologic placement of totally implantable venous access devices: Outcomes and complications from a large oncology cohort.
Sonam TASHI ; Alfred Bingchao TAN ; Jasmine Ming Er CHUA ; Gek Hsiang LIM ; Nanda VENKATANARASIMHA ; Sivanathan CHANDRAMOHAN
Annals of the Academy of Medicine, Singapore 2024;54(1):27-35
INTRODUCTION:
Totally implantable venous access devices (TIVADs) or ports are increasingly used in oncology settings to provide long-term, easy venous access. This study reports our experience and results with 1180 cases in Singapore.
METHOD:
Data from January 2019 to January 2022, obtained from a hospital-approved secure database application called the Research Electronic Data Capture registry, were reviewed and analysed retrospectively.
RESULTS:
A total of 1180 patients underwent TIVAD implantation with a 100% technical success rate. The mean age of the cohort was 61.9 years. The mean dwell duration was 342 days (standard deviation [SD] 223; range 3-1911). By 1 February 2022, 83% of patients were still using the TIVAD, 13.6 % underwent removal after completion of treatment, 2.1% were removed due to infection, 0.6% due to malfunction, 0.6% due to port extrusion and 0.1% at patient's request. The right internal jugular vein (IJV) was the most commonly accessed site (83.6%), followed by the left IJV (15.6%). The early post-procedure complications were pain (24.7%), bruising (9.2%), swelling (3.6%), bleeding (0.5%), fever (0.4%), itchiness (0.2%) and allergic dermatitis (0.1%). The delayed post-procedure complications were TIVAD site cellulitis (3.80%); discharge (1.10%); skin erosion with device extrusion (0.60%); malpositioned catheter (0.33%), which was successfully repositioned, catheter-related bloodstream infections (0.25%); migration of TIVAD leading to catheter dislodgement (0.25%); venous thrombosis (0.25%); fibrin sheath formation requiring stripping (0.10%) and TIVAD chamber inversion (0.10%).
CONCLUSION
TIVAD implantation via the jugular vein under radiological guidance provides a safe, reliable and convenient means of long-term venous access in oncology patients. By sharing our experience and acceptable outcomes from a large oncology cohort, we aim to increase the awareness and adoption of TIVAD usage in oncology patients, especially in Asia.
Humans
;
Middle Aged
;
Male
;
Female
;
Retrospective Studies
;
Singapore/epidemiology*
;
Aged
;
Catheterization, Central Venous/instrumentation*
;
Neoplasms/drug therapy*
;
Catheters, Indwelling/adverse effects*
;
Adult
;
Jugular Veins/diagnostic imaging*
;
Aged, 80 and over
;
Catheter-Related Infections/epidemiology*
;
Central Venous Catheters/adverse effects*
3.Clinical experience of REcanalisation and balloon-oriented puncture for Re-insertion of long- term dialysis catheter in nonpatent central veins.
Qiang LI ; Liang You ZHANG ; Gang Yi CHEN ; Shui Fu TANG
Chinese Journal of Hepatology 2023;39(1):39-41
It is difficult to insert long-term dialysis catheters after severe stenosis or occlusion of the internal jugular vein and innominate vein. We used REcanalisation and balloon-oriented puncture for Re-insertion of dialysis catheter in nonpatent central veins (REBORN) in seven patients with severe central venous lesions, and all patients were inserted with long-term dialysis catheters successfully. None had severe complications such as pneumothorax, hemothorax, or pulmonary embolism during operation. All catheters functioned well after postoperative follow-up of 2 months. REBORN provides a novel approach to establish difficult dialysis pathways.
Humans
;
Catheterization, Central Venous/adverse effects*
;
Catheters, Indwelling
;
Renal Dialysis
;
Jugular Veins
;
Punctures
4.Surgical complications of totally implantable venous access port in children with malignant tumors.
Hui LI ; Yang Xu GAO ; Shu Lei WANG ; Hong Xin YAO
Journal of Peking University(Health Sciences) 2022;54(6):1167-1171
OBJECTIVE:
To summarize the surgical experience of totally implantable venous access port in children with malignant tumors, and to explore the coping methods of surgical complications.
METHODS:
The clinical data of 165 children with malignant tumors implanted in totally implantable venous access port in Department of Pediatric Surgery, Peking University First Hospital from January 2017 to December 2019 were retrospectively analyzed. The operation process, complications and treatment of complications were observed and counted.
RESULTS:
The children in this group were divided into external ju-gular vein incision group (n=27) and internal jugular vein puncture group (n=138) according to different surgical methods, and the latter was divided into ultrasound guided puncture group (n=95) and blind puncture group (n=43). No puncture complications occurred in the external jugular vein incision group, and the average time for successful catheterization and the number of times for catheter to enter the superior vena cava were more than those in the internal jugular vein puncture group [(9.26±1.85) min vs. (5.76±1.56) min, (1.93±0.87) times vs. 1 time], with statistical significance. The average time of successful catheterization, the success rate of one puncture, the average number of punctures and the incidence of puncture complications in the ultrasound guided right internal jugular vein puncture group were better than those in the blind puncture group [(5.36±1.12) min vs. (6.67±1.99) min, 93.68% (89/95) vs. 74.42% (32/43), (1.06±0.24) times vs. (1.29±0.55) times, 2.11% (2/95) vs. 11.63% (5/43)], with statistically significant differences. The total incidence of complications in this study was 12.12% (20/165). Pneumothorax occurred in 1 case, artery puncture by mistake in 1 case, local hematoma in 5 cases, venous access port related infection in 4 cases (venous access port local infection in 2 cases, catheter related blood flow infection in 2 cases), subcutaneous tissue thinning on the surface of port seat in 2 cases, port seat overturning in 1 case, poor transfusion in 4 cases (catheter discount in 1 case, catheter blockage in 3 cases), and foreign bodies gathered around the subcutaneous pipeline in 2 cases. There were no complications, such as catheter rupture, detachment and catheter clamping syndrome.
CONCLUSION
Totally implantable venous access port can provide safe and effective infusion channels for children with malignant tumors. Right external jugular vein incision and ultrasound-guided right internal jugular vein puncture are reliable surgical methods for children's totally implantable venous access port implantation. Surgeons should fully understand the complications of the venous access port, take measures to reduce the occurrence of complications, and properly handle the complications that have occurred.
Humans
;
Child
;
Catheterization, Central Venous/methods*
;
Retrospective Studies
;
Vena Cava, Superior
;
Jugular Veins/surgery*
;
Neoplasms/surgery*
5.Application of ultrasound-guided central venous catheterization at various sites in infants with shock.
Zi-Feng TAN ; Ke-Ze MA ; Zhi-Jun LAI
Chinese Journal of Contemporary Pediatrics 2022;24(5):591-595
OBJECTIVES:
To study the clinical characteristics of ultrasound-guided central venous catheterization at various sites in infants with shock, and to explore how to quickly select the site for central venous puncture in infants with shock.
METHODS:
The medical data of 112 infants who were diagnosed with shock and underwent central venous catheterization in the Pediatric Intensive Care Unit, Dongguan Children's Hospital Affiliated to Guangdong Medical University, from January 2016 to December 2020 were reviewed retrospectively. The patients were divided into an ultrasound group (n=70) and a body surface location group (n=42) according to whether the catheterization was carried out under ultrasound guidance. The application of ultrasound-guided catheterization at various sites in infants was summarized and analyzed, and the success rate of one-time puncture, overall success rate, catheterization time, and complications were compared between these sites.
RESULTS:
Compared with the body surface location group, the ultrasound group had a significantly higher success rate of one-time puncture, a significantly shorter catheterization time, and a significantly reduced incidence rate of complications in internal jugular vein and femoral vein catheterizations (P<0.05). In the ultrasound group, the proportion of internal jugular vein catheterization was the highest (51%, 36/70), followed by femoral vein catheterization (33%, 23/70), and subclavian vein catheterization (16%, 11/70). For the comparison between different puncture sites under ultrasound guidance, internal jugular vein catheterization showed the shortest time of a successful catheterization [5.5 (5.0, 6.5) minutes] (P<0.05). There was no significant difference in the incidence rate of complications among the different puncture sites groups (P>0.05).
CONCLUSIONS
In infants with shock, ultrasound-guided internal jugular vein catheterization can be used as the preferred catheterization method for clinicians.
Catheterization, Central Venous/adverse effects*
;
Child
;
Humans
;
Infant
;
Jugular Veins/diagnostic imaging*
;
Retrospective Studies
;
Ultrasonography
;
Ultrasonography, Interventional
6.Analysis of 53 cases of transjugular liver biopsy.
Lei WANG ; Zhen Dong YUE ; Hong Wei ZHAO ; Zhen Hua FAN ; Yi Fan WU ; Yu ZHANG ; Rui Zhao QI ; Ke ZHANG ; Li JIANG ; Hui Guo DING ; Yue Ning ZHANG ; Fu Quan LIU
Chinese Journal of Hepatology 2022;30(2):220-223
Objective: To investigate the practicability and safety of transjugular liver biopsy (TJLB). Methods: Data of 53 cases with transjugular liver biopsy from June 2015 to June 2020 were collected. LABS-100 was used in all patients who underwent transjugular liver biopsy. Among them, 45 cases and eight were biopsied via hepatic vein and intrahepatic segment of the inferior vena cava. The surgical indications, related complications, and postoperative pathological diagnosis were analyzed and summarized. Results: TJLB was successful in all patients, with an average of 2.8 punctures per case. Satisfactory liver tissue and histopathological diagnosis was obtained in all patients. Two cases developed a cervical hematoma that was improved spontaneously, and one patient developed an intrahepatic hematoma that was improved after conservative treatment. Conclusion: TJLB is a practical and safe method for patients with contraindications to percutaneous liver biopsy.
Biopsy/methods*
;
Biopsy, Needle/methods*
;
Humans
;
Jugular Veins
;
Liver Diseases/pathology*
7.Condylar jugular diverticulum: A report of 3 cases
Rohan JAGTAP ; Taggreed WAZZAN ; Matthew HANSEN ; Deeba KASHTWARI
Imaging Science in Dentistry 2019;49(3):251-256
Jugular bulb diverticulum is an irregular extension of the jugular bulb into the temporal bone that may be symptomatic or asymptomatic. The jugular bulb has rarely been reported to extend into the occipital condyle; such extension is termed a condylar jugular diverticulum and is characterized as a defect in the occipital condyle contiguous with the jugular bulb. This report details 3 cases of condylar jugular diverticulum. Extension of the jugular bulb into the ipsilateral occipital condyle was noted as an incidental finding on cone-beam computed tomographic (CBCT) images of 3 patients. All 3 patients were asymptomatic, and this finding was unrelated to the initial area of interest. CBCT use is becoming ubiquitous in dentistry, as it allows 3-dimensional evaluation, unlike conventional radiography. Proper interpretation of the entire CBCT is essential, and recognition of the indicators of condylar jugular diverticulum may prevent misdiagnosis of this rare entity.
Cone-Beam Computed Tomography
;
Dentistry
;
Diagnostic Errors
;
Diverticulum
;
Growth and Development
;
Humans
;
Incidental Findings
;
Jugular Veins
;
Radiography
;
Temporal Bone
8.Accidental Sharp Force Fatality Caused by a Broken Glass Cup
Korean Journal of Legal Medicine 2019;43(1):28-32
Most sharp force fatalities are attributed to homicide or suicide, with only a few accidental cases reported to date. Broken glass accounts for most of these accidental fatalities. We herein report an unusual accidental death caused by a broken glass cup. A 21-year-old woman was found dead on the floor of her studio apartment. The studio was a duplex consisting of one room and a bathroom, with a stepped drawer leading to the second floor. She was lying face down with her legs spread apart in a large pool of blood, surrounded by many pieces of broken glass. There was an oblique cut measuring 9 cm in length in the right sternocleidomastoid region just above the right clavicle. The surface of the cut wound showed irregular edges and the internal jugular vein was severed in the depth of the wound. She appeared to have fallen down the steps onto the ground floor and been fatally injured in the neck by a piece of broken glass.
Clavicle
;
Deception
;
Female
;
Glass
;
Homicide
;
Humans
;
Jugular Veins
;
Leg
;
Neck
;
Neck Injuries
;
Suicide
;
Wounds and Injuries
;
Young Adult
9.New Viewpoint of Surface Anatomy Using the Curved Sectional Planes of a Male Cadaver.
Koojoo KWON ; Byeong Seok SHIN ; Min Suk CHUNG ; Beom Sun CHUNG
Journal of Korean Medical Science 2019;34(3):e15-
BACKGROUND: The curved sectional planes of the human body can provide a new approach of surface anatomy that the classical horizontal, coronal, and sagittal planes cannot do. The purpose of this study was to verify whether the curved sectional planes contribute to the morphological comprehension of anatomical structures. METHODS: By stacking the sectioned images of a male cadaver, a volume model of the right half body was produced (voxel size 1 mm). The sectioned images with the segmentation data were also used to build another volume model. The volume models were peeled and rotated to be screen captured. The captured images were loaded on user-friendly browsing software that had been made in the laboratory. RESULTS: The browsing software was downloadable from the authors' homepage (anatomy.co.kr). On the software, the volume model was peeled at 1 mm thicknesses and rotated at 30 degrees. Since the volume models were made from the cadaveric images, actual colors of the structures were displayed in high resolution. Thanks to the segmentation data, the structures on the volume model could be automatically annotated. Using the software, the sternocleidomastoid muscle and the internal jugular vein in the neck region, the cubital fossa in the upper limb region, and the femoral triangle in the lower limb region were observed to be described. CONCLUSION: For the students learning various medical procedures, the software presents the needed graphic information of the human body. The curved sectional planes are expected to be a tool for disciplinary convergence of the sectional anatomy and surface anatomy.
Anatomy, Cross-Sectional
;
Cadaver*
;
Comprehension
;
Education
;
Human Body
;
Humans
;
Imaging, Three-Dimensional
;
Jugular Veins
;
Learning
;
Lower Extremity
;
Male*
;
Neck
;
Upper Extremity
;
Visible Human Projects
10.Cerebral Venous Infarction Due to Brachial Artery-Jugular Vein Jump Graft in a Hemodialysis Patient
Inyoung CHOI ; Hyung Seok LEE ; Jae Sung LIM ; Kyung Ho YU
Journal of the Korean Neurological Association 2019;37(1):47-50
Hemodialysis patients rarely experience neurologic symptoms related to their vascular accesses. However, occlusion of venous drainage induces extreme venous hypertension and in rare cases cause intracranial venous congestion. We report a patient with cerebral venous infarction resulting from reflux flow into the cranium induced by an arteriovenous jump graft to the internal jugular vein. Clinicians should take into account the possibility of neurologic deficit related to intracranial venous hypertension in hemodialysis patients.
Arteriovenous Fistula
;
Drainage
;
Humans
;
Hyperemia
;
Hypertension
;
Infarction
;
Jugular Veins
;
Neurologic Manifestations
;
Renal Dialysis
;
Skull
;
Transplants
;
Veins

Result Analysis
Print
Save
E-mail