1.Analysis of CT imaging characteristics of high altitude pulmonary edema
Li-na YUE ; Gang CHEN ; Juan-qin NIU ; Ning-xia MU ; Yu-feng BAI ; Kang LIU
Chinese Medical Equipment Journal 2025;46(11):57-61
Objective To analyze the CT manifestations of high altitude pulmonary edema(HAPE)to provide radiological evidence for its early and accurate diagnosis.Methods Totally 200 HAPE patients clinically confirmed at some hospital from April 2021 to April 2024 were enrolled into a study group,and 56 individuals undergoing health examinations at the hospital's physical examination center between January and June 2023 were included into a control group.Examinations were carried out with a United Imaging uCT528 40-slice spiral CT scanner.The patients in the study group were observed in terms of HAPE staging,the extent of pulmonary involvement,CT manifestations of different stages including location,distribution,density and morphology of pulmonary lesion.The diameters of the main pulmonary arteries and ascending aortas of the subjects in the two groups were measured,and the ratios of the two diameters were calculated.SPSS 25.0 software was used for statistical analysis.Results In the study group,there were 26 cases(13.0%)at early stage,105 ones at progression stage(52.5%),32 ones at critical outbreak stage(16.0%)and 37 ones at resolution and absorption stage(18.5%),and there were 35.5%with unilateral lung involvement and 64.5%with bilateral involvement.At early stage,HAPE chest CT manifestations included increased and thickened bilateral bronchovascular bundles,widened main pulmonary artery lumen and faint ground-glass opacity in lungs;at progression stage,HAPE chest CT manifestations revealed multiple cloud-like or patchy areas of increased density within lungs;at critical outbreak stage,CT scanning indicated diffuse patchy opacities and consolidation in lungs,white lung-like changes could be found in some severe cases,and bronchial air signs were shown within affected segments in some ones with severer signs in the right lung than in the left lung;at resolution and absorption stage the CT manifestations were similar to those at early stage,with lesions completely resolving after treatment.The study group had the diameters of the main pulmonary arteries greater while the diameters of the ascending aortas less than those of the control group,and the ratios of the diameters of the two diameters in the study group were higher than those in the control group,with the differences being statistically significant(all P<0.05).Conclusion Chest CT is an important examination method for the early diagnosis of HAPE and clarification of its clinical staging,which directly reflects the pulmonary pathological changes in HAPE patients and helps doctors fully understand the disease progression.
2.The effectiveness of applying different tip positions of midline catheters:a Meta-analysis
Wanting SHENG ; Rui WANG ; Yuxiao ZHAO ; Pengfei QI ; Silong GAO ; Juan FENG ; Bohan LÜ ; Qun NIU ; Gang WANG
Chinese Journal of Nursing 2025;60(8):990-997
Objective To evaluate the effectiveness of different tip positions applied to midline catheters(MC)and provide evidence-based evidence for venous catheter tip positioning in clinical practice.Methods Computerized searches of PubMed,Web of Science,Embase,Cochrane Library,CINAHL,CNKI,Wanfang Database,VIP,and CBM for studies on the effectiveness of applying MC with different tip positions were performed from the time of database construction to July 2024.Meta-analysis was performed using Rev Man 5.3 software after 2 investigators independently screened the studies,extracted the information and evaluated the quality of the included studies.Results A total of 9 studies with 2 302 hospitalized patients were included.The quality evaluation results of the included studies are all B-level.Meta-analysis showed that when the tip of the MC was located in the subclavian vein compared with the tip of the MC in the axillary vein,the rate of total catheter-related complications,phlebitis,blood leakage,infiltration,catheter occlusion,catheter dislocation,and catheter-associated thrombosis were lower,with a statistically significant difference(P<0.05).When the tip of the MC was located in the subclavian vein compared with the tip of the MC in the axillary vein,the catheter retention time was longer,with a statistically significant difference(P=0.007).The descriptive analysis showed a lower rate of extubation due to complications when the tip of the MC was located in the subclavian vein compared with when the tip was located in the axillary vein(P<0.05).Conclusion When the tip of the MC is located in the subclavian vein compared to when it is located in the axillary vein,the incidence of total catheter-related complications,phlebitis,blood leakage,infiltration,catheter occlusion,catheter dislocation,catheter-associated thrombosis,and the rate of catheter extractions due to complications were lower,and the catheter was left in place for a longer period of time.Due to the limitations of the quantity and quality of the included studies,more large-sample,high-quality studies are needed to further validate the effectiveness of different tip positions of MC.
3.Analysis of CT imaging characteristics of high altitude pulmonary edema
Li-na YUE ; Gang CHEN ; Juan-qin NIU ; Ning-xia MU ; Yu-feng BAI ; Kang LIU
Chinese Medical Equipment Journal 2025;46(11):57-61
Objective To analyze the CT manifestations of high altitude pulmonary edema(HAPE)to provide radiological evidence for its early and accurate diagnosis.Methods Totally 200 HAPE patients clinically confirmed at some hospital from April 2021 to April 2024 were enrolled into a study group,and 56 individuals undergoing health examinations at the hospital's physical examination center between January and June 2023 were included into a control group.Examinations were carried out with a United Imaging uCT528 40-slice spiral CT scanner.The patients in the study group were observed in terms of HAPE staging,the extent of pulmonary involvement,CT manifestations of different stages including location,distribution,density and morphology of pulmonary lesion.The diameters of the main pulmonary arteries and ascending aortas of the subjects in the two groups were measured,and the ratios of the two diameters were calculated.SPSS 25.0 software was used for statistical analysis.Results In the study group,there were 26 cases(13.0%)at early stage,105 ones at progression stage(52.5%),32 ones at critical outbreak stage(16.0%)and 37 ones at resolution and absorption stage(18.5%),and there were 35.5%with unilateral lung involvement and 64.5%with bilateral involvement.At early stage,HAPE chest CT manifestations included increased and thickened bilateral bronchovascular bundles,widened main pulmonary artery lumen and faint ground-glass opacity in lungs;at progression stage,HAPE chest CT manifestations revealed multiple cloud-like or patchy areas of increased density within lungs;at critical outbreak stage,CT scanning indicated diffuse patchy opacities and consolidation in lungs,white lung-like changes could be found in some severe cases,and bronchial air signs were shown within affected segments in some ones with severer signs in the right lung than in the left lung;at resolution and absorption stage the CT manifestations were similar to those at early stage,with lesions completely resolving after treatment.The study group had the diameters of the main pulmonary arteries greater while the diameters of the ascending aortas less than those of the control group,and the ratios of the diameters of the two diameters in the study group were higher than those in the control group,with the differences being statistically significant(all P<0.05).Conclusion Chest CT is an important examination method for the early diagnosis of HAPE and clarification of its clinical staging,which directly reflects the pulmonary pathological changes in HAPE patients and helps doctors fully understand the disease progression.
4.Analysis of Clinical Features and Multi-Slice Spiral CT Image Features of Acute Appendicitis in Soldiers Who Have Been Living in Plateau for A Long Time
Li-na YUE ; Juan-qin NIU ; Gang CHEN ; Man-ping CHENG ; Ning-xia MU ; Jia FAN ; Kang LIU ; Yu-lan NIU ; Ya-ping HE ; Zhong-hua LI
Progress in Modern Biomedicine 2025;25(11):1869-1878
Objective:To investigate the clinical features and multi-slice spiral computed tomography(CT)imaging features of acute appendicitis in soldiers who have been living in plateau for a long time.Methods:The clinical features and imaging data of 56 cases of acute appendicitis in soldiers who have been living in plateau for a long time confirmed by surgery from February 2022 to August 2024 were retrospectively analyzed.Results:In 56 cases with acute appendicitis in soldiers who have been living in plateau for a long time,the appendectomy position results showed:anterior ileum 4 cases(7.14%),lower ileum 10 cases(17.86%),posterior cecum 16 cases(28.57%),lower cecum 9 cases(16.07%),lateral cecum 2 cases(3.58%),posterior ileum 6 cases(10.71%),high(subhepatic)9 cases(16.07%),and left lower abdominal 0 cases,retroperitoneal appendicitis 0 cases,which was suggested that the anatomical position variation of appendicitis in soldiers with acute appendicitis who have been living at high altitude for a long time was relatively large.The direct manifestations of multi-slice spiral CT showed:appendectomy enlarged diameter>6 mm in 49 cases(87.50%),appendicular wall thickening>2 mm in 42 cases(75.00%),ppendiceal dilation lumen and effusion in 29 cases(51.79%),appendix indistinctness in 3 cases(5.36%),lppendix fecalith:27 cases(48.21%),gas in the appendix in 16 cases(28.57%).Indirect findings of multi-slice spiral CT showed that,periappendiceal exudation with shadow in 32 cases(57.14%),appendiceal cellulitis with peripheral abscess in 9 cases(16.07%),peritonitis and ascites in 13 cases(23.21%),ileocecal intestinal wall thickening in 22 cases(39.29%),mesenteric lymph node enlargement in 16 cases(28.57%),reflexive intestinal stasis in ileocecal region was observed in 19 cases(33.93%).Conclusion:In the officers and soldiers with acute appendicitis who lived at high altitude for a long time,multi-slice spiral CT showed the direct manifestations of appendiceal thickening,tube wall thickening,lumen dilatation,fluid accumulation,etc.,and the indirect manifestations were periappendiceal exudation with shadow,appendiceal cellulitis with peripheral abscess,ileocecal intestinal wall thickening,reflexes of small intestine and mesenteric lymph node enlargement.Multi-slice spiral CT has the advantages of clear and intuitive,high safety,high resolution and simple operation in the diagnosis of acute appendicitis.
5.Effects of data-centric multi-task learning with larger patch sizes on pulmonary nodule segmentation performance
Jian LIU ; Zheng ZHANG ; Bing NIU ; Shuai KANG ; Juan REN ; Lei WANG ; Kai XU
Chinese Journal of Medical Physics 2025;42(10):1306-1320
Given the lack of annotations for key lung organs and tissues in existing public datasets,this study collected 863 cases of chest CT scan images and constructed the first comprehensive dataset containing annotations of pulmonary vessels,airways,and nodules using a semi-automated method that combines computer vision algorithms with manual corrections by radiologists.On this basis,a lung nodule segmentation model based on multi-task learning is proposed.By incorporating annotations of pulmonary vessels(pulmonary arteries and veins)and the trachea to enhance model's ability to learn lung features,the proposed model reduces the false discovery rate in lung nodule detection,and improves generalization ability.Additionally,the use of larger image patches further optimizes model performance.The trained VAAN_128 model achieves the best performance,with a Dice coefficient of 0.694 and a false discovery rate of 0.210 for lung nodule segmentation.Moreover,it simultaneously provides accurate segmentation results of pulmonary vessels and the trachea,assisting in the formulation of more precise diagnosis and treatment plans.Based on the VAAN_128 model,a software system for navigation and localization in biopsy procedures is developed.In clinical practice,this system can assist physicians in accurately locating lung nodules,distinguishing critical tissues,and improving preoperative planning efficiency.This provides precise and efficient technical support for early diagnosis and disease monitoring of lung diseases,and is of great significance for path planning in clinical navigation system and future lung imaging research.
6.Risk analysis for coil adverse events based on FDA MAUDE database
Jian-wei YANG ; Lin HUANG ; Yu-juan ZHAO ; Yi XUAN ; Jian-jun CAO ; Chang-qing LIU ; Hui-fang NIU ; Xia LI
Chinese Medical Equipment Journal 2025;46(6):83-87
The coil adverse events in the U.S.Food and Drug Administration Manufacturer and User Facility Device Experience(MAUDE)database from January 2021 to June 2024 were analyzed retrospectively.The risks of coils during the clinical application and their causes were explored with hospital survey and expert demonstration in Shandong Province.Some improving measures were put forward for the safe use of coils,including implementing the main responsibility of the registrant,enhancing the professional skills of the using institutions and strengthening the supervision of the supervisory authorities.[Chinese Medical Equipment Journal,2025,46(6):83-87]
7.Risk analysis for coil adverse events based on FDA MAUDE database
Jian-wei YANG ; Lin HUANG ; Yu-juan ZHAO ; Yi XUAN ; Jian-jun CAO ; Chang-qing LIU ; Hui-fang NIU ; Xia LI
Chinese Medical Equipment Journal 2025;46(6):83-87
The coil adverse events in the U.S.Food and Drug Administration Manufacturer and User Facility Device Experience(MAUDE)database from January 2021 to June 2024 were analyzed retrospectively.The risks of coils during the clinical application and their causes were explored with hospital survey and expert demonstration in Shandong Province.Some improving measures were put forward for the safe use of coils,including implementing the main responsibility of the registrant,enhancing the professional skills of the using institutions and strengthening the supervision of the supervisory authorities.[Chinese Medical Equipment Journal,2025,46(6):83-87]
8.The effectiveness of applying different tip positions of midline catheters:a Meta-analysis
Wanting SHENG ; Rui WANG ; Yuxiao ZHAO ; Pengfei QI ; Silong GAO ; Juan FENG ; Bohan LÜ ; Qun NIU ; Gang WANG
Chinese Journal of Nursing 2025;60(8):990-997
Objective To evaluate the effectiveness of different tip positions applied to midline catheters(MC)and provide evidence-based evidence for venous catheter tip positioning in clinical practice.Methods Computerized searches of PubMed,Web of Science,Embase,Cochrane Library,CINAHL,CNKI,Wanfang Database,VIP,and CBM for studies on the effectiveness of applying MC with different tip positions were performed from the time of database construction to July 2024.Meta-analysis was performed using Rev Man 5.3 software after 2 investigators independently screened the studies,extracted the information and evaluated the quality of the included studies.Results A total of 9 studies with 2 302 hospitalized patients were included.The quality evaluation results of the included studies are all B-level.Meta-analysis showed that when the tip of the MC was located in the subclavian vein compared with the tip of the MC in the axillary vein,the rate of total catheter-related complications,phlebitis,blood leakage,infiltration,catheter occlusion,catheter dislocation,and catheter-associated thrombosis were lower,with a statistically significant difference(P<0.05).When the tip of the MC was located in the subclavian vein compared with the tip of the MC in the axillary vein,the catheter retention time was longer,with a statistically significant difference(P=0.007).The descriptive analysis showed a lower rate of extubation due to complications when the tip of the MC was located in the subclavian vein compared with when the tip was located in the axillary vein(P<0.05).Conclusion When the tip of the MC is located in the subclavian vein compared to when it is located in the axillary vein,the incidence of total catheter-related complications,phlebitis,blood leakage,infiltration,catheter occlusion,catheter dislocation,catheter-associated thrombosis,and the rate of catheter extractions due to complications were lower,and the catheter was left in place for a longer period of time.Due to the limitations of the quantity and quality of the included studies,more large-sample,high-quality studies are needed to further validate the effectiveness of different tip positions of MC.
9.Efficacy analysis of netupitan/palonosetron in preventing nausea and vomiting caused by pre-treatment chemotherapy before transplantations
Xiaoqing CHEN ; Zhigang LIU ; Jie JI ; Qiuhui WU ; Juan XU ; Pu KUANG ; Ting NIU
Chongqing Medicine 2025;54(6):1339-1344,1350
Objective To observe the effectiveness and safety of netupitant/palonosetron in the treat-ment of chemotherapy-induced nausea and vomiting(CINV)in hematologic tumor patients undergoing autol-ogous and allogeneic stem cell transplantation.Methods Adult hematologic tumor patients who received net-upitant/palonosetron to prevent chemotherapy-induced nausea and vomiting CINV during pre-transplant chemotherapy at West China Hospital of Sichuan University from January to September 2022 were collected.On the first and third day of pre-transplant chemotherapy,netupitant/palonosetron was orally administered one hour before the infusion of pre-transplant chemotherapy drugs,for a total of two doses.The nausea and CINV status of the patients from the start of pre-transplant chemotherapy to 7 days after stem cell infusion were recorded.Results As a result,a total of 125 patients with hematological tumors were included,and the complete remission rates during pre-treatment chemotherapy were 72.8%,80.0%and 66.4%in the acute phase,delayed phase,and total phase,respectively.The rates of no vomiting were 89.6%,92.0%and 72.8%,respectively.The rates of no rescue medication were 95.2%,93.6%and 73.6%,respectively.The complete remission rate of 33 plasma cell tumors and 46 leukemia and myelodysplastic syndrome patients exceeded 70%,and the complete remission rate of 46 lymphoma patients exceeded 90%.The complete response rate in the delayed phase of the pre-treatment CHiGCB regimen(chidamide+busulfan+gemcitabine+cladribine)was 93.5%,which was higher than the complete response rate of the BenMel regimen(bendamustine+mel-phalan)(72.7%)and the CHiFAB regimen(chidamide+busulfan+fludarabine+cytarabine)(71.7%).The complete remission rate during the follow-up period of the CHiGCB regimen was 91.3%,which was higher than that of the CHiFAB regimen(65.2%),with the statistically significance(P<0.05).Conclusion Netu-pitant/palonosetron can effectively control CINV in patients undergoing autologous or allogeneic hematopoiet-ic stem cell transplantation for hematologic tumors.
10.Effects of data-centric multi-task learning with larger patch sizes on pulmonary nodule segmentation performance
Jian LIU ; Zheng ZHANG ; Bing NIU ; Shuai KANG ; Juan REN ; Lei WANG ; Kai XU
Chinese Journal of Medical Physics 2025;42(10):1306-1320
Given the lack of annotations for key lung organs and tissues in existing public datasets,this study collected 863 cases of chest CT scan images and constructed the first comprehensive dataset containing annotations of pulmonary vessels,airways,and nodules using a semi-automated method that combines computer vision algorithms with manual corrections by radiologists.On this basis,a lung nodule segmentation model based on multi-task learning is proposed.By incorporating annotations of pulmonary vessels(pulmonary arteries and veins)and the trachea to enhance model's ability to learn lung features,the proposed model reduces the false discovery rate in lung nodule detection,and improves generalization ability.Additionally,the use of larger image patches further optimizes model performance.The trained VAAN_128 model achieves the best performance,with a Dice coefficient of 0.694 and a false discovery rate of 0.210 for lung nodule segmentation.Moreover,it simultaneously provides accurate segmentation results of pulmonary vessels and the trachea,assisting in the formulation of more precise diagnosis and treatment plans.Based on the VAAN_128 model,a software system for navigation and localization in biopsy procedures is developed.In clinical practice,this system can assist physicians in accurately locating lung nodules,distinguishing critical tissues,and improving preoperative planning efficiency.This provides precise and efficient technical support for early diagnosis and disease monitoring of lung diseases,and is of great significance for path planning in clinical navigation system and future lung imaging research.

Result Analysis
Print