1.Construction of milk donation of self-efficacy scale and test of reliability and validity for lost newborns based on COSMIN
Ronghua XIAN ; Ju YANG ; Li LIU ; Mei HE ; Yuan ZHANG ; Biao SHANG
Chinese Journal of Practical Nursing 2025;41(20):1581-1587
Objective:To develop a self-efficacy scale of milk donation and test its reliability and validity, in order to provide a scientific evaluation tool for the corresponding study.Methods:According to Bandura′s self-efficacy theory and consensus-based standards for the selection of health measurement instruments, the scale was developed by means of literature search, article pool establishment and expert letter consultation. A pre-survey was conducted on 30 newborn bereaved women, a formal investigation was conducted on 231 newborn bereaved women, and 115 newborn bereaved women were selected for exploratory factor analysis. Confirmatory factor analysis was performed on 116 parturients with neonatal loss to determine the reliability and validity of the scale.Results:The final scale includes 3 dimensions and 13 items. Three common factors were extracted by exploratory factor analysis, and the cumulative variance contribution rate was 77.962%. A scale with three dimensions, included breast milk donation resilience, breast milk donation cognition and breast milk donation motivation, and 13 items was determined. Confirmatory factor analysis showed that the model fit of the scale was good ( χ2/ df = 1.390, RMSEA = 0.063, RMR = 0.046, NFI = 0.924, NNFI = 0.971, GFI = 0.924, CFI = 0.977). The content validity index was 0.835. Cronbach′s α coefficient of the total volume table was 0.919, and the coefficients of each dimension were 0.892, 0.905 and 0.844, respectively. The broken half reliability of the scale was 0.893, and the broken half reliability of each dimension was 0.857, 0.881 and 0.711, respectively. The retest reliability of the scale was 0.814, and the retest reliability of each dimension was 0.803, 0.825 and 0.767, respectively. Conclusions:The scale has good reliability and validity, and can be used to evaluate the self-efficacy of milk donation in lost newborns.
2.Ultrasound radiomics combined with machine learning for early diagnosis of seronegative hashimoto’s thyroiditis
Wenjun WU ; Chang LIU ; Shengsheng YAO ; Daming LIU ; Yuan LUO ; Yihan SUN ; Ting RUAN ; Mengyou LIU ; Li SHI ; Mingming XIAO ; Qi ZHANG ; Zhengshuai LIU ; Xingai JU ; Jiahao WANG ; Xiang FEI ; Li LU ; Yang GAO ; Ying ZHANG ; Liying GONG ; Xuanyu CHEN ; Wanli ZHENG ; Xiali NIU ; Xiao YANG ; Huimei CAO ; Shijie CHANG ; Zuoxin MA ; Jianchun CUI
Chinese Journal of Endocrine Surgery 2025;19(3):313-319
Objective:To evaluate the value of ultrasound radiomics combined with machine learning for early diagnosis of seronegative Hashimoto’s thyroiditis (SN-HT) .Methods:This retrospective study included 164 patients from Liaoning Provincial People’s Hospital , Lixin County People’s Hospital, Linghai Dalinghe Hospital, Fengcheng Phoenix Hospital, who underwent thyroidectomy for solitary nodules with normal thyroid function between Nov. 2016 and Jan. 2024. Postoperative pathology confirmed Hashimoto’s thyroiditis (HT) in some cases, who were further categorized into antibody-positive and antibody-negative groups based on serum antibody status. Patients without Hashimoto’s thyroiditis served as the control group. A total of 298 ultrasound images were analyzed. Radiomics features were extracted from hypoechoic non-nodular areas within 0.5 cm surrounding the tumor. Two senior pathologists and two senior ultrasound physicians independently assessed lymphocytic infiltration, eosinophilic changes of follicular epithelium, and the proportion of hypoechoic areas in pathology and ultrasound images, respectively. A machine learning model, CCH-NET, was developed using linear regression and t-distributed stochastic neighbor embedding (t-SNE) techniques. The dataset was divided into a training set (80%) and a validation set (20%) to compare the diagnostic accuracy of CCH-NET with that of senior ultrasound physicians. Results:In internal validation, CCH-NET achieved a diagnostic accuracy of 88.89% for both antibody-positive and antibody-negative groups, significantly higher than the 66.67% accuracy of senior ultrasound physicians ( P<0.01). In external validation, CCH-NET achieved 75.00% and 66.67% accuracy for the two groups, compared to 50.00% by senior ultrasound physicians. For the control group, both methods achieved 93.33% accuracy. The AUC of CCH-NET was 0.848, outperforming senior ultrasound physicians (0.681) ,demonstrating superior diagnostic performance. Conclusion:The radiomics-based CCH-NET model, using non-nodular hypoechoic areas as a specific indicator, can accurately identify early SN-HT in euthyroid patients. It significantly outperforms senior ultrasound physicians, improving diagnostic accuracy and reducing missed diagnoses.
3.Effects of Kanxin Powder on Neuroinflammation in APP/PS1 Mice Based on WDFY1/TLR4/NF-κB Signaling Pathway
Yali YANG ; Dongyu MIN ; Yongming LIU ; Changbin YUAN ; Yetao JU ; Yuanyu LIANG ; Meijia CHENG ; Xiaoming HE ; Changyang YU ; Li ZHANG
Chinese Journal of Information on Traditional Chinese Medicine 2025;32(5):90-97
Objective To observe the effect of Kaixin Powder on neuroinflammation in APP/PS1 mice by regulating WDFY1/TLR4/NF-κB signaling pathway;To explore its mechanism of intervening in Alzheimer disease(AD).Methods APP/PS1 transgenic mice were randomly divided into model group,donepezil hydrochloride group(0.66 mg/kg),and Kaixin Powder low-,medium-and high-dosage groups(1.625,3.25,6.5 g/kg),C57BL/6J mice were set as blank control group,with 8 mice in each group,and corresponding drug intervention was given to medicaction group for 24 weeks.Morris water maze,Y maze and novel object recognition experiments were conducted to assess the cognitive function and learning and memory abilities of mice,immunohistochemical staining was used to detect the deposition of β-amyloid protein(Aβ)in hippocampus,the morphology and Nissl bodies of hippocampal CA1 neurons were observed using HE staining and Nissl staining,ELISA was used to detect the serum contents of interleukin(IL)-6,IL-17,IL-1β and tumor necrosis factor-α(TNF-α),Western blot was used to detect the protein expression of calcium-binding adapter molecule 1(Iba1),glial fibrillary acidic protein(GFAP),WDFY1,Toll like receptor 4(TLR4),Toll like receptor associated molecule(TRAM),TIR domain adapter protein(TRIF),NF-κB p65 and p-NF-κB p65 in hippocampal tissue,RT-qPCR was used to detect the mRNA expression of WDFY1,TLR4,TRAM,TRIF and NF-κB p65 in hippocampal tissue.Results Compared with the blank control group,the model group had significantly prolonged escape latency,reduced platform crossings,decreased autonomous reaction alternation rate and relative recognition index(P<0.05,P<0.01),with increased deposition of Aβ in hippocampal tissue(P<0.01),damaged morphological structure of neurons,reduced number of neurons and Nissl bodies,the serum contents of IL-6,IL-17,IL-1β and TNF-α significantly increased,the expression of Iba1,GFAP,WDFY1,TLR4,TRAM,TRIF,p-NF-κB p65 protein and WDFY1,TLR4,TRAM,TRIF mRNA in hippocampal tissue significantly increased(P<0.01).Compared with the model group,Kaixin Powder groups and donepezil hydrochloride group had significantly shortened escape latency and increased platform crossings,autonomous reaction alternation rate and relative recognition index(P<0.05,P<0.01),hippocampal Aβ deposition reduced in Kaixin Powder medium-,high-dosage groups and donepezil hydrochloride group,the morphological structure of neurons recovered,the number of neurons and Nissl bodies increased,the serum contents of IL-6,IL-17,IL-1β and TNF-α significantly decreased(P<0.05,P<0.01),and the protein expression of Iba1,GFAP,WDFY1,TLR4,TRAM,TRIF,p-NF-κB p65 and the mRNA expressions of WDFY1,TLR4,TRAM and TRIF in hippocampal tissue significantly decreased(P<0.05,P<0.01).Conclusion Kaixin Powder can improve cognitive function and learning and memory abilities in AD model mice,alleviate hippocampal neuron damage and Aβ deposition,inhibit the activation of microglia and astrocytes,and thereby reduce serum inflammatory cytokine release.Its mechanism may be related to regulating the WDFY1/TLR4/NF-κB signaling pathway to inhibit neuroinflammation.
4.Ultrasound radiomics combined with machine learning for early diagnosis of seronegative hashimoto’s thyroiditis
Wenjun WU ; Chang LIU ; Shengsheng YAO ; Daming LIU ; Yuan LUO ; Yihan SUN ; Ting RUAN ; Mengyou LIU ; Li SHI ; Mingming XIAO ; Qi ZHANG ; Zhengshuai LIU ; Xingai JU ; Jiahao WANG ; Xiang FEI ; Li LU ; Yang GAO ; Ying ZHANG ; Liying GONG ; Xuanyu CHEN ; Wanli ZHENG ; Xiali NIU ; Xiao YANG ; Huimei CAO ; Shijie CHANG ; Zuoxin MA ; Jianchun CUI
Chinese Journal of Endocrine Surgery 2025;19(3):313-319
Objective:To evaluate the value of ultrasound radiomics combined with machine learning for early diagnosis of seronegative Hashimoto’s thyroiditis (SN-HT) .Methods:This retrospective study included 164 patients from Liaoning Provincial People’s Hospital , Lixin County People’s Hospital, Linghai Dalinghe Hospital, Fengcheng Phoenix Hospital, who underwent thyroidectomy for solitary nodules with normal thyroid function between Nov. 2016 and Jan. 2024. Postoperative pathology confirmed Hashimoto’s thyroiditis (HT) in some cases, who were further categorized into antibody-positive and antibody-negative groups based on serum antibody status. Patients without Hashimoto’s thyroiditis served as the control group. A total of 298 ultrasound images were analyzed. Radiomics features were extracted from hypoechoic non-nodular areas within 0.5 cm surrounding the tumor. Two senior pathologists and two senior ultrasound physicians independently assessed lymphocytic infiltration, eosinophilic changes of follicular epithelium, and the proportion of hypoechoic areas in pathology and ultrasound images, respectively. A machine learning model, CCH-NET, was developed using linear regression and t-distributed stochastic neighbor embedding (t-SNE) techniques. The dataset was divided into a training set (80%) and a validation set (20%) to compare the diagnostic accuracy of CCH-NET with that of senior ultrasound physicians. Results:In internal validation, CCH-NET achieved a diagnostic accuracy of 88.89% for both antibody-positive and antibody-negative groups, significantly higher than the 66.67% accuracy of senior ultrasound physicians ( P<0.01). In external validation, CCH-NET achieved 75.00% and 66.67% accuracy for the two groups, compared to 50.00% by senior ultrasound physicians. For the control group, both methods achieved 93.33% accuracy. The AUC of CCH-NET was 0.848, outperforming senior ultrasound physicians (0.681) ,demonstrating superior diagnostic performance. Conclusion:The radiomics-based CCH-NET model, using non-nodular hypoechoic areas as a specific indicator, can accurately identify early SN-HT in euthyroid patients. It significantly outperforms senior ultrasound physicians, improving diagnostic accuracy and reducing missed diagnoses.
5.Therapeutic effect of neurosurgical robot-assisted stereotactic puncture and drainage for brain abscess
Xu RAN ; Jing-peng LIU ; Ju-hong PENG ; Zuo-xin ZHANG ; Yuan XIE ; Yan XIANG ; Lin YANG ; Jin-bo YIN ; Guo-long LIU ; Sheng-qing LYU
Journal of Regional Anatomy and Operative Surgery 2025;34(11):987-992
Objective To evaluate the clinical outcome of neurosurgical robot-assisted stereotactic puncture and drainage for brain abscess.Methods A retrospective analysis was conducted on the clinical data of 53 patients with brain abscess admitted to our hospital from January 2018 to December 2024.Among them,29 cases underwent craniotomy for abscess resection(craniotomy group),while 24 cases received neurosurgical robot-assisted stereotactic puncture and drainage(robot-assisted group).The operation time,intraoperative blood loss,decompressive craniectomy rate,proportion of postoperative antibiotic regimen adjustment,postoperative hospital stay,incidence of postoperative complications,mortality rate and Glasgow outcome scale(GOS)scores 6 months after surgery of patients were compared between the two groups.Results Compared with the craniotomy group,the robot-assisted group demonstrated significantly shorter operation time,less intraoperative blood loss,and lower incidence of postoperative complication,the differences were all statistically significant(P<0.05).However,there were no statistically significant differences in terms of decompressive craniectomy rate,postoperative hospital stay,mortality rate,GOS score,or proportion of the postoperative antibiotic regimen adjustment between the two groups(P>0.05).Conclusion As a precise and minimally invasive surgical method,neurosurgical robot-assisted stereotactic puncture and drainage for patients with brain abscess can effectively improve the operational efficiency,shorten the operation time,reduce intraoperative injury,and lower the risk of postoperative complications.It has high clinical application value and potential for widespread adoption.
6.Clinical efficacy of Wenshen Chushi Decoction combined with LIPUS on erectile dysfunction with renal deficiency and phlegm-dampness syndrome
Wen-xiong ZHU ; Yi-feng YUAN ; Tao LIU ; Bo LI ; Liu-ya LONG ; Qi-hua CHEN ; Ju-qiao HE
National Journal of Andrology 2025;31(6):519-525
Objective:To explore the clinical efficacy of Wenshen Chushi Decoction combined with low intensity pulsed ultra-sound(LIPUS)on erectile dysfunction(ED)caused by renal deficiency and phlegm-dampness syndrome.Methods:One hundred and twenty ED patients were included from the Department of Andrology in the First Hospital of Hunan University of Traditional Chinese Medicine.The patients in control group were treated with Wenshen Chushi Decoction.While the patients in observation group were trea-ted with Wenshen Chushi Decoction combined with LIPUS for 8 consecutive weeks.After the treatment,the efficacy was evaluated using the International Index of Erectile Function-5(IIEF-5)score,Penile Flow Index(PFI),Traditional Chinese Medicine Syndrome Score,Self-Rating Depression Scale(SDS)score,and Self-Rating Anxiety Scale(SAS)score.Safety was also observed.And the ef-ficacy was followed up 4 weeks after the end of treatment.Results:Fifty-seven cases were enrolled into control group finally with 55 cases in the treatment group.After the treatment,all the patients in both of groups showed an improvement in IIEF-5 scores(P<0.01).Compared with the control group(19.09±2.22),the IIEF-5 score in observation group(20.42±2.39)increased signifi-cantly(P<0.01).After the treatment,the scores of PFI,TCM syndrome and SDS in both groups decreased(P<0.01,P<0.05,P<0.01).Compared with the control group([3.77±1.21],[9.91±1.71]and[39.88±2.63]points),the observation group([2.92±1.08],[4.78±1.45],and[34.51±2.09]points)showed a more significant decrease(P<0.01).There was no significant difference in total effective rate between the two groups(P>0.05).During follow-up,the IIEF-5 scores of both groups of patients were higher than those before(P<0.05,P<0.01),and the observation group score was higher than that in the control group([17.15±3.37]vs[13.63±1.96],P<0.01).No adverse reaction and abnormality of indicators occurred in both of two groups.Conclusion:Wenshen Chushi Decoction has a significant therapeutic effect on ED caused by renal deficiency and phlegm-dampness syndrome.It can not only improve the quality of erection,but also improve the physical and mental symptoms associated with ED,which makes therapeutic effect lasting longer.
7.Ibuprofen Oral Administration Protocols for Analgesia After Cesarean Delivery: A Prospective Randomized Controlled Study
Shuang LI ; Ju BAO ; Yuan QU ; Bo ZHANG ; Xinni CAO ; Yanping HUANG ; Zhe LIU
Maternal-Fetal Medicine 2025;07(2):69-75
Objective::To compare the analgesic effects of ibuprofen administered orally via two modes combined with a conventional, patient-controlled intravenous analgesia pump on maternal pain after cesarean section (CS).Methods::This prospective, randomized, controlled study enrolled females who underwent CS from August 2022 to August 2023 at Peking University First Hospital, Beijing, China. Participants were randomly assigned to either an as-needed ibuprofen group (300 mg orally upon request) or a scheduled ibuprofen group (300 mg every 12 hours for 48 hours). The primary outcomes assessed were postoperative pain levels using the Wong-Baker Faces Pain Scale-Revised and cumulative oxycodone consumption at multiple time points up to 48 hours post-delivery. Secondary outcomes included recovery parameters (time to first flatus, ambulation, and lactation initiation), patient satisfaction with pain control, and postpartum depression scores evaluated by the Edinburgh Postnatal Depression Scale on postoperative day 3. Normally distributed data analyzed with t-tests; non-normal data with Mann-Whitney U tests; categorical variables with chi-square or Fisher’s exact tests (SPSS 26.0, P < 0.05). Results::After excluding 61 non-eligible cases, 339 patients were included (171 as-needed vs. 168 scheduled). The scheduled group showed significantly better pain control at 12 hours (4.00 (2.00-5.50) vs. 4.00 (4.00-6.00), P < 0.001), 24 hours (4.00 (2.00-4.00) vs. 4.00 (2.00-6.00), P < 0.001), and 36 hours (2.00 (2.00-4.00) vs. 4.00 (2.00-4.00), P < 0.001), and 48 hours (2.00 (2.00-4.00) vs. 2.00 (2.00-4.00), P = 0.004) post-delivery and lower levels of oxycodone consumption at 36 hours (10.20 (8.20-13.35) vs. 11.00 (8.80-14.40), P = 0.042) and 48 hours (12.40 (10.40-15.95) vs. 13.80 (11.00-16.00), P = 0.020) postpartum compared with those in the as-needed group. Additionally, the time to the return of bowel movements was shorter in the scheduled group than in the as-needed group (23.50 (16.94, 31.47) vs. 27.00 (19.88, 35.97), P = 0.004). Differences in post-delivery ambulation, lactation initiation, satisfaction levels, and depression scores were not significantly different between the two groups. Conclusion::The results of this study promote the use of ibuprofen (scheduled oral administration) combined with a conventional, patient-controlled intravenous analgesia pump for achieving better post-CS pain control than an as-needed dosage regimen.Registration::Chinese Clinical Trial Registry, ChiCTR2400082474.
8.Ibuprofen Oral Administration Protocols for Analgesia After Cesarean Delivery: A Prospective Randomized Controlled Study
Shuang LI ; Ju BAO ; Yuan QU ; Bo ZHANG ; Xinni CAO ; Yanping HUANG ; Zhe LIU
Maternal-Fetal Medicine 2025;07(2):69-75
Objective::To compare the analgesic effects of ibuprofen administered orally via two modes combined with a conventional, patient-controlled intravenous analgesia pump on maternal pain after cesarean section (CS).Methods::This prospective, randomized, controlled study enrolled females who underwent CS from August 2022 to August 2023 at Peking University First Hospital, Beijing, China. Participants were randomly assigned to either an as-needed ibuprofen group (300 mg orally upon request) or a scheduled ibuprofen group (300 mg every 12 hours for 48 hours). The primary outcomes assessed were postoperative pain levels using the Wong-Baker Faces Pain Scale-Revised and cumulative oxycodone consumption at multiple time points up to 48 hours post-delivery. Secondary outcomes included recovery parameters (time to first flatus, ambulation, and lactation initiation), patient satisfaction with pain control, and postpartum depression scores evaluated by the Edinburgh Postnatal Depression Scale on postoperative day 3. Normally distributed data analyzed with t-tests; non-normal data with Mann-Whitney U tests; categorical variables with chi-square or Fisher’s exact tests (SPSS 26.0, P < 0.05). Results::After excluding 61 non-eligible cases, 339 patients were included (171 as-needed vs. 168 scheduled). The scheduled group showed significantly better pain control at 12 hours (4.00 (2.00-5.50) vs. 4.00 (4.00-6.00), P < 0.001), 24 hours (4.00 (2.00-4.00) vs. 4.00 (2.00-6.00), P < 0.001), and 36 hours (2.00 (2.00-4.00) vs. 4.00 (2.00-4.00), P < 0.001), and 48 hours (2.00 (2.00-4.00) vs. 2.00 (2.00-4.00), P = 0.004) post-delivery and lower levels of oxycodone consumption at 36 hours (10.20 (8.20-13.35) vs. 11.00 (8.80-14.40), P = 0.042) and 48 hours (12.40 (10.40-15.95) vs. 13.80 (11.00-16.00), P = 0.020) postpartum compared with those in the as-needed group. Additionally, the time to the return of bowel movements was shorter in the scheduled group than in the as-needed group (23.50 (16.94, 31.47) vs. 27.00 (19.88, 35.97), P = 0.004). Differences in post-delivery ambulation, lactation initiation, satisfaction levels, and depression scores were not significantly different between the two groups. Conclusion::The results of this study promote the use of ibuprofen (scheduled oral administration) combined with a conventional, patient-controlled intravenous analgesia pump for achieving better post-CS pain control than an as-needed dosage regimen.Registration::Chinese Clinical Trial Registry, ChiCTR2400082474.
9.Mechanism of Action of Kaixinsan in Ameliorating Alzheimer's Disease
Xiaoming HE ; Xiaotong WANG ; Dongyu MIN ; Xinxin WANG ; Meijia CHENG ; Yongming LIU ; Yetao JU ; Yali YANG ; Changbin YUAN ; Changyang YU ; Li ZHANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(1):20-29
ObjectiveTo investigate the mechanism of action of Kaixinsan in the treatment of Alzheimer's disease (AD) based on network pharmacology, molecular docking, and animal experimental validation. MethodsThe Traditional Chinese Medicine Systems Pharmacology Database and Analysis Platform(TCMSP) and the Encyclopedia of Traditional Chinese Medicine(ETCM) databases were used to obtain the active ingredients and targets of Kaixinsan. GeneCards, Online Mendelian Inheritance in Man(OMIM), TTD, PharmGKB, and DrugBank databases were used to obtain the relevant targets of AD. The intersection (common targets) of the active ingredient targets of Kaixinsan and the relevant targets of AD was taken, and the network interaction analysis of the common targets was carried out in the STRING database to construct a protein-protein interaction(PPI) network. The CytoNCA plugin within Cytoscape was used to screen out the core targets, and the Metascape platform was used to perform gene ontology(GO) functional enrichment analysis and Kyoto encyclopedia of genes and genomes(KEGG) pathway enrichment analysis. The “drug-active ingredient-target” interaction network was constructed with the help of Cytoscape 3.8.2, and AutoDock Vina was used for molecular docking. Scopolamine (SCOP) was utilized for modeling and injected intraperitoneally once daily. Thirty-two male C57/BL6 mice were randomly divided into blank control (CON) group (0.9% NaCl, n=8), model (SCOP) group (3 mg·kg-1·d-1, n=8), positive control group (3 mg·kg-1·d-1 of SCOP+3 mg·kg-1·d-1 of Donepezil, n=8), and Kaixinsan group (3 mg·kg-1·d-1 of SCOP+6.5 g·kg-1·d-1 of Kaixinsan, n=8). Mice in each group were administered with 0.9% NaCl, Kaixinsan, or Donepezil by gavage twice a day for 14 days. Morris water maze experiment was used to observe the learning memory ability of mice. Hematoxylin-eosin (HE) staining method was used to observe the pathological changes in the CA1 area of the mouse hippocampus. Enzyme linked immunosorbent assay(ELISA) was used to determine the serum acetylcholine (ACh) and acetylcholinesterase (AChE) contents of mice. Western blot method was used to detect the protein expression levels of signal transducer and activator of transcription 3(STAT3) and nuclear transcription factor(NF)-κB p65 in the hippocampus of mice. ResultsA total of 73 active ingredients of Kaixinsan were obtained, and 578 potential targets (common targets) of Kaixinsan for the treatment of AD were screened out. Key active ingredients included kaempferol, gijugliflozin, etc.. Potential core targets were STAT3, NF-κB p65, et al. GO functional enrichment analysis obtained 3 124 biological functions, 254 cellular building blocks, and 461 molecular functions. KEGG pathway enrichment obtained 248 pathways, mainly involving cancer-related pathways, TRP pathway, cyclic adenosine monophosphate(cAMP) pathway, and NF-κB pathway. Molecular docking showed that the binding of the key active ingredients to the target targets was more stable. Morris water maze experiment indicated that Kaixinsan could improve the learning memory ability of SCOP-induced mice. HE staining and ELISA results showed that Kaixinsan had an ameliorating effect on central nerve injury in mice. Western blot test indicated that Kaixinsan had a down-regulating effect on the levels of NF-κB p65 phosphorylation and STAT3 phosphorylation in the hippocampal tissue of mice in the SCOP model. ConclusionKaixinsan can improve the cognitive impairment function in SCOP model mice and may reduce hippocampal neuronal damage and thus play a therapeutic role in the treatment of AD by regulating NF-κB p65, STAT3, and other targets involved in the NF-κB signaling pathway.
10.Application progress on functional insoles in the prevention and treatment of diabetic foot.
Heng-Yu LIU ; Zhen-de JIANG ; Yao-Kuan RUAN ; Qiu-Ju LI ; Si-Yuan CHEN ; Shun-Yu WEI ; Nan MEI ; Chou WU ; Fei CHANG
China Journal of Orthopaedics and Traumatology 2025;38(9):969-975
Diabetic foot (DF) is one of the most serious chronic complications of diabetes. The incidence rate among global diabetes patients is as high as 15% to 25%, and about 50% of patients will develop contralateral foot ulcers within 5 years after the first unilateral ulcer. As a non-invasive prevention and control solution, the application progress of functional insoles is mainly reflected in the following aspects:(1) Material innovation. The application of new composite materials and smart materials has significantly enhanced the pressure reduction effect and comfort. (2) Structural optimization. The development of multi-layer design and local pressure reduction structure has achieved more precise pressure distribution regulation. (3) Manufacturing process. 3D printing and parametric design have enabled the personalized customization of functional insoles. (4) Intelligent monitoring. It integrates functions such as pressure sensing and temperature monitoring, achieving real-time monitoring and early warning of foot conditions. Clinical research has confirmed that personalized functional insoles could reduce the incidence of foot ulcers and shorten the healing time of ulcers. At present, the research hotspots mainly focus on the development of smart materials, the construction of multi-functional integration and remote monitoring systems. However, in-depth research is still needed in the aspects of biomechanical mechanisms, standardized evaluation systems and long-term efficacy assessment. The development of future functional insoles should focus on the coordinated advancement of "personalization-intelligence-standardization", with the aim of providing more effective solutions for the prevention and treatment of DF.
Humans
;
Diabetic Foot/therapy*
;
Foot Orthoses

Result Analysis
Print
Save
E-mail