1.Investigation of natural radionuclide activity in drinking water in Hohhot, China
Bo JU ; Yulong BAO ; Shuai ZHANG ; Xiang LIU ; Xiao XU ; Zhichao SUN ; Xiaojuan YANG
Chinese Journal of Radiological Health 2026;35(2):159-164
Objective To investigate the activity concentrations of natural radionuclides in drinking water (tap water and well water) in urban and rural areas of Hohhot, assess the safety of drinking water, and to provide data support for local drinking water radioactivity monitoring and management. Methods Representative samples of well water and tap water were collected from nine banners/counties/districts in Hohhot. Activity concentrations were measured using a low-background gross α/β counter, an α spectrometer, inductively coupled plasma mass spectrometry, and a radium/radon analyzer. Results A total of nine tap water samples and nine well water samples were analyzed. For the tap water samples, gross α activity concentrations ranged from 0.093 to 0.193 Bq/L, gross β from 0.091 to 0.225 Bq/L, uranium mass concentrations from 2.32 to 10.36 μg/L, thorium mass concentrations from 0.09 to 0.20 μg/L,210Po activity concentrations from below the minimum detectable limit to 0.41 mBq/L, and 226Ra activity concentrations from 8.70 to 13.35 mBq/L. For the well water samples, gross α activity concentrations ranged from 0.111 to 0.203 Bq/L, gross β from 0.111 to 0.270 Bq/L, uranium mass concentrations from 2.31 to 13.28 μg/L, thorium mass concentrations from 0.17 to 0.26 μg/L,210Po activity concentrations from 1.03 to 2.12 mBq/L, and 226Ra activity concentrations from 15.38 to 23.63 mBq/L. Conclusion The activity concentrations of natural radionuclides in both well water and tap water in the Hohhot region were at environmental background levels and met national drinking water hygiene standards.
2.Effect of Kuanxiong Aerosol on Perioperative Coronary Microcirculation in Patients with Unstable Angina Undergoing Elective PCI: A Pilot Randomized Controlled Trial.
Zi-Hao LIU ; Wen-Long XING ; Hong-Xu LIU ; Ju-Ju SHANG ; Ai-Yong LI ; Qi ZHOU ; Zhen-Min ZHANG ; Zhi-Bao LI ; Ke-Ji CHEN
Chinese journal of integrative medicine 2025;31(3):206-214
OBJECTIVE:
To evaluate the immediate effect of Kuanxiong Aerosol (KXA) on perioperative coronary microcirculation in patients with unstable angina (UA) suffering from elective percutaneous coronary intervention (PCI).
METHODS:
From February 2021 to July 2023, UA inpatients who underwent PCI alone in the left anterior descending (LAD) branch were included. Random numbers were generated to divide patients into the trial group and the control group at a ratio of 1:1. The index of coronary microcirculation resistance (IMR) was measured before PCI, and the trial group was given two sprays of KXA, while the control group was not given. IMR was measured again after PCI, cardiac troponin I (cTnI) and creatine kinase isoenzyme-MB (CK-MB) were detected before and 24 h after surgery, and major cardiovascular adverse events (MACEs) were recorded for 30 days. The data statistics and analysis personnel were blinded.
RESULTS:
Totally 859 patients were screened, and 62 of them were involved into this study. Finally, 1 patient in the trial group failed to complete the post-PCI IMR and was excluded, 30 patients were included for data analysis, while 31 patients in the control group were enrolled in data analysis. There was no significant difference in baseline data (age, gender, risk factors, previous history, biochemical index, and drug therapy, etc.) between the two groups. In addition, differences in IMR, cTnI and CK-MB were not statistically significant between the two groups before surgery. After PCI, the IMR level of the trial group was significantly lower than that of the control group (19.56 ± 14.37 vs. 27.15 ± 15.03, P=0.048). Besides, the incidence of perioperative myocardial injury (PMI) was lower in the trial group, but the difference was not statistically significant (6.67% vs. 16.13%, P=0.425). No MACEs were reported in either group.
CONCLUSIONS
KXA has the potential of improving coronary microvascular dysfunction. This study provides reference for the application of KXA in UA patients undergoing elective PCI. (Registration No. ChiCTR2300069831).
Humans
;
Percutaneous Coronary Intervention
;
Male
;
Microcirculation/drug effects*
;
Female
;
Angina, Unstable/physiopathology*
;
Pilot Projects
;
Middle Aged
;
Aged
;
Drugs, Chinese Herbal/pharmacology*
;
Aerosols
;
Troponin I/blood*
;
Coronary Circulation/drug effects*
;
Elective Surgical Procedures
3.Clinical application of bilateral targeted puncture based on vertebral osteodense zone in percutaneous vertebroplasty.
Bao-Xin JIA ; Jing JU ; Cheng-Zhou LIU ; Xiao-Qiang GAO ; Ting WANG
China Journal of Orthopaedics and Traumatology 2025;38(7):729-736
OBJECTIVE:
To investigate the clinical efficacy of bilateral targeted puncture in percutaneous vertebroplasty(PVP) based on the vertebral osteodense zone.
METHODS:
A retrospective analysis was conducted on 76 patients with fresh symptomatic osteoporotic vertebral compression fractures, characterized by the presence of a dense zone, who underwent percutaneous vertebroplasty (PVP) between January 2021 and December 2021. All patients involved single-level vertebral fractures. There were 19 males and 57 females, aged from 62 to 88 years old, with an average of (68.5±12.5) years old. All patients underwent bilateral transpedicular puncture procedures. Preoperative CT or MRI was utilized to ascertain the relative position of the bone osteodense zone within the vertebral body (specifically, whether this zone is situated in the upper one-third or one-quarter of the left or right sagittal plane). Considering the head and tail regions of the dense zone as puncture targets, the puncture points and paths were meticulously planned, and the working channel was subsequently established. Under continuous monitoring by a C-arm X-ray machine, bone cement was carefully and gradually injected. The operation time, bone cement injection volume, and bone cement leakage were recorded. The visual analogue scale (VAS) and Oswestry disablity index (ODI) were used to evaluate the effectiveness of the operation. ODI and anterior height (AH) of the vertebral body were used to evaluate the efficacy.
RESULTS:
All patients successfully completed the surgery and were followed up for (8.0±1.0) months. The operation time was (36.57±11.25) min, the volume of bone cement injection was(6.07±1.19) ml, and 21 patients of bone cement leakage. There were 3 patients with the VAS exceeded 4 points two days postoperatively, indicating suboptimal pain management. At the three time points of pre-operation, 2 days post-operation and 6 months post-operation, the VAS scores were(7.82±1.29), (2.11±0.44), and (2.04±0.67) respectively;the ODI percentages were(75.65±7.23)%, (29.45±4.16)%, and(28.68±5.62)%;and the AH values were (11.02±1.30), (12.87±3.91), and (12.91±3.86) cm. The differences were all statistically significant(P<0.05). The aforementioned three indices demonstrated significant improvement at both 2 days and 6 months post-operation (all P<0.05). There were no statistically significant differences in these indices between the 2-day and 6-month post-operative periods(P>0.05). The postoperative outcome was satisfactory and durable, with no evidence of vertebral height reduction.
CONCLUSION
Bilateral targeted puncture based on the osteodense dense zone within the vertebral body can achieve bilateral symmetrical and upright full vertebral bone cement reinforcement without increasing bone cement leakage, achieving good early efficacy and preventing late vertebral collapse. This has positive significance for further improving the efficacy of percutaneous vertebroplasty.
Humans
;
Male
;
Female
;
Vertebroplasty/methods*
;
Aged
;
Middle Aged
;
Aged, 80 and over
;
Retrospective Studies
;
Spinal Fractures/surgery*
;
Fractures, Compression/surgery*
;
Punctures
;
Bone Cements
;
Osteoporotic Fractures/surgery*
4.CFD-based performance analysis of flow field-based biosafety high efficiency particulate air filter device
Yan-ju LI ; Ji-xin CUI ; Yun-li BAO ; Xue-long YANG
Chinese Medical Equipment Journal 2025;46(9):22-27
Objective To explore the effects of the disinfection port position and diameter and disinfectant concentration on the in-situ decontamination of the flow field-based biosafety high efficiency particulate air filter device with the computational fluid dynamics(CFD)method.Methods ANSYS DesignModeler was used to construct five models for the high efficiency particulate air filter device with the disinfection port at the side end in four ones and upper end in the remained one model,with the diameter being 70,100,150,260 and 260 mm respectively;secondly,a standard k-ε turbulence model was applied to simulating the velocity field and concentration field inside the high efficiency particulate air filter device,so as to analyze the influence of the vortex position inside the device and the structure of the device on the disinfection effect and to determine the optimal structure of the device;finally,H2O2 with the concentration of 0.45,0.35 or 0.30 mol/L was selected as the disinectant to investigate the effect of the disinfectant concentration on the disinfection under the optimal device structure.Results Simulation showed that there were vortexes existed the cavity between the filter compression structure and the filter of the high efficiency particulate air filter device.The disinfection effect in case of the disinfection port at the side end was higher than that in case of the disinfection port at the upper end;the diameter of the disinfection port had influences on the disinfection effect,and high-concentration disinfectant was found in the device when the diameter was 100 mm.The optimal structure with the disinfection port at the side end and the diameter of 100 mm was determined for the high efficiency particulate air filter device.An increase in H2O2 concentration was beneficial to improve disinfection without corroding and damaging the device when the in-situ decontamination of the flow field-based biosafety high efficiency particulate air filter device was carried out.Conclusion The characteristics of the internal flow field of the flow field-based biosafety high efficiency particulate air filter device and the influencing factors of the in-situ disinfection effect are revealed,and theoretical references are provided for the optimal design of the device.[Chinese Medical Equipment Journal,2025,46(9):22-27]
5.Significance of basophil levels in prognostic evaluation of intra-abdominal infection
Ming-min PANG ; Shao-hua FAN ; Mei-chen YAN ; Bao LIU ; Ju YANG ; Ya-nan LI ; Shi-han ZHANG ; Ting-yu MENG ; Tao GAO
Chinese Journal of Current Advances in General Surgery 2025;28(5):367-372
Objective:To assess the relationship between basophil levels and mortality in patients with intra-abdominal infection.Methods:Information on patients with intraperitoneal infection admitted to the intensive care unit were extracted from the MIMIC database.A time-dependent Cox regression model was used to adjust for confounders associated with 28-day mortality.Propensity score matching(PSM)was used to balance the baseline differences be-tween groups with different basophil levels,and a restricted cube chart(RCS)was used to show the relationship between basophil count and 28-day mortality in patients with intra-abdominal infection.Results:A total of 4403 patients with intra-abdominal infection were enrolled in the MIMIC database.Patients with high basophil levels have lower mortality than those with low basophil levels.There was an L-shaped curve between basophil level and 28-day mortality,with a cut-off value of 0.47×109/L.Cox regression analysis showed that basophil levels were an independent protective factor for mortal-ity in patients with intra-abdominal infection after adjusting for potential confounders(HR=0.586,95%CI:0.443-0.769).Protective factors for death at basophil levels remained after PSM adjusted for potential confounders(HR=0.628,95%CI:0.470-0.832).Conclusion:Basophil level is an independent protective factor for mortality in patients with intra-abdominal infection,and basophil levels should be dynamically monitored to better evaluate the prognosis of patients.
6.Ibuprofen Oral Administration Protocols for Analgesia After Cesarean Delivery: A Prospective Randomized Controlled Study
Shuang LI ; Ju BAO ; Yuan QU ; Bo ZHANG ; Xinni CAO ; Yanping HUANG ; Zhe LIU
Maternal-Fetal Medicine 2025;07(2):69-75
Objective::To compare the analgesic effects of ibuprofen administered orally via two modes combined with a conventional, patient-controlled intravenous analgesia pump on maternal pain after cesarean section (CS).Methods::This prospective, randomized, controlled study enrolled females who underwent CS from August 2022 to August 2023 at Peking University First Hospital, Beijing, China. Participants were randomly assigned to either an as-needed ibuprofen group (300 mg orally upon request) or a scheduled ibuprofen group (300 mg every 12 hours for 48 hours). The primary outcomes assessed were postoperative pain levels using the Wong-Baker Faces Pain Scale-Revised and cumulative oxycodone consumption at multiple time points up to 48 hours post-delivery. Secondary outcomes included recovery parameters (time to first flatus, ambulation, and lactation initiation), patient satisfaction with pain control, and postpartum depression scores evaluated by the Edinburgh Postnatal Depression Scale on postoperative day 3. Normally distributed data analyzed with t-tests; non-normal data with Mann-Whitney U tests; categorical variables with chi-square or Fisher’s exact tests (SPSS 26.0, P < 0.05). Results::After excluding 61 non-eligible cases, 339 patients were included (171 as-needed vs. 168 scheduled). The scheduled group showed significantly better pain control at 12 hours (4.00 (2.00-5.50) vs. 4.00 (4.00-6.00), P < 0.001), 24 hours (4.00 (2.00-4.00) vs. 4.00 (2.00-6.00), P < 0.001), and 36 hours (2.00 (2.00-4.00) vs. 4.00 (2.00-4.00), P < 0.001), and 48 hours (2.00 (2.00-4.00) vs. 2.00 (2.00-4.00), P = 0.004) post-delivery and lower levels of oxycodone consumption at 36 hours (10.20 (8.20-13.35) vs. 11.00 (8.80-14.40), P = 0.042) and 48 hours (12.40 (10.40-15.95) vs. 13.80 (11.00-16.00), P = 0.020) postpartum compared with those in the as-needed group. Additionally, the time to the return of bowel movements was shorter in the scheduled group than in the as-needed group (23.50 (16.94, 31.47) vs. 27.00 (19.88, 35.97), P = 0.004). Differences in post-delivery ambulation, lactation initiation, satisfaction levels, and depression scores were not significantly different between the two groups. Conclusion::The results of this study promote the use of ibuprofen (scheduled oral administration) combined with a conventional, patient-controlled intravenous analgesia pump for achieving better post-CS pain control than an as-needed dosage regimen.Registration::Chinese Clinical Trial Registry, ChiCTR2400082474.
7.CFD-based performance analysis of flow field-based biosafety high efficiency particulate air filter device
Yan-ju LI ; Ji-xin CUI ; Yun-li BAO ; Xue-long YANG
Chinese Medical Equipment Journal 2025;46(9):22-27
Objective To explore the effects of the disinfection port position and diameter and disinfectant concentration on the in-situ decontamination of the flow field-based biosafety high efficiency particulate air filter device with the computational fluid dynamics(CFD)method.Methods ANSYS DesignModeler was used to construct five models for the high efficiency particulate air filter device with the disinfection port at the side end in four ones and upper end in the remained one model,with the diameter being 70,100,150,260 and 260 mm respectively;secondly,a standard k-ε turbulence model was applied to simulating the velocity field and concentration field inside the high efficiency particulate air filter device,so as to analyze the influence of the vortex position inside the device and the structure of the device on the disinfection effect and to determine the optimal structure of the device;finally,H2O2 with the concentration of 0.45,0.35 or 0.30 mol/L was selected as the disinectant to investigate the effect of the disinfectant concentration on the disinfection under the optimal device structure.Results Simulation showed that there were vortexes existed the cavity between the filter compression structure and the filter of the high efficiency particulate air filter device.The disinfection effect in case of the disinfection port at the side end was higher than that in case of the disinfection port at the upper end;the diameter of the disinfection port had influences on the disinfection effect,and high-concentration disinfectant was found in the device when the diameter was 100 mm.The optimal structure with the disinfection port at the side end and the diameter of 100 mm was determined for the high efficiency particulate air filter device.An increase in H2O2 concentration was beneficial to improve disinfection without corroding and damaging the device when the in-situ decontamination of the flow field-based biosafety high efficiency particulate air filter device was carried out.Conclusion The characteristics of the internal flow field of the flow field-based biosafety high efficiency particulate air filter device and the influencing factors of the in-situ disinfection effect are revealed,and theoretical references are provided for the optimal design of the device.[Chinese Medical Equipment Journal,2025,46(9):22-27]
8.Ibuprofen Oral Administration Protocols for Analgesia After Cesarean Delivery: A Prospective Randomized Controlled Study
Shuang LI ; Ju BAO ; Yuan QU ; Bo ZHANG ; Xinni CAO ; Yanping HUANG ; Zhe LIU
Maternal-Fetal Medicine 2025;07(2):69-75
Objective::To compare the analgesic effects of ibuprofen administered orally via two modes combined with a conventional, patient-controlled intravenous analgesia pump on maternal pain after cesarean section (CS).Methods::This prospective, randomized, controlled study enrolled females who underwent CS from August 2022 to August 2023 at Peking University First Hospital, Beijing, China. Participants were randomly assigned to either an as-needed ibuprofen group (300 mg orally upon request) or a scheduled ibuprofen group (300 mg every 12 hours for 48 hours). The primary outcomes assessed were postoperative pain levels using the Wong-Baker Faces Pain Scale-Revised and cumulative oxycodone consumption at multiple time points up to 48 hours post-delivery. Secondary outcomes included recovery parameters (time to first flatus, ambulation, and lactation initiation), patient satisfaction with pain control, and postpartum depression scores evaluated by the Edinburgh Postnatal Depression Scale on postoperative day 3. Normally distributed data analyzed with t-tests; non-normal data with Mann-Whitney U tests; categorical variables with chi-square or Fisher’s exact tests (SPSS 26.0, P < 0.05). Results::After excluding 61 non-eligible cases, 339 patients were included (171 as-needed vs. 168 scheduled). The scheduled group showed significantly better pain control at 12 hours (4.00 (2.00-5.50) vs. 4.00 (4.00-6.00), P < 0.001), 24 hours (4.00 (2.00-4.00) vs. 4.00 (2.00-6.00), P < 0.001), and 36 hours (2.00 (2.00-4.00) vs. 4.00 (2.00-4.00), P < 0.001), and 48 hours (2.00 (2.00-4.00) vs. 2.00 (2.00-4.00), P = 0.004) post-delivery and lower levels of oxycodone consumption at 36 hours (10.20 (8.20-13.35) vs. 11.00 (8.80-14.40), P = 0.042) and 48 hours (12.40 (10.40-15.95) vs. 13.80 (11.00-16.00), P = 0.020) postpartum compared with those in the as-needed group. Additionally, the time to the return of bowel movements was shorter in the scheduled group than in the as-needed group (23.50 (16.94, 31.47) vs. 27.00 (19.88, 35.97), P = 0.004). Differences in post-delivery ambulation, lactation initiation, satisfaction levels, and depression scores were not significantly different between the two groups. Conclusion::The results of this study promote the use of ibuprofen (scheduled oral administration) combined with a conventional, patient-controlled intravenous analgesia pump for achieving better post-CS pain control than an as-needed dosage regimen.Registration::Chinese Clinical Trial Registry, ChiCTR2400082474.
9.Significance of basophil levels in prognostic evaluation of intra-abdominal infection
Ming-min PANG ; Shao-hua FAN ; Mei-chen YAN ; Bao LIU ; Ju YANG ; Ya-nan LI ; Shi-han ZHANG ; Ting-yu MENG ; Tao GAO
Chinese Journal of Current Advances in General Surgery 2025;28(5):367-372
Objective:To assess the relationship between basophil levels and mortality in patients with intra-abdominal infection.Methods:Information on patients with intraperitoneal infection admitted to the intensive care unit were extracted from the MIMIC database.A time-dependent Cox regression model was used to adjust for confounders associated with 28-day mortality.Propensity score matching(PSM)was used to balance the baseline differences be-tween groups with different basophil levels,and a restricted cube chart(RCS)was used to show the relationship between basophil count and 28-day mortality in patients with intra-abdominal infection.Results:A total of 4403 patients with intra-abdominal infection were enrolled in the MIMIC database.Patients with high basophil levels have lower mortality than those with low basophil levels.There was an L-shaped curve between basophil level and 28-day mortality,with a cut-off value of 0.47×109/L.Cox regression analysis showed that basophil levels were an independent protective factor for mortal-ity in patients with intra-abdominal infection after adjusting for potential confounders(HR=0.586,95%CI:0.443-0.769).Protective factors for death at basophil levels remained after PSM adjusted for potential confounders(HR=0.628,95%CI:0.470-0.832).Conclusion:Basophil level is an independent protective factor for mortality in patients with intra-abdominal infection,and basophil levels should be dynamically monitored to better evaluate the prognosis of patients.
10.Surgical strategies for atrial functional mitral regurgitation with atrial fibrillation
Nan MA ; Chunrong BAO ; Ke WEI ; Yunjiao ZHANG ; Li ZHANG ; Ju MEI
Chinese Journal of Thoracic and Cardiovascular Surgery 2024;40(10):607-611
Objective:Analysis of surgical strategies for atrial functional mitral regurgitation with atrial fibrillation.Methods:Retrospective analysis of 112 patients with mitral regurgitation and atrial fibrillation between June 2017 and January 2023. Among them, 56 cases were severe atrial functional mitral regurgitation with atrial fibrillation, and the other 56 cases were degenerative mitral regurgitation with atrial fibrillation. All patients underwent maze Ⅳ procedure and mitral valve surgery. Follow up will be conducted through outpatient follow-up and telephone calls. The condition of postoperative mitral valve is obtained through echo. The postoperative cardiac rhythm is based on the patient's conscious symptoms, electrocardiogram, 24 hour dynamic electrocardiogram.Results:The comparison of preoperative basic data shows that the age, duration of atrial fibrillation, and comorbidity of patients with atrial functional mitral regurgitation are significantly higher than those in the degenerative mitral regurgitation group. All patients successfully completed the surgery. Postoperative death occurred in 2 cases in the atrial mitral regurgitation group. The causes of death were ARDS and pulmonary infection, respectively. The main postoperative complications include bleeding, low cardiac output, pulmonary infection, and acute kidney injury. During follow-up, 43 patients (79.6%) in the atrial mitral regurgitation group maintained sinus rhythm, while 49 patients (87.5%) in the degenerative group. However, there was no statistically significant difference in the Kaplan- Meier curves. In the atrial mitral regurgitation group, there were 47 cases with no mitral regurgitation, 4 cases with mild regurgitation, and 1 case with moderate regurgitation. In the degenerative group, there were 42 cases with no mitral regurgitation, 6 cases with mild regurgitation, 1 case with moderate regurgitation, and 1 case with severe regurgitation. The risk for atrial fibrillation recurrence in the atrial mitral regurgitation is related to postoperative left atrial diameter greater than 50 mm, while in the degenerative group, atrial fibrillation recurrence is related to postoperative left atrial diameter greater than 50 mm and residual mitral regurgitation. Conclusion:Mitral valve repair combined with maze Ⅳ procedure is an effective treatment for patients with severe atrial functional mitral regurgitation and atrial fibrillation. Further improving the success rate of atrial fibrillation and reducing surgical trauma will benefit patients in the future.

Result Analysis
Print
Save
E-mail