1.Necrotizing fasciitis of the face triggered by a neglected hordeolum: a case report and literature review
Soo Hyun WOO ; Su Yong KIM ; Il Young AHN ; Tae Hui BAE ; Shin Hyuk KANG ; Woo Ju KIM ; Han Koo KIM
Archives of Craniofacial Surgery 2026;27(1):34-39
Necrotizing fasciitis (NF) is a rapidly progressive, life-threatening soft tissue infection that rarely involves the periorbital region. We report an unusual case of periorbital NF caused by methicillin-sensitive Staphylococcus aureus (MSSA) in a previously healthy 48-year-old woman, originating from a neglected, recurrent hordeolum—an otherwise benign eyelid condition. The infection resulted in an extensive fullthickness defect of the upper eyelid and adjacent temporal area, presenting major reconstructive challenges. Reconstruction was performed using a radial forearm free flap combined with a buccal mucosal graft to restore both anterior and posterior lamellae, achieving functional eyelid protection and improved visual acuity. This case highlights the potential for seemingly minor, recurrent eyelid infections to progress rapidly to devastating NF even in the absence of systemic symptoms or risk factors. Early recognition and multidisciplinary management were critical to preventing further morbidity. To our knowledge, MSSA has not previously been reported as a causative agent of periorbital NF, underscoring the need for clinical vigilance and timely intervention in common eyelid conditions to avoid catastrophic complications.
2.Effect of 50-Hz Filters on Pattern Electroretinogram
Dong Hee HA ; Nam Ju MOON ; Ungsoo Samuel KIM
Korean Journal of Ophthalmology 2025;39(3):241-245
Purpose:
Pattern electroretinogram (PERG) is used to evaluate the function of retinal ganglion cells. However, the amplitude of PERG is quite small, making the examination challenging to perform. Waveform noise may be minimized by applying various filters. We aimed to investigate the effect of 50-Hz filters on PERG test results.
Methods:
This is the retrospective observational study. PERG tests were performed using the RETI-scan system according to the International Society for Clinical Electrophysiology of Vision guidelines. Three types of 50-Hz filters (soft, middle, and hard) were applied. The differences in parameters (N35 peak time, P50 peak time, N95 peak time, P50 amplitude, N95 amplitude, and N95 to P50 ratio) were analyzed. Based on the provided normal range, the changes from normal to abnormal range or vice versa were investigated.
Results:
A total of 24 waveforms were analyzed. After filtering, the P50 and N95 amplitudes showed a significant reduction of 8% to 15% (P50 amplitude: 5.1 ± 2.7 μV without filter, 4.6 ± 2.3 μV with 50-Hz soft filter, 4.3 ± 2.1 μV with 50-Hz middle filter, 4.3 ± 2.1 μV with 50-Hz hard filter; N95 amplitude: 7.2 ± 4.2 μV without filter, 6.6 ± 3.8 μV with 50-Hz soft filter, 6.3 ± 3.6 μV with 50-Hz middle filter, 6.1 ± 3.6 μV with 50-Hz hard filter). This pattern was more prominent in normal subjects. All latencies except the N35 peak time exhibited no differences between the tests. The N95 to P50 ratio decreased after 50-Hz middle and hard filtering. Considering the normative data, switching between normal and abnormal results was rare.
Conclusions
Although peak time was not significantly affected, amplitude was significantly reduced after using 50-Hz filters. Thus, 50-Hz filters can smoothen the waveform. Nevertheless, caution must be exercised while taking readings.
3.Effect of 50-Hz Filters on Pattern Electroretinogram
Dong Hee HA ; Nam Ju MOON ; Ungsoo Samuel KIM
Korean Journal of Ophthalmology 2025;39(3):241-245
Purpose:
Pattern electroretinogram (PERG) is used to evaluate the function of retinal ganglion cells. However, the amplitude of PERG is quite small, making the examination challenging to perform. Waveform noise may be minimized by applying various filters. We aimed to investigate the effect of 50-Hz filters on PERG test results.
Methods:
This is the retrospective observational study. PERG tests were performed using the RETI-scan system according to the International Society for Clinical Electrophysiology of Vision guidelines. Three types of 50-Hz filters (soft, middle, and hard) were applied. The differences in parameters (N35 peak time, P50 peak time, N95 peak time, P50 amplitude, N95 amplitude, and N95 to P50 ratio) were analyzed. Based on the provided normal range, the changes from normal to abnormal range or vice versa were investigated.
Results:
A total of 24 waveforms were analyzed. After filtering, the P50 and N95 amplitudes showed a significant reduction of 8% to 15% (P50 amplitude: 5.1 ± 2.7 μV without filter, 4.6 ± 2.3 μV with 50-Hz soft filter, 4.3 ± 2.1 μV with 50-Hz middle filter, 4.3 ± 2.1 μV with 50-Hz hard filter; N95 amplitude: 7.2 ± 4.2 μV without filter, 6.6 ± 3.8 μV with 50-Hz soft filter, 6.3 ± 3.6 μV with 50-Hz middle filter, 6.1 ± 3.6 μV with 50-Hz hard filter). This pattern was more prominent in normal subjects. All latencies except the N35 peak time exhibited no differences between the tests. The N95 to P50 ratio decreased after 50-Hz middle and hard filtering. Considering the normative data, switching between normal and abnormal results was rare.
Conclusions
Although peak time was not significantly affected, amplitude was significantly reduced after using 50-Hz filters. Thus, 50-Hz filters can smoothen the waveform. Nevertheless, caution must be exercised while taking readings.
4.Effect of 50-Hz Filters on Pattern Electroretinogram
Dong Hee HA ; Nam Ju MOON ; Ungsoo Samuel KIM
Korean Journal of Ophthalmology 2025;39(3):241-245
Purpose:
Pattern electroretinogram (PERG) is used to evaluate the function of retinal ganglion cells. However, the amplitude of PERG is quite small, making the examination challenging to perform. Waveform noise may be minimized by applying various filters. We aimed to investigate the effect of 50-Hz filters on PERG test results.
Methods:
This is the retrospective observational study. PERG tests were performed using the RETI-scan system according to the International Society for Clinical Electrophysiology of Vision guidelines. Three types of 50-Hz filters (soft, middle, and hard) were applied. The differences in parameters (N35 peak time, P50 peak time, N95 peak time, P50 amplitude, N95 amplitude, and N95 to P50 ratio) were analyzed. Based on the provided normal range, the changes from normal to abnormal range or vice versa were investigated.
Results:
A total of 24 waveforms were analyzed. After filtering, the P50 and N95 amplitudes showed a significant reduction of 8% to 15% (P50 amplitude: 5.1 ± 2.7 μV without filter, 4.6 ± 2.3 μV with 50-Hz soft filter, 4.3 ± 2.1 μV with 50-Hz middle filter, 4.3 ± 2.1 μV with 50-Hz hard filter; N95 amplitude: 7.2 ± 4.2 μV without filter, 6.6 ± 3.8 μV with 50-Hz soft filter, 6.3 ± 3.6 μV with 50-Hz middle filter, 6.1 ± 3.6 μV with 50-Hz hard filter). This pattern was more prominent in normal subjects. All latencies except the N35 peak time exhibited no differences between the tests. The N95 to P50 ratio decreased after 50-Hz middle and hard filtering. Considering the normative data, switching between normal and abnormal results was rare.
Conclusions
Although peak time was not significantly affected, amplitude was significantly reduced after using 50-Hz filters. Thus, 50-Hz filters can smoothen the waveform. Nevertheless, caution must be exercised while taking readings.
5.Effect of 50-Hz Filters on Pattern Electroretinogram
Dong Hee HA ; Nam Ju MOON ; Ungsoo Samuel KIM
Korean Journal of Ophthalmology 2025;39(3):241-245
Purpose:
Pattern electroretinogram (PERG) is used to evaluate the function of retinal ganglion cells. However, the amplitude of PERG is quite small, making the examination challenging to perform. Waveform noise may be minimized by applying various filters. We aimed to investigate the effect of 50-Hz filters on PERG test results.
Methods:
This is the retrospective observational study. PERG tests were performed using the RETI-scan system according to the International Society for Clinical Electrophysiology of Vision guidelines. Three types of 50-Hz filters (soft, middle, and hard) were applied. The differences in parameters (N35 peak time, P50 peak time, N95 peak time, P50 amplitude, N95 amplitude, and N95 to P50 ratio) were analyzed. Based on the provided normal range, the changes from normal to abnormal range or vice versa were investigated.
Results:
A total of 24 waveforms were analyzed. After filtering, the P50 and N95 amplitudes showed a significant reduction of 8% to 15% (P50 amplitude: 5.1 ± 2.7 μV without filter, 4.6 ± 2.3 μV with 50-Hz soft filter, 4.3 ± 2.1 μV with 50-Hz middle filter, 4.3 ± 2.1 μV with 50-Hz hard filter; N95 amplitude: 7.2 ± 4.2 μV without filter, 6.6 ± 3.8 μV with 50-Hz soft filter, 6.3 ± 3.6 μV with 50-Hz middle filter, 6.1 ± 3.6 μV with 50-Hz hard filter). This pattern was more prominent in normal subjects. All latencies except the N35 peak time exhibited no differences between the tests. The N95 to P50 ratio decreased after 50-Hz middle and hard filtering. Considering the normative data, switching between normal and abnormal results was rare.
Conclusions
Although peak time was not significantly affected, amplitude was significantly reduced after using 50-Hz filters. Thus, 50-Hz filters can smoothen the waveform. Nevertheless, caution must be exercised while taking readings.
6.Effect of 50-Hz Filters on Pattern Electroretinogram
Dong Hee HA ; Nam Ju MOON ; Ungsoo Samuel KIM
Korean Journal of Ophthalmology 2025;39(3):241-245
Purpose:
Pattern electroretinogram (PERG) is used to evaluate the function of retinal ganglion cells. However, the amplitude of PERG is quite small, making the examination challenging to perform. Waveform noise may be minimized by applying various filters. We aimed to investigate the effect of 50-Hz filters on PERG test results.
Methods:
This is the retrospective observational study. PERG tests were performed using the RETI-scan system according to the International Society for Clinical Electrophysiology of Vision guidelines. Three types of 50-Hz filters (soft, middle, and hard) were applied. The differences in parameters (N35 peak time, P50 peak time, N95 peak time, P50 amplitude, N95 amplitude, and N95 to P50 ratio) were analyzed. Based on the provided normal range, the changes from normal to abnormal range or vice versa were investigated.
Results:
A total of 24 waveforms were analyzed. After filtering, the P50 and N95 amplitudes showed a significant reduction of 8% to 15% (P50 amplitude: 5.1 ± 2.7 μV without filter, 4.6 ± 2.3 μV with 50-Hz soft filter, 4.3 ± 2.1 μV with 50-Hz middle filter, 4.3 ± 2.1 μV with 50-Hz hard filter; N95 amplitude: 7.2 ± 4.2 μV without filter, 6.6 ± 3.8 μV with 50-Hz soft filter, 6.3 ± 3.6 μV with 50-Hz middle filter, 6.1 ± 3.6 μV with 50-Hz hard filter). This pattern was more prominent in normal subjects. All latencies except the N35 peak time exhibited no differences between the tests. The N95 to P50 ratio decreased after 50-Hz middle and hard filtering. Considering the normative data, switching between normal and abnormal results was rare.
Conclusions
Although peak time was not significantly affected, amplitude was significantly reduced after using 50-Hz filters. Thus, 50-Hz filters can smoothen the waveform. Nevertheless, caution must be exercised while taking readings.
7.Current peritonectomy practice during debulking surgery in patients with newly diagnosed advanced ovarian cancer: a Korean Gynecologic Oncology Group Study (KGOG 4004)
Myeong-Seon KIM ; Yoo-Young LEE ; Soo Jin PARK ; Hee Seung KIM ; Heon Jong YOO ; Myong Cheol LIM ; Yong Jung SONG ; Eun-Ju LEE
Journal of Gynecologic Oncology 2025;36(3):e39-
Objective:
Because of the possible therapeutic benefit of removing occult tumor cells, a source of recurrence and chemoresistance, total parietal peritonectomy (TPP) is an alternative treatment for advanced epithelial ovarian/fallopian tube/primary peritoneal cancer. Interventional studies comparing TPP with selective parietal peritonectomy (SPP) are in progress. Since surgeons skilled in TPP are essential for such trials to be conducted, this nationwide survey aimed to examine current peritonectomy practice among gynecologic oncologists in Korea.
Methods:
A 17-item questionnaire, developed by a surgery committee and reviewed by the scientific review board of the Korean Gynecology Oncology Group (KGOG), was distributed to 144 KGOG members. The questionnaire was divided into 3 categories: respondent demographics, peritonectomy practice during primary debulking surgery (PDS), and peritonectomy practice during interval debulking surgery (IDS).
Results:
We received 88 (61.1%) valid responses. Of the valid respondents, 98.9% and 93.8% performed SPP during PDS and IDS, respectively. Only 4.9% of the respondents performed TPP during IDS. Most respondents performed peritonectomy in cases where optimal postoperative outcomes were expected. Approximately 50.6% of the respondents had performed peritonectomy independently, while the others did so in cooperation with non-gynecologic surgeons. The primary reasons for not performing TPP were concerns about morbidity and uncertainty about the clinical benefits of the procedure.
Conclusion
SPP is the predominant technique used in both PDS and IDS in Korea. A small percentage (4.9%) of gynecologic oncologists have performed TPP during IDS. Accordingly, a study regarding the feasibility of TPP should be conducted before proceeding with a prospective clinical trial.
8.Disproportionality Analysis on Adverse Reactions Following Immune Checkpoint Inhibitors Using a Nationwide Spontaneous Adverse Event Reporting Database
Eunji KIM ; Yu-Seon JUNG ; Jongmin LEE ; Dal Ri NAM ; Seung-Hun YOU ; Ju Won LEE ; Heeyeon LEE ; Su Bin PARK ; Sun-Young JUNG
Korean Journal of Clinical Pharmacy 2025;35(3):187-197
Background:
The use of immune checkpoint inhibitors (ICIs) for advanced cancer is increasing, particularly in combination withchemotherapy. However, previous studies have focused on immune-related adverse events (irAEs) in specific organs, with limited re-search on combination therapy.
Objective:
We aimed to detect signals of adverse drug reaction (ADR) in both ICIs plus chemotherapy and ICIs alone compared to chemotherapy.
Methods:
We investigated individual case safety reports (ICSRs) between 2014 and 2022using Korea Institute of Drug Safety and Risk Management Korean Adverse Event Reporting System database (KIDS KAERS DB(2304A0076)). We defined adverse events (AEs) and drugs using MedDRA and the national drug code directory provided by the Min-istry of Food and Drug Safety. To detect signals, we performed disproportionality analysis using indices of reporting odds ratio (ROR) and information component (IC).
Results:
We identified 206,959 ICSRs in the KIDS KAERS DB, of which 5,154 contained ICIs and 201,805 were for chemotherapy. Compared to chemotherapy, radiation pneumonitis (ROR, 2313.6; IC, 5.4), hyperthyroidism (ROR, 53.4; IC, 4.2), and eczema (ROR,18.3; IC, 3.4) were detected as signals for ICIs. For ICIs with chemotherapy, additional signals including heart failure (ROR 9.65; IC 2.45), proteinuria (ROR 28.67; IC 4.16), and urinary tract infections (ROR 3.46; IC 1.03) were detected.
Conclusion
The study highlights an essential signal of ADRs associated with ICIs, both alone and in combination therapy, with conditions such as hyperthyroidism, hypothyroidism, and pneumonitis. These AEs should be monitored in clinical settings.
9.Clinical Practice Guidelines for Diagnosis and Non-Surgical Treatment of Primary Frozen Shoulder
Byung Chan LEE ; Gi-Wook KIM ; Keewon KIM ; Nackhwan KIM ; Dong Hwan KIM ; Doo Young KIM ; Du Hwan KIM ; Beom Suk KIM ; Seong Hun KIM ; In Jong KIM ; Hyun Jung KIM ; Yoonju NA ; Kyung Eun NAM ; Sung Gyu MOON ; Chang-Won MOON ; Kyunghoon MIN ; Donghwi PARK ; Myung Woo PARK ; Yong Bok PARK ; Jae Hyeon PARK ; Chul-Hyun PARK ; Hyeng-Kyu PARK ; Yunsoo SOH ; Jaeki AHN ; Seoyon YANG ; Kyeong Eun UHM ; Sun Jae WON ; Yu Hui WON ; Dong Hwan YUN ; Yu Sung YOON ; Jin A YOON ; Byeong-Ju LEE ; Woo Hyung LEE ; Yun Jung LEE ; Jae-Hyun LEE ; Jong Hwa LEE ; Yu Jin IM ; Jae-Young LIM ; Min Cheol CHANG ; Sung Joon CHUNG ; Il Young JUNG ; Sungju JEE ; Kyoung Hyo CHOI ; Jong-Moon HWANG ; Jae-Young HAN
Clinical Pain 2025;24(1):1-26
Objective:
Primary frozen shoulder causes significant pain and progressively restricts shoulder movements. Diagnosis is made clinically based on patient history and physical examination. Management is mainly non-invasive owing to its self-limiting clinical course. However, clinical practice guidelines for frozen shoulder have not yet been developed in Korea. The developed guidelines aim to provide evidence-based recommendations for the diagnosis and treatment of frozen shoulder.
Methods:
A guideline development committee reviewed the literature from four databases (PubMed, Embase, Cochrane Library, and KMbase). Using the Population, Intervention, Comparator, and Outcome (PICO) framework, the committee formulated two backgrounds and 16 key questions to address common clinical concerns. Recommendations were made using the Grading of Recommendations, Assessment, Development, and Evaluation framework.
Results:
Diabetes, thyroid disease, and dyslipidemia significantly increase the risk of developing a frozen shoulder. Although frozen shoulder is often self-limiting, some patients may experience long-term functional disabilities. Ultrasound and magnetic resonance imaging should be used as adjunctive tools alongside clinical diagnosis, and rather than as independent diagnostic methods. Noninvasive approaches, such as medications, physical modalities, exercises, electrical stimulation, and manual therapy, may reduce pain and improve shoulder function. Other noninvasive interventions have limited evidence, and their application should be based on clinical judgment. Intra-articular steroid injections are recommended for treatment, and physiotherapy or hydrodilation with steroid injections can also be beneficial.
Conclusion
These guidelines provide evidence-based recommendations for diagnosing and treating primary frozen shoulder.
10.Clinicians’ Knowledge, Attitudes, and Practices Regarding the Management of Functional Gastrointestinal Disorders With Neuromodulators and Psychological Treatment
Seung Yong SHIN ; Ju Yup LEE ; Sung Won JUNG ; Seung-Ho JANG ; Han Seung RYU ; Ayoung LEE ; Geun Tae PARK ; Woongki CHANG ; Minkyong KIM ; Beom Seuk HWANG ; Yong Sung KIM ; Joong Goo KWON
Journal of Neurogastroenterology and Motility 2024;30(4):480-490
Background/Aims:
Little is known about the practical clinical application of neuromodulators and psychiatric treatments in patients with functional gastrointestinal disorders (FGIDs). We investigate the knowledge, attitudes, and practices of Korean clinicians regarding the use of neuromodulators and psychiatric treatments for FGIDs.
Methods:
This prospective, online, cross-sectional study was conducted between May and August 2022. A questionnaire regarding the knowledge, attitude, and practice of neuromodulators and psychiatric treatments for FGIDs was developed and administered to primary care clinicians and gastroenterologists in university hospitals in Korea.
Results:
Overall, 451 clinicians from primary (n = 179, 39.7%), secondary (n = 113, 25.1%), and tertiary (n = 159, 35.3%) hospitals participated in the survey. Most of them considered that neuromodulators (98.7%) and psychiatric treatment (86.5%) were required for patients with FGIDs. However, approximately one-third of them did not prescribe neuromodulators, mainly due to unfamiliarity with the drugs, and only one-quarter considered psychiatric referral. Compared to gastroenterologists at university hospitals, primary care clinicians’ prescriptions had a lower rate (87.2% vs 64.2%, P < 0.001) and shorter duration of neuromodulator. The psychiatric referral rate was lower for primary care clinicians than for gastroenterologists at university hospitals (19.0% vs 34.2%, P < 0.001).
Conclusions
Knowledge, attitude, and practice levels regarding neuromodulators and psychiatric treatment among clinicians are inhomogeneous, and a knowledge gap exists between primary care clinicians and gastroenterologists at university hospitals. Encouraging ongoing education for Korean clinicians regarding the appropriate use of neuromodulators and psychiatric treatments in patients with FGIDs is suggested.

Result Analysis
Print
Save
E-mail