1.Relevance of intra-abdominal pressure monitoring in non-operative management of patients with blunt liver and splenic injuries.
Vivek KUMAR ; Ramesh VAIDYANATHAN ; Dinesh BAGARIA ; Pratyusha PRIYADARSHINI ; Abhinav KUMAR ; Narendra CHOUDHARY ; Sushma SAGAR ; Amit GUPTA ; Biplab MISHRA ; Mohit JOSHI ; Kapil Dev SONI ; Richa AGGARWAL ; Subodh KUMAR
Chinese Journal of Traumatology 2025;28(4):307-312
PURPOSE:
Non-operative management (NOM) has been validated for blunt liver and splenic injuries. Literature on continuous intra-abdominal pressure (IAP) monitoring as a part of NOM remains to be equivocal. The study aimed to find any correlation between clinical parameters and IAP, and their effect on the NOM of patients with blunt liver and splenic injury.
METHOD:
A prospective cross-sectional study conducted at a level I trauma center from October 2018 to January 2020 including 174 patients who underwent NOM following blunt liver and splenic injuries. Hemodynamically unstable patients or those on ventilators were excluded, as well as patients who suffered significant head, spinal cord, and/or bladder injuries. The study predominantly included males (83.9%) with a mean age of 32.5 years. IAP was monitored continuously and the relation of IAP with various parameters, interventions, and outcomes were measured. Data were summarized as frequency (percentage) or mean ± SD or median (Q1, Q3) as indicated. χ2 or Fisher's exact test was used for categorical variables, while for continuous variables parametric (independent t-test) or nonparametric tests (Wilcoxon rank sum test) were used as appropriate. Clinical and laboratory correlates of IAP < 12 with p < 0.200 in the univariable logistic regression analysis were included in the multivariable analysis. A p < 0.05 was used to indicate statistical significance.
RESULTS:
Intra-abdominal hypertension (IAH) was seen in 19.0% of the study population. IAH was strongly associated with a high injury severity score (p < 0.001), and other physiological parameters like respiratory rate (p < 0.001), change in abdominal girth (AG) (p < 0.001), and serum creatinine (p < 0.001). IAH along with the number of solid organs involved, respiratory rate, change in AG, and serum creatinine was associated with the intervention, either operative or non-operative (p = 0.001, p = 0.002, p < 0.001, p < 0.001, p = 0.013, respectively). On multivariable analysis, IAP (p = 0.006) and the mean change of AG (p = 0.004) were significantly associated with the need for intervention.
CONCLUSION
As a part of NOM, IAP should be monitored as a continuous vital. However, the decision for any intervention, either operative or non-operative cannot be guided by IAP values alone.
Humans
;
Male
;
Adult
;
Female
;
Wounds, Nonpenetrating/physiopathology*
;
Spleen/injuries*
;
Prospective Studies
;
Cross-Sectional Studies
;
Liver/injuries*
;
Middle Aged
;
Monitoring, Physiologic/methods*
;
Pressure
;
Abdominal Injuries/physiopathology*
;
Intra-Abdominal Hypertension
;
Young Adult
2.Comparative prospective study between medial and lateral distal tibial locking compression plates for distal third tibial fractures.
Sandeep GARG ; Vikram KHANNA ; Mahaveer Prashad GOYAL ; Narendra JOSHI ; Amrut BORADE ; Ishan GHUSE
Chinese Journal of Traumatology 2017;20(3):151-154
PURPOSETibial fracture is the most common long bone fracture. Distal third tibial fractures are challenging though open reduction and plating can result in anatomical reduction and rigid fixation. This paper aimed to evaluate and compare the results of medial and lateral locking compression plates for distal third tibial fractures.
METHODSThis prospective clinical study involved 36 patients with distal tibial fractures admitted in Department of Orthopaedics, Sawai Mansingh Medical College & Affiliated Hospital, Jaipur, India, from June 2011 to May 2012, including 29 closed fractures and 7 open fractures at the mean age of 38.9 years. Thirty-six patients were divided equally into two groups based on treatment method, including medial plating group (18 patients) and lateral plating group (18 patients). They were followed up for at least 5 months after discharge. The functional outcomes were evaluated using Tenny and Wiss clinical assessment criteria.
RESULTSMalunion was found in 3 cases of medial plating group and in 1 case of lateral plating group. In the medial plating group, there were 5 cases of superficial infections, 1 deep infection, 1 nonunion and 3 wound dehiscence. In the lateral plating group, there was 1 case of superficial infections, 1 deep infection and 1 nonunion. In the lateral plating group, 4 patients reported feeling the plates and screws but none of them asked to remove the hardware. In the medial plating group, 9 patients reported symptomatic hardware problems and 7 asked to remove the hardware. The number of cases graded as excellent/good/fair was 1/8/7 in the medial plating group and 3/7/7 in the lateral plating group respectively. In the medial plating group, the final range of motion was 17.2° in ankle dorsiflexion and 30.7° in ankle plantar flexion. In the lateral plating group, the final range of motion was 19° in ankle dorsiflexion and 34.2° in ankle plantar flexion.
CONCLUSIONLateral plating of distal tibia is safe and feasible, which can provide biological fixation and prevent the soft tissue complications associated with medial plating.
3.A bony foreign body found in a patient with no bony injury: a case report.
Devwart KAUSHIK ; Narendra JOSHI ; Rakesh KUMAR ; Shiv Kumar GOYAL ; Kamlesh KUMAR ; Sahil GABA
Chinese Journal of Traumatology 2014;17(6):367-369
Open fractures with bone loss are a common occurrence following high energy trauma. But usually the bone fragments are lost on the roadside and are not usable. We report a patient who was involved in a head-on collision between two wheelers and presented with a bone fragment embedded in his thigh. Radiological survey revealed no bony injury in that patient. Another patient, who presented at the same time, sustained a segmental fracture of shaft femur and was found to have lost a bone fragment that was similar to the one found in previous patient. CT scan with 3D reconstruction revealed this missing fragment to be the same as that found in previous patient. Both patients had a history of head-on collision while travelling on a two-wheeler. Present case report throws some highlights on the probable mechanism of injury.
Accidents, Traffic
;
Bone and Bones
;
injuries
;
Foreign Bodies
;
Thigh
;
injuries
4.A bony foreign body found in a patient with no bony injury:a case report
Kaushik DEVWART ; Joshi NARENDRA ; Kumar RAKESH ; Goyal Kumar SHIV ; Kumar KAMLESH ; Gaba SAHIL
Chinese Journal of Traumatology 2014;(6):367-369
Open fractures with bone loss are a common occurrence following high energy trauma. But usually the bone fragments are lost on the roadside and are not usable. We report a patient who was involved in a head-on collision between two wheelers and presented with a bone fragment embedded in his thigh. Radiological survey revealed no bony injury in that patient. Another patient, who presented at the same time, sustained a segmental fracture of shaft femur and was found to have lost a bone fragment that was similar to the one found in previous patient. CT scan with 3D reconstruction revealed this missing fragment to be the same as that found in previous patient. Both patients had a history of head-on collision while travelling on a two-wheeler. Present case report throws some highlights on the probable mechanism of injury.

Result Analysis
Print
Save
E-mail