1.Development of an Instrument for Slit-lamp Examination of Donor Corneas in Preservation Medium
Ga Hee NAM ; Da Ran KIM ; Young Chae YOON ; Soon Won YANG ; Woong Joo WHANG ; Yong-Soo BYUN ; Hyung Bin HWANG ; Kyung Sun NA ; Hyun Soo LEE ; So Hyang CHUNG ; Eun Chul KIM ; Yang Kyung CHO ; Hyun Seung KIM ; Ho Sik HWANG
Journal of the Korean Ophthalmological Society 2024;65(2):108-116
Purpose:
To evaluate the effectiveness of an instrument devised for slit-lamp examination of donor corneas suspended in preservation medium.
Methods:
The study examined two donor corneas received at Yeouido St. Mary's Hospital in February 2023 and March 2023. The instrument has three main components: a plastic holder to hold the preservation medium bottle, a cube with a mirror for reflecting the slit beam, and a stand to attach the device to the slit-lamp. Using the instrument, the donor corneas were examined via slit-lamp: microscopy with the endothelium facing upward and downward. Specular microscopy and anterior segment optical coherence tomography (OCT) were also performed on the preserved donor corneas.
Results:
Slit-lamp examination of donor corneas in preservation medium using the instrument showed overall corneal buttoning and optical sections of the donor cornea. Using specular reflection and retroillumination, the endothelial layer was partially visible. However, specular microscopy and anterior segment OCT could not examine the donor cornea in preservation medium using the instrument.
Conclusions
The devised instrument facilitates slit-lamp examination of donor corneas in preservation medium, enabling a qualitative assessment of donor corneas before corneal transplantation surgery.
2.Categorization of Meibomian Gland Dysfunction Using Lipid Layer Thickness and Meibomian Gland Dropout in Dry Eye Patients: A Retrospective Study
Phil Kyu LEE ; Jae Lim CHUNG ; Da Ran KIM ; Young Chae YOON ; SoonWon YANG ; Woong-Joo WHANG ; Yong-Soo BYUN ; HyungBin HWANG ; Kyung Sun NA ; HyunSoo LEE ; So Hyang CHUNG ; Eun Chul KIM ; YangKyung CHO ; Hyun Seung KIM ; Ho Sik HWANG
Korean Journal of Ophthalmology 2024;38(1):64-70
Purpose:
In the present study, we determined the prevalence of obstructive meibomian gland dysfunction (MGD), hyposecretory MGD, grossly normal MG, and hypersecretory MGD in patients with dry eye syndrome using lipid layer thickness (LLT) and MG dropout.
Methods:
Eighty-eight patients with dry eye syndrome were included in the study. Patients were categorized into four groups according to the LLT and weighted total meiboscore. The proportion of patients in each group was calculated. The age, sex, Ocular Surface Disease Index, LLT, Schirmer, tear film breakup time, cornea stain, weighted total meiboscore, expressibility, and quality of meibum were compared between the four groups.
Results:
Fifteen eyes (17.0%) had obstructive MGD, two eyes (2.3%) had hyposecretory MGD, 40 eyes (45.5%) had grossly normal MG, and 17 eyes (19.3%) had hypersecretory MGD. The obstructive MGD group was younger than the grossly normal MG group. In obstructive MGD, the ratio of men to women was higher than that of the other groups. However, Ocular Surface Disease Index, Schirmer, tear film breakup time, and corneal stain did not show statistically significant differences between the four groups. The meibum expressibility of the hyposecretoy MGD group was worse than those of the other groups. The meibum expressibility of the hyposecretoy MGD group was poor than those of the obstructive and hypersecretory MGD group.
Conclusions
This categorization was expected to help determine the best treatment method for dry eye syndrome, according to the MG status.
3.In Vivo Human Lacrimal Gland Imaging Using an Ultrasound Biomicroscopy
Chanjoon PARK ; Da Ran KIM ; Young Chae YOON ; Soonwon YANG ; Woong-Joo WHANG ; Yong-Soo BYUN ; Hyung Bin HWANG ; Kyung Sun NA ; Hyun Soo LEE ; So Hyang CHUNG ; Eun Chul KIM ; Yang Kyung CHO ; Hyun Seung KIM ; Hosik HWANG
Korean Journal of Ophthalmology 2024;38(3):227-235
Purpose:
In the present study, we introduce human lacrimal gland imaging using an ultrasound biomicroscopy (UBM) with a soft cover and show their findings
Methods:
The representative UBM findings of palpebral lobes in seven subjects (four with non-Sjögren dry eye syndrome, one with Sjögren syndrome, and two healthy subjects) were described in this study. To prolapse the palpebral lobe, the examiner pulled the temporal part of the upper eyelid in the superotemporal direction and directed the subject to look in the inferonasal direction. We scanned the palpebral lobes longitudinally and transversely using UBM. We used an Aviso UBM with a 50 MHz linear probe and ClearScan.
Results:
In UBM of two healthy subjects, the echogenicity of the lacrimal gland was lower than that of the sclera and homogeneous. But the parenchyma of a patient with Sjögren dry eye syndrome was quite inhomogeneous compared to the healthy subjects. In two patients with dry eye syndrome, we were able to observe some lobules in the parenchyma. We could find excretory ducts running parallel at the surface of the longitudinal section in some subjects. In the longitudinal UBM scan of a subject, we observed a tubular structure at a depth of 1,500 μm that was considered a blood vessel. It ran from the superonasal to the inferotemporal direction. In a subject, we observed a large cyst beneath the conjunctiva.
Conclusions
Lacrimal gland imaging using UBM has both advantages of optical coherence tomography and sonography, and could be useful for evaluating dry eye syndrome.
4.Trends in Corneal Transplantation Revealed by KONOS and Health Insurance Review and Assessment Service Annual Reports
Jiyoung LEE ; Sun Young LEE ; Young Chae YOON ; Sun Kyoung PARK ; Woong-Joo WHANG ; Yong Soo BYUN ; Hyung Bin HWANG ; Kyung Sun NA ; Hyun Soo LEE ; So Hyang CHUNG ; Eun Chul KIM ; Yang Kyung CHO ; Hyun Seung KIM ; Ho Sik HWANG
Journal of the Korean Ophthalmological Society 2023;64(4):273-280
Purpose:
To analyze trends in corneal transplantation surgery and determine the number of domestic and imported corneal grafts used in South Korea.Method: The total number of keratoplasties and number of each individual surgical procedure conducted in 2010 and 2020 were identified using Health Insurance Review and Assessment Service data. The number of keratoplasties using domestic corneas in 2010 and 2020 was determined from the annual report of the Korean Network for Organ Sharing (KONOS). The number of keratoplasties using imported corneas was calculated by subtracting the number of keratoplasties using domestic corneas from the total number of keratoplasties.
Results:
In 2010, 802 keratoplasties were performed in Korea, of which 299 (37.3%) used imported corneas; 715 (89.2%) were penetrating keratoplasties and 87 (10.8%) were anterior lamellar keratoplasties. In 2020, 911 keratoplasties were done in Korea and 564 (61.9%) used imported corneas; 541 (59.4%) were penetrating keratoplasties, 60 (6.6%) were anterior lamellar keratoplasties, and 310 (34.0%) were endothelial keratoplasties. From 2010 to 2020, the number of penetrating keratoplasties in Korea decreased, while the numbers of endothelial keratoplasties and keratoplasties using imported corneas increased.
Conclusions
There was a 30% decrease in the number of penetrating keratoplasties from 2010 to 2020, and a 30% increase in the numbers of endothelial keratoplasties and keratoplasties using imported corneas. The proportions of endothelial keratoplasties and imported corneas have increased steadily in Korea over the last 10 years.
6.Novel Method Measuring Conjunctival Microvascular Blood Flow Velocity by Zoom-lens, Ultra-high-speed Camera Attached Slit-lamp Biomicroscope
Hyo Sin KIM ; Da Ran KIM ; Young Chae YOON ; Soon Won YANG ; Young Sik YOO ; Woong Joo WHANG ; Yong-Soo BYUN ; Hyung Bin HWANG ; Kyung Sun NA ; Hyun Soo LEE ; So Hyang CHUNG ; Eun Chul KIM ; Yang Kyung CHO ; Hyun Seung KIM ; Ho Sik HWANG
Journal of the Korean Ophthalmological Society 2023;64(11):1001-1008
Purpose:
To introduce an intuitive method for measuring conjunctival microvascular blood flow velocity by imaging bulbar conjunctival microvessels using a slit-lamp biomicroscope equipped with a zoom lens and an ultra-high-speed camera.
Methods:
After obtaining consent from 10 patients (1 male, 9 females) who visited Yeouido St. Mary’s Hospital from August 21, 2020, to June 12, 2021, the patients were examined under a slit lamp microscope equipped with an ultra-high-speed camera and zoom lens. The blood flow in the conjunctival microvessels was photographed. The captured images were analyzed with ImageJ software to measure the blood flow velocity in the conjunctival microvessels, and we investigated whether the blood flow velocity correlated with the vessel diameter and age.
Results:
The median age of the subjects was 49.0 years. The mean conjunctival blood flow velocity in 53 microvessels was 0.786 ± 0.468 mm/s. The median conjunctival microvascular diameter was 7.06 μm (interquartile range 5.84 to 9.23 μm). The conjunctival microvascular diameter and blood flow velocity were not significantly correlated (Spearman’s p = 0.177), and the subjects’ age and conjunctival microvascular blood flow velocity were also not correlated (Spearman’s p = 0.669).
Conclusions
In this study, the blood flow velocity in the bulbar conjunctival microvessels could be measured easily by means of image analysis using a slit-lamp microscope equipped with an ultra-high-speed camera with a zoom lens.
7.Impacts of muscle mass dynamics on prognosis of outpatients with cirrhosis
Tae Hyung KIM ; Young Kul JUNG ; Hyung Joon YIM ; Joo Won BAIK ; Sun Young YIM ; Young-Sun LEE ; Yeon Seok SEO ; Ji Hoon KIM ; Jong Eun YEON ; Kwan Soo BYUN
Clinical and Molecular Hepatology 2022;28(4):876-889
Background/Aims:
Sarcopenia negatively affects the prognosis of cirrhotic patients, but clinical implications of changes in muscle mass remain unclear. We aimed to elucidate its role in the prognosis of outpatients with cirrhosis.
Methods:
Patients with cirrhosis who underwent annual abdominal computed tomography (CT) for hepatocellular carcinoma surveillance were included in the prospective cohort. The L3 skeletal muscle index (SMI) was adopted as a proxy for the amount of skeletal muscle, and the rate of SMI change between inclusion and after 1 year (ΔSMI/yr%) was calculated.
Results:
In total, 595 patients underwent a second CT after 1 year. Among them, 109 and 64 patients had sarcopenia and Child-Pugh class B/C decompensation at inclusion, which changed to 103 and 45 at the 1-year follow-up, respectively. During a median follow-up of 30.1 months after 1 year, 86 patients had at least one cirrhosis complication, and 18 died or received liver transplantation. In the development of cirrhosis complications, ΔSMI/yr% was independently associated, even after adjusting for the Child-Pugh and model for end stage liver disease (MELD)-Na scores. In addition, ΔSMI/yr% showed a good predictive performance for the development of cirrhosis complications within 6 months after 1-year follow-up in all subgroups, with a cut-off of -2.62 (sensitivity, 83.9%; specificity, 74.5%) in the overall population. SMI at 1-year and Child-Pugh score were independent factors associated with survival. In addition, changes in sarcopenia status significantly stratified survival.
Conclusion
ΔSMI/yr% was a good predictor of the development of cirrhosis complications in outpatients with cirrhosis, independent of Child-Pugh and MELD scores.
8.Comparison of the Optimized Intraocular Lens Constants Calculated by Automated and Manifest Refraction for Korean
Youngsub EOM ; Dong Hui LIM ; Dong Hyun KIM ; Yong-Soo BYUN ; Kyung Sun NA ; Seong-Jae KIM ; Chang Rae RHO ; So-Hyang CHUNG ; Ji Eun LEE ; Kyong Jin CHO ; Tae-Young CHUNG ; Eun Chul KIM ; Young Joo SHIN ; Sang-Mok LEE ; Yang Kyung CHO ; Kyung Chul YOON ; In-Cheon YOU ; Byung Yi KO ; Hong Kyun KIM ; Jong Suk SONG ; Do Hyung LEE
Journal of the Korean Ophthalmological Society 2022;63(9):747-753
Purpose:
To derive the optimized intraocular lens (IOL) constants from automated and manifest refraction after cataract surgery in Korean patients, and to evaluate whether there is a difference in optimized IOL constants according to the refraction method.
Methods:
This retrospective multicenter cohort study enrolled 4,103 eyes of 4,103 patients who underwent phacoemulsification and in-the-bag IOL implantation at 18 institutes. Optimized IOL constants for the SRK/T, Holladay, Hoffer Q, and Haigis formulas were calculated via autorefraction or manifest refraction of samples using the same biometry and IOL. The IOL constants derived from autorefraction and manifest refraction were compared.
Results:
Of the 4,103 eyes, the majority (62.9%) were measured with an IOLMaster 500 followed by an IOLMaster 700 (15.2%). A total of 33 types of IOLs were used, and the Tecnis ZCB00 was the most frequently used (53.0%). There was no statistically significant difference in IOL constants derived from autorefraction and manifest refraction when IOL constants were optimized with a large number of study subjects. On the other hand, optimized IOL constants derived from autorefraction were significantly smaller than those from manifest refraction when the number of subjects was small.
Conclusions
It became possible to use the IOL constants optimized from Koreans to calculate the IOL power. However, if the IOL constant is optimized using autorefraction in a small sample group, the IOL constant tends to be small, which may lead to refractive error after surgery.
9.Serum milk fat globule-EGF factor 8 protein as a potential biomarker for metabolic syndrome
Han Ah LEE ; Jihwan LIM ; Hyung Joon JOO ; Young-Sun LEE ; Young Kul JUNG ; Ji Hoon KIM ; Hyunggin AN ; Hyung Joon YIM ; Yoon Tae JEEN ; Jong Eun YEON ; Do-Sun LIM ; Kwan Soo BYUN ; Yeon Seok SEO
Clinical and Molecular Hepatology 2021;27(3):463-473
Background/Aims:
Useful biomarkers for metabolic syndrome have been insufficient. We investigated the performance of serum milk fat globule-EGF factor-8 (MFG-E8), the key mediator of inflammatory pathway, in diagnosis of metabolic syndrome.
Methods:
Subjects aged between 30 and 64 years were prospectively enrolled in the Seoul Metabolic Syndrome cohort. Serum MFG-E8 levels were measured at baseline.
Results:
A total of 556 subjects were included, comprising 279 women (50.2%) and 277 men (49.8%). Metabolic syndrome was diagnosed in 236 subjects (42.4%), and the mean MFG-E8 level of subjects with metabolic syndrome was significantly higher than that of subjects without metabolic syndrome (P<0.001). MFG-E8 level was significantly correlated with all metabolic syndrome components and pulse wave velocity (all P<0.05). Subjects were categorized into two groups according to the best MFG-E8 cut-off value as follows: group 1, MFG-E8 level <4,745.1 pg/mL (n=401, 72.1%); and group 2, MFG-E8 level ≥4,745.1 (n=155, 27.9%). At baseline, metabolic syndrome in group 2 was significantly more prevalent than in group 1 (63.9% vs. 34.2%, P<0.001). During median follow-up of 17 months, metabolic syndrome developed in 122 (38.1%) subjects among 320 subjects without it at baseline. The incidence of metabolic syndrome in group 2 was significantly higher than that in group 1 (55.4% vs. 34.5%, P=0.003). On multivariate analysis, MFG-E8 level ≥4,745.1 pg/mL was an independent predictor for diagnosis and development of metabolic syndrome after adjusting other factors (all P<0.05).
Conclusions
Serum MFG-E8 level is a potent biomarker for the screening and prediction of metabolic syndrome.
10.Descemet Membrane Endothelial Keratoplasty after Penetrating Keratoplasty Graft Failure
Woo Young SON ; Min Ji HA ; Woong Joo WHANG ; Yong-Soo BYUN ; Hyung Bin HWANG ; Kyung Sun NA ; Chang Rae RHO ; Hyun Soo LEE ; So Hyang CHUNG ; Eun Chul KIM ; Yang Kyung CHO ; Hyun Seung KIM ; Ho Sik HWANG
Journal of the Korean Ophthalmological Society 2021;62(6):848-854
Purpose:
To report a case of a successful secondary Descemet membrane endothelial keratoplasty in failed penetrating keratoplasty. Case summary: A 46-year-old male with keratoconus in both of his eyes underwent penetrating keratoplasty in his right eye 30 years ago and in his left eye 14 years ago. From one and a half year ago, the patient’s visual acuity decreased in his left eye due to graft failure. For treatment, secondary Descemet membrane endothelial keratoplasty was performed. Partial detachment of Descemet membrane was observed at 13 days after the operation, and an additional air injection was performed. At 8 months after the operation, the patient’s uncorrected visual acuity improved to 0.5 and the cornea maintained its clearance without rejection.
Conclusions
Secondary Descemet membrane endothelial keratoplasty was successfully performed in a patient with failed penetrating keratoplasty.

Result Analysis
Print
Save
E-mail