1.Guided endodontic microsurgery using a simplified surgical guide for mandibular first molars with intact buccal cortical bone
Oral Biology Research 2026;50(1):3-
Endodontic microsurgery in mandibular molars is often challenging because of limited surgical access and the presence of thick buccal cortical bone. This case report presents two cases in which a simplified digital surgical guide was used to facilitate precise osteotomy and localization of the root apex in mandibular molars with intact buccal cortical bone. Both patients presented with symptomatic apical periodontitis associated with previously treated mandibular first molars. Radiographic and cone-beam computed tomography (CBCT) examinations identified periapical lesions involving the mesial roots, with intact buccal cortical plate. A surgical guide was digitally designed by integrating intraoral scan data with CBCT images using implant planning software and was fabricated via 3D printing. The guide enabled accurate determination of the initial osteotomy position. Guided osteotomy allowed precise localization of the root apex with minimal bone removal, and both cases demonstrated favorable clinical and radiographic healing during follow-up.
2.Dietary management of pediatric patients with kidney disease: recommendations by the Korean Society of Pediatric Nephrology and the Korean Society of Clinical Nutrition
Yo Han AHN ; Hee Gyung KANG ; Jiyoung SONG ; Sangmi HAN ; Eujin PARK ; Jin-Soon SUH ; Jeong Yeon KIM ; Min Ji PARK ; Keum Hwa LEE ; Seon Hee LIM ; Kyeong Hun SHIN ; Hyunji KO ; Hyun Joo LEE ; Eunyoung JEONG ; Jinsu KIM ; Sohyun PARK ; Eonju CHOI ; Yuri SEO ; Kyooyung OH ; Jin Kyoung KIM ; Hyun Kyung LEE
Childhood Kidney Diseases 2026;30(1):4-14
Pediatric kidney disease has a relatively lower prevalence than do other pediatric conditions and has a notably different etiology from kidney diseases observed in adults. Furthermore, the pediatric population is unique in that they experience ongoing growth and development, distinguishing them from adult patients. Consequently, pediatric patients with kidney disease require more specialized and meticulous nutritional management than do adults. To address this need and promote optimal dietary practices for pediatric patients with kidney disease, pediatric nephrologists from the Korean Society of Pediatric Nephrology and nutritionists from the Korean Society of Clinical Nutrition have collaborated to establish nutritional guidelines specifically tailored to Korean dietary patterns. These guidelines offer detailed, nutrient-specific recommendations covering energy, protein, calcium, phosphorus, and potassium consumption while providing practical, culturally relevant guidance intended to support both pediatric patients and their caregivers.
3.The Korean Rectal Cancer Multidisciplinary Committee Clinical Practice Guidelines for Rectal Cancer version 2.0
Hyo Seon RYU ; Hyun Jung KIM ; Dong Hyun KANG ; Yoo-Kang KWAK ; Han Deok KWAK ; Yoon-Hye KWON ; Dalyon KIM ; Baek-Hui KIM ; Jae Hyun KIM ; Ji Hun KIM ; Jin Won KIM ; Tae Hyung KIM ; Hae Young KIM ; Soo Min NAM ; Gyoung Tae NOH ; Jun Woo BONG ; Nak Song SUNG ; Seon Hui SHIN ; Kil-Yong LEE ; Sung Chul LEE ; Sea-Won LEE ; Jung Won LEE ; Jong Min LEE ; Myung Hoon IHN ; Joo Han LIM ; Woong Bae JI ; Dae Hee PYO ; Young Ki HONG ; Jung-Myun KWAK ;
Annals of Coloproctology 2026;42(1):4-33
Rectal cancer, which accounts for approximately 40% of colorectal cancers, remains a major clinical concern. Recent advances in diagnostic imaging, surgical techniques, radiotherapy, and systemic treatment have steadily improved rectal cancer outcomes. Considering this, the Korean Rectal Cancer Multidisciplinary (KRCM) Committee has aimed to provide clinicians and policymakers with up-to-date, evidence-based clinical practice guidelines to support optimal decision-making, reflecting current evidence, the Korean healthcare context, and patient values and preferences. The Clinical Practice Guidelines for Rectal Cancer version 2.0 were developed through multidisciplinary collaboration with related academic societies, building upon and updating the KRCM Clinical Practice Guidelines version 1.0 (titled “Multidisciplinary guidelines for the management of rectal cancer”). These consensus guidelines of the KRCM were established based on a comprehensive literature review, evidence synthesis, with recommendation development guided by the GRADE (Grading of Recommendations Assessment, Development and Evaluation) methodology, and consideration of applicability in real-world clinical practice under the national health insurance system. Each recommendation has been presented with its strength and level of evidence.
4.Comparison of intraoral scan precision according to surface roughness of the prepared abutment models
Dong-Joon SONG ; Hee-Jung KIM ; Joo-Hun SONG
The Journal of Korean Academy of Prosthodontics 2026;64(1):15-26
Purpose:
The purpose of this study was to determine scanning accuracy (precision) of an intraoral scanner according to surface roughness of the prepared abutment models and to identify the most advantageous tooth surface roughness for scanning.
Materials and methods:
Using Computer-Aided Design (CAD) software (Autodesk Meshmixer), four maxillary molar abutment models were designed to fit the maxillary dentiform and printed with Polymethylmethacrylate (PMMA) (MAZIC D temp) using a 3D printer (Carima IMD). The teeth were fixed to the dentiform. Each model was prepared with four diamond burs of different grit sizes:Coarse (125 – 150 µm), Medium (106 – 125 µm), Fine (53 – 63 µm), and Extra-fine (20 – 30 µm), producing four abutment groups (group G, B, R, Y). Each model was scanned twice with an intraoral scanner (Primescan), generating paired scan files that were overlapped and aligned. This was repeated ten times, yielding 20 files (10 pairs) per model. The precision of the 10 pairs was evaluated with 3D analysis software (GOM Inspect 2018). A point guide created with Autodesk Meshmixer was used to analyze deviations at 14 fixed points. The analysis was conducted from three perspectives: First, whether precision differed as surface roughness changed; second, whether there was a difference in precision between the seven upper and seven lower points in each model; third, whether the presence and direction of adjacent teeth influenced precision, assessed by deviations at mesial, distal, buccal, and palatal points. Differences in mean deviations among the groups and the directions were statistically analyzed using ANOVA (α = 0.05), and the differences between the upper and lower points were analyzed using an independent samples T-test (α = 0.05).
Results:
Deviations according to abutment surface roughness were lowest in group Y, followed by R, B, and G (P < .05). No statistical significance was observed between the seven upper and seven lower points in groups G, B, R, and Y (P > .05). To determine differences in scan precision by directions, points on the same horizontal plane were grouped, and mean deviations among the seven groups were compared. No statistical significance was found (P> .05).
Conclusion
When preparing an abutment for prosthesis restoration, the consistency and precision of intraoral scan improve as the surface roughness decreases and angled areas are finished smoothly. In addition, if a skilled operator performs the intraoral scan consistently, there is no significant difference in scan precision according to the location of the scanned point.
5.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
6.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
7.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
8.Dietary management of pediatric patients with kidney disease: recommendations by The Korean Society of Pediatric Nephrology and The Korean Society of Clinical Nutrition
Yo Han AHN ; Hee Gyung KANG ; Jiyoung SONG ; Sangmi HAN ; Eujin PARK ; Jin-Soon SUH ; Jeong Yeon KIM ; Min Ji PARK ; Keum Hwa LEE ; Seon Hee LIM ; Kyeong Hun SHIN ; Hyunji KO ; Hyun Joo LEE ; Eunyoung JEONG ; Jinsu KIM ; Sohyun PARK ; Eonju CHOI ; Yuri SEO ; Kyooyung OH ; Jin Kyoung KIM ; Hyun Kyung LEE
Kidney Research and Clinical Practice 2025;44(6):863-874
Pediatric kidney disease has a relatively lower prevalence than do other pediatric conditions and has a notably different etiology from kidney diseases observed in adults. Furthermore, the pediatric population is unique in that they experience ongoing growth and development, distinguishing them from adult patients. Consequently, pediatric patients with kidney disease require more specialized and meticulous nutritional management than do adults. To address this need and promote optimal dietary practices for pediatric patients with kidney disease, pediatric nephrologists from the Korean Society of Pediatric Nephrology and nutritionists from the Korean Society of Clinical Nutrition have collaborated to establish nutritional guidelines specifically tailored to Korean dietary patterns. These guidelines offer detailed, nutrient-specific recommendations covering energy, protein, calcium, phosphorus, and potassium consumption while providing practical, culturally relevant guidance intended to support both pediatric patients and their caregivers.
9.Correction: 2023 Korean Society of Echocardiography position paper for diagnosis and management of valvular heart disease, part I: aortic valve disease
Sun Hwa LEE ; Se Jung YOON ; Byung Joo SUN ; Hyue Mee KIM ; Hyung Yoon KIM ; Sahmin LEE ; Chi Young SHIM ; Eun Kyoung KIM ; Dong Hyuk CHO ; Jun Bean PARK ; Jeong Sook SEO ; Jung Woo SON ; In Cheol KIM ; Sang Hyun LEE ; Ran HEO ; Hyun Jung LEE ; Jae Hyeong PARK ; Jong Min SONG ; Sang Chol LEE ; Hyungseop KIM ; Duk Hyun KANG ; Jong Won HA ; Kye Hun KIM ;
Journal of Cardiovascular Imaging 2024;32(1):34-
10.Accuracy of bite registration according to the buccal bite scan range of intra-oral scanner
Tae-sung KWON ; Dae-hyun KIM ; Min-su KIM ; Dong-jun SONG ; Joo-Hun SONG
Journal of Dental Rehabilitation and Applied Science 2024;40(3):125-134
Purpose:
The aim of this study was to determine which scan range would provide the most accurate bite registration when perform-ing a bite scan after scanning an upper and lower arch using an intraoral scanner.
Materials and Methods:
The occlusal contact points were recorded using articulating paper for 30 adults, and the results of various ranges of buccal bite scan were compared based on this. Buccal bite scan of 5 ranges (1st premolar to 2nd premolar, 1st premolar to 1st molar, 1st premolar to 2nd molar, 2nd premolar to 1st molar, and canines to another side canine of the maxillary teeth) was performed, and then the buccal bite scan file was used in a CAD program to confirm the occlusal area in the scan file through data editing and alignment, leaving the buccal area of the teeth. Afterwards, the degree of agreement between the occlusal contact points obtained from the articulating paper and the occlusal area obtained from the scan file was compared, and statistical analysis was performed using the homoscedastic Ttest (α = 0.05).
Results:
The alignment success and alignment failure rates among each group were 77.23% and 40.85% in canine to another side canine, 68.23% and 28.89% in bilateral first premolar to second premolar, 63.76% and 29.97% in bilateral first premolar to first molar, 61.31% and 32.04% in bilateral first premolar to second molar, 67.55% and 27.46% in second premolar to first molar.The results of the anterior scan of both canines showed higher alignment success and failure rates compared to the scan results ofall maxillary posterior teeth. In the alignment success rate, statistical significance was not found depending on the scan range of the posterior teeth, but in comparing the results of the posterior teeth and both canines, statistical significance was observed except for the scan results of the second premolar to the first molar. There was no statistical significance in the alignment failure rate depend-ing on the scan range of the posterior teeth, and statistical significance was observed in the results of the posterior teeth and bothcanines.
Conclusion
When taking a buccal bite scan, in the case of scanning the anterior teeth, more occlusal area appear than when scanning the posterior teeth, and in the case of scanning the posterior teeth, there is no significant difference in the bite reg-istration depending on the scan range.

Result Analysis
Print
Save
E-mail