1.Considerations of Flow Cytometric Lymphocyte Subset Analysis in Korea Based on a Survey of Current Clinical Laboratory Practice
Mikyoung PARK ; Hyun-Woo CHOI ; Jihyang LIM ; Kyung-Hwa SHIN ; Eun-Jee OH ; Jaewoo SONG ; Kyeong-Hee KIM ; In Hwa JEONG ; Joo-Heon PARK ; Sang-Hyun HWANG ; Eun-Suk KANG
Annals of Laboratory Medicine 2026;46(2):220-225
Flow cytometric lymphocyte subset analysis (FCLSA) is essential for assessing immune status across various diseases and clinical settings. We surveyed current clinical laboratory practices related to FCLSA to establish a baseline reference for future standardization in Korea. Nine university hospitals actively performing FCLSA responded to the 22-question survey, which covered seven categories of laboratory practice. These hospitals used commercial reagent antibody kits from either Beckton Dickinson Biosciences (N = 4) or Beckman Coulter Diagnostics (N = 5). Most hospitals performed daily instrument setup and scheduled maintenance every 2–6 months. Two levels of commercial quality control materials were routinely used each day. Sample and reagent antibody volumes varied across hospitals, even when the same reagent kit was used. Acquired cell counts ranged from 5 × 10 3 to 5 × 10 4 cells, with two hospitals adjusting counts based on the cell type analyzed. Most laboratories reported percentages and general opinions; some additionally reported white blood cell and lymphocyte counts, along with lymphocyte percentages. This is the first comprehensive survey on the clinical laboratory practice of FCLSA in Korea.Standardization of FCLSA should be accelerated to ensure reliable and reproducible results.
2.Long-term Immunogenicity of the 13-valent Pneumococcal Conjugate Vaccine during Adjuvant Chemotherapy in Patients with Gastric and Colorectal Cancer: A 5-Year Follow-up of a Randomized Controlled Trial
Hyeon-Jong KIM ; Hyunjin BANG ; Hyun-Jung SHIM ; Jun Eul HWANG ; Sang-Hee CHO ; Ik-Joo CHUNG ; Seung Ji KANG ; Jong Gwang KIM ; Seung-Hoon BEOM ; A-Yeung JANG ; Joon Young SONG ; Woo Kyun BAE
Cancer Research and Treatment 2026;58(1):61-70
Purpose:
Current guidelines recommend vaccination at least 2 weeks before chemotherapy initiation to optimize the immune response despite limited evidence. Our previous study indicated no differences in short-term immune response for the 13-valent pneumococcal conjugate vaccine (PCV13) according to the vaccination timing. This study aims to investigate the long-term efficacy of PCV13 and clinical factors associated with the respective antibody response.
Materials and Methods:
Patients with gastric or colorectal cancer who received adjuvant chemotherapy were enrolled and divided into two groups: vaccinated 2 weeks before chemotherapy (arm A) and vaccinated concurrently with chemotherapy (arm B). Serum samples were collected before vaccination and in one month, 3 years, and 5 years. Immune responses were measured using enzyme-linked immunosorbent assay and multiplex opsonophagocytosis assay.
Results:
Including 63 patients, both groups showed an initial increase in the geometric mean titers of opsonophagocytic activity and the geometric mean concentrations of serotype-specific IgG levels after one month, followed by a decline at 3 and 5 years, particularly for serotypes 1, 14, 18C, and 19A. Despite the decline, global protection was maintained for 5 years, although global response decreased. The two arms did not show significant differences in immunogenicity nor in factors such as vaccination timing, age, cancer type, or chemotherapy regimen.
Conclusion
Vaccination timing is not a significant factor for the immunogenicity of PCV13 in cancer patients undergoing adjuvant chemotherapy. Global protection against pneumococcal infection was sustained for > 5 years, and global response remained in over half of patients.
3.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
4.Effect of Wearing Phospholipid-releasing Contact Lenses on Dry Eyes in Rabbits
Hyeon Jung KIM ; Sehie PARK ; Yun Kyoung RYU ; Jin Sun HWANG ; Sun Hee OH ; Jae Hwi LEE ; Gui Bae KIM ; Young Joo SHIN
Journal of the Korean Ophthalmological Society 2025;66(4):181-190
Purpose:
To investigate whether a new phospholipid-releasing soft contact lens can improve symptoms of dry eyes.
Methods:
The study used 2.5-3.0 kg New Zealand rabbits including both normal non-dry eye rabbits and dry eye rabbits, the latter having undergone electrocauterization of the meibomian glands to block the gland orifices. Each rabbit wore a control contact lens on one eye and a phospholipid-releasing contact lens on the other eye daily. Phospholipid-releasing and control contact lenses were provided by NEOVISION Co., Ltd. The parameters assessed included tear film break-up time, tear osmolarity, ocular surface staining, and central corneal thickness. After the experiment, the rabbits were euthanized and their conjunctival tissue was stained with Periodic Acid Schiff (PAS) to observe conjunctival goblet cells.
Results:
In both dry eye and normal non-dry eye rabbits, tear film break-up time was longer and tear osmolarity was lower when using the phospholipid-releasing contact lens compared to the control contact lens. The ocular surface remained unstained in normal non-dry eye rabbits while staining was observed in dry eye rabbits. There was no significant difference in central corneal thickness between the control and phospholipid-releasing contact lenses in either group. PAS staining showed no difference in conjunctival goblet cell density between the two lens types in normal non-dry eye rabbits. However, in dry eye rabbits, the conjunctival goblet cell density tended to be slightly higher with the phospholipid-releasing contact lens compared to the control lens.
Conclusions
Phospholipid-releasing contact lenses may help reduce dry eye symptoms and minimize contact lens-related complications by stabilizing the tear film and lowering tear osmolarity.
5.Utilization of Magnetic Resonance Imaging in the Diagnosis of Thymic Diseases
Joo Hui KIM ; Jae Ho CHUNG ; Sung Ho HWANG
Investigative Magnetic Resonance Imaging 2025;29(1):31-41
Thymic diseases such as thymic hyperplasia, thymic cysts, thymoma, and thymic carcinoma are common causes of mediastinal masses that present with diverse clinical and radiological features. Magnetic resonance imaging (MRI) is a pivotal tool for evaluating thymic pathologies as it offers superior soft-tissue contrast and has the ability to distinguish between benign and malignant lesions. Thymic MRI protocols include T1- and T2-weighted imaging, diffusion-weighted MRI (DW-MRI) with apparent diffusion coefficient mapping, and contrast-enhanced MRI (CE-MRI), each offering unique diagnostic insights into the composition and behavior of thymic lesions. However, interpreting MRI findings in thymic diseases may present challenges. Thymic cysts containing hemorrhage or proteinaceous material may mimic solid lesions owing to altered signal intensities, necessitating DW-MRI and CE-MRI for accurate differentiation. Small thymic lesions, particularly those <1 cm in diameter, are susceptible to signal distortion and partial volume effects, complicating their detection and characterization. Furthermore, respiratory and cardiac motion artifacts can degrade the image quality and obscure important diagnostic details, especially in lesions near the heart and lungs. Despite these challenges, MRI remains a critical imaging modality for assessing and managing thymic diseases, offering detailed tissue characterization. Interpretive pitfalls and technical limitations underscore the importance of employing optimized imaging protocols and expert analyses to ensure diagnostic accuracy and guide appropriate clinical decision-making.
6.Pyloric Dysfunction: A Review of the Mechanisms, Diagnosis, and Treatment
Hee Kyong NA ; Andrew A. LI ; Andres GOTTFRIED-BLACKMORE ; Alexander J. PODBOY ; Micaela M. ESQUIVEL ; Abel A. JOSEPH ; Linda NGUYEN ; Joo Ha HWANG
Gut and Liver 2025;19(3):327-345
Pyloric dysfunction is defined as hypertonia or spasm of the pyloric sphincter. The pylorus plays a key role in gastric emptying, but its function remains incompletely understood. Most studies have focused on gastroparesis regardless of the underlying pathophysiology. Few studies have reported pyloric dysfunction in patients with gastroparesis, and the diagnostic and treatment modalities for pyloric dysfunction are not well established. Recently developed diagnostic modalities assessing pyloric function, such as high-resolution antroduodenal manometry and endoluminal functional lumen imaging, are currently being evaluated. A variety of therapeutic interventions targeting the pylorus, including pharmacologic agents, intrapyloric botulinum injection, endoscopic balloon dilation, stent insertion, surgical pyloroplasty, and gastric peroral endoscopic pyloromyotomy, have been proposed. Among these, gastric peroral endoscopic pyloromyotomy has emerged as a novel, minimally invasive therapy with demonstrated efficacy and safety for refractory gastroparesis. This article reviews the pathophysiology of pyloric dysfunction and the potential diagnostic and therapeutic modalities based on the latest literature.
7.Erratum to "Abiraterone Acetate Attenuates SARS-CoV-2Replication by Interfering with the Structural Nucleocapsid Protein"
Jinsoo KIM ; Seok Young HWANG ; Dongbum KIM ; Minyoung KIM ; Kyeongbin BAEK ; Mijeong KANG ; Seungchan AN ; Junpyo GONG ; Sangkyu PARK ; Mahmoud KANDEEL ; Younghee LEE ; Minsoo NOH ; Hyung-Joo KWON
Biomolecules & Therapeutics 2025;33(1):231-232
8.Early Administration of Nelonemdaz May Improve the Stroke Outcomes in Patients With Acute Stroke
Jin Soo LEE ; Ji Sung LEE ; Seong Hwan AHN ; Hyun Goo KANG ; Tae-Jin SONG ; Dong-Ick SHIN ; Hee-Joon BAE ; Chang Hun KIM ; Sung Hyuk HEO ; Jae-Kwan CHA ; Yeong Bae LEE ; Eung Gyu KIM ; Man Seok PARK ; Hee-Kwon PARK ; Jinkwon KIM ; Sungwook YU ; Heejung MO ; Sung Il SOHN ; Jee Hyun KWON ; Jae Guk KIM ; Young Seo KIM ; Jay Chol CHOI ; Yang-Ha HWANG ; Keun Hwa JUNG ; Soo-Kyoung KIM ; Woo Keun SEO ; Jung Hwa SEO ; Joonsang YOO ; Jun Young CHANG ; Mooseok PARK ; Kyu Sun YUM ; Chun San AN ; Byoung Joo GWAG ; Dennis W. CHOI ; Ji Man HONG ; Sun U. KWON ;
Journal of Stroke 2025;27(2):279-283
9.Effect of Wearing Phospholipid-releasing Contact Lenses on Dry Eyes in Rabbits
Hyeon Jung KIM ; Sehie PARK ; Yun Kyoung RYU ; Jin Sun HWANG ; Sun Hee OH ; Jae Hwi LEE ; Gui Bae KIM ; Young Joo SHIN
Journal of the Korean Ophthalmological Society 2025;66(4):181-190
Purpose:
To investigate whether a new phospholipid-releasing soft contact lens can improve symptoms of dry eyes.
Methods:
The study used 2.5-3.0 kg New Zealand rabbits including both normal non-dry eye rabbits and dry eye rabbits, the latter having undergone electrocauterization of the meibomian glands to block the gland orifices. Each rabbit wore a control contact lens on one eye and a phospholipid-releasing contact lens on the other eye daily. Phospholipid-releasing and control contact lenses were provided by NEOVISION Co., Ltd. The parameters assessed included tear film break-up time, tear osmolarity, ocular surface staining, and central corneal thickness. After the experiment, the rabbits were euthanized and their conjunctival tissue was stained with Periodic Acid Schiff (PAS) to observe conjunctival goblet cells.
Results:
In both dry eye and normal non-dry eye rabbits, tear film break-up time was longer and tear osmolarity was lower when using the phospholipid-releasing contact lens compared to the control contact lens. The ocular surface remained unstained in normal non-dry eye rabbits while staining was observed in dry eye rabbits. There was no significant difference in central corneal thickness between the control and phospholipid-releasing contact lenses in either group. PAS staining showed no difference in conjunctival goblet cell density between the two lens types in normal non-dry eye rabbits. However, in dry eye rabbits, the conjunctival goblet cell density tended to be slightly higher with the phospholipid-releasing contact lens compared to the control lens.
Conclusions
Phospholipid-releasing contact lenses may help reduce dry eye symptoms and minimize contact lens-related complications by stabilizing the tear film and lowering tear osmolarity.
10.Cost-effectiveness of Fractional Flow Reserve Versus Intravascular Ultrasound to Guide Percutaneous Coronary Intervention: Results From the FLAVOUR Study
Doyeon HWANG ; Hea-Lim KIM ; Jane KO ; HyunJin CHOI ; Hanna JEONG ; Sun-ae JANG ; Xinyang HU ; Jeehoon KANG ; Jinlong ZHANG ; Jun JIANG ; Joo-Yong HAHN ; Chang-Wook NAM ; Joon-Hyung DOH ; Bong-Ki LEE ; Weon KIM ; Jinyu HUANG ; Fan JIANG ; Hao ZHOU ; Peng CHEN ; Lijiang TANG ; Wenbing JIANG ; Xiaomin CHEN ; Wenming HE ; Sung Gyun AHN ; Ung KIM ; You-Jeong KI ; Eun-Seok SHIN ; Hyo-Soo KIM ; Seung-Jea TAHK ; JianAn WANG ; Tae-Jin LEE ; Bon-Kwon KOO ;
Korean Circulation Journal 2025;55(1):34-46
Background and Objectives:
The Fractional Flow Reserve and Intravascular UltrasoundGuided Intervention Strategy for Clinical Outcomes in Patients with Intermediate Stenosis (FLAVOUR) trial demonstrated non-inferiority of fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) compared with intravascular ultrasound (IVUS)-guided PCI. We sought to investigate the cost-effectiveness of FFR-guided PCI compared to IVUS-guided PCI in Korea.
Methods:
A 2-part cost-effectiveness model, composed of a short-term decision tree model and a long-term Markov model, was developed for patients who underwent PCI to treat intermediate stenosis (40% to 70% stenosis by visual estimation on coronary angiography).The lifetime healthcare costs and quality-adjusted life-years (QALYs) were estimated from the healthcare system perspective. Transition probabilities were mainly referred from the FLAVOUR trial, and healthcare costs were mainly obtained through analysis of Korean National Health Insurance claims data. Health utilities were mainly obtained from the Seattle Angina Questionnaire responses of FLAVOUR trial participants mapped to EQ-5D.
Results:
From the Korean healthcare system perspective, the base-case analysis showed that FFR-guided PCI was 2,451 U.S. dollar lower in lifetime healthcare costs and 0.178 higher in QALYs compared to IVUS-guided PCI. FFR-guided PCI remained more likely to be cost-effective over a wide range of willingness-to-pay thresholds in the probabilistic sensitivity analysis.
Conclusions
Based on the results from the FLAVOUR trial, FFR-guided PCI is projected to decrease lifetime healthcare costs and increase QALYs compared with IVUS-guided PCI in intermediate coronary lesion, and it is a dominant strategy in Korea.

Result Analysis
Print
Save
E-mail