1.A prospective comparison of two ultrasound attenuation imaging modes using different frequencies for assessing hepatic steatosis
Hyeon Ji JANG ; Jong Keon JANG ; Subin HEO ; Boyeon KOO ; In Hye SONG ; Hee Jun PARK ; Seonghun YOON ; So Yeon KIM
Ultrasonography 2025;44(3):202-211
Purpose:
This study compared the diagnostic performance of two attenuation imaging (ATI) modes—low-frequency (3 MHz) and high-frequency (4 MHz)—for assessing hepatic steatosis, with histopathological hepatic fat fraction (HFF) as the reference standard.
Methods:
This prospective single-center study enrolled participants with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) scheduled for liver biopsy or surgery between June 2023 and June 2024. Attenuation coefficient (AC) values were consecutively measured using low- and high-frequency ATI modes, while the skin-to-region of interest distance (SRD) was measured simultaneously. Spearman correlation analysis evaluated the relationships of AC with HFF and SRD, and linear regression identified factors affecting AC. Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUROC).
Results:
In total, 119 participants (mean age, 37.2±12.0 years; 87 men) were included, with 73 (61.3%) diagnosed with MASLD. HFF ranged from 0% to 50%. The AC values in the lowfrequency mode were significantly higher than those in the high-frequency mode (0.61 vs. 0.54 dB/cm/MHz, P<0.001). HFF significantly influenced AC in both modes, whereas SRD affected AC only in the high-frequency mode (P<0.001). AC correlated positively with HFF in both modes (rs≥0.514, P<0.001) and negatively with SRD in the high-frequency mode (rs=-0.338, P<0.001). The AUROC for hepatic steatosis did not differ significantly between the two modes (0.751 vs. 0.771; P=0.609).
Conclusion
The low-frequency mode produced higher AC values than the high-frequency mode and demonstrated comparable diagnostic accuracy for assessing hepatic steatosis. Unlike the high-frequency mode, the low-frequency mode was not influenced by SRD.
2.Ultrasound-Guided Nerve Hydrodissection for the Management of Carpal Tunnel Syndrome:A Systematic Review and Network Meta-Analysis
KunWook LEE ; Jong Mi PARK ; Seo Yeon YOON ; Min Seo KIM ; Yong Wook KIM ; Jae Il SHIN ; Sang Chul LEE
Yonsei Medical Journal 2025;66(2):111-120
Purpose:
Ultrasound-guided nerve hydrodissection has emerged as a potential non-surgical treatment for carpal tunnel syndrome (CTS). The objective of this research was to offer suggestions for optimizing injectables utilized in hydrodissection for the treatment of CTS through a systematic review and network meta-analysis.
Materials and Methods:
PubMed, MEDLINE, EMBASE, Cochrane, Scopus, and Web of Science were searched through April 25, 2024. Effect sizes were quantified using standard mean differences within a random-effects model. Effectiveness ranking for each treatment was expressed as the surface under the cumulative ranking curve (SUCRA).
Results:
Nine studies with 458 patients with CTS were included. According to SUCRA, 5% dextrose (DW) was the most effective option for the Boston Carpal Tunnel Questionnaire (BCTQ) function at 99.9, 89.8, and 88.8 at 4, 12, and 24 weeks, respectively; for BCTQ symptoms, 5% DW was the most effective option at 99.9 at 4 weeks and platelet-rich plasma at 95.7 and 93.9 at 12 and 24 weeks, respectively. In terms of both BCTQ symptoms and BCTQ function, the 5 cc injection was the most effective, with SUCRA values of 99.5 for both categories. However, the effectiveness of the electrodiagnostic assessment and ultrasound variables was dependent on the type and dose of medication.
Conclusion
Administration of 5% DW showed better results in terms of initial symptom relief and long-term functional recovery compared to other agents, while platelet-rich plasma showed greater long-term symptom improvement; an injection dose of 5 cc showed the greatest benefit. However, additional research is required to establish precise protocols based on disease severity.
3.Development of the Korean Version of the Meaning in Life Scale for Cancer Patients
Namgu KANG ; Hae-Yeon YUN ; Young Ae KIM ; Hye Yoon PARK ; Jong-Heun KIM ; Sun Mi KIM ; Eun-Seung YU
Psychiatry Investigation 2025;22(3):258-266
Objective:
This study aims to understand the structure of meaning in life among patients with cancer through the validation of the Meaning in Life Scale among Korean patients (K-MiLS) with cancer.
Methods:
From August 2021 to November 2022, participants were recruited from multiple sites in South Korea. Participants completed related questionnaires, including the MiLS, on the web or mobile. Test-retest reliability was assessed between 2 and 4 weeks after the initial assessment. Exploratory and confirmatory factor analyses and Pearson’s correlations were used to evaluate the reliability and validity of the MiLS. A multiple regression analysis was conducted to examine the sociodemographic and disease-related variables correlated with the MiLS. Regarding concurrent validity, a hierarchical regression analysis was performed.
Results:
The results (n=345) indicated that the K-MiLS has a four-factor structure: Harmony and Peace; Life Perspective, Purpose, and Goals; Confusion and Lessened Meaning; and Benefits of Spirituality. Regarding convergent and discriminant validity, K-MiLS was negatively correlated with Patient Health Questionnaire-9, Generalized Anxiety Disorder-7, and Fear of Cancer Recurrence Inventory while showing a significantly positive correlation with the Posttraumatic Growth Inventory, Self-Compassion Scale, Functional Assessment of Cancer Therapy-General, and Functional Social Support Questionnaire. Hierarchical regression analysis revealed that the demographic variable influencing MiLS was religious affiliation.
Conclusion
The K-MiLS had a multidimensional four-factor structure similar to that of the original version. It is also a reliable and valid measure for assessing cancer survivors’ meaning in life after a cancer diagnosis.
4.High-Dose Rifampicin for 3 Months after Culture Conversion for Drug-Susceptible Pulmonary Tuberculosis
Nakwon KWAK ; Joong-Yub KIM ; Hyung-Jun KIM ; Byoung-Soo KWON ; Jae Ho LEE ; Jeongha MOK ; Yong-Soo KWON ; Young Ae KANG ; Youngmok PARK ; Ji Yeon LEE ; Doosoo JEON ; Jung-Kyu LEE ; Jeong Seong YANG ; Jake WHANG ; Kyung Jong KIM ; Young Ran KIM ; Minkyoung CHEON ; Jiwon PARK ; Seokyung HAHN ; Jae-Joon YIM
Tuberculosis and Respiratory Diseases 2025;88(1):170-180
Background:
This study aimed to determine whether a shorter high-dose rifampicin regimen is non-inferior to the standard 6-month tuberculosis regimen.
Methods:
This multicenter, randomized, open-label, non-inferiority trial enrolled participants with respiratory specimen positivity by Xpert MTB/RIF assay or Mycobacterium tuberculosis culture without rifampicin-resistance. Participants were randomized at 1:1 to the investigational or control group. The investigational group received high-dose rifampicin (30 mg/kg/day), isoniazid, and pyrazinamide until culture conversion, followed by high-dose rifampicin and isoniazid for 12 weeks. The control group received the standard 6-month regimen. The primary outcome was the rate of unfavorable outcomes at 18 months post-randomization. The non-inferiority margin was set at <6% difference in unfavorable outcomes rates. The study is registered with ClinicalTrials.gov (NCT04485156)
Results:
Between 4 November 2020 and 3 January 2022, 76 participants were enrolled. Of these, 58 were included in the modified intention-to-treat analysis. Unfavorable outcomes occurred in 10 (31.3%) of 32 in the control group and 10 (38.5%) of 26 in the investigational group. The difference was 7.2% (95% confidence interval, ∞ to 31.9%), failing to prove non-inferiority. Serious adverse events and grade 3 or higher adverse events did not differ between the groups.
Conclusion
The shorter high-dose rifampicin regimen failed to demonstrate non-inferiority but had an acceptable safety profile.
5.Effects of hepatic fibrosis on the quantification of hepatic steatosis using the controlled attenuation parameter in patients with chronic hepatitis B
Hee Jun PARK ; Hyo Jeong KANG ; So Yeon KIM ; Seonghun YOON ; Seunghee BAEK ; In Hye SONG ; Hyeon Ji JANG ; Jong Keon JANG
Ultrasonography 2025;44(1):83-91
Purpose:
This study assessed the impact of hepatic fibrosis on the diagnostic performance of the controlled attenuation parameter (CAP) in quantifying hepatic steatosis in patients with chronic hepatitis B (CHB).
Methods:
CHB patients who underwent liver stiffness measurement (LSM) and CAP assessment using transient elastography before liver resection between 2019 and 2022 were retrospectively evaluated. Clinical data included body mass index (BMI) and laboratory parameters. The histologically determined hepatic fat fraction (HFF) and fibrosis stages were reviewed by pathologists blinded to clinical and radiologic data. The Pearson correlation coefficient between CAP and HFF was calculated. The diagnostic performance of CAP for significant hepatic steatosis (HFF ≥10%) was assessed using areas under the receiver operating curve (AUCs), stratified by fibrosis stages (F0-1 vs. F2-4). Factors significantly associated with CAP were determined by univariable and multivariable linear regression analyses.
Results:
Among 399 CHB patients (median age 59 years; 306 men), 16.3% showed significant steatosis. HFF ranged from 0% to 60%. Of these patients, 9.8%, 19.8%, 29.3%, and 41.1% had fibrosis stages F0-1, F2, F3, and F4, respectively. CAP positively correlated with HFF (r=0.445, P<0.001). The AUC of CAP for diagnosing significant steatosis was 0.786 (95% confidence interval [CI], 0.726 to 0.845) overall, and significantly lower in F2-4 (0.772; 95% CI, 0.708 to 0.836) than in F0-1 (0.924; 95% CI, 0.835 to 1.000) (P=0.006). Multivariable analysis showed that BMI (P<0.001) and HFF (P<0.001) significantly affected CAP, whereas LSM and fibrosis stages did not.
Conclusion
CAP evaluations of significant hepatic steatosis are less reliable in CHB patients with significant or more advanced (F2-4) than with no or mild (F0-1) fibrosis.
6.A prospective comparison of two ultrasound attenuation imaging modes using different frequencies for assessing hepatic steatosis
Hyeon Ji JANG ; Jong Keon JANG ; Subin HEO ; Boyeon KOO ; In Hye SONG ; Hee Jun PARK ; Seonghun YOON ; So Yeon KIM
Ultrasonography 2025;44(3):202-211
Purpose:
This study compared the diagnostic performance of two attenuation imaging (ATI) modes—low-frequency (3 MHz) and high-frequency (4 MHz)—for assessing hepatic steatosis, with histopathological hepatic fat fraction (HFF) as the reference standard.
Methods:
This prospective single-center study enrolled participants with suspected metabolic dysfunction-associated steatotic liver disease (MASLD) scheduled for liver biopsy or surgery between June 2023 and June 2024. Attenuation coefficient (AC) values were consecutively measured using low- and high-frequency ATI modes, while the skin-to-region of interest distance (SRD) was measured simultaneously. Spearman correlation analysis evaluated the relationships of AC with HFF and SRD, and linear regression identified factors affecting AC. Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUROC).
Results:
In total, 119 participants (mean age, 37.2±12.0 years; 87 men) were included, with 73 (61.3%) diagnosed with MASLD. HFF ranged from 0% to 50%. The AC values in the lowfrequency mode were significantly higher than those in the high-frequency mode (0.61 vs. 0.54 dB/cm/MHz, P<0.001). HFF significantly influenced AC in both modes, whereas SRD affected AC only in the high-frequency mode (P<0.001). AC correlated positively with HFF in both modes (rs≥0.514, P<0.001) and negatively with SRD in the high-frequency mode (rs=-0.338, P<0.001). The AUROC for hepatic steatosis did not differ significantly between the two modes (0.751 vs. 0.771; P=0.609).
Conclusion
The low-frequency mode produced higher AC values than the high-frequency mode and demonstrated comparable diagnostic accuracy for assessing hepatic steatosis. Unlike the high-frequency mode, the low-frequency mode was not influenced by SRD.
7.Ultrasound-Guided Nerve Hydrodissection for the Management of Carpal Tunnel Syndrome:A Systematic Review and Network Meta-Analysis
KunWook LEE ; Jong Mi PARK ; Seo Yeon YOON ; Min Seo KIM ; Yong Wook KIM ; Jae Il SHIN ; Sang Chul LEE
Yonsei Medical Journal 2025;66(2):111-120
Purpose:
Ultrasound-guided nerve hydrodissection has emerged as a potential non-surgical treatment for carpal tunnel syndrome (CTS). The objective of this research was to offer suggestions for optimizing injectables utilized in hydrodissection for the treatment of CTS through a systematic review and network meta-analysis.
Materials and Methods:
PubMed, MEDLINE, EMBASE, Cochrane, Scopus, and Web of Science were searched through April 25, 2024. Effect sizes were quantified using standard mean differences within a random-effects model. Effectiveness ranking for each treatment was expressed as the surface under the cumulative ranking curve (SUCRA).
Results:
Nine studies with 458 patients with CTS were included. According to SUCRA, 5% dextrose (DW) was the most effective option for the Boston Carpal Tunnel Questionnaire (BCTQ) function at 99.9, 89.8, and 88.8 at 4, 12, and 24 weeks, respectively; for BCTQ symptoms, 5% DW was the most effective option at 99.9 at 4 weeks and platelet-rich plasma at 95.7 and 93.9 at 12 and 24 weeks, respectively. In terms of both BCTQ symptoms and BCTQ function, the 5 cc injection was the most effective, with SUCRA values of 99.5 for both categories. However, the effectiveness of the electrodiagnostic assessment and ultrasound variables was dependent on the type and dose of medication.
Conclusion
Administration of 5% DW showed better results in terms of initial symptom relief and long-term functional recovery compared to other agents, while platelet-rich plasma showed greater long-term symptom improvement; an injection dose of 5 cc showed the greatest benefit. However, additional research is required to establish precise protocols based on disease severity.
8.Diagnosis of Oral-Facial-Digital Syndrome I in a Patient with Suspected Polycystic Kidney Disease
Jiwon LEE ; Jong Eun PARK ; Sang-Woong HAN ; Mi-Yeon YU
Korean Journal of Medicine 2025;100(1):40-43
Polycystic kidney disease (PKD) typically manifests as genetic disease, which is commonly attributed to mutations in PKD genes. In this particular case, however, genetic analysis revealed that the patient’s PKD is linked to a novel, likely pathogenic variant (c.2184del; p.Thr729Leufs*88) in the oral-facial-digital syndrome type I (OFD1) gene. This is the first confirmed genetic diagnosis of mutations in the OFD1 gene in Korea. This investigation emphasizes the critical utility of panel sequencing of PKD in offering precise diagnosis and understanding the genetic profiles of PKD.
9.Validation of the Phoenix Criteria for Sepsis and Septic Shock in a Pediatric Intensive Care Unit
Chang Hoon HAN ; Hamin KIM ; Mireu PARK ; Soo Yeon KIM ; Jong Deok KIM ; Myung Hyun SOHN ; Seng Chan YOU ; Kyung Won KIM
Journal of Korean Medical Science 2025;40(10):e106-
The applicability of the Phoenix criteria and Phoenix Sepsis Score in higher-resource pediatric intensive care units (PICUs) outside the United States requires further validation. A retrospective cohort study analyzed electronic health records of 1,304 PICU admissions under 18 years old with suspected infection between February 2017 and December 2023. The score was calculated using two methods: 24-hour assessment, based on worst sub-scores within 24 hours of admission, and prompt assessment, using values closest to admission within 6 hours before or after. Based on the 24-hour assessment, in-hospital mortality was 8.3% for sepsis and 10.3% for septic shock. The score demonstrated an area under the precision-recall curve of 0.42 (95% confidence interval, 0.31–0.55) for in-hospital mortality. Results were consistent across both assessment methods. The Phoenix criteria and the Phoenix Sepsis Score are reliable predictors of mortality outcomes. Further investigation in diverse clinical settings is warranted.
10.Validation of the Phoenix Criteria for Sepsis and Septic Shock in a Pediatric Intensive Care Unit
Chang Hoon HAN ; Hamin KIM ; Mireu PARK ; Soo Yeon KIM ; Jong Deok KIM ; Myung Hyun SOHN ; Seng Chan YOU ; Kyung Won KIM
Journal of Korean Medical Science 2025;40(10):e106-
The applicability of the Phoenix criteria and Phoenix Sepsis Score in higher-resource pediatric intensive care units (PICUs) outside the United States requires further validation. A retrospective cohort study analyzed electronic health records of 1,304 PICU admissions under 18 years old with suspected infection between February 2017 and December 2023. The score was calculated using two methods: 24-hour assessment, based on worst sub-scores within 24 hours of admission, and prompt assessment, using values closest to admission within 6 hours before or after. Based on the 24-hour assessment, in-hospital mortality was 8.3% for sepsis and 10.3% for septic shock. The score demonstrated an area under the precision-recall curve of 0.42 (95% confidence interval, 0.31–0.55) for in-hospital mortality. Results were consistent across both assessment methods. The Phoenix criteria and the Phoenix Sepsis Score are reliable predictors of mortality outcomes. Further investigation in diverse clinical settings is warranted.

Result Analysis
Print
Save
E-mail