1.Clinical Application of Artificial Intelligence in Breast Ultrasound
John BAEK ; Jaeil KIM ; Hye Jung KIM ; Jung Hyun YOON ; Ho Yong PARK ; Jeeyeon LEE ; Byeongju KANG ; Iliya ZAKIRYAROV ; Askhat KULTAEV ; Bolat SAKTASHEV ; Won Hwa KIM
Journal of the Korean Society of Radiology 2025;86(2):216-226
Breast cancer is the most common cancer in women worldwide, and its early detection is critical for improving survival outcomes. As a diagnostic and screening tool, mammography can be less effective owing to the masking effect of fibroglandular tissue, but breast US has good sensitivity even in dense breasts. However, breast US is highly operator dependent, highlighting the need for artificial intelligence (AI)-driven solutions. Unlike other modalities, US is performed using a handheld device that produces a continuous real-time video stream, yielding 12000–48000 frames per examination. This can be significantly challenging for AI development and requires real-time AI inference capabilities. In this review, we classified AI solutions as computer-aided diagnosis and computer-aided detection to facilitate a functional understanding and review commercial software supported by clinical evidence.In addition, to bridge healthcare gaps and enhance patient outcomes in geographically under resourced areas, we propose a novel framework by reviewing the existing AI-based triage workflows including mobile ultrasound.
2.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
3.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
4.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
5.Clinical Application of Artificial Intelligence in Breast Ultrasound
John BAEK ; Jaeil KIM ; Hye Jung KIM ; Jung Hyun YOON ; Ho Yong PARK ; Jeeyeon LEE ; Byeongju KANG ; Iliya ZAKIRYAROV ; Askhat KULTAEV ; Bolat SAKTASHEV ; Won Hwa KIM
Journal of the Korean Society of Radiology 2025;86(2):216-226
Breast cancer is the most common cancer in women worldwide, and its early detection is critical for improving survival outcomes. As a diagnostic and screening tool, mammography can be less effective owing to the masking effect of fibroglandular tissue, but breast US has good sensitivity even in dense breasts. However, breast US is highly operator dependent, highlighting the need for artificial intelligence (AI)-driven solutions. Unlike other modalities, US is performed using a handheld device that produces a continuous real-time video stream, yielding 12000–48000 frames per examination. This can be significantly challenging for AI development and requires real-time AI inference capabilities. In this review, we classified AI solutions as computer-aided diagnosis and computer-aided detection to facilitate a functional understanding and review commercial software supported by clinical evidence.In addition, to bridge healthcare gaps and enhance patient outcomes in geographically under resourced areas, we propose a novel framework by reviewing the existing AI-based triage workflows including mobile ultrasound.
6.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
7.Clinical Application of Artificial Intelligence in Breast Ultrasound
John BAEK ; Jaeil KIM ; Hye Jung KIM ; Jung Hyun YOON ; Ho Yong PARK ; Jeeyeon LEE ; Byeongju KANG ; Iliya ZAKIRYAROV ; Askhat KULTAEV ; Bolat SAKTASHEV ; Won Hwa KIM
Journal of the Korean Society of Radiology 2025;86(2):216-226
Breast cancer is the most common cancer in women worldwide, and its early detection is critical for improving survival outcomes. As a diagnostic and screening tool, mammography can be less effective owing to the masking effect of fibroglandular tissue, but breast US has good sensitivity even in dense breasts. However, breast US is highly operator dependent, highlighting the need for artificial intelligence (AI)-driven solutions. Unlike other modalities, US is performed using a handheld device that produces a continuous real-time video stream, yielding 12000–48000 frames per examination. This can be significantly challenging for AI development and requires real-time AI inference capabilities. In this review, we classified AI solutions as computer-aided diagnosis and computer-aided detection to facilitate a functional understanding and review commercial software supported by clinical evidence.In addition, to bridge healthcare gaps and enhance patient outcomes in geographically under resourced areas, we propose a novel framework by reviewing the existing AI-based triage workflows including mobile ultrasound.
8.Clinical Pharmacogenetic Testing and Application:2024 Updated Guidelines by the Korean Society for Laboratory Medicine
John Hoon RIM ; Young-gon KIM ; Sollip KIM ; Rihwa CHOI ; Jee-Soo LEE ; Seungman PARK ; Woochang LEE ; Eun Young SONG ; Soo-Youn LEE ; Sail CHUN ;
Annals of Laboratory Medicine 2025;45(2):121-132
In the era of precision medicine, pharmacogenetics has substantial potential for addressing inter-individual variability in drug responses. Although pharmacogenetics has been a research focus for many years, resulting in the establishment of several formal guidelines, its clinical implementation remains limited to several gene–drug combinations in most countries, including Korea. The main causes of delayed implementation are technical challenges in genotyping and knowledge gaps among healthcare providers; therefore, clinical laboratories play a critical role in the timely implementation of pharmacogenetics. This paper presents an update of the Clinical Pharmacogenetic Testing and Application guidelines issued by the Korean Society for Laboratory Medicine and aims to provide the necessary information for clinical laboratories planning to implement or expand their pharmacogenetic testing. Current knowledge regarding nomenclature, gene–drug relationships, genotyping technologies, testing strategies, methods for clinically relevant information delivery, QC, and reimbursements has been curated and described in this guideline.
9.Perception of the educational environment among occupational therapy students at University of Santo Tomas: A study based on the Dundee Ready Educational Environment Measure (DREEM)
Kathlene Anne Hernandez ; Justine Anne Cua ; Jean Christine Libo-on ; Roselle Pauline Lim ; Anton Johann Muncada ; Lauren Tyler Que ; Marian Kim Reyes ; Martin John Ronquillo ; Priyanka Shelly Thakur
Philippine Journal of Allied Health Sciences 2024;8(1):8-18
BACKGROUND
Students’ perceptions of their educational environment have been determined to influence their educational performance, behavior, and well-being. Assessing the students’ educational environment enables stakeholders to recognize limitations and opportunities for ensuring optimal learning experiences. However, no studies have yet explored the perceived educational environment of occupational therapy (OT) students in the Philippines.
OBJECTIVEUsing the Dundee Ready Education Environment Measure (DREEM) instrument, this study assesses how occupational therapy students perceive their educational environment. Additionally, this study aims to identify strengths and weaknesses in the current educational environment.
METHODOLOGYThis descriptive cross-sectional study utilized a records review of anonymized secondary responses from the Student Life Survey 2021. The DREEM questionnaire was employed to evaluate the perspectives of occupational therapy students in five domains, namely: students’ perception of learning, students’ perceptions of academic self-perceptions, students’ perceptions of atmosphere, and students’ social self-perceptions. Individual item and subscale scores were summarized as mean and standard deviation (SD).
RESULTSWith a total mean score of 124.12 ± 26.79 in the five domains, the OT students positively perceive their educational environment. Data analysis revealed the scores for the DREEM domains of Students' Perception of Teachers (30.50 ± 6.08), Students' Perception of Learning (31.11 ± 5.94), Students' Academic Self-Perceptions (20.37 ± 4.26), Students’ Social Self-Perceptions (15.58 ± 4.00), and Students’ Perceptions of Atmosphere (26.56 ± 6.51). Interpretation for each domain indicates that the educational environment is moving in the right direction, has a more positive approach, is feeling more on the positive side, is not too bad, and has a more positive atmosphere, respectively.
CONCLUSIONThe study revealed a positive perception of the educational environment among OT students. However, there needed improvement in the areas of authoritarian teachers, the demanding program environment, and the overemphasis on factual learning. To guarantee that OT education in the country is of high quality, these findings can be utilized to inform the institution’s stakeholders regarding policy development, curriculum review, and future OT program development and implementation.
Human ; Perception ; Occupational Therapy
10.Phase 1/2a Study of Rivoceranib, a Selective VEGFR-2 Angiogenesis Inhibitor, in Patients with Advanced Solid Tumors
Yoon-Koo KANG ; Min-Hee RYU ; Yong Sang HONG ; Chang-Min CHOI ; Tae Won KIM ; Baek-Yeol RYOO ; Jeong Eun KIM ; John R. WEIS ; Rachel KINGSFORD ; Cheol Hee PARK ; Seong JANG ; Arlo MCGINN ; Theresa L. WERNER ; Sunil SHARMA
Cancer Research and Treatment 2024;56(3):743-750
Purpose:
This study aimed to report the results from an early-phase study of rivoceranib, an oral tyrosine kinase inhibitor highly selective for vascular endothelial growth factor receptor 2, in patients with advanced solid tumors.
Materials and Methods:
In this open-label, single-arm, dose-escalating, multicenter three-part phase 1/2a trial, patients had advanced solid tumors refractory to conventional therapy. Part 1 evaluated the safety and pharmacokinetics of five ascending once-daily doses of rivoceranib from 81 mg to 685 mg. Part 2 evaluated the safety and antitumor activity of once-daily rivoceranib 685 mg. Part 3 was conducted later, due to lack of maximum tolerated dose determination in part 1, to evaluate the safety and preliminary efficacy of once-daily rivoceranib 805 mg in patients with unresectable or advanced gastric cancer.
Results:
A total of 61 patients were enrolled in parts 1 (n=25), 2 (n=30), and 3 (n=6). In parts 1 and 2, patients were white (45.5%) or Asian (54.5%), and 65.6% were male. The most common grade ≥ 3 adverse events were hypertension (32.7%), hyponatremia (10.9%), and hypophosphatemia (10.9%). The objective response rate (ORR) was 15.2%. In part 3, dose-limiting toxicities occurred in two out of six patients: grade 3 febrile neutropenia decreased appetite, and fatigue. The ORR was 33%.
Conclusion
The recommended phase 2 dose of rivoceranib was determined to be 685 mg once daily, which showed adequate efficacy with a manageable safety profile (NCT01497704 and NCT02711969).


Result Analysis
Print
Save
E-mail