1.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
2.Clinical Application of Artificial Intelligence in Breast Ultrasound
John BAEK ; Jaeil KIM ; Hye Jung KIM ; Jung Hyun YOON ; Ho Yong PARK ; Jeeyeon LEE ; Byeongju KANG ; Iliya ZAKIRYAROV ; Askhat KULTAEV ; Bolat SAKTASHEV ; Won Hwa KIM
Journal of the Korean Society of Radiology 2025;86(2):216-226
Breast cancer is the most common cancer in women worldwide, and its early detection is critical for improving survival outcomes. As a diagnostic and screening tool, mammography can be less effective owing to the masking effect of fibroglandular tissue, but breast US has good sensitivity even in dense breasts. However, breast US is highly operator dependent, highlighting the need for artificial intelligence (AI)-driven solutions. Unlike other modalities, US is performed using a handheld device that produces a continuous real-time video stream, yielding 12000–48000 frames per examination. This can be significantly challenging for AI development and requires real-time AI inference capabilities. In this review, we classified AI solutions as computer-aided diagnosis and computer-aided detection to facilitate a functional understanding and review commercial software supported by clinical evidence.In addition, to bridge healthcare gaps and enhance patient outcomes in geographically under resourced areas, we propose a novel framework by reviewing the existing AI-based triage workflows including mobile ultrasound.
3.Clinical Application of Artificial Intelligence in Breast Ultrasound
John BAEK ; Jaeil KIM ; Hye Jung KIM ; Jung Hyun YOON ; Ho Yong PARK ; Jeeyeon LEE ; Byeongju KANG ; Iliya ZAKIRYAROV ; Askhat KULTAEV ; Bolat SAKTASHEV ; Won Hwa KIM
Journal of the Korean Society of Radiology 2025;86(2):216-226
Breast cancer is the most common cancer in women worldwide, and its early detection is critical for improving survival outcomes. As a diagnostic and screening tool, mammography can be less effective owing to the masking effect of fibroglandular tissue, but breast US has good sensitivity even in dense breasts. However, breast US is highly operator dependent, highlighting the need for artificial intelligence (AI)-driven solutions. Unlike other modalities, US is performed using a handheld device that produces a continuous real-time video stream, yielding 12000–48000 frames per examination. This can be significantly challenging for AI development and requires real-time AI inference capabilities. In this review, we classified AI solutions as computer-aided diagnosis and computer-aided detection to facilitate a functional understanding and review commercial software supported by clinical evidence.In addition, to bridge healthcare gaps and enhance patient outcomes in geographically under resourced areas, we propose a novel framework by reviewing the existing AI-based triage workflows including mobile ultrasound.
4.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
5.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
6.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
7.Clinical Application of Artificial Intelligence in Breast Ultrasound
John BAEK ; Jaeil KIM ; Hye Jung KIM ; Jung Hyun YOON ; Ho Yong PARK ; Jeeyeon LEE ; Byeongju KANG ; Iliya ZAKIRYAROV ; Askhat KULTAEV ; Bolat SAKTASHEV ; Won Hwa KIM
Journal of the Korean Society of Radiology 2025;86(2):216-226
Breast cancer is the most common cancer in women worldwide, and its early detection is critical for improving survival outcomes. As a diagnostic and screening tool, mammography can be less effective owing to the masking effect of fibroglandular tissue, but breast US has good sensitivity even in dense breasts. However, breast US is highly operator dependent, highlighting the need for artificial intelligence (AI)-driven solutions. Unlike other modalities, US is performed using a handheld device that produces a continuous real-time video stream, yielding 12000–48000 frames per examination. This can be significantly challenging for AI development and requires real-time AI inference capabilities. In this review, we classified AI solutions as computer-aided diagnosis and computer-aided detection to facilitate a functional understanding and review commercial software supported by clinical evidence.In addition, to bridge healthcare gaps and enhance patient outcomes in geographically under resourced areas, we propose a novel framework by reviewing the existing AI-based triage workflows including mobile ultrasound.
8.Clinical Pharmacogenetic Testing and Application:2024 Updated Guidelines by the Korean Society for Laboratory Medicine
John Hoon RIM ; Young-gon KIM ; Sollip KIM ; Rihwa CHOI ; Jee-Soo LEE ; Seungman PARK ; Woochang LEE ; Eun Young SONG ; Soo-Youn LEE ; Sail CHUN ;
Annals of Laboratory Medicine 2025;45(2):121-132
In the era of precision medicine, pharmacogenetics has substantial potential for addressing inter-individual variability in drug responses. Although pharmacogenetics has been a research focus for many years, resulting in the establishment of several formal guidelines, its clinical implementation remains limited to several gene–drug combinations in most countries, including Korea. The main causes of delayed implementation are technical challenges in genotyping and knowledge gaps among healthcare providers; therefore, clinical laboratories play a critical role in the timely implementation of pharmacogenetics. This paper presents an update of the Clinical Pharmacogenetic Testing and Application guidelines issued by the Korean Society for Laboratory Medicine and aims to provide the necessary information for clinical laboratories planning to implement or expand their pharmacogenetic testing. Current knowledge regarding nomenclature, gene–drug relationships, genotyping technologies, testing strategies, methods for clinically relevant information delivery, QC, and reimbursements has been curated and described in this guideline.
9.Applications of ocular point-of-care ultrasound assessment in the emergency setting: a scoping review
Christopher D. YANG ; Christine K. KIM ; Melissa M. CHANG ; Pooya KHOSRAVI ; Ajeet Pal Bayo BHATIA ; Amanda dos SANTOS ; Kyle DORNHOFER ; Megan GUY ; Edmund HSU ; Soheil SAADAT ; John Christian FOX
Clinical and Experimental Emergency Medicine 2025;12(3):188-197
Objective:
To evaluate the current body of literature pertaining to the use of ocular point-of-care ultrasound (POCUS) in the emergency department (ED).
Methods:
A comprehensive literature search was conducted on Scopus, Web of Science, MEDLINE, and Cochrane Central Register of Controlled Trials (CENTRAL) databases. Inclusion criteria were studies written in English and primary clinical studies involving ocular POCUS scans in an ED setting. Exclusion criteria were nonprimary studies (e.g., reviews or case reports), studies written in a non-English language, nonhuman studies, studies performed in a nonemergency setting, studies involving non-POCUS ocular ultrasound modalities, or studies published more than 10 years prior. Data extraction was guided by the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) recommendations.
Results:
The initial search yielded 391 results with 153 duplicates. Of the remaining 238 studies selected for retrieval and screening, 24 met the inclusion criteria. These 24 included studies encompassed 2,448 patients across prospective, retrospective, cross-sectional, and case series study designs. The majority of included studies focused on the use of POCUS in the ED to measure optic nerve sheath diameter as a proxy for papilledema and metabolic aberrations, while a minority of studies used ocular POCUS to assist in the diagnosis of orbital fractures or posterior segment pathology.
Conclusion
The vast majority of studies investigating the use of ocular POCUS in recent years emphasize its utility in measuring optic nerve sheath diameter and fluctuations in intracranial pressure, though additional outcomes of interest include pathology of the posterior segment, orbit, and globe.
10.Barriers to the implementation of sexual and reproductive health programs for adolescents in Eastern Visayas, Philippines: a thematic synthesis of national policies using a qualitative study
Kim Leonard G. dela Luna ; Alvin Duke R. Sy ; Rowel C. MALIMBAN ; John Oliver H. Estadilla ; Jasper M. MAGLINAB ; Heyeon JI ; Jihwan JEON ; Carl Mark Vincent B. Babasoro
Journal of Rural Medicine 2024;19(4):250-263
Objective: To review the implementation of essential reproductive health services in Eastern Visayas, Philippines.Materials and Methods: We reviewed four national policies through a qualitative research design using a series of key informant interviews conducted with service providers and focus group discussions with service beneficiaries.Results: There was a gap between the policies and the implementation of reproductive health services in the Eastern Visayas region. This gap is mainly due to the refusal of service providers to cater to teenagers’ needs regarding reproductive health services. This has resulted in teenagers hesitating to seek reproductive health services and related support from primary healthcare facilities. Service beneficiaries have also reported on the unavailability of several reproductive health services in primary healthcare facilities.Conclusion: The gap between national policies and program implementation must be bridged. This can be achieved by creating culturally-specific policies that can improve the implementation of reproductive health programs in the study areas.


Result Analysis
Print
Save
E-mail