1.Effect of electroacupuncture combined with low-frequency transcranial ultrasound stimulation on the electroencephalographic signals of rats with traumatic brain injury
Simiao GAO ; Xue HAN ; Xiaoguang WU ; Jinyu ZHENG ; Fangwen GAO ; Kuihua LI ; Yong PENG ; Lanxiang LIU
Chinese Journal of Tissue Engineering Research 2025;29(2):402-408
BACKGROUND:Traumatic brain injury is a condition in which the normal function of the brain is disrupted by a bump or impact to the head.It is necessary to find effective treatments and objective targets that can help doctors diagnose the injury status and restore the brain function of patients. OBJECTIVE:To explore the effect of electroacupuncture combined with low-frequency transcranial ultrasound stimulation on the electroencephalographic signals of rats with traumatic brain injury. METHODS:Forty 6-week-old SPF male Sprague-Dawley rats were randomly divided into five groups:sham group,model group,electroacupuncture group,low-frequency transcranial ultrasound stimulation group and combined group(electroacupuncture+low-frequency transcranial ultrasound stimulation),with eight rats in each group.Feeney weight-drop method was used to establish the animal model of traumatic brain injury.In the sham group,the bone window was only opened without impact.Interventions were started at 1 day after modeling.Electroacupuncture in the electroacupuncture group,low-frequency transcranial ultrasound stimulation in the low-frequency transcranial ultrasound stimulation group,and electroacupuncture+low-frequency transcranial ultrasound stimulation in the combined group were performed for days in total.The modified neurological severity scale score for assessing rats'neurological deficits was performed at 8 hours after modeling.The percentage of spontaneous alternation behavior in the Y-maze was measured at 7 days after modeling.Then,the electroencephalographic signals were collected and electroencephalographic data of α,β,θ,and δ waves were extracted by fast Fourier transform,and the value of oscillation amplitude and energy ratio were calculated in α,β,θ,and δ waves,as well as the Lempel-Ziv complexity and sample entropy. RESULTS AND CONCLUSION:Compared with the sham group,the modified neurological severity scale scores in the model group,electroacupuncture group,low-frequency transcranial ultrasound stimulation group and combined group were significantly increased at 8 hours after modeling(P<0.05).Compared with the sham group,the value of oscillation amplitude in δ wave and the value of δ energy ratio were significantly increased in the model group at 7 days after modeling,meanwhile the percentage of spontaneous alternation behavior in Y-maze,and the value of α/β energy ratio,Lempel-Ziv complexity,and sample entropy were significantly decreased(P<0.05).Compared with the model group,the value of oscillation amplitude in α and δ waves was significantly decreased in the combined group(P<0.05),while the value of α/β energy ratio was significantly increased(P<0.05)and the value of δ energy ratio was significantly decreased(P<0.05)in the electroacupuncture group,low-frequency transcranial ultrasound stimulation group and combined group.Compared with the electroacupuncture group and low-frequency transcranial ultrasound stimulation group,the value of δ energy ratio was significantly decreased in the combined group(P<0.05),while the percentage of spontaneous alternation behavior,the value of α/β energy ratio,the Lempel-Ziv complexity,and the sample entropy were significantly increased(P<0.05).To conclude,abnormal electroencephalographic signals can appear in rats with traumatic brain injury,while the electroacupuncture combined with low-frequency transcranial ultrasound stimulation can alleviate the abnormal electroencephalographic signals in rats,which suggests the electroencephalographic frequency domain value and nonlinear features can be used to assess the severity of traumatic brain injury.
2.Comprehensive Application of AHP-CRITIC Hybrid Weighting Method, Grey Correlation Analysis and BP-ANN in Optimization of Extraction Process of Qizhi Prescription
Qun LAN ; Yi CHENG ; Zian LI ; Bingyu WU ; Jinyu WANG ; Dewen LIU ; Yan TONG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(8):176-186
ObjectiveBased on analytic hierarchy process(AHP)-criteria importance through intercriteria correlation(CRITIC) hybrid weighting method, grey relational analysis and backpropagation artificial neural network(BP-ANN), to optimize the water extraction process of Qizhi prescription, so as to provide an experimental basis for optimization of the preparation process of this prescription and the establishment of quality standards. MethodsL9(34) orthogonal test was employed, and the AHP-CRITIC hybrid weighting method was utilized to determine the weight coefficients of the quality fractions of various components, including astragaloside Ⅳ, polygalaxanthone Ⅲ, calycosin-7-O-β-D-glucoside, tenuifolin, and 3,6′-disinapoylsucrose, as well as the dry extract yield. The comprehensive score of each factor level combination in the orthogonal test were calculated as evaluation indicator to select the optimal extraction process parameters. The effects of extraction times, extraction time, and solvent dosage on the aqueous extraction process of the formula were investigated through intuitive analysis, variance analysis, and grey relational analysis. Meanwhile, a BP-ANN model was established to reverse-predict the optimal extraction process parameters of Qizhi prescription, and the optimized process parameters were validated. ResultsThe weight coefficients of the five index components(astragaloside Ⅳ, tenuifolin, calycosin-7-O-β-D-glucoside, polygalaxanthone Ⅲ, and 3,6′-disinapoylsucrose) and dry extract yield were 25.7%, 20.82%, 16.41%, 12.45%, 15.96% and 8.67%, respectively. The optimized extraction process parameters were extracted 3 times with 8, 6, 6 times the amount of water, each time for 1 h. The network prediction results of BP-ANN test samples were consistent with the orthogonal test results, and the mean square error(MSE) of the predicted and measured values of the network was <1%. The water extraction process of Qizhi prescription analyzed and predicted by relevant mathematical models was stable and feasible, which could effectively improve the extraction efficiency of the active ingredients of Astragali Radix and Polygalae Radix, and the average comprehensive score of the validation test was 90.85 with the relative standard deviation(RSD) of 1.55%. ConclusionThis study establishes a water extraction process for compound Qizhi granules, and the optimized extraction process can effectively improve the extraction efficiency of active ingredients, which provides useful references for the optimization of preparation process and the establishment of quality standards for other clinical experience formulas.
3.Effect modification of amino acid levels in association between polycyclic aromatic hydrocarbon exposure and metabolic syndrome: A nested case-control study among coking workers
Jinyu WU ; Jiajun WEI ; Shugang GUO ; Huixia XIONG ; Yong WANG ; Hongyue KONG ; Liuquan JIANG ; Baolong PAN ; Gaisheng LIU ; Fan YANG ; Jisheng NIE ; Jin YANG
Journal of Environmental and Occupational Medicine 2025;42(3):325-333
Background Exposure to polycyclic aromatic hydrocarbons (PAHs) is associated with the development of metabolic syndrome (MS). However, the role of amino acids in PAH-induced MS remains unclear. Objective To explore the impact of PAHs exposure on the incidence of MS among coking workers, and to determine potential modifying effect of amino acid on this relationship. Methods Unmatched nested case-control design was adopted and the baseline surveys of coking workers were conducted in two plants in Taiyuan in 2017 and 2019, followed by a 4-year follow-up. The cohort comprised 667 coking workers. A total of 362 participants were included in the study, with 84 newly diagnosed cases of MS identified as the case group and 278 as the control group. Urinary levels of 11 PAH metabolites and plasma levels of 17 amino acids were measured by ultrasensitive performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Logistic regression was used to estimate the association between individual PAH metabolites and MS. Stratified by the median concentration of amino acids, Bayesian kernel machine regression (BKMR) model was employed to assess the mixed effects of PAHs on MS. Due to the skewed data distribution, all PAH metabolites and amino acids in the analysis were converted by natural logarithm ln (expressed as lnv). Results The median age of the 362 participants was 37 years, and 83.2% were male. Compared to the control group, the case group exhibited higher concentrations of urinary 2-hydroxyphenanthrene (2-OHPhe), 9-hydroxyphenanthrene (9-OHPhe), and hydroxyphenanthrene (OHPhe) (P=0.005, P=0.049, and P=0.004, respectively), as well as elevated levels of plasma branched chain amino acid (BCAA) and aromatic amino acid (AAA) (P<0.05). After being adjusted for confounding factors, for every unit increase in lnv2-OHPhe in urine, the OR (95%CI) of MS was 1.57 (1.11, 2.26), and for every unit increase in lnvOHPhe, the OR (95%CI) of MS was 1.82 (1.16, 2.90). Tyrosine, leucine, and AAA all presented a significant nonlinear correlation with MS. At low levels, tyrosine, leucine, and AAA did not significantly increase the risk of MS, but at high levels, they increased the risk of MS. In the low amino acid concentration group, as well as in the low BCAA and low AAA concentration groups, it was found that compared to the PAH metabolite levels at the 50th percentile (P50), the log-odds of MS when the PAH metabolite levels was at the 75th percentile (P75) were 0.158 (95%CI: 0.150, 0.166), 0.218 (95%CI: 0.209, 0.227), and 0.262 (95% CI: 0.241, 0.282), respectively, However, no correlation between PAHs and MS was found in the high amino acid concentration group. Conclusion Amino acids modify the effect of PAHs exposure on the incidence of MS. In individuals with low plasma amino acid levels, the risk of developing MS increases with higher concentrations of mixed PAH exposure. This effect is partly due to the low concentrations of BCAA and AAA.
4.Association between nighttime sleep duration, physical activity and disability among the elderly
XIA Min ; QIAN Jinyu ; YAN Panpan ; WU Qian
Journal of Preventive Medicine 2025;37(6):556-561
Objective:
To investigate the association between nighttime sleep duration, physical activity and disability among the elderly, so as to provide the basis for reduce the risk of disability and promote healthy aging.
Methods:
Based on the 2020 database of China Health and Retirement Longitudinal Study (CHARLS), demographic information, lifestyle behaviors, chronic diseases and nighttime sleep duration were collected from people aged 60 years and older. Physical activity level was evaluated using the International Physical Activity Questionnaire-Short. Disability status was measured using the basic Activities of Daily Living (ADL) scale. Association between nighttime sleep duration, physical activity and disability among the elderly were analyzed using multivariable logistic regression model.
Results:
Totally 11 126 elderly participants were enrolled, with 5 423 males (48.74%) and 5 703 females (51.26%). The mean age was (69.92±7.08) years. Among them, 6 838 individuals (61.46%) had a nighttime sleep duration of <7 hours, and 2 247 individuals (20.20%) had a physical activity level of <600 MET-min/week. A total of 3 213 individuals were identified as having disability, with a detection rate of 28.88%. Multivariable logistic regression analysis showed that, after adjusting for age, gender, marital status, education level, residence, smoking, alcohol consumption, and multimorbidity of chronic diseases, compared with a nighttime sleep duration of 7-8 hours, those with <7 hours (OR=1.535, 95%CI: 1.386-1.700) and >8 hours (OR=1.186, 95%CI: 1.003-1.402) had an increased risk of disability by 53.5% and 18.6%, respectively. Compared with a physical activity level of ≥600 MET-min/week, those with <600 MET-min/week (OR=2.106, 95%CI: 1.901-2.335) had an increased risk of disability by 110.6%. Compared with those who had a nighttime sleep duration of 7-8 hours and a physical activity level of ≥600 MET-min/week, the elderly with a nighttime sleep duration of <7 hours and a physical activity level of <600 MET-min/week (OR=3.299, 95%CI: 2.831-3.843), a nighttime sleep duration of >8 hours and a physical activity level of <600 MET-min/week (OR=2.566, 95%CI: 1.954-3.369), a nighttime sleep duration of 7-8 hours and a physical activity level of <600 MET-min/week (OR=1.911, 95%CI: 1.564-2.334), and a nighttime sleep duration of <7 hours and a physical activity level of ≥600 MET-min/week (OR=1.503, 95%CI: 1.334-1.692) had an increased risk of disability by 229.9%, 156.6%, 91.1%, and 50.3%, respectively.
Conclusion
Short or long nighttime sleep duration and low physical activity levels can increase the risk of disability in the elderly.
5.Effects of Sanqi on Sortilin,TLRs and vascular calcification in rats with chronic renal failure
Zhimin HUANG ; Liangxi LU ; Yini JIANG ; Xiaoyu LIU ; Zhiying ZHANG ; Jinyu WU
The Journal of Practical Medicine 2024;40(6):773-779
Objective Taking Sortilin as the entry point,this study aims to explore the mechanism of vascular calcification in chronic renal failure(CRF)and explore the influence of Sanqi on Sortilin,TLRs and vascular calcification,and to provide an effective method for clinical reduction of cardiovascular events in CRF.Methods Thirty-six male SD rats were randomly divided into normal group,model group,low-,medium-and high-dose Sanqi group and calcitriol group,with 6 rats in each.The replicative CRF vascular calcification rat model was fed with adenine combined with high phosphorus diet.Aortic calcium salt deposition,serum creatinine(Scr),urea nitrogen(BUN),blood calcium(Ca),blood phosphorus(P),total cholesterol(TC),triglyceride(TG),TLRs and Sortilin protein in aorta and inflammatory factors were detected.Results In the model group,renal fibrosis was obvious and many adenine crystals were found in renal interstitium.Large deposits of calcium salts were found.Renal fibrosis and calcium salt deposition were alleviated in different degrees in all treatment groups.Compared with those in the normal group,the level of BUN,Cr,P,TG,TC,IFN-γ,IL-6,IL-10 and IL-17A in the serum of the model group was ascended(P<0.01),while the level of Ca was descended(P<0.01).Compared with those in the model group,the level of BUN,Cr,P,TG,TC,IFN-γ,IL-6,IL-10 and IL-17A in the serum of rats in the Sanqi medium and high dose group and calcitriol group was significantly decreased(P<0.01),and the contents of Ca were significantly increased(P<0.05 or P<0.01).Compared with those in the normal group,the protein expression of BMP2,RUNX2,Sortilin,TLR7 and TLR9 in aortic tissue of rats in the model group was elevated(P<0.01),while the protein expression of SM22α was declined(P<0.01).Compared with those in the model group,the protein expression of BMP2,RUNX2,Sortilin,TLR7,and TLR9 in the low-,medium-,and high-dose Sanqi group and calcitriol group was decreased significantly(P<0.01);the protein expression of SM22α was increased significantly(P<0.05 or P<0.01),and the high-dose Sanqi group and calcitriol group had more significant effects.Conclusion Sanqi can improve renal fibrosis and vascular calcification in CRF model rats,and its mechanism may be related to the regulation of biological functions of Sortilin and TLRs.
6.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
7.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
8.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
9.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
10.Comparative study of different large language models and medical professionals of different levels responding to ophthalmology questions
Hui HUANG ; Jinyu HU ; Xiaoyu WANG ; Shuyuan YE ; Shinan WU ; Cheng CHEN ; Liangqi HE ; Yanmei ZENG ; Hong WEI ; Yi SHAO
International Eye Science 2024;24(3):458-462
AIM: To evaluate the performance of three distinct large language models(LLM), including GPT-3.5, GPT-4, and PaLM2, in responding to queries within the field of ophthalmology, and to compare their performance with three different levels of medical professionals: medical undergraduates, master of medicine, and attending physicians.METHODS: A total of 100 ophthalmic multiple-choice tests, which covered ophthalmic basic knowledge, clinical knowledge, ophthalmic examination and diagnostic methods, and treatment for ocular disease, were conducted on three different kinds of LLM and three different levels of medical professionals(9 undergraduates, 6 postgraduates and 3 attending physicians), respectively. The performance of LLM was comprehensively evaluated from the aspects of mean scores, consistency and confidence of response, and it was compared with human.RESULTS: Notably, each LLM surpassed the average performance of undergraduate medical students(GPT-4:56, GPT-3.5:42, PaLM2:47, undergraduate students:40). Specifically, performance of GPT-3.5 and PaLM2 was slightly lower than those of master's students(51), while GPT-4 exhibited a performance comparable to attending physicians(62). Furthermore, GPT-4 showed significantly higher response consistency and self-confidence compared with GPT-3.5 and PaLM2.CONCLUSION: LLM represented by GPT-4 performs well in the field of ophthalmology, and the LLM model can provide clinical decision-making and teaching aids for clinicians and medical education.


Result Analysis
Print
Save
E-mail