1.Effects of Different Anticipated Conditions on Biomechanical Characteristics of Lower Limbs in Individuals with Chronic Ankle Instability
Ling WANG ; Peng CHEN ; Huiwu ZUO ; Xinxin LIU ; Junjie NIU ; Kejun LI ; Xin LIU ; Haitao LIU ; Jinwu WANG
Journal of Medical Biomechanics 2025;40(4):980-987
Objective The differences in biomechanical characteristics of the lower limbs between individuals with chronic ankle instability(CAI)and healthy individuals during unanticipated and anticipated jumping were compared,in order to provide practical references and ideas for the prevention and treatment of recurrent ankle sprains.Methods Thirty subjects were recruited,including 15 patients with CAI and 15 healthy volunteers.All subjects completed unanticipated and anticipated jumping tests in a random order,with a 1-week interval between the two tests.Kinematic and kinetic data of lower limbs were collected synchronously using Vicon infrared high-speed motion capture system and Kistler three-dimensional force platform.Results At the moment of touchdown,knee flexion angle was significantly greater during unanticipated jumping than that during anticipated jumping(P=0.009),while ankle eversion angle was notably lower(P=0.043).During the early landing phase,unanticipated jumping showed significantly greater peak hip flexion and abduction angles,as well as knee flexion(P=0.038,P=0.036,P=0.04),while peak ankle dorsiflexion and eversion angles were significantly lower(P=0.001,P=0.01)compared to anticipated jumping.Additionally,peak hip abduction moment during unanticipated jumping was significantly higher in patients with CAI than that during anticipated jumping(P=0.028).Conclusions Unanticipated jumping reduced ankle dorsiflexion and eversion angles in individuals with CAI,putting the ankle in an open,sprain-prone position.Individuals with CAI compensated proximally by increasing hip flexion,abduction,knee flexion angles,and hip extension moment to stabilize the ankle.
2.Finite Element Analysis and Clinical Application of Three-Dimensional-Printed Personalized Cervical Correction Pillow
Ya LI ; Yuncheng WU ; Zhaozhao WU ; Xunjun MA ; Jiaqi LIU ; Yongjun JIANG ; Jinwu WANG
Journal of Medical Biomechanics 2025;40(1):118-125
Objective To evaluate the safety and therapeutic efficacy of three-dimensional(3D)-printed personalized cervical correction pillows for treating cervical spondylotic radiculopathy.Methods A finite element model was established to simulate and analyze the biomechanical changes in cervical spine before and after using the pillow.Additionally,20 patients with chronic neck pain were included to analyze changes in visual analogue scale(VAS)scores,neck disability index(NDI),pressure pain threshold(PPT),Borden value,cervical lordosis,T1 slope,cervical slope,and thoracic inlet angle before and after using the pillow.Results Finite element analysis indicated that the maximum stress on vertebral bodies increased by 64.35%and the maximum stress on cartilage tissues by 5.09%after using the pillow.The Borden value improved by 45.75%.Clinical studies showed a significant reduction in VAS scores,NDI,and PPT after treatment(P<0.05),while PPT,Borden value,cervical lordosis,T1 slope,and thoracic inlet angle significantly increased(P<0.05).Conclusions The 3D-printed personalized cervical correction pillow is safe and effective in alleviating neck pain and improving cervical curvature,and it provides a new and effective non-surgical treatment option for cervical spondylotic radiculopathy,with significant clinical implications.
3.Study on the prognostic factors related to interventional therapy in patients with acute myocardial infarction assisted by VA-ECMO
Junduo WU ; Chunpeng ZHANG ; Bo LI ; Lei ZHAO ; Jinwu LI ; Mingsong ZHANG ; Shengnan XU ; Bin LIU
Chinese Journal of Cardiology 2025;53(6):661-665
Objective:To investigate the prognostic factors in patients with acute myocardial infarction (AMI) who underwent interventional therapy assisted by venous-arterial extracorporeal membrane oxygenation (VA-ECMO).Methods:This single-center retrospective cohort study enrolled AMI patients who received VA-ECMO-assisted interventional therapy in the Department of Cardiology at the Second Hospital of Jilin University from June 2018 to November 2022. Patients were divided into the in-hospital survival group and in-hospital death group based on the in-hospital survival. Data on patient demographics, laboratory tests, imaging examinations, coronary angiography results, VA-ECMO-related parameters, complications, and prognosis were collected through the electronic medical record system.Results:A total of 71 AMI patients were enrolled, with an age of (62.4±11.1) years, of whom 54 (76%) were male. There were 46 patients in the in-hospital survival group and 25 patients in the in-hospital death group. Compared to the in-hospital survival group, the in-hospital death group exhibited significantly higher levels of cardiac troponin I (36.08 (2.86, 100.00) μg/L vs. 2.75 (0.18, 13.86) μg/L, P=0.01) and B-type natriuretic peptide (1 724.50 (50.00, 4 200.50) vs. 460.85 (163.80, 1 862.33), P=0.01), and the left ventricular ejection fraction was lower ((35.0±12.9)% vs. (43.0±12.8)%, P=0.01), moreover the incidence of patients with left main coronary artery disease (80% (20/25) vs. 39% (18/46), P<0.01), cardiac arrest (56% (14/25) vs. 20% (9/46), P<0.01), cardiopulmonary resuscitation (52%(13/25) vs. 26%(12/46), P=0.03), and the time from cardiac arrest to ECMO initiation >24 hours (84% (21/25) vs. 9% (4/46), P<0.01) were higher. Conclusions:The prognosis of AMI patients undergoing VA-ECMO-assisted interventional therapy may be influenced by a number of related factors, including cardiac troponin I, B-type natriuretic peptide levels, left ventricular ejection fraction, combined with left main coronary artery disease, cardiac arrest and cardiopulmonary resuscitation, and the interval between cardiac arrest and the initiation of ECMO.
4.A Three-Dimensional Motion Measurement Technique for the Knee Joint Based on Biplane High-Speed Photography
Jianping WANG ; Jun ZHANG ; Yanqing WANG ; Qiang LI ; Jinwu WANG ; Dongdong ZHAO ; Xi ZENG ; Hai HU
Journal of Medical Biomechanics 2025;40(2):412-420
Objective To measure the three-dimensional(3D)motion of the knee joint in healthy people and patients after total knee arthroplasty(TKA).Methods The coordinate system for the tibia and femur of the knee joint was established,and the marking points were pasted at the bone landmarks.Then the 3D motion of human knee joint was measured by biplane high-speed photogrammetry,and the data were processed according to the coordinate transformation.Results The peak values of adduction and abduction,internal and external rotation,internal and external translation,and proximal and distal movement of the artificial knee joint were larger than those of the healthy knee joint(P<0.05),but there was no statitistic difference in posterior displacement between the artificial and healthy knee joints(P=0.05).Conclusions By measuring the knee joint motion,not only the difference in knee joint motion between the healthy volunteers and TKA patients was revealed,but also the effectiveness of biplane high-speed photography in knee joint kinematic measurement was demonstrated.
5.Effects of Medial Collateral Ligament Release on Knee Joint Squatting Motion after Total Knee Arthroplasty
Haijun QU ; Zhongxu XIAO ; Guokai DU ; Zhansheng BA ; Qiang LI ; Jinwu WANG ; Xiaohui ZHANG ; Jianping WANG
Journal of Medical Biomechanics 2025;40(5):1136-1143
Objective To study the effect of medial collateral ligament(MCL)release on the squatting motion followling total knee arthroplasty(TKA)and provide reference data for ligament release during knee replacement surgery.Methods Based on CT and MRI images of a volunteer,a three-dimensional(3D)geometric anatomical model of the natural knee joint including bone tissues and major soft tissues was established.A finite element model of the artificial knee joint was established by simulating TKA surgery.The squatting motion after 30%release of the upper end,lower end,and both ends of the MCL was simulated,and motion characteristic data of the knee joint at flexion/extension angles from 0° to 135° were obtained.Results The effects of ligament release at different locations on knee squatting motion varied.After releasing the lower end,the medial translation,posterior translation,superior translation,and adduction of the femur relative to the tibia increased by 13.74%,3.83%,9.74%,and 2.37%,respectively,while the external rotation decreased by 36.8%.After releasing the upper end,the medial translation and posterior translation increased by 10.65%and 10%,respectively,while the superior translation,adduction,and external rotation decreased by 4.52%,33.89%,and 67.1%,respectively.After releasing both ends,the medial translation,posterior translation,and superior translation increased by 14.77%,9.39%,and 22.56%,respectively,while the adduction and external rotation decreased by 15.62%and 47.3%,respectively.Conclusions After MCL released,the medial translation,anterior translation,superior translation,and abduction of the femur relative to the tibia increased,while the external rotation decreased.Releasing the lower end had the least effect on these femoral movements,showing an obvious advantage.
6.Prediction and Clinical Evaluation of Cobb Angle in Idiopathic Scoliosis Using Machine Learning and Three-Point Mechanical Data of 3D-Printed Orthotics
Xunjun MA ; Ya LI ; Jun YU ; Haitao LIU ; Yuncheng WU ; Jinwu WANG
Journal of Medical Biomechanics 2025;40(2):364-370
Objective A Cobb angle prediction model for adolescent idiopathic scoliosis(AIS)based on three-point mechanical data from three-dimensional(3D)-printed orthotics and various machine learning algorithms was developed,so as to provide an innovative,radiation-free method for early clinical screening and monitoring of AIS.Methods Clinical data from AIS patients and mechanical data from 3D-printed orthotics were collected to construct a comprehensive dataset with features such as gender,age,disease type,weight,and Risser score.Six algorithms,namely,random forest,support vector regression,gradient boosting regressor,extreme gradient boosting,lightgbm,and catboost,were used to construct and evaluate the performance of Cobb angle prediction models.Results The gradient boosting regressor model had the best performance on several evaluation metrics,achieving a precision rate of 0.937,recall rate of 0.818,F1-score of 0.949,and an area under curve(AUC)value of 0.843.In the validation set,the model's predictions reached an accuracy rate of 0.942,fitting well with the actual Cobb values.Conclusions The Cobb angle prediction model based on mechanical data and machine learning effectively avoids the radiation risks associated with traditional full-spine X-ray examinations in early clinical screening.It provides a non-invasive assessment for AIS patients,enhancing the safety and efficiency of screening and monitoring,and offering a powerful decision-making tool for clinicians,with a great clinical significance.
7.Effects of Medial Collateral Ligament Release on Knee Joint Squatting Motion after Total Knee Arthroplasty
Haijun QU ; Zhongxu XIAO ; Guokai DU ; Zhansheng BA ; Qiang LI ; Jinwu WANG ; Xiaohui ZHANG ; Jianping WANG
Journal of Medical Biomechanics 2025;40(5):1136-1143
Objective To study the effect of medial collateral ligament(MCL)release on the squatting motion followling total knee arthroplasty(TKA)and provide reference data for ligament release during knee replacement surgery.Methods Based on CT and MRI images of a volunteer,a three-dimensional(3D)geometric anatomical model of the natural knee joint including bone tissues and major soft tissues was established.A finite element model of the artificial knee joint was established by simulating TKA surgery.The squatting motion after 30%release of the upper end,lower end,and both ends of the MCL was simulated,and motion characteristic data of the knee joint at flexion/extension angles from 0° to 135° were obtained.Results The effects of ligament release at different locations on knee squatting motion varied.After releasing the lower end,the medial translation,posterior translation,superior translation,and adduction of the femur relative to the tibia increased by 13.74%,3.83%,9.74%,and 2.37%,respectively,while the external rotation decreased by 36.8%.After releasing the upper end,the medial translation and posterior translation increased by 10.65%and 10%,respectively,while the superior translation,adduction,and external rotation decreased by 4.52%,33.89%,and 67.1%,respectively.After releasing both ends,the medial translation,posterior translation,and superior translation increased by 14.77%,9.39%,and 22.56%,respectively,while the adduction and external rotation decreased by 15.62%and 47.3%,respectively.Conclusions After MCL released,the medial translation,anterior translation,superior translation,and abduction of the femur relative to the tibia increased,while the external rotation decreased.Releasing the lower end had the least effect on these femoral movements,showing an obvious advantage.
8.Prediction and Clinical Evaluation of Cobb Angle in Idiopathic Scoliosis Using Machine Learning and Three-Point Mechanical Data of 3D-Printed Orthotics
Xunjun MA ; Ya LI ; Jun YU ; Haitao LIU ; Yuncheng WU ; Jinwu WANG
Journal of Medical Biomechanics 2025;40(2):364-370
Objective A Cobb angle prediction model for adolescent idiopathic scoliosis(AIS)based on three-point mechanical data from three-dimensional(3D)-printed orthotics and various machine learning algorithms was developed,so as to provide an innovative,radiation-free method for early clinical screening and monitoring of AIS.Methods Clinical data from AIS patients and mechanical data from 3D-printed orthotics were collected to construct a comprehensive dataset with features such as gender,age,disease type,weight,and Risser score.Six algorithms,namely,random forest,support vector regression,gradient boosting regressor,extreme gradient boosting,lightgbm,and catboost,were used to construct and evaluate the performance of Cobb angle prediction models.Results The gradient boosting regressor model had the best performance on several evaluation metrics,achieving a precision rate of 0.937,recall rate of 0.818,F1-score of 0.949,and an area under curve(AUC)value of 0.843.In the validation set,the model's predictions reached an accuracy rate of 0.942,fitting well with the actual Cobb values.Conclusions The Cobb angle prediction model based on mechanical data and machine learning effectively avoids the radiation risks associated with traditional full-spine X-ray examinations in early clinical screening.It provides a non-invasive assessment for AIS patients,enhancing the safety and efficiency of screening and monitoring,and offering a powerful decision-making tool for clinicians,with a great clinical significance.
9.Effects of Different Anticipated Conditions on Biomechanical Characteristics of Lower Limbs in Individuals with Chronic Ankle Instability
Ling WANG ; Peng CHEN ; Huiwu ZUO ; Xinxin LIU ; Junjie NIU ; Kejun LI ; Xin LIU ; Haitao LIU ; Jinwu WANG
Journal of Medical Biomechanics 2025;40(4):980-987
Objective The differences in biomechanical characteristics of the lower limbs between individuals with chronic ankle instability(CAI)and healthy individuals during unanticipated and anticipated jumping were compared,in order to provide practical references and ideas for the prevention and treatment of recurrent ankle sprains.Methods Thirty subjects were recruited,including 15 patients with CAI and 15 healthy volunteers.All subjects completed unanticipated and anticipated jumping tests in a random order,with a 1-week interval between the two tests.Kinematic and kinetic data of lower limbs were collected synchronously using Vicon infrared high-speed motion capture system and Kistler three-dimensional force platform.Results At the moment of touchdown,knee flexion angle was significantly greater during unanticipated jumping than that during anticipated jumping(P=0.009),while ankle eversion angle was notably lower(P=0.043).During the early landing phase,unanticipated jumping showed significantly greater peak hip flexion and abduction angles,as well as knee flexion(P=0.038,P=0.036,P=0.04),while peak ankle dorsiflexion and eversion angles were significantly lower(P=0.001,P=0.01)compared to anticipated jumping.Additionally,peak hip abduction moment during unanticipated jumping was significantly higher in patients with CAI than that during anticipated jumping(P=0.028).Conclusions Unanticipated jumping reduced ankle dorsiflexion and eversion angles in individuals with CAI,putting the ankle in an open,sprain-prone position.Individuals with CAI compensated proximally by increasing hip flexion,abduction,knee flexion angles,and hip extension moment to stabilize the ankle.
10.Finite Element Analysis and Clinical Application of Three-Dimensional-Printed Personalized Cervical Correction Pillow
Ya LI ; Yuncheng WU ; Zhaozhao WU ; Xunjun MA ; Jiaqi LIU ; Yongjun JIANG ; Jinwu WANG
Journal of Medical Biomechanics 2025;40(1):118-125
Objective To evaluate the safety and therapeutic efficacy of three-dimensional(3D)-printed personalized cervical correction pillows for treating cervical spondylotic radiculopathy.Methods A finite element model was established to simulate and analyze the biomechanical changes in cervical spine before and after using the pillow.Additionally,20 patients with chronic neck pain were included to analyze changes in visual analogue scale(VAS)scores,neck disability index(NDI),pressure pain threshold(PPT),Borden value,cervical lordosis,T1 slope,cervical slope,and thoracic inlet angle before and after using the pillow.Results Finite element analysis indicated that the maximum stress on vertebral bodies increased by 64.35%and the maximum stress on cartilage tissues by 5.09%after using the pillow.The Borden value improved by 45.75%.Clinical studies showed a significant reduction in VAS scores,NDI,and PPT after treatment(P<0.05),while PPT,Borden value,cervical lordosis,T1 slope,and thoracic inlet angle significantly increased(P<0.05).Conclusions The 3D-printed personalized cervical correction pillow is safe and effective in alleviating neck pain and improving cervical curvature,and it provides a new and effective non-surgical treatment option for cervical spondylotic radiculopathy,with significant clinical implications.

Result Analysis
Print
Save
E-mail