1.Robot system-assisted versus freehand screw revision for ankylosing spondylitis with lower cervical fractures: a multicenter retrospective study
Shuai LI ; Jiaojiao BAI ; Baorong HE ; Yanzheng GAO ; Wei MEI ; Xinyu LIU ; Yue ZHU ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhigang ZHAO ; Yunfei HUANG ; Jinpeng DU ; Mingzhe FENG ; Ningbo CHEN ; Yansheng HUANG ; Xuefang ZHANG ; Zhen CHANG
Chinese Journal of Trauma 2025;41(5):440-448
Objective:To compare the efficacy of robot system-assisted versus freehand screw revision for ankylosing spondylitis (AS) with lower cervical fractures.Methods:A multicenter retrospective cohort study was conducted to analyze the clinical data of 57 patients with AS combined with lower cervical fractures admitted to Honghui Hospital Affiliated to Xi'an Jiaotong University School of Medicine, Henan Provincial People's Hospital, Zhengzhou Orthopedic Hospital, and Qilu Hospital of Shandong University, including 46 males and 11 females, aged 38-77 years [(65.4±9.5)years]. Injury segments involved C 3 in 7 patients, C 4 in 13, C 5 in 25, C 6 in 10, and C 7 in 2. All the patients underwent revision surgery, among whom, 22 patients were treated with robot system-assisted cervical pedicle screw placement (robot nailing group, with 190 screws), and 35 with freehand cervical pedicle screw placement (freehand nailing group, with 300 screws). The operative duration, intraoperative bleeding volume, frequency of intraoperative fluoroscopy, incision length, and length of hospital stay of the two groups were compared; the time of single nscrew insertion, the number of single nail revisions, the distance between screws and the anterior cortex, the accuracy of screw placement of grade 0 and grade 0+1 were recorded in the two groups. The visual analogue scale (VAS), Japanese Orthopedic Society (JOA) score, neck dysfunction index (NDI), American Spine Injury Association (ASIA) classification before operation, at 3 days, 3 months after operation and at the last follow-up were compared between the two groups. The complication rate was also noted. Results:All the patients were followed up for 12-16 months [(14.3±2.1)months]. The operative duration, intraoperative bleeding volume, and frequency of intraoperative fluoroscopy were (186.4±12.9)minutes, (486.1±68.6)ml, and (3.4±1.3)times in the robot nailing group, which were shorter or less than (206.7±14.4)minutes, (660.3±45.2)ml, and (13.5±3.6)times in the freehand nailing group ( P<0.01). The incision length was (9.4±2.4)cm in the robot nailing group, longer than (5.6±1.2)cm in the freehand nailing group ( P<0.01), and the length of hospital stay was (3.7±0.4)days, shorter than (4.4±1.4)days in the freehand nailing group ( P<0.01). The length of single nail insertion, the number of single nail revision, and the distance between the screws and the front cortex were (6.5±0.4)minutes, (1.1±0.1)times, and (3.5±1.3)mm in the robot nailing group, which were shorter or less than (11.6±0.2)minutes, (1.5±0.2)times, and (12.4±4.7)mm in the freehand nailing group ( P<0.01). The accuracy of the screw placement in the robot nailing group was 90.0% (171/190) and 95.8% (182/190) with level 0 and 0+1 screws, better than 80.0% (240/300) and 89.0% (267/300) in the freehand nailing group ( P<0.05). There was no significant difference in VAS, JOA score, NDI, or ASIA grading between the two groups before operation ( P>0.05). The VAS, JOA, and NDI scores at 3 days after operation were (3.1±0.6)points, (12.1±1.2)points, and (15.6±2.9)points, respectively in the robot nailing group, which were better than (5.0±1.4)points, (11.3±1.1)points and (22.5±3.7)points, respectively in the freehand nailing group ( P<0.05). No statistically significant difference was observed in the ASIA grade between the two groups at 3 days after operation ( P>0.05). There were no significant differences in VAS, JOA, NDI scores, or ASIA grading between the two groups at 3 months after operation and at the last follow-up ( P>0.05). Compared with those before operation, the VAS, JOA, NDI scores, and ASIA grading were significantly improved at 3 days, 3 months after operation and at the last follow-up in the two groups, which were further improved with the passage of time. Two patients in the robot nailing group had pneumonia, with a complication rate of 9% (2/22), while 2 patients in the freehand nailing group had dural sac rupture and cerebrospinal fluid leakage and 3 had lung infection after operation, with a complication rate of 14% (5/35) ( P<0.05). Conclusion:Compared with freehand nailing, the robot system-assisted nailing revision for AS with lower cervical fracture has more advantages in terms of the operative duration, length of hospital stay, intraoperative bleeding volume, frequency of intraoperative fluoroscopy nailing speed and accuracy, screw holding force, early pain relief, function restoration, and complication rate, despite longer surgical incision.
2.Comparative efficacy of laminoplasty via intermuscular approach or posterior midline approach for cervical spinal cord injury without radiographic abnormality: a multi-center retrospective study
Yunfei HUANG ; Shuai LI ; Jinpeng DU ; Baorong HE ; Yanzheng GAO ; Wei MEI ; Shibao LU ; Zhigan ZHAO ; Liang YAN ; Xiaobin YANG ; Yuan HE ; Zhen CHANG
Chinese Journal of Trauma 2025;41(7):635-644
Objective:To compare the efficacy of laminoplasty via the intermuscular approach or posterior midline approach for treating spinal cord injury without radiographic abnormality (SCIWORA).Methods:A multi-center retrospective cohort study was conducted to analyze the clinical data of 135 patients with SCIWORA admitted to Honghui Hospital Affiliated to Xi'an Jiaotong University School of Medicine, Xi'an No.5 Hospital, Henan Provincial People's Hospital, Zhengzhou Orthopedic Hospital, Xuanwu Hospital of Capital Medical University from February 2021 to June 2023, including 75 males and 60 females, aged 35-78 years [(55.3±8.1)years]. The injury segments involved C 3-C 6. All the patients underwent posterior cervical open-door laminoplasty, among whom 70 patients were treated via the intermuscular approach (intermuscular group) and 65 via the posterior midline approach (posterior midline group). The operation duration, intraoperative blood loss, postoperative drainage volume, and length of hospital stay were recorded. The visual analogue scale (VAS) score, Japanese Orthopedic Association (JOA) score, neck disability index (NDI), Barthel index, cervical Cobb angle, and cervical range of motion (ROM) were measured preoperatively, at 3, 6, 12 months postoperatively and at the final follow-up. The American Spinal Injury Association (ASIA) scale was evaluated preoperatively, at 3, 12 months postoperatively and at the final follow-up. The postoperative complication rate was recorded as well. Results:All the patients were followed up for 15-19 months [(16.3±1.6)months]. The operation duration, intraoperative blood loss, postoperative drainage and length of hospital stay were (125.0±23.0)minutes, (210.4±34.8)ml, and (165.3±23.7)ml, and (5.3±0.1)days in the intermuscular group, which were significantly shorter or less than (168.0±27.6)minutes, (260.2±45.3)ml, (196.4±31.6)ml, and (6.4±0.2)days in the posterior midline group ( P<0.01). The preoperative VAS score, JOA score, NDI and Barthel index showed no significant differences between the two groups ( P>0.05). The VAS score and JOA score also showed no significant differences between the two groups at 3, 6, 12 months postoperatively or at the final follow-up ( P>0.05). The NDI and Barthel index also showed no significant differences between the two groups at 3 months postoperatively ( P>0.05). At 6, 12 months postoperatively and at the final follow-up, the NDI were (15.4±2.5)points, (11.8±2.1)points and (8.6±1.5)points in the intermuscular group, significantly lower than (19.1±3.4)points, (14.3±2.4)points and (11.9±1.4)points in the posterior midline group ( P<0.01). At 6, 12 months postoperatively and at the final follow-up, the Barthel index were (71.4±6.2)points, (83.4±5.8)points and (89.2±7.1)points in the intermuscular group, significantly higher than (59.6±4.7)points, (74.2±3.9)points and (78.8±6.2)points in the posterior midline group ( P<0.01). Both groups showed significant improvements in VAS score, JOA score, NDI and Barthel index at 3, 6, 12 months postoperatively and at the final follow-up when compared to those preoperatively ( P<0.05). Among them, the VAS score, NDI and Barthel index were further improved over time ( P<0.05). Simultaneously, the JOA score was significantly improved at 6, 12 months postoperatively and at the last follow-up when compared to that at 3 months postoperatively ( P<0.05), with no significant difference at later time points between the two groups ( P>0.05). The preoperative cervical Cobb angle and ROM showed no significant differences between the two groups ( P>0.05). There was no significant difference in the Cobb angle between the two groups at 3, 6 or 12 months postoperatively ( P>0.05), while it was (13.6±2.4)° in the intermuscular group at the final follow-up, significantly larger than (10.4±2.8)° in the posterior midline group ( P<0.01). At 3, 6, 12 months postoperatively and at the final follow-up, the cervical ROM were (34.1±6.4)°, (32.6±7.3)°, (31.8±9.1)° and (29.6±8.7)° in the intermuscular group, significantly larger than (23.7±8.3)°, (22.3±7.8)°, (22.5±8.1)° and (20.6±9.3)° in the posterior midline group ( P<0.01). In the intermuscular group, the cervical Cobb angle showed no significant changes at 3, 6, 12 months postoperatively and at the final follow-up when compared to those preoperatively ( P>0.05). In the posterior midline group, the Cobb angles were significantly reduced at 3, 6, 12 months postoperatively and at the final follow-up when compared to those preoperatively ( P<0.05), showing significant decrease at 12 months postoperatively and at the final follow-up from those at 3, 6 months postoperatively ( P<0.05), no significant difference at 6 months postoperatively from that at 3 months postoperatively ( P>0.05), and significant decrease at the final follow-up from that at 12 months postoperatively ( P>0.05). In the intermuscular group, the cervical ROM were significantly improved at 3, 6, 12 months postoperatively and at the final follow-up when compared to those preoperatively and showed further improvement over time ( P<0.05). In the posterior midline group, the cervical ROM were significantly improved at 3, 6, 12 months postoperatively and at the final follow-up when compared to those preoperatively ( P<0.05), showing significant decreases at 6, 12 months postoperatively and at the final follow-up from that at 3 months postoperatively ( P<0.05), significant decreases at the final follow-up from those at 6, 12 months postoperatively ( P<0.05), and no significant difference at 12 months postoperatively from that at 6 months postoperatively ( P>0.05). The ASIA grades showed no significant difference between the two groups preoperatively, at 3, 12 months postoperatively and at the final follow-up ( P>0.05) , but were gradually improved over time in both groups ( P<0.05). The postoperative complication rate was 9%(6/70) in the intermuscular group, significantly lower than 48%(31/65) in the posterior midline group ( P<0.01). Conclusion:Compared to the posterior midline approach, the intermuscular approach for laminoplasty in patients with SCIWORA possesses advantages, including shorter operative time and length of hospital stay, reduced intraoperative blood loss and postoperative drainage, less postoperative neck disability, higher daily life quality, better long-term preservation of cervical lordosis and motion, and a lower complication rate.
3.Clinical application progress of 18F-FDG PET/CT dynamic imaging in lung cancer
Jinpeng ZHOU ; Wumener XIERAILI ; Fen DU ; Ying LIANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2025;45(1):48-52
18F-FDG PET/CT static imaging plays a crucial role in the diagnosis, staging, and efficacy assessment of lung cancer. Semi-quantitative analysis using metabolic parameters, such as SUV, provide essential metabolic information for clinical decision-making. However, SUV is influenced by patient factors, acquisition time, and reconstruction algorithms. Dynamic imaging allows continuous assessment of the metabolic changes in lesions over a specific period, using dynamic parameters like the net uptake rate constant for quantitative analysis. Dynamic imaging provides important complementary information to static imaging, offering more precise information for the diagnosis and treatment of lung cancer. This article focuses on the applications of dynamic imaging in the diagnosis of lung cancer, lymph node staging, evaluation of immunotherapy efficacy, and optimization of scanning protocols, providing a comprehensive review of the research progress of dynamic 18F-FDG PET/CT imaging in the management of lung cancer.
4.Chinese version of the Clinical Leadership Needs Analysis Instrument and its reliability and validity test
Mengqing DU ; Jinpeng XU ; Zhigang QIAN ; Qian WANG ; Yixin WANG ; Manyu ZHANG
Chinese Journal of Modern Nursing 2025;31(4):491-496
Objective:To translate the Clinical Leadership Needs Analysis Instrument (CLeeNA) into Chinese and to test its reliability and validity.Methods:The source scale was translated based on the Beaton translation model, and cultural debugging was completed through expert consultation and pre-surveys to form the Chinese version of CLeeNA. Convenience sampling was used to select 536 nurses from three Class Ⅲ Grade A hospitals in Anhui Province from August to December 2023 to conduct the survey and to verify the reliability and validity of the scale. A total of 536 questionnaires were distributed and 495 valid questionnaires were recovered, with an effective recovery rate of 92.351% (495/536) .Results:The Chinese version of CLeeNA contained 43 entries in 7 dimensions of self and team development, staff and care delivery, technology and care initiatives, financial and service management, leadership and clinical practice, patient safety and risk management, and standards of care. The content validity index at the item level ranged from 0.800 to 1.000, and the content validity index at the scale level was 0.953. Exploratory factor analysis extracted 7 common factors with a cumulative variance contribution rate of 82.098%. Confirmatory factor analysis showed that the model fit was acceptable. The total Cronbach's ɑ coefficient for the scale was 0.958, the folding coefficient was 0.898, and the retest reliability coefficient was 0.928.Conclusions:The Chinese version of CLeeNA has good reliability and validity, and can be used for measuring the clinical leadership needs of nurses.
5.Chinese version of the Clinical Leadership Needs Analysis Instrument and its reliability and validity test
Mengqing DU ; Jinpeng XU ; Zhigang QIAN ; Qian WANG ; Yixin WANG ; Manyu ZHANG
Chinese Journal of Modern Nursing 2025;31(4):491-496
Objective:To translate the Clinical Leadership Needs Analysis Instrument (CLeeNA) into Chinese and to test its reliability and validity.Methods:The source scale was translated based on the Beaton translation model, and cultural debugging was completed through expert consultation and pre-surveys to form the Chinese version of CLeeNA. Convenience sampling was used to select 536 nurses from three Class Ⅲ Grade A hospitals in Anhui Province from August to December 2023 to conduct the survey and to verify the reliability and validity of the scale. A total of 536 questionnaires were distributed and 495 valid questionnaires were recovered, with an effective recovery rate of 92.351% (495/536) .Results:The Chinese version of CLeeNA contained 43 entries in 7 dimensions of self and team development, staff and care delivery, technology and care initiatives, financial and service management, leadership and clinical practice, patient safety and risk management, and standards of care. The content validity index at the item level ranged from 0.800 to 1.000, and the content validity index at the scale level was 0.953. Exploratory factor analysis extracted 7 common factors with a cumulative variance contribution rate of 82.098%. Confirmatory factor analysis showed that the model fit was acceptable. The total Cronbach's ɑ coefficient for the scale was 0.958, the folding coefficient was 0.898, and the retest reliability coefficient was 0.928.Conclusions:The Chinese version of CLeeNA has good reliability and validity, and can be used for measuring the clinical leadership needs of nurses.
6.Robot system-assisted versus freehand screw revision for ankylosing spondylitis with lower cervical fractures: a multicenter retrospective study
Shuai LI ; Jiaojiao BAI ; Baorong HE ; Yanzheng GAO ; Wei MEI ; Xinyu LIU ; Yue ZHU ; Qingda LI ; Yukuan LEI ; Lei ZHU ; Zhigang ZHAO ; Yunfei HUANG ; Jinpeng DU ; Mingzhe FENG ; Ningbo CHEN ; Yansheng HUANG ; Xuefang ZHANG ; Zhen CHANG
Chinese Journal of Trauma 2025;41(5):440-448
Objective:To compare the efficacy of robot system-assisted versus freehand screw revision for ankylosing spondylitis (AS) with lower cervical fractures.Methods:A multicenter retrospective cohort study was conducted to analyze the clinical data of 57 patients with AS combined with lower cervical fractures admitted to Honghui Hospital Affiliated to Xi'an Jiaotong University School of Medicine, Henan Provincial People's Hospital, Zhengzhou Orthopedic Hospital, and Qilu Hospital of Shandong University, including 46 males and 11 females, aged 38-77 years [(65.4±9.5)years]. Injury segments involved C 3 in 7 patients, C 4 in 13, C 5 in 25, C 6 in 10, and C 7 in 2. All the patients underwent revision surgery, among whom, 22 patients were treated with robot system-assisted cervical pedicle screw placement (robot nailing group, with 190 screws), and 35 with freehand cervical pedicle screw placement (freehand nailing group, with 300 screws). The operative duration, intraoperative bleeding volume, frequency of intraoperative fluoroscopy, incision length, and length of hospital stay of the two groups were compared; the time of single nscrew insertion, the number of single nail revisions, the distance between screws and the anterior cortex, the accuracy of screw placement of grade 0 and grade 0+1 were recorded in the two groups. The visual analogue scale (VAS), Japanese Orthopedic Society (JOA) score, neck dysfunction index (NDI), American Spine Injury Association (ASIA) classification before operation, at 3 days, 3 months after operation and at the last follow-up were compared between the two groups. The complication rate was also noted. Results:All the patients were followed up for 12-16 months [(14.3±2.1)months]. The operative duration, intraoperative bleeding volume, and frequency of intraoperative fluoroscopy were (186.4±12.9)minutes, (486.1±68.6)ml, and (3.4±1.3)times in the robot nailing group, which were shorter or less than (206.7±14.4)minutes, (660.3±45.2)ml, and (13.5±3.6)times in the freehand nailing group ( P<0.01). The incision length was (9.4±2.4)cm in the robot nailing group, longer than (5.6±1.2)cm in the freehand nailing group ( P<0.01), and the length of hospital stay was (3.7±0.4)days, shorter than (4.4±1.4)days in the freehand nailing group ( P<0.01). The length of single nail insertion, the number of single nail revision, and the distance between the screws and the front cortex were (6.5±0.4)minutes, (1.1±0.1)times, and (3.5±1.3)mm in the robot nailing group, which were shorter or less than (11.6±0.2)minutes, (1.5±0.2)times, and (12.4±4.7)mm in the freehand nailing group ( P<0.01). The accuracy of the screw placement in the robot nailing group was 90.0% (171/190) and 95.8% (182/190) with level 0 and 0+1 screws, better than 80.0% (240/300) and 89.0% (267/300) in the freehand nailing group ( P<0.05). There was no significant difference in VAS, JOA score, NDI, or ASIA grading between the two groups before operation ( P>0.05). The VAS, JOA, and NDI scores at 3 days after operation were (3.1±0.6)points, (12.1±1.2)points, and (15.6±2.9)points, respectively in the robot nailing group, which were better than (5.0±1.4)points, (11.3±1.1)points and (22.5±3.7)points, respectively in the freehand nailing group ( P<0.05). No statistically significant difference was observed in the ASIA grade between the two groups at 3 days after operation ( P>0.05). There were no significant differences in VAS, JOA, NDI scores, or ASIA grading between the two groups at 3 months after operation and at the last follow-up ( P>0.05). Compared with those before operation, the VAS, JOA, NDI scores, and ASIA grading were significantly improved at 3 days, 3 months after operation and at the last follow-up in the two groups, which were further improved with the passage of time. Two patients in the robot nailing group had pneumonia, with a complication rate of 9% (2/22), while 2 patients in the freehand nailing group had dural sac rupture and cerebrospinal fluid leakage and 3 had lung infection after operation, with a complication rate of 14% (5/35) ( P<0.05). Conclusion:Compared with freehand nailing, the robot system-assisted nailing revision for AS with lower cervical fracture has more advantages in terms of the operative duration, length of hospital stay, intraoperative bleeding volume, frequency of intraoperative fluoroscopy nailing speed and accuracy, screw holding force, early pain relief, function restoration, and complication rate, despite longer surgical incision.
7.Comparative efficacy of laminoplasty via intermuscular approach or posterior midline approach for cervical spinal cord injury without radiographic abnormality: a multi-center retrospective study
Yunfei HUANG ; Shuai LI ; Jinpeng DU ; Baorong HE ; Yanzheng GAO ; Wei MEI ; Shibao LU ; Zhigan ZHAO ; Liang YAN ; Xiaobin YANG ; Yuan HE ; Zhen CHANG
Chinese Journal of Trauma 2025;41(7):635-644
Objective:To compare the efficacy of laminoplasty via the intermuscular approach or posterior midline approach for treating spinal cord injury without radiographic abnormality (SCIWORA).Methods:A multi-center retrospective cohort study was conducted to analyze the clinical data of 135 patients with SCIWORA admitted to Honghui Hospital Affiliated to Xi'an Jiaotong University School of Medicine, Xi'an No.5 Hospital, Henan Provincial People's Hospital, Zhengzhou Orthopedic Hospital, Xuanwu Hospital of Capital Medical University from February 2021 to June 2023, including 75 males and 60 females, aged 35-78 years [(55.3±8.1)years]. The injury segments involved C 3-C 6. All the patients underwent posterior cervical open-door laminoplasty, among whom 70 patients were treated via the intermuscular approach (intermuscular group) and 65 via the posterior midline approach (posterior midline group). The operation duration, intraoperative blood loss, postoperative drainage volume, and length of hospital stay were recorded. The visual analogue scale (VAS) score, Japanese Orthopedic Association (JOA) score, neck disability index (NDI), Barthel index, cervical Cobb angle, and cervical range of motion (ROM) were measured preoperatively, at 3, 6, 12 months postoperatively and at the final follow-up. The American Spinal Injury Association (ASIA) scale was evaluated preoperatively, at 3, 12 months postoperatively and at the final follow-up. The postoperative complication rate was recorded as well. Results:All the patients were followed up for 15-19 months [(16.3±1.6)months]. The operation duration, intraoperative blood loss, postoperative drainage and length of hospital stay were (125.0±23.0)minutes, (210.4±34.8)ml, and (165.3±23.7)ml, and (5.3±0.1)days in the intermuscular group, which were significantly shorter or less than (168.0±27.6)minutes, (260.2±45.3)ml, (196.4±31.6)ml, and (6.4±0.2)days in the posterior midline group ( P<0.01). The preoperative VAS score, JOA score, NDI and Barthel index showed no significant differences between the two groups ( P>0.05). The VAS score and JOA score also showed no significant differences between the two groups at 3, 6, 12 months postoperatively or at the final follow-up ( P>0.05). The NDI and Barthel index also showed no significant differences between the two groups at 3 months postoperatively ( P>0.05). At 6, 12 months postoperatively and at the final follow-up, the NDI were (15.4±2.5)points, (11.8±2.1)points and (8.6±1.5)points in the intermuscular group, significantly lower than (19.1±3.4)points, (14.3±2.4)points and (11.9±1.4)points in the posterior midline group ( P<0.01). At 6, 12 months postoperatively and at the final follow-up, the Barthel index were (71.4±6.2)points, (83.4±5.8)points and (89.2±7.1)points in the intermuscular group, significantly higher than (59.6±4.7)points, (74.2±3.9)points and (78.8±6.2)points in the posterior midline group ( P<0.01). Both groups showed significant improvements in VAS score, JOA score, NDI and Barthel index at 3, 6, 12 months postoperatively and at the final follow-up when compared to those preoperatively ( P<0.05). Among them, the VAS score, NDI and Barthel index were further improved over time ( P<0.05). Simultaneously, the JOA score was significantly improved at 6, 12 months postoperatively and at the last follow-up when compared to that at 3 months postoperatively ( P<0.05), with no significant difference at later time points between the two groups ( P>0.05). The preoperative cervical Cobb angle and ROM showed no significant differences between the two groups ( P>0.05). There was no significant difference in the Cobb angle between the two groups at 3, 6 or 12 months postoperatively ( P>0.05), while it was (13.6±2.4)° in the intermuscular group at the final follow-up, significantly larger than (10.4±2.8)° in the posterior midline group ( P<0.01). At 3, 6, 12 months postoperatively and at the final follow-up, the cervical ROM were (34.1±6.4)°, (32.6±7.3)°, (31.8±9.1)° and (29.6±8.7)° in the intermuscular group, significantly larger than (23.7±8.3)°, (22.3±7.8)°, (22.5±8.1)° and (20.6±9.3)° in the posterior midline group ( P<0.01). In the intermuscular group, the cervical Cobb angle showed no significant changes at 3, 6, 12 months postoperatively and at the final follow-up when compared to those preoperatively ( P>0.05). In the posterior midline group, the Cobb angles were significantly reduced at 3, 6, 12 months postoperatively and at the final follow-up when compared to those preoperatively ( P<0.05), showing significant decrease at 12 months postoperatively and at the final follow-up from those at 3, 6 months postoperatively ( P<0.05), no significant difference at 6 months postoperatively from that at 3 months postoperatively ( P>0.05), and significant decrease at the final follow-up from that at 12 months postoperatively ( P>0.05). In the intermuscular group, the cervical ROM were significantly improved at 3, 6, 12 months postoperatively and at the final follow-up when compared to those preoperatively and showed further improvement over time ( P<0.05). In the posterior midline group, the cervical ROM were significantly improved at 3, 6, 12 months postoperatively and at the final follow-up when compared to those preoperatively ( P<0.05), showing significant decreases at 6, 12 months postoperatively and at the final follow-up from that at 3 months postoperatively ( P<0.05), significant decreases at the final follow-up from those at 6, 12 months postoperatively ( P<0.05), and no significant difference at 12 months postoperatively from that at 6 months postoperatively ( P>0.05). The ASIA grades showed no significant difference between the two groups preoperatively, at 3, 12 months postoperatively and at the final follow-up ( P>0.05) , but were gradually improved over time in both groups ( P<0.05). The postoperative complication rate was 9%(6/70) in the intermuscular group, significantly lower than 48%(31/65) in the posterior midline group ( P<0.01). Conclusion:Compared to the posterior midline approach, the intermuscular approach for laminoplasty in patients with SCIWORA possesses advantages, including shorter operative time and length of hospital stay, reduced intraoperative blood loss and postoperative drainage, less postoperative neck disability, higher daily life quality, better long-term preservation of cervical lordosis and motion, and a lower complication rate.
8.Clinical application progress of 18F-FDG PET/CT dynamic imaging in lung cancer
Jinpeng ZHOU ; Wumener XIERAILI ; Fen DU ; Ying LIANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2025;45(1):48-52
18F-FDG PET/CT static imaging plays a crucial role in the diagnosis, staging, and efficacy assessment of lung cancer. Semi-quantitative analysis using metabolic parameters, such as SUV, provide essential metabolic information for clinical decision-making. However, SUV is influenced by patient factors, acquisition time, and reconstruction algorithms. Dynamic imaging allows continuous assessment of the metabolic changes in lesions over a specific period, using dynamic parameters like the net uptake rate constant for quantitative analysis. Dynamic imaging provides important complementary information to static imaging, offering more precise information for the diagnosis and treatment of lung cancer. This article focuses on the applications of dynamic imaging in the diagnosis of lung cancer, lymph node staging, evaluation of immunotherapy efficacy, and optimization of scanning protocols, providing a comprehensive review of the research progress of dynamic 18F-FDG PET/CT imaging in the management of lung cancer.
9.Preliminary mining and analysis of ADE signal of ofatumumab
Xiaojuan YANG ; Qingwen ZHANG ; Xiaosa DU ; Jinpeng DONG ; Yiming HU ; Shudi WANG ; Yubin FENG
China Pharmacy 2024;35(17):2120-2125
OBJECTIVE To screen potential adverse drug event (ADE) signals for the treatment of multiple sclerosis (MS) with ofatumumab, and to provide reference for the safe use of drugs in clinical practice. METHODS Using “ofatumumab” and the trade name “Kesimpta” as the search keywords, adverse event (AE) reports related to ofatumumab included in FDA Adverse Event Reporting System database from January 2009 to December 2023 were screened, and their reason contained the “multiple sclerosis”; ADE signal mining and analysis were conducted by reporting odds ratio method and proportional reporting ratio method. RESULTS A total of 21 759 eligible AE reports were selected, involving 62 449 AE cases; 27 system organ classes included general diseases and various reactions at the site of administration (15 021 cases), neurological diseases (9 668 cases), infectious and invasive diseases (5 967 cases), injury, poisoning and surgical complications (4 952 cases), musculoskeletal and connective tissue disorders (4 647 cases). A total of 21 759 AE reports correspond to 606 ADE signals, including 234 ADE positive signals. A total of 107 ADE positive signals were not included in drug instruction of ofatumumab, including flu-like diseases, nasopharyngitis, cough, urinary tract infection, sore throat, insomnia, runny nose, anemia, hair loss, atrial fibrillation, and thrombocytopenia, etc. CONCLUSIONS In the process of using ofatumumab for MS, sufficient attention should be paid to ADE included in drug instructions. The ADE with strong signal strength screened in this study should also be paid special attention to, such as flu-like diseases, hemocytopenia, temperature intolerance, optic neuritis, and moyamoya disease. The increased risk of infection, cardiovascular disease, and potential damage to the respiratory and spiritual systems caused by ofatumumab can not be ignored.
10.Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults (version 2024)
Qingde WANG ; Yuan HE ; Bohua CHEN ; Tongwei CHU ; Jinpeng DU ; Jian DONG ; Haoyu FENG ; Shunwu FAN ; Shiqing FENG ; Yanzheng GAO ; Zhong GUAN ; Hua GUO ; Yong HAI ; Lijun HE ; Dianming JIANG ; Jianyuan JIANG ; Bin LIN ; Bin LIU ; Baoge LIU ; Chunde LI ; Fang LI ; Feng LI ; Guohua LYU ; Li LI ; Qi LIAO ; Weishi LI ; Xiaoguang LIU ; Hongjian LIU ; Yong LIU ; Zhongjun LIU ; Shibao LU ; Yong QIU ; Limin RONG ; Yong SHEN ; Huiyong SHEN ; Jun SHU ; Yueming SONG ; Tiansheng SUN ; Yan WANG ; Zhe WANG ; Zheng WANG ; Hong XIA ; Guoyong YIN ; Jinglong YAN ; Wen YUAN ; Zhaoming YE ; Jie ZHAO ; Jianguo ZHANG ; Yue ZHU ; Yingjie ZHOU ; Zhongmin ZHANG ; Wei MEI ; Dingjun HAO ; Baorong HE
Chinese Journal of Trauma 2024;40(2):97-106
Ankylosing spondylitis (AS) combined with lower cervical fracture is often categorized into unstable fracture, with a high incidence of neurological injury and a high rate of disability and morbidity. As factors such as shoulder occlusion may affect the accuracy of X-ray imaging diagnosis, it is often easily misdiagnosed at the primary diagnosis. Non-operative treatment has complications such as bone nonunion and the possibility of secondary neurological damage, while the timing, access and choice of surgical treatment are still controversial. Currently, there are no clinical practice guidelines for the treatment of AS combined with lower cervical fracture with or without dislocation. To this end, the Spinal Trauma Group of Orthopedics Branch of Chinese Medical Doctor Association organized experts to formulate Clinical guidelines for the treatment of ankylosing spondylitis combined with lower cervical fracture in adults ( version 2024) in accordance with the principles of evidence-based medicine, scientificity and practicality, in which 11 recommendations were put forward in terms of the diagnosis, imaging evaluation, typing and treatment, etc, to provide guidance for the diagnosis and treatment of AS combined with lower cervical fracture.

Result Analysis
Print
Save
E-mail