1.Hepatitis E virus infection among blood donors in Hangzhou
Ziyun DU ; Wenjun DENG ; Danxiao WU ; Jinhui LIU ; Jie DONG
Chinese Journal of Blood Transfusion 2025;38(1):19-25
[Objective] To investigate the infection and characteristics of hepatitis E virus among blood donors in Hangzhou. [Methods] A total of 5 075 blood samples of blood donors from Zhejiang Provincial Blood Center from September to November 2023 were collected, including 5 037 samples with normal ALT and 38 samples with elevated ALT (>50 U/L). Enzyme-linked immunosorbent assay (ELISA) was used to detect anti-HEV IgM, anti-HEV IgG and HEV-Ag. The Fisher test and Chi-square test were used to evaluate the difference in the reactivity rates of anti-HEV IgM and anti-HEV IgG among different levels of ALT. The distribution characteristics of HEV screening in blood donors were analyzed. Univariate and multivariate logistic regression were used to analyze the susceptibility factors of anti-HEV IgM and anti-HEV IgG seropositivity, and the anti-HEV IgM-reactive blood donors were followed up by telephone. [Results] The reactivity rates of anti-HEV IgM, anti-HEV IgG and HEV-Ag in 5 075 blood samples were 0.45%, 22.98% and 0%, respectively. There was no difference in the reactivity rates of anti-HEV IgM and anti-HEV IgG among different levels of ALT (P>0.05), and the results of univariate and multivariate logistic regression analysis showed that age was a risk factor for anti-HEV IgM and anti-HEV IgG reactivity in blood donors (P<0.05), while no difference in the reactivity rates of anti-HEV IgM and anti-HEV IgG among blood donors was noticed in gender, occupation and education level (P>0.05). [Conclusion] There is a potential risk of transfusion-transmitted HEV (TT-HEV) in Hangzhou, and a cost-effective HEV screening strategy needs to be established to continue regular HEV surveillance in Hangzhou to assess the risk of infection.
2.STAR Guideline Terminology (I): Planning and Launching
Zhewei LI ; Qianling SHI ; Hui LIU ; Xufei LUO ; Zijun WANG ; Jinhui TIAN ; Long GE ; Yaolong CHEN
Medical Journal of Peking Union Medical College Hospital 2025;16(1):216-223
To develop a guideline terminology system and promote its standardization, thereby enhancing medical staff's accurate understanding and correct application of guidelines. A systematic search was conducted for guideline development manuals and method ological literature (as of October 25, 2024). After screening, relevant terms from the guideline planning and launching stages were extracted and standardized. The term list and definitions were finalized through discussion and evaluation at a consensus conference. A total of 36 guideline manuals and 14 method ological articles were included, and 27 core terms were identified. The standardization of guideline terminology is essential for improving guideline quality, facilitating interdisciplinary communication, and enhancing other related aspects. It is recommended that efforts to advance the standardization and continuous updating of the terminology system should be prioritized in the future to support the high-quality development of guidelines.
3.Monitoring results of mosquito-ovitraps placed in different orientations in multi-storey residential areas
Caixiong LIU ; Bin GE ; Haibing ZHANG ; Lin WANG ; Tao YANG ; Yujiao WEI ; Haiying XIE ; Yu ZHANG ; Hongxia LIU ; Juntao SHEN
Shanghai Journal of Preventive Medicine 2025;37(2):109-113
ObjectiveTo find out whether there is any difference in the monitoring results of mosq-ovitraps placed in different orientations in multi-storey residential areas, so as to provide a scientific basis for routine and emergency monitoring of Aedes albopictus with mosq-ovitraps in residential areas. MethodsFrom July 6th to October 26th 2023, one mosquito ovitrap was set up in each of the 4 orientations of east, south, west and north around the buildings in a multi-storey residential area in Jinhui Town, Fengxian District, Shanghai. Data was collected and recorded 72 hours after placement. The chi-square test was used to compare the mosquito ovitrap indices (MOIs) of two independent samples, and the Kruskal⁃Wallis H test was used to compare the MOIs of multiple independent samples. ResultsAfter 16 weeks of surveillance, 997 mosquito ovitraps were recovered, of which 211 were positive, with the mosquito ovitrap index (MOI) of 21.16% and the Aedes albopictus density index of 1.03 mosquitoes·ovitrap-1. The MOIs were higher in September (24.22%) and October (23.96%), and the MOIs in the west, south and north within the two months were all above 20.00%. From July to October, the MOIs in the east, west, south and north were 20.70%, 22.20%, 25.50% and 16.20%, respectively, and the difference in MOIs among the 4 orientations was not statistically significant (χ2=6.647, P=0.084). Stratified analysis by month showed that in August, the south side of the multi-storey residential areas had the highest MOI (31.30%), the north side had the lowest MOI (1.30%), and there was a statistically significant difference in MOI in the east, west, south and north (χ2=25.986, P<0.001). In October, the MOI in the west was the highest (33.30%) and the MOI in the east was the lowest (6.30%), the difference in MOIs of the 4 orientations was statistically significant (χ2=12.007, P=0.007). The MOIs in the south side of the building in the outskirts of the residential area from the 1st week in July to the 4th week in October was lower (19.20%) than that in the south side of the inner building (31.70%), and the difference in MOI was statistically significant (χ2=5.118, P=0.024). ConclusionThe study of MOI in different orientations in a multi-storey residential area is a preliminary exploration based on field work, and the results show that there is a difference in MOIs in different orientations during the peak breeding period of mosquitoes. Further indicators such as temperature, humidity and wind speed in different orientations can be collected to explore the influencing factors of MOIs.
4.Influence evaluation of pharmaceutical quality control on medication therapy management services by the ECHO model
Kun LIU ; Huanhuan JIANG ; Yushuang LI ; Yan HUANG ; Qianying ZHANG ; Dong CHEN ; Xiulin GU ; Jinhui FENG ; Zijian WANG ; Yunfei CHEN ; Yajuan QI ; Yanlei GE ; Aishuang FU
China Pharmacy 2025;36(9):1123-1128
OBJECTIVE To evaluate the influence of pharmaceutical quality control on the efficiency and outcomes of standardized medication therapy management (MTM) services for patients with coronary heart disease by using Economic, Clinical and Humanistic Outcomes (ECHO) model. METHODS This study collected case data of coronary heart disease patients who received MTM services during January-March 2023 (pre-quality control implementation group, n=96) and June-August 2023 (post-quality control implementation group, n=164). Using propensity score matching analysis, 80 patients were selected from each group. The study subsequently compared the economic, clinical, and humanistic outcome indicators of pharmaceutical services between the two matched groups. RESULTS There were no statistically significant differences in baseline data between the two groups after matching (P>0.05). Compared with pre-quality control implementation group, the daily treatment cost (16.26 yuan vs. 24.40 yuan, P<0.001), cost-effectiveness ratio [23.12 yuan/quality-adjusted life year (QALY) vs. 32.32 yuan/QALY, P<0.001], and the incidence of general adverse drug reactions (2.50% vs. 10.00%, P=0.049) of post-quality control implementation group were decreased significantly; the utility value of the EuroQol Five-Dimensional Questionnaire (0.74± 0.06 vs. 0.71±0.07, P=0.003), the reduction in the number of medication related problems (1.0 vs. 0.5, P<0.001), the medication adherence score ([ 6.32±0.48) points vs. (6.10±0.37) points, P=0.001], and the satisfaction score ([ 92.56±1.52) points vs. (91.95±1.56) points, P=0.013] all showed significant improvements. Neither group experienced serious adverse drug reactions. There was no statistically significant difference in the incidence of new adverse reactions between the two groups (1.25% vs. 3.75%, P=0.310). CONCLUSIONS Pharmaceutical quality control can improve the quality of pharmaceutical care, and the ECHO model can quantitatively evaluate the effect of MTM services, making pharmaceutical care better priced and more adaptable to social needs, thus being worthy of promotion.
5.STAR Guideline Terminology(Ⅱ): Clinical Question Formulation, Evidence Retrieval and Appraisal, and Recommendation Development
Di ZHU ; Haodong LI ; Zijun WANG ; Qianling SHI ; Hui LIU ; Yishan QIN ; Yuanyuan YAO ; Zhewei LI ; Hongfeng HE ; Jinhui TIAN ; Long GE ; Yaolong CHEN ;
Medical Journal of Peking Union Medical College Hospital 2025;16(3):756-764
To introduce and analyze guideline terminology related to clinical question formulation, evidence retrieval and appraisal, and recommendation development. A systematic search was conducted in guideline development manuals and relevant methodological literature, covering publications up to October 25, 2024. Terminology related to the three aforementioned stages of related to guideline development was extracted from the included literature, standardized, and refined through consensus meetings to finalize a comprehensive terminology list and definitions. A total of 30 guideline development manuals and 15 methodological articles were included, and 23 core terms were identified. It is recommended to develop a standardized and scientifically sound guideline terminology system with unified naming, clear definitions, and alignment with the linguistic environment and usage habits in China. At the same time, it is essential to strengthen terminology training for both guideline developers and users based on this system, in order to deepen their correct understanding and proper application of guideline terminology.
6.Predictive value of ultrasound radiomics models for benign and malignant BI-RADS 4 breast lesions
Qiao ZOU ; Jinhui LIU ; Xiaoling LENG ; Tuerhong ZUMURETI ; Xiwen FAN
Chinese Journal of Radiological Health 2025;34(2):179-185
Objective To evaluate the efficiency of intra-tumor and peri-tumor ultrasound radiomics models based on machine learning algorithms for predicting benign and malignant Breast Imaging Reporting and Data System (BI-RADS) 4 breast lesions, and provide insights into early diagnosis of breast cancer. Methods A retrospective analysis was conducted based on the medical records of 450 female patients who underwent breast ultrasound examination in the Affiliated Cancer Hospital of Xinjiang Medical University from June 2020 to April 2022. The patients were divided into the benign (n = 199) and malignant (n = 195) groups according to pathological examination, and randomized into the training (n = 275) and validation (n = 119) sets at a ratio of 7∶3. Radiomics features were extracted and screened. Intra-tumor, peri-tumor, and intra-tumor + peri-tumor ultrasound radiomics models were constructed based on three machine learning algorithms, including logistic regression (LR), support vector machine (SVM), and multi-layer perceptron (MLP). Receiver operating characteristics (ROC) curves, calibration curves, and decision curves were plotted to evaluate the efficacy of the radiomics models for prediction of benign and malignant breast lesions. Results A total of 17 intra-tumor, 16 peri-tumor, and 17 intra-tumor + peri-tumor radiomics features were selected for model construction. Based on LR, MLP, and SVM algorithms, the intra-tumor + peri-tumor radiomics models showed higher predictive efficacy than intra-tumor and peri-tumor radiomics models. The predictive efficacy of intra-tumor, peri-tumor, and intra-tumor + peri-tumor radiomics models were higher based on the SVM algorithm than based on LR and MLP algorithms. For the intra-tumor radiomics model based on the SVM algorithm, the area under the ROC curve (AUC), accuracy, sensitivity, and a specificity were 0.909, 0.851, 0.860, and 0.842, respectively, in the training set and 0.866, 0.832, 0.847, and 0.817, respectively, in the validation set. For the peri-tumor radiomics model based on the SVM algorithm, these values were 0.899, 0.855, 0.882, and 0.827, respectively, in the training set and 0.844, 0.815, 0.847, and 0.783, respectively, in the validation set. For the intra-tumor + peri-tumor radiomics model based on the SVM algorithm, these values were 0.943, 0.876, 0.860, and 0.892, respectively, in the training set and 0.881, 0.849, 0.915, and 0.783, respectively, in the validation set. Conclusion The intra-tumor and peri-tumor ultrasound radiomics models based on machine learning algorithms are highly valuable for prediction of benign and malignant BI-RADS 4 breast lesions. The intra-tumor + peri-tumor ultrasound radiomics model based on the SVM algorithm has the optimal efficacy for prediction of benign and malignant BI-RADS 4 breast lesions.
7.Application,research hotspots,and shortcomings of degradable zinc-based alloys in bone defect repair and reconstruction
Haoyang LIU ; Qiang XIE ; Mengran SHEN ; Yansong REN ; Jinhui MA ; Bailiang WANG ; Debo YUE ; Weiguo WANG
Chinese Journal of Tissue Engineering Research 2025;29(4):839-845
BACKGROUND:Zinc-based alloy medical implant materials have excellent mechanical properties,complete degradability and good biocompatibility,and are mainly used in orthopedic implants,cardiovascular stents,bile duct stents,tracheal stents,nerve catheters,etc. OBJECTIVE:To review the research progress of biodegradable zinc-based alloys in bone defect repair and prospect the promising research direction and achievements of zinc-based materials. METHODS:After searching PubMed,Web of Science,WanFang Data,and CNKI databases from the establishment of the database to June 2023,various relevant articles on biodegradable zinc-based alloys for bone implant material research were collected.The basic characteristics of biodegradable zinc based alloys were summarized,and the role of zinc-based alloys in promoting bone tissue repair was sorted and summarized.The current research hotspots and shortcomings were discussed. RESULTS AND CONCLUSION:(1)Zinc-based alloys have good biocompatibility.Using zinc-based alloys as the matrix material,with the help of scaffold structure construction technology and coating optimization process,the bone conductivity of zinc-based alloys will be effectively improved,and their degradation products will have efficient bone induction to regulate the gene expression of osteoblasts and osteoclasts,thereby promoting the repair and reconstruction of bone defects.(2)However,in the research on optimizing zinc-based alloys,the coating process is relatively insufficient,and additive loading technology is still lacking.(3)Zinc-based alloys have excellent mechanical and biological properties.Through special processes,their bone conductivity and osteoinductivity can be increased to effectively improve their ability to promote bone repair and reconstruction,and it is expected to further achieve the development of personalized transplant materials.Further research and development are needed to optimize the integration of coating and additive loading technologies into zinc-based alloys.
8.Enhancing Disciplinary Development Through Journal Columns: Taking the "Clinical Practice Guidelines"Column in Medical Journal of Peking Union Medical College Hospital as an Example
Meihua WU ; Hui LIU ; Qi ZHOU ; Qianling SHI ; Na LI ; Yule LI ; Xiaoqing LIU ; Kehu YANG ; Jinhui TIAN ; Long GE ; Bin MA ; Xiuxia LI ; Xuping SONG ; Xiaohui WANG ; Yaolong CHEN
Medical Journal of Peking Union Medical College Hospital 2025;16(5):1315-1324
To explore the role of the "Clinical Practice Guidelines" column and others in the We collected papers published by the Lanzhou University Evidence-Based Medicine Center team in the "Clinical Practice Guidelines" column and others from 2018 to 2025. These publications were analyzed across multiple dimensions, including authorship and institutional affiliations, citation metrics, and research themes and content. A total of 59 papers were included in the analysis, with authors representing 70 domestie and international research institutions. The cumulative citation count was 639, with the highest single-paper citation frequency reaching 101. The average citation per paper was 10.8, and total downloads exceeded 30 000. The content focused on key themes such as guideline terminology, development methodology, guideline evaluation, and dissemination and implementation. The evolution of research topics progressed from critiques of common misconceptions and hot topies in the field to multidimensional evaluations of thecurrent state of Chinese guidelines, culminating in the fommulation of industry standards for guidelines. These contributions have provided critical references for translating guideline theory into practice in China and have garnered widespread attention and discussion among scholars in the field. The "Clinical Practice Guidelines" column and others in the
9.ResNet-Vision Transformer based MRI-endoscopy fusion model for predicting treatment response to neoadjuvant chemoradiotherapy in locally advanced rectal cancer: A multicenter study.
Junhao ZHANG ; Ruiqing LIU ; Di HAO ; Guangye TIAN ; Shiwei ZHANG ; Sen ZHANG ; Yitong ZANG ; Kai PANG ; Xuhua HU ; Keyu REN ; Mingjuan CUI ; Shuhao LIU ; Jinhui WU ; Quan WANG ; Bo FENG ; Weidong TONG ; Yingchi YANG ; Guiying WANG ; Yun LU
Chinese Medical Journal 2025;138(21):2793-2803
BACKGROUND:
Neoadjuvant chemoradiotherapy followed by radical surgery has been a common practice for patients with locally advanced rectal cancer, but the response rate varies among patients. This study aimed to develop a ResNet-Vision Transformer based magnetic resonance imaging (MRI)-endoscopy fusion model to precisely predict treatment response and provide personalized treatment.
METHODS:
In this multicenter study, 366 eligible patients who had undergone neoadjuvant chemoradiotherapy followed by radical surgery at eight Chinese tertiary hospitals between January 2017 and June 2024 were recruited, with 2928 pretreatment colonic endoscopic images and 366 pelvic MRI images. An MRI-endoscopy fusion model was constructed based on the ResNet backbone and Transformer network using pretreatment MRI and endoscopic images. Treatment response was defined as good response or non-good response based on the tumor regression grade. The Delong test and the Hanley-McNeil test were utilized to compare prediction performance among different models and different subgroups, respectively. The predictive performance of the MRI-endoscopy fusion model was comprehensively validated in the test sets and was further compared to that of the single-modal MRI model and single-modal endoscopy model.
RESULTS:
The MRI-endoscopy fusion model demonstrated favorable prediction performance. In the internal validation set, the area under the curve (AUC) and accuracy were 0.852 (95% confidence interval [CI]: 0.744-0.940) and 0.737 (95% CI: 0.712-0.844), respectively. Moreover, the AUC and accuracy reached 0.769 (95% CI: 0.678-0.861) and 0.729 (95% CI: 0.628-0.821), respectively, in the external test set. In addition, the MRI-endoscopy fusion model outperformed the single-modal MRI model (AUC: 0.692 [95% CI: 0.609-0.783], accuracy: 0.659 [95% CI: 0.565-0.775]) and the single-modal endoscopy model (AUC: 0.720 [95% CI: 0.617-0.823], accuracy: 0.713 [95% CI: 0.612-0.809]) in the external test set.
CONCLUSION
The MRI-endoscopy fusion model based on ResNet-Vision Transformer achieved favorable performance in predicting treatment response to neoadjuvant chemoradiotherapy and holds tremendous potential for enabling personalized treatment regimens for locally advanced rectal cancer patients.
Humans
;
Rectal Neoplasms/diagnostic imaging*
;
Magnetic Resonance Imaging/methods*
;
Male
;
Female
;
Middle Aged
;
Neoadjuvant Therapy/methods*
;
Aged
;
Adult
;
Chemoradiotherapy/methods*
;
Endoscopy/methods*
;
Treatment Outcome

Result Analysis
Print
Save
E-mail