1.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
2.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
3.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
4.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
5.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
6.The Life Functioning Scale: A Measurement Tool Developed to Assess the Physical Functioning Abilities of Community-Dwelling Adults Aged 50 Years or Older
Yunhwan LEE ; Eunsaem KIM ; Jihye YUN ; Jaewon CHOI ; Jinhee KIM ; Chang Won WON ; Miji KIM ; Soongnang JANG ; Kyungwon OH ; Jihee KIM
Annals of Geriatric Medicine and Research 2024;28(4):410-418
Background:
This study aimed to develop an instrument for assessing physical functioning among adults aged 50 years or older living in the community.
Methods:
Based on a review of various national health surveys and cohort studies, a 144-item bank was constructed for assessing physical functioning. Focus group interviews were conducted among adults aged 50 years or older to investigate their level of understanding of 60 selected items, followed by a pretest of the items on a nationally representative sample (n=508). The final 25-item questionnaire was tested on an independent sample (n=259) for validity and reliability based on classical test and item response theories. Predictive validity at the 6-month follow-up was tested in a separate sample (n=263).
Results:
The newly developed Life Functioning (LF) scale assessed the dimensions of functional limitations, disabilities, and social activities. The scale satisfied a one-dimensionality assumption with good item fit and demonstrated criterion validity, construct validity, high internal consistency (Cronbach’s alpha=0.93), and test-retest reliability (intra-class correlation coefficient=0.84; 95% confidence interval, 0.76–0.89). The LF scale comprised 25 items with a total score ranging from 0 to 100. Higher scores indicated higher levels of functioning. The LF score was significantly associated with the Physical Functioning score at 6 months.
Conclusion
The LF scale was developed to assess the physical functioning of people in their late midlife or older. Future studies should test the instrument on a national sample and evaluate its application in diverse population subgroups.
7.The Life Functioning Scale: A Measurement Tool Developed to Assess the Physical Functioning Abilities of Community-Dwelling Adults Aged 50 Years or Older
Yunhwan LEE ; Eunsaem KIM ; Jihye YUN ; Jaewon CHOI ; Jinhee KIM ; Chang Won WON ; Miji KIM ; Soongnang JANG ; Kyungwon OH ; Jihee KIM
Annals of Geriatric Medicine and Research 2024;28(4):410-418
Background:
This study aimed to develop an instrument for assessing physical functioning among adults aged 50 years or older living in the community.
Methods:
Based on a review of various national health surveys and cohort studies, a 144-item bank was constructed for assessing physical functioning. Focus group interviews were conducted among adults aged 50 years or older to investigate their level of understanding of 60 selected items, followed by a pretest of the items on a nationally representative sample (n=508). The final 25-item questionnaire was tested on an independent sample (n=259) for validity and reliability based on classical test and item response theories. Predictive validity at the 6-month follow-up was tested in a separate sample (n=263).
Results:
The newly developed Life Functioning (LF) scale assessed the dimensions of functional limitations, disabilities, and social activities. The scale satisfied a one-dimensionality assumption with good item fit and demonstrated criterion validity, construct validity, high internal consistency (Cronbach’s alpha=0.93), and test-retest reliability (intra-class correlation coefficient=0.84; 95% confidence interval, 0.76–0.89). The LF scale comprised 25 items with a total score ranging from 0 to 100. Higher scores indicated higher levels of functioning. The LF score was significantly associated with the Physical Functioning score at 6 months.
Conclusion
The LF scale was developed to assess the physical functioning of people in their late midlife or older. Future studies should test the instrument on a national sample and evaluate its application in diverse population subgroups.
8.The Life Functioning Scale: A Measurement Tool Developed to Assess the Physical Functioning Abilities of Community-Dwelling Adults Aged 50 Years or Older
Yunhwan LEE ; Eunsaem KIM ; Jihye YUN ; Jaewon CHOI ; Jinhee KIM ; Chang Won WON ; Miji KIM ; Soongnang JANG ; Kyungwon OH ; Jihee KIM
Annals of Geriatric Medicine and Research 2024;28(4):410-418
Background:
This study aimed to develop an instrument for assessing physical functioning among adults aged 50 years or older living in the community.
Methods:
Based on a review of various national health surveys and cohort studies, a 144-item bank was constructed for assessing physical functioning. Focus group interviews were conducted among adults aged 50 years or older to investigate their level of understanding of 60 selected items, followed by a pretest of the items on a nationally representative sample (n=508). The final 25-item questionnaire was tested on an independent sample (n=259) for validity and reliability based on classical test and item response theories. Predictive validity at the 6-month follow-up was tested in a separate sample (n=263).
Results:
The newly developed Life Functioning (LF) scale assessed the dimensions of functional limitations, disabilities, and social activities. The scale satisfied a one-dimensionality assumption with good item fit and demonstrated criterion validity, construct validity, high internal consistency (Cronbach’s alpha=0.93), and test-retest reliability (intra-class correlation coefficient=0.84; 95% confidence interval, 0.76–0.89). The LF scale comprised 25 items with a total score ranging from 0 to 100. Higher scores indicated higher levels of functioning. The LF score was significantly associated with the Physical Functioning score at 6 months.
Conclusion
The LF scale was developed to assess the physical functioning of people in their late midlife or older. Future studies should test the instrument on a national sample and evaluate its application in diverse population subgroups.
9.Investigation of Working Conditions and Health Status in Platform Workers in the Republic of Korea
Hyoungseob YOO ; Munyoung YANG ; Ji-Hun SONG ; Jin-Ha YOON ; Wanhyung LEE ; Jinhee JANG ; Minjoo YOON ; Mo-Yeol KANG
Safety and Health at Work 2024;15(1):17-23
Background:
The present study aimed to analyze several aspects of the working conditions and health status of platform workers in the Republic of Korea, such as ergonomic and emotional hazards. We also compared the health status of the platform workers with that of the general population.
Methods:
A total of 1,000 platform workers participated in this survey from August 7 to August 17, 2022. The participants included 400 designated drivers, 400 food-delivery drivers, and 200 housekeeping managers. A face-to-face survey with a structured questionnaire was conducted by researchers who had received specific instructions. The focus of the survey extended to the work environment, encompassing factors such as workplace violence, as well as physical, chemical, and ergonomic hazards. Health-related data for the previous year were also collected, covering a range of issues such as hearing problems, skin problems, musculoskeletal symptoms, headaches, injuries, mental health issues, and digestive problems. Subsequently, we compared the health symptom data of the responders with those of the general population in the Republic of Korea.
Results:
Platform workers, including designated drivers, food-delivery drivers, and housekeeping managers, existed in the blind spot of social insurance, facing frequent exposure to physical and chemical hazards, ergonomic risk factors, and direct or indirect violence. The prevalence of health problems, including musculoskeletal symptoms, general fatigue, and depressive symptoms, in each occupational group was statistically higher than that in the general population after standardization for age and gender.
Conclusion
The results revealed unfavorable working environment and inferior occupational health of platform workers compared with those of the general population.
10.Quantitative Susceptibility Mapping of Oxygen Metabolism: A Feasibility Study Utilizing a Large-Scale Clinical Dataset
Woojin CHUNG ; Jinhee JANG ; Yoonho NAM
Investigative Magnetic Resonance Imaging 2023;27(4):221-225
Purpose:
The aim of the present study was to investigate the potential utility of the magnetic susceptibility-based assessment of cerebral oxygen metabolism with a dataset from a memory clinic.
Materials and Methods:
We collected and processed three-dimensional gradient-recalled echo phase data of 290 participants. To analyze oxygen metabolism, quantitative susceptibility mapping was performed for two major veins (superior sagittal sinus and straight sinus), and the venous oxygen saturation was estimated.
Results:
The estimated venous oxygen saturations of the two major veins were positively correlated with the clinical and volumetric measurements. They did not differ with the clinical diagnosis or clinical dementia rating. The values of the superior sagittal sinus were associated with the presence of the apolipoprotein E type 4 allele, when considering age, sex, and their interactions.
Conclusion
The results demonstrate that quantitative susceptibility mapping of clinically available three-dimensional susceptibility-weighted imaging sequences in a large-scale clinical dataset can estimate cerebral oxygen metabolism.

Result Analysis