1.Risk Factors of Complications in Patients With Persistent or Long-Standing Persistent Atrial Fibrillation/Atrial Flutter Who Underwent Electrical Cardioversion:A Multicenter Cardioversion Registry
Ki-Hun KIM ; Junbeom PARK ; Donghwan KU ; Jino PARK ; Seunghwan KIM ; Dong-Kie KIM ; Doo-Il KIM ; Sun Gyu CHOI ; Pil-Sung YANG ; Ju Youn KIM ; Jaemin SHIM ; Jinhee AHN ; Sung Ho LEE ; Sung Il IM ; Hong Euy LIM
Journal of Korean Medical Science 2026;41(1):e19-
Background:
Identifying the risks related to the complications of electrical cardioversion (ECV) can alert the determinaton of rhythm control in patients with atrial fibrillation (AF).
Methods:
We retrospectively reviewed 1,058 patients who underwent ECV for persistent or long-standing persistent AF/atrial flutter (AFL) from multiple centers. Patients were classified into the no-complication (1,023 patients) and complication (35 patients) groups based on the following major complications: stroke and/or systemic embolism (SSE), myocardial infarction, major bleeding, implantation of cardiac implantable electronic devices, ventricular tachycardia/fibrillation, and death at 1 year follow-up after ECV.
Results:
Compared with the no-complication group, the complication group exhibited a higher proportion of female patients (37% vs. 22%), as well as a higher proportion of patients with older age (67 ± 11 vs. 61 ± 10 years), diabetes mellitus (DM) (49% vs. 24%), heart failure (HF) (49% vs. 30%), SSE (23% vs. 9%), high CHA 2 DS 2 -VASc (CV) score (3.6 ± 1.8 vs.2.2 ± 1.4), low left ventricular ejection fraction (LVEF) (50 ± 16% vs. 58 ± 21%), and high left atrial volume index (LAVI) (51 ± 26 vs. 40 ± 20 mL/m 2 ). Class I and III antiarrhythmics were less prescribed in the complication group than in the no-complication group (57% vs.76%). Univariate analysis for complications revealed age (≥ 65 years), female sex, DM, HF, SSE, LVEF (< 50%), LAVI (≥ 40 mL/m 2 ), CV score (≥ 3), bradycardia on Holter (< 60/min), and no antiarrhythmics as risk factors. Among these, multivariate analysis revealed clinical significance of female sex and SSE.
Conclusion
Female sex and a history of SSE were the most important risk factors of complications in patients with persistent or long-standing persistent AF/AFL who underwent ECV.
2.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
3.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
4.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
5.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
6.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
7.Real‑world apixaban concentration in Korean patients with atrial fibrillation
Sun Hack LEE ; Mijin KIM ; Min Sun KIM ; Jeongcheon CHOE ; Jinhee AHN ; Hyewon LEE ; Junghyun CHOI ; Han Cheol LEE ; Hyerim KIM ; Kwang Soo CHA
Blood Research 2025;60():39-
Purpose:
Apixaban is recommended for patients with atrial fibrillation. Although routine monitoring of plasma concentrations is not typically advised, factors such as ethnicity, sex, and comorbidities can influence these levels. Our study analyzed the plasma apixaban concentrations (PAC) in patients to explore whether these levels, along with underlying conditions, offer enhanced insights for risk stratification.
Methods:
This study analyzed 49 patients with atrial fibrillation who had been taking apixaban for over a month, examined factor Xa levels within 6 h post-administration, and correlated PAC with clinical characteristics such as age, body weight, estimated glomerular filtration rate (eGFR), presence of heart failure, and bleeding events.
Results:
The mean plasma concentration of apixaban in all patients was 160.3 ± 77.5 ng/mL. Those taking apixaban 5 mg twice daily had higher plasma concentrations than those taking 2.5 mg twice daily (191.2 ± 75.3 ng/mL vs.137.2 ± 72.0 ng/mL, p = 0.014). Among the patients receiving a reduced dose, renal function and heart failure were significantly associated with plasma concentrations. No factors were associated with the plasma concentrations in patients receiving the standard dose. Notably, reduced-dose patients with heart failure had plasma concentrations comparable to those of individuals receiving the standard dose and exhibited a higher incidence of bleeding than the other groups.
Conclusions
PAC measurement revealed that apixaban dosages, classified based on age, body weight, and eGFR, were generally effective. Nonetheless, heart failure may increase plasma levels and correlate with an increased bleeding risk in Korean patients on reduced doses. Therefore, tailoring apixaban prescriptions to account for heart failure and other comorbidities may enhance treatment efficacy.
8.Variations in clinical decision-making on the management of hypertrophic cardiomyopathy: a survey study targeting cardiologists in Korea
Jinsun PARK ; Il-Young OH ; Sang-Jin HAN ; Hwan-Cheol PARK ; Youngjin CHO ; Jin WI ; Kwang-Jin CHUN ; Jinhee AHN ; Do-Young KIM ; Hye Bin GWAG ; Seung-Yong SHIN ; Dong-Jin OH ; Yongkeun CHO ; Myung-Jin CHA
International Journal of Arrhythmia 2025;26(1):e8-
Background and Objectives:
Hypertrophic cardiomyopathy (HCM) increases the risk of sudden cardiac death. Despite international guidelines for sudden death prevention and implantable cardiac defibrillator (ICD) use, clinical practices vary. This study assessed the practices and opinions of Korean cardiologists on HCM management, focusing on ICD use and reimbursement policies.
Methods:
A structured electronic survey was distributed to members of the Korean Society of Cardiology, covering HCM management, ICD preferences, and reimbursement policies.
Results:
A total of 119 cardiologists participated, with most being arrhythmia specialists (56.3%) and university professors (81.5%). Cardiac magnetic resonance imaging and genetic testing were underutilized (30.3% and 11.8%, respectively). Beta-blocker-refractory premature ventricular complexes were primarily managed with continued medical therapy (77.3%). ICD preferences varied by physician specialty and patient age, with subcutaneous ICDs preferred in younger patients and dual-chamber ICDs in older patients. Nearly half of respondents believed ICD reimbursement criteria required revision.
Conclusions
Significant variability in HCM management exists among Korean cardiologists, influenced by restrictive reimbursement criteria rather than clinical guidelines. Updated reimbursement policies and improved access to advanced diagnostics are needed to align with international standards and optimize patient care.
9.Atrial fibrillation fact sheet in Korea 2024 (part 3): treatment for atrial fibrillation in Korea: medicines and ablation
Yun Gi KIM ; Kwang‑No LEE ; Yong‑Soo BAEK ; Bong‑Seong KIM ; Kyung‑Do HAN ; Hyoung‑Seob PARK ; Jinhee AHN ; Jin‑Kyu PARK ; Jaemin SHIM
International Journal of Arrhythmia 2024;25(3):15-
Background:
Atrial fibrillation (AF) is a prevalent cardiac arrhythmia associated with significant morbidity and mortality, posing a considerable burden on healthcare systems. In Republic of Korea, the prevalence and incidence of AF have increased in recent years. There have also been significant changes in the trends of antiarrhythmic drug (AAD) use and procedural treatments for AF.
Objectives:
This study aims to review the trends in AF treatment strategies in Republic of Korea, particularly focusing on the utilization of antiarrhythmic drugs and catheter ablation.
Methods:
The Korean National Health Insurance Service (K-NHIS) data were used to identify AF patients from 2013 to 2022. AAD usage and catheter ablation procedures were analyzed annually. AADs were classified into Class IC and III drugs. Trends in beta-blockers, calcium channel blockers, and digoxin prescriptions were also examined. The primary endpoint was the trend of AAD use and AF catheter ablation (AFCA) over 10 years.
Results:
In 2022, 940,063 patients had a prior diagnosis of AF. From 2013 to 2022, the use of AADs increased from 12.1 to 16.4% among prevalent AF patients. Beta-blockers were the most commonly prescribed rate control medication, while the use of calcium channel blockers and digoxin declined. The frequency of AFCA procedures also increased, from 0.5% of prevalent AF patients in 2013 to 0.7% in 2022. Younger patients, males, and those with lower CHA2DS2-VASc scores were more likely to receive AFCA. Regional variations in treatment patterns were observed, with Seoul exhibiting higher rates of procedural treatments and AAD prescriptions.
Conclusions
Over the past decade, there has been a significant increase in the use of AADs and AFCA procedures in Republic of Korea. These trends reflect recent advancements in AF management advocating a refined rhythm control strategy.
10.Psychotropic Medications Promote Time-Dependent Reduction of Suicidal Ideation in Mood Disorder: A Prospective Cohort Study
Jeong Hun YANG ; C. Hyung Keun PARK ; Sang Jin RHEE ; Dae Hun KANG ; Min Ji KIM ; Hyun Jeong LEE ; Sang Yeol LEE ; Se-Hoon SHIM ; Jung-Joon MOON ; Seong-Jin CHO ; Shin Gyeom KIM ; Min-Hyuk KIM ; Jinhee LEE ; Won Sub KANG ; Jieun YOO ; Weon-Young LEE ; Yong Min AHN
Journal of Korean Medical Science 2024;39(31):e226-
Background:
Despite a plethora of research on the topic, there is still no solid evidence that pharmacological treatment actually reduces the risk of suicide in patients with mental illness.In this study, we aimed to assess the effect of psychotropic medications on suicidal ideation in patients with major depressive disorder (MDD) and bipolar disorder (BPD) in two age groups: less than 25 years and 25 years and older.
Methods:
We analyzed 312 patients with mood disorders with current suicidal thoughts or recent suicide attempts. We followed the participants from baseline for 6 months and assessed changes in suicidal ideation with Columbia-Suicide Severity Rating Scale (C-SSRS).The effect of psychotropic drug administration on suicidal ideation over time was analyzed using a linear mixed model.
Results:
In patients aged 25 years and older with mood disorders, suicidal ideation was more severe when using psychotropic drugs than when not using them. However, suicidal ideation decreased rapidly over time. The time-dependent reduction in suicidal ideation was accelerated when using antidepressants and sedatives/hypnotics in adult MDD, and when using mood stabilizers in adult BPD. However, this effect was not observed in participants aged less than 25 years.
Conclusion
Adequate psychotropic medication may reduce suicidal ideation in patients with mood disorders aged 25 years and older. Additional research on psychotropic drugs is needed to effectively reduce the risk of suicide among children and adolescents with mood disorders.