1.Risk Factors of Complications in Patients With Persistent or Long-Standing Persistent Atrial Fibrillation/Atrial Flutter Who Underwent Electrical Cardioversion:A Multicenter Cardioversion Registry
Ki-Hun KIM ; Junbeom PARK ; Donghwan KU ; Jino PARK ; Seunghwan KIM ; Dong-Kie KIM ; Doo-Il KIM ; Sun Gyu CHOI ; Pil-Sung YANG ; Ju Youn KIM ; Jaemin SHIM ; Jinhee AHN ; Sung Ho LEE ; Sung Il IM ; Hong Euy LIM
Journal of Korean Medical Science 2026;41(1):e19-
Background:
Identifying the risks related to the complications of electrical cardioversion (ECV) can alert the determinaton of rhythm control in patients with atrial fibrillation (AF).
Methods:
We retrospectively reviewed 1,058 patients who underwent ECV for persistent or long-standing persistent AF/atrial flutter (AFL) from multiple centers. Patients were classified into the no-complication (1,023 patients) and complication (35 patients) groups based on the following major complications: stroke and/or systemic embolism (SSE), myocardial infarction, major bleeding, implantation of cardiac implantable electronic devices, ventricular tachycardia/fibrillation, and death at 1 year follow-up after ECV.
Results:
Compared with the no-complication group, the complication group exhibited a higher proportion of female patients (37% vs. 22%), as well as a higher proportion of patients with older age (67 ± 11 vs. 61 ± 10 years), diabetes mellitus (DM) (49% vs. 24%), heart failure (HF) (49% vs. 30%), SSE (23% vs. 9%), high CHA 2 DS 2 -VASc (CV) score (3.6 ± 1.8 vs.2.2 ± 1.4), low left ventricular ejection fraction (LVEF) (50 ± 16% vs. 58 ± 21%), and high left atrial volume index (LAVI) (51 ± 26 vs. 40 ± 20 mL/m 2 ). Class I and III antiarrhythmics were less prescribed in the complication group than in the no-complication group (57% vs.76%). Univariate analysis for complications revealed age (≥ 65 years), female sex, DM, HF, SSE, LVEF (< 50%), LAVI (≥ 40 mL/m 2 ), CV score (≥ 3), bradycardia on Holter (< 60/min), and no antiarrhythmics as risk factors. Among these, multivariate analysis revealed clinical significance of female sex and SSE.
Conclusion
Female sex and a history of SSE were the most important risk factors of complications in patients with persistent or long-standing persistent AF/AFL who underwent ECV.
2.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
3.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
4.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
5.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
6.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
7.Real‑world apixaban concentration in Korean patients with atrial fibrillation
Sun Hack LEE ; Mijin KIM ; Min Sun KIM ; Jeongcheon CHOE ; Jinhee AHN ; Hyewon LEE ; Junghyun CHOI ; Han Cheol LEE ; Hyerim KIM ; Kwang Soo CHA
Blood Research 2025;60():39-
Purpose:
Apixaban is recommended for patients with atrial fibrillation. Although routine monitoring of plasma concentrations is not typically advised, factors such as ethnicity, sex, and comorbidities can influence these levels. Our study analyzed the plasma apixaban concentrations (PAC) in patients to explore whether these levels, along with underlying conditions, offer enhanced insights for risk stratification.
Methods:
This study analyzed 49 patients with atrial fibrillation who had been taking apixaban for over a month, examined factor Xa levels within 6 h post-administration, and correlated PAC with clinical characteristics such as age, body weight, estimated glomerular filtration rate (eGFR), presence of heart failure, and bleeding events.
Results:
The mean plasma concentration of apixaban in all patients was 160.3 ± 77.5 ng/mL. Those taking apixaban 5 mg twice daily had higher plasma concentrations than those taking 2.5 mg twice daily (191.2 ± 75.3 ng/mL vs.137.2 ± 72.0 ng/mL, p = 0.014). Among the patients receiving a reduced dose, renal function and heart failure were significantly associated with plasma concentrations. No factors were associated with the plasma concentrations in patients receiving the standard dose. Notably, reduced-dose patients with heart failure had plasma concentrations comparable to those of individuals receiving the standard dose and exhibited a higher incidence of bleeding than the other groups.
Conclusions
PAC measurement revealed that apixaban dosages, classified based on age, body weight, and eGFR, were generally effective. Nonetheless, heart failure may increase plasma levels and correlate with an increased bleeding risk in Korean patients on reduced doses. Therefore, tailoring apixaban prescriptions to account for heart failure and other comorbidities may enhance treatment efficacy.
8.Variations in clinical decision-making on the management of hypertrophic cardiomyopathy: a survey study targeting cardiologists in Korea
Jinsun PARK ; Il-Young OH ; Sang-Jin HAN ; Hwan-Cheol PARK ; Youngjin CHO ; Jin WI ; Kwang-Jin CHUN ; Jinhee AHN ; Do-Young KIM ; Hye Bin GWAG ; Seung-Yong SHIN ; Dong-Jin OH ; Yongkeun CHO ; Myung-Jin CHA
International Journal of Arrhythmia 2025;26(1):e8-
Background and Objectives:
Hypertrophic cardiomyopathy (HCM) increases the risk of sudden cardiac death. Despite international guidelines for sudden death prevention and implantable cardiac defibrillator (ICD) use, clinical practices vary. This study assessed the practices and opinions of Korean cardiologists on HCM management, focusing on ICD use and reimbursement policies.
Methods:
A structured electronic survey was distributed to members of the Korean Society of Cardiology, covering HCM management, ICD preferences, and reimbursement policies.
Results:
A total of 119 cardiologists participated, with most being arrhythmia specialists (56.3%) and university professors (81.5%). Cardiac magnetic resonance imaging and genetic testing were underutilized (30.3% and 11.8%, respectively). Beta-blocker-refractory premature ventricular complexes were primarily managed with continued medical therapy (77.3%). ICD preferences varied by physician specialty and patient age, with subcutaneous ICDs preferred in younger patients and dual-chamber ICDs in older patients. Nearly half of respondents believed ICD reimbursement criteria required revision.
Conclusions
Significant variability in HCM management exists among Korean cardiologists, influenced by restrictive reimbursement criteria rather than clinical guidelines. Updated reimbursement policies and improved access to advanced diagnostics are needed to align with international standards and optimize patient care.
9.Comparison of Short- and Long-Term Dual-Antiplatelet Therapy After Transcatheter Aortic Valve Replacement: One-Year Outcomes
Jun-Hyok OH ; Jinmi KIM ; Jeong-Su KIM ; Hye Won LEE ; Sun Hack LEE ; Jeong Cheon CHOE ; Min Sun KIM ; Jinhee AHN ; Jung Hyun CHOI ; Han Cheol LEE ; Kwang Soo CHA
Journal of Korean Medical Science 2024;39(47):e294-
Background:
The optimal duration and net clinical benefit of dual antiplatelet therapy (DAPT) after transcatheter aortic valve replacement (TAVR) have not been elucidated in realworld situations.
Methods:
Using nationwide claims data from 2013 to 2021, we selected patients who underwent TAVR and categorized them into two groups: short- and long-term (≤ 3 and > 3 months, respectively) DAPT group. Propensity score matching was used to balance baseline characteristics. The primary endpoint was the occurrence of net adverse clinical events (NACEs), including all-cause death, myocardial infarction, stroke, any coronary and peripheral revascularization, systemic thromboembolism, and bleeding events, at 1 year. Survival analyses were conducted using Kaplan-Meier estimation and Cox proportional hazards regression.
Results:
Patients who met the inclusion criteria (1,695) were selected. Propensity score matching yielded 1,215 pairs of patients: 416 and 799 in the short- and long-term DAPT groups, respectively. In the unmatched cohort, the mean ages were 79.8 ± 6.1 and 79.7 ± 5.8 years for the short- and long-term DAPT groups, respectively. In the matched cohort, the mean ages were 80.6 ± 5.9 and 79.9 ± 5.9 years for the short- and long-term DAPT groups, respectively. Over one year in the unmatched cohort, the NACE incidence was 11.9% and 11.5% in the short- and long-term DAPT groups, respectively (P = 0.893). The all-cause mortality rates were 7.4% and 4.7% (P = 0.042), composite ischemic event rates were 2.5% and 4.7% (P = 0.056), and bleeding event rates were 2.7% and 4.7% (P = 0.056) in the shortand long-term groups, respectively. In the matched cohort, the incidence of NACE was 9.6% in the short-term DAPT group and 11.6% in the long-term DAPT group, respectively (P = 0.329).The all-cause mortality rates were 6.5% and 4.9% (P = 0.298), composite ischemic event rates were 1.4% and 4.5% (P = 0.009), and bleeding event rates were 2.2% and 4.4% (P = 0.072) in the short- and long-term groups, respectively.
Conclusion
In patients who successfully underwent transfemoral TAVR, the short- and longterm DAPT groups exhibited similar one-year NACE rates. However, patients in the long-term DAPT group experienced more bleeding and ischemic events.
10.Characteristics of High-Risk Groups for Suicide in Korea Before and After the COVID-19 Pandemic: K-COMPASS Cohort Study
Jeong Hun YANG ; Dae Hun KANG ; C. Hyung Keun PARK ; Min Ji KIM ; Sang Jin RHEE ; Min-Hyuk KIM ; Jinhee LEE ; Sang Yeol LEE ; Won Sub KANG ; Seong-Jin CHO ; Shin Gyeom KIM ; Se-Hoon SHIM ; Jung-Joon MOON ; Jieun YOO ; Weon-Young LEE ; Yong Min AHN
Journal of Korean Neuropsychiatric Association 2024;63(4):246-259
Objectives:
This study examined the changes in the characteristics of high-risk suicide groups in South Korea before and after the COVID-19 pandemic using the Korean Cohort for the Model Predicting a Suicide and Suicide-related Behavior (K-COMPASS) cohort.
Methods:
The K-COMPASS is a longitudinal cohort study that started in 2015. The participants included suicide attempters and individuals with suicidal ideation from various hospitals and mental health centers in South Korea. This study compared the sociodemographic and psychiatric characteristics of 800 participants from the first cohort (2015–2019) with 511 participants from the second and third cohorts (2019–2024). Data were collected through structured interviews and validated scales.
Results:
The second and third cohort participants were younger, had a higher proportion of females, and exhibited more severe psychiatric symptoms and higher suicidal risk than the first cohort. The prevalence of physical illnesses decreased, while the use of psychiatric medications and the severity of mental health issues increased. In addition, significant sociodemographic changes were observed, such as higher educational levels and urban residency.
Conclusion
Significant shifts in the characteristics of high-risk suicide groups were observed during the COVID-19 pandemic, highlighting the need for targeted mental health interventions focusing on younger individuals and females to prevent suicide in high-risk groups.

Result Analysis
Print
Save
E-mail